Mehmet Emin Meral
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mehmet Emin Meral has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Teke
Çukurova University
7 shared publications - Doğan Çelik
Van Yüzüncü Yil University
7 shared publications Doğan Çelik
Van Yüzüncü Yıl University
3 shared publicationsMehmet Tumay
Cukurova Univ, Dept Elect & Elect Engn, Adana, Turkey
3 shared publicationsMehmet Tümay
Electrical and Electronics Engineering Department Çukurova University Adana Turkey
3 shared publicationsK. Cagatay Bayindir
Cukurova Univ, Dept Elect & Elect Engn, Adana, Turkey
2 shared publications
Latest Publications
- 12 July 2026
- Published by Springer Nature
- p. 195-221
Extended Kalman Filter
- Open Access
- 7 January 2025
- Published by Balkan Journal of Electrical & Computer Engineering (BAJECE) in Balkan Journal of Electrical and Computer Engineering
- Vol. 12 (4) , 282-293
Comparative Analysis of PI and PR Control Strategies for Enhancing Voltage Quality in D-Statcom-Based Distribution Networks
In recent years, the rise in the number of sensitive loads in distribution networks has highlighted the importance of not only ensuring the continuity of electricity supplies but also maintaining high power quality for consumers. In the present era, one of the most prevalent power quality issues in power systems is voltage sag, which is responsible for over 80% of the observed problems. Although the duration of the disturbance is relatively brief, typically between 10 ms and 1 minute, it can have a significant impact on the production process due to a minor deviation from the rated voltage. The disturbance can occur within a second, but the restoration process can take several hours. In order to enhance the power quality of the grid, it is essential to regulate reactive power. The objective of this study is to utilise a D-STATCOM for the correction of voltage by connecting it in parallel to the bus connection point between the grid and the loads. Modelling and simulation studies have been conducted to investigate the contribution of D-STATCOM with PI (proportional-integral) or PR (proportional resonance) controllers to the system in response to various fault scenarios that cause voltage sags by commissioning various loads at low voltage (0.4 kV). The simulation of both models was conducted using the PSCAD/EMTDC program. The performance of both controllers is evaluated through a comparison with the PSCAD/EMTDC simulation program. The results demonstrate that the D-STATCOM responds to short-term voltage sags caused by a fault or other system disturbances with a high degree of efficiency, rapidly restoring the bus voltage to a level close to the nominal value. This effectively mitigates the potential disruptions associated with voltage collapse. Furthermore, the analysis reveals that D-STATCOMs employing PI and PR controllers exhibit a combination of advantages and limitations in their performance.
- 7 January 2025
- Published by Balkan Journal of Electrical & Computer Engineering (BAJECE) in Balkan Journal of Electrical and Computer Engineering
- Vol. 12 (4) , 282-293
Open AccessComparative Analysis of PI and PR Control Strategies for Enhancing Voltage Quality in D-Statcom-Based Distribution Networks
In recent years, the rise in the number of sensitive loads in distribution networks has highlighted the importance of not only ensuring the continuity of electricity supplies but also maintaining high power quality for consumers. In the present era, one of the most prevalent power quality issues in power systems is voltage sag, which is responsible for over 80% of the observed problems. Although the duration of the disturbance is relatively brief, typically between 10 ms and 1 minute, it can have a significant impact on the production process due to a minor deviation from the rated voltage. The disturbance can occur within a second, but the restoration process can take several hours. In order to enhance the power quality of the grid, it is essential to regulate reactive power. The objective of this study is to utilise a D-STATCOM for the correction of voltage by connecting it in parallel to the bus connection point between the grid and the loads. Modelling and simulation studies have been conducted to investigate the contribution of D-STATCOM with PI (proportional-integral) or PR (proportional resonance) controllers to the system in response to various fault scenarios that cause voltage sags by commissioning various loads at low voltage (0.4 kV). The simulation of both models was conducted using the PSCAD/EMTDC program. The performance of both controllers is evaluated through a comparison with the PSCAD/EMTDC simulation program. The results demonstrate that the D-STATCOM responds to short-term voltage sags caused by a fault or other system disturbances with a high degree of efficiency, rapidly restoring the bus voltage to a level close to the nominal value. This effectively mitigates the potential disruptions associated with voltage collapse. Furthermore, the analysis reveals that D-STATCOMs employing PI and PR controllers exhibit a combination of advantages and limitations in their performance.
- 13 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (2) , 1097-1107
Kalman Filter-Based Super-Twisting Sliding Mode Control of Shunt Active Power Filter for Electric Vehicle Charging Station Applications
Electric vehicle (EV) charging stations draw nonlinear currents, which makes the distribution network unbalanced, distorted, and results in power quality (PQ) issues. These PQ issues are mitigated in this work through high-performance control of the shunt active power filter (SAPF). In the proposed method, a linear Kalman filter (LKF) has been applied to grid voltage and load current signals for harmonic and disturbance robust estimation purpose. Unlike the conventionally used orthogonal vector model, in this work, phase angle vector model together with a simple to tune phase-locked loop (PLL) has been considered for the LKF implementation. DC-link voltage regulation and charging of the DC-link capacitor has been obtained by proposing a Luenberger observer-based super twisting sliding mode control (ST-SMC), which has fast dynamic response and lower voltage ripples compared to similar other existing control methods. This results in significant reduction in size, cost and loss together with lifetime enhancement of the DC-link capacitor. Rigorous sensitivity analysis is conducted to analyze the robustness of the developed method. The proposed control technique achieves fast response time and satisfy the harmonic requirements as specified in the IEEE Std. 519 under various grid and load disturbances. Comparative quasi-real time validation results are presented by using digital signal processor (DSP) based processor-in-the-loop (PIL) with another recently proposed control strategy to verify the performance enhancement by the developed method.
- 13 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (2) , 1097-1107
Kalman Filter-Based Super-Twisting Sliding Mode Control of Shunt Active Power Filter for Electric Vehicle Charging Station Applications
Electric vehicle (EV) charging stations draw nonlinear currents, which makes the distribution network unbalanced, distorted, and results in power quality (PQ) issues. These PQ issues are mitigated in this work through high-performance control of the shunt active power filter (SAPF). In the proposed method, a linear Kalman filter (LKF) has been applied to grid voltage and load current signals for harmonic and disturbance robust estimation purpose. Unlike the conventionally used orthogonal vector model, in this work, phase angle vector model together with a simple to tune phase-locked loop (PLL) has been considered for the LKF implementation. DC-link voltage regulation and charging of the DC-link capacitor has been obtained by proposing a Luenberger observer-based super twisting sliding mode control (ST-SMC), which has fast dynamic response and lower voltage ripples compared to similar other existing control methods. This results in significant reduction in size, cost and loss together with lifetime enhancement of the DC-link capacitor. Rigorous sensitivity analysis is conducted to analyze the robustness of the developed method. The proposed control technique achieves fast response time and satisfy the harmonic requirements as specified in the IEEE Std. 519 under various grid and load disturbances. Comparative quasi-real time validation results are presented by using digital signal processor (DSP) based processor-in-the-loop (PIL) with another recently proposed control strategy to verify the performance enhancement by the developed method.
- 1 October 2020
- Published by Elsevier in Control Engineering Practice
- Vol. 103
Proportional complex integral based control of distributed energy converters connected to unbalanced grid system
- 1 October 2020
- Published by Elsevier in Control Engineering Practice
- Vol. 103
Proportional complex integral based control of distributed energy converters connected to unbalanced grid system
- Open Access
- 25 October 2019
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 35 (1) , 537-550
Şebekeye bağlı yenilenebilir enerji kaynaklı eviriciler için yeni bir akım kontrol stratejisi
Dengesiz şebeke gerilimleri pozitif ve negatif sıralı (PNS) bileşenleri içermektedir. Özelikle, kontrol sinyallerinin üzerindeki salınımlara sebep olan negatif sıralı bileşenler şebekeye bağlı yenilenebilir enerji kaynaklı eviricilerin (YEKI) performansını önemli derecede etkilemektedir. Bu çalışmada, ideal olmayan şebeke gerilim şartlarında şebekeye bağlı YEKI’ in kontrolü için kullanılan oransal integral (PI) tabanlı ikili akım kontrolcünün yavaş dinamik tepkisi, kararlı hal hataları ve kompleks yapısı gibi dezavantajlarının giderilmesi için oransal kompleks integratör (PCI) tabanlı akım kontrolcüsü önerilmiştir. Aktif-reaktif güç referans sinyali, PNS bileşenleri ve esnek kontrol parametresine dayanan referans akımlar, tüm kontrol döngülerinde kullanılmak üzere üretilmiştir. İdeal olmayan şebeke durumlarından kaynaklanan aktif ve reaktif güç salınımlarının bir biri ile olan ilişkileri ayrıntılı bir şekilde incelenip kontrol edilebilirlikleri esnek kontrol parametresi ile sağlanmıştır. Çalışmanın literatürdeki benzer i çalışmalara kıyasla önemli bir katkısı, referans akım üretimi için gerekli PNS gerilim ve akım bileşenlerinin önerilen hızlı ve sağlam ikili ortalama filtre tabanlı faz kilitlemeli döngü (DAPLL) ile ayrılmasıdır. Önerilen PCI tabanlı akım kontrol stratejisinin performansı çeşitli durum çalışmaları kullanılarak PI tabanlı ikili akım kontrolcü ile karşılaştırılıp test edilmiştir.
- 25 October 2019
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 35 (1) , 537-550
Open AccessŞebekeye bağlı yenilenebilir enerji kaynaklı eviriciler için yeni bir akım kontrol stratejisi
Dengesiz şebeke gerilimleri pozitif ve negatif sıralı (PNS) bileşenleri içermektedir. Özelikle, kontrol sinyallerinin üzerindeki salınımlara sebep olan negatif sıralı bileşenler şebekeye bağlı yenilenebilir enerji kaynaklı eviricilerin (YEKI) performansını önemli derecede etkilemektedir. Bu çalışmada, ideal olmayan şebeke gerilim şartlarında şebekeye bağlı YEKI’ in kontrolü için kullanılan oransal integral (PI) tabanlı ikili akım kontrolcünün yavaş dinamik tepkisi, kararlı hal hataları ve kompleks yapısı gibi dezavantajlarının giderilmesi için oransal kompleks integratör (PCI) tabanlı akım kontrolcüsü önerilmiştir. Aktif-reaktif güç referans sinyali, PNS bileşenleri ve esnek kontrol parametresine dayanan referans akımlar, tüm kontrol döngülerinde kullanılmak üzere üretilmiştir. İdeal olmayan şebeke durumlarından kaynaklanan aktif ve reaktif güç salınımlarının bir biri ile olan ilişkileri ayrıntılı bir şekilde incelenip kontrol edilebilirlikleri esnek kontrol parametresi ile sağlanmıştır. Çalışmanın literatürdeki benzer i çalışmalara kıyasla önemli bir katkısı, referans akım üretimi için gerekli PNS gerilim ve akım bileşenlerinin önerilen hızlı ve sağlam ikili ortalama filtre tabanlı faz kilitlemeli döngü (DAPLL) ile ayrılmasıdır. Önerilen PCI tabanlı akım kontrol stratejisinin performansı çeşitli durum çalışmaları kullanılarak PI tabanlı ikili akım kontrolcü ile karşılaştırılıp test edilmiştir.
- 1 January 2019
- Published by Elsevier in Annual Reviews in Control
- Vol. 47, 112-132
A comprehensive survey on control strategies of distributed generation power systems under normal and abnormal conditions
- 1 January 2019
- Published by Elsevier in Annual Reviews in Control
- Vol. 47, 112-132
A comprehensive survey on control strategies of distributed generation power systems under normal and abnormal conditions
- 1 January 2019
- Published by Elsevier in Control Engineering Practice
- Vol. 82, 72-85
Current control based power management strategy for distributed power generation system
- 1 January 2019
- Published by Elsevier in Control Engineering Practice
- Vol. 82, 72-85
Current control based power management strategy for distributed power generation system
- 1 January 2019
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 104, 456-471
A flexible control strategy with overcurrent limitation in distributed generation systems
- 1 January 2019
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 104, 456-471
A flexible control strategy with overcurrent limitation in distributed generation systems
- 11 November 2017
- Published by Springer Nature in Electrical Engineering
- Vol. 100 (3) , 1805-1817
Benchmarking simulation and theory of various PLLs produce orthogonal signals under abnormal electric grid conditions
- 11 November 2017
- Published by Springer Nature in Electrical Engineering
- Vol. 100 (3) , 1805-1817
Benchmarking simulation and theory of various PLLs produce orthogonal signals under abnormal electric grid conditions