Chellachi Kathiresan Aravind
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chellachi Kathiresan Aravind has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Chilakapati Nagamani
Department of Electrical and Electronics Engineering National Institute of Technology Tiruchirappalli India
3 shared publications- Pandia Rajan Jeyaraj
Department of Electrical and Electronics Engineering, Mepco Schlenk Engineering College, Sivakasi, India
3 shared publications - Saravana Ilango Ganesan
National Institute of Technology
3 shared publications - Thanikanti Sudhakar Babu
Chaitanya Bharathi Institute of Technology
3 shared publications - Asokan Sivaprakash
Mepco Schlenk Engn Coll Autonomous, Sivakasi, Tamil Nadu, India
2 shared publications C. Nagamani
National Institute of Technology
2 shared publications
Latest Publications
- 23 October 2026
- Published by Taylor & Francis
- p. 123-135
Performance Grading Strategies of Passive Candidates for Distinguishing Island and Non-Island Disturbances in a DG Integrated Power Distribution Network: A Review
Unintentional loss of the grid has the potential to endanger human life and equipment safety. As per IEEE 1547-2018 std. this unplanned island formation must be identified and the distributed generation (DG) sources available in the islanded region of the power system network must be tripped. Among various strategies to detect unplanned islands, the passive strategies are the simplest and cheapest. Apart from the basic voltage and frequency, other candidates are also explored for their suitability to detect unintentional island formation. In this chapter, a brief review of the performance analysis of various passive candidates (derived from the basic candidates, viz. voltage, frequency, phase angle, active power, reactive power and total harmonic distortion (THD)) is presented. This review provides an overview of the performance grading strategies for prioritization of passive candidates. This prioritization gives the potential passive candidates the ability to distinguish accurately between disturbances due to loss of grid (island disturbances) and those not due to loss of grid (non-island disturbances).
- 23 October 2026
- Published by Taylor & Francis
- p. 123-135
Performance Grading Strategies of Passive Candidates for Distinguishing Island and Non-Island Disturbances in a DG Integrated Power Distribution Network: A Review
Unintentional loss of the grid has the potential to endanger human life and equipment safety. As per IEEE 1547-2018 std. this unplanned island formation must be identified and the distributed generation (DG) sources available in the islanded region of the power system network must be tripped. Among various strategies to detect unplanned islands, the passive strategies are the simplest and cheapest. Apart from the basic voltage and frequency, other candidates are also explored for their suitability to detect unintentional island formation. In this chapter, a brief review of the performance analysis of various passive candidates (derived from the basic candidates, viz. voltage, frequency, phase angle, active power, reactive power and total harmonic distortion (THD)) is presented. This review provides an overview of the performance grading strategies for prioritization of passive candidates. This prioritization gives the potential passive candidates the ability to distinguish accurately between disturbances due to loss of grid (island disturbances) and those not due to loss of grid (non-island disturbances).
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (3) , 2103-2114
Development and Performance Analysis of Aquila Algorithm Optimized SPV Power Imputation and Forecasting Models
Solar photovoltaic (SPV) generators play a vital role in the global pursuit of sustainable energy. However, the intermittent nature of SPV generators poses a challenge to power system planning. Accurate long-term SPV power forecasting is essential, but obtaining high-quality training data for many years is cumbersome due to faults in sensors, communication, or databases, leading to missing values. This paper proposes an attention network (AN) for SPV power imputation to address missing historical data. In addition, the SPV power forecasting model using BDLSTM NN is proposed for forecasting the SPV power in the long-term horizon. During training, the weights and biases of the imputation and forecasting models are proposed to be optimized using the Aquila optimization algorithm (AOA). Training and testing results substantiate that the proposed imputation and forecasting models consistently attain superior accuracy with a reduction in training time regardless of the missing rates, climatic patterns, and seasons as compared to benchmark models.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (3) , 2103-2114
Development and Performance Analysis of Aquila Algorithm Optimized SPV Power Imputation and Forecasting Models
Solar photovoltaic (SPV) generators play a vital role in the global pursuit of sustainable energy. However, the intermittent nature of SPV generators poses a challenge to power system planning. Accurate long-term SPV power forecasting is essential, but obtaining high-quality training data for many years is cumbersome due to faults in sensors, communication, or databases, leading to missing values. This paper proposes an attention network (AN) for SPV power imputation to address missing historical data. In addition, the SPV power forecasting model using BDLSTM NN is proposed for forecasting the SPV power in the long-term horizon. During training, the weights and biases of the imputation and forecasting models are proposed to be optimized using the Aquila optimization algorithm (AOA). Training and testing results substantiate that the proposed imputation and forecasting models consistently attain superior accuracy with a reduction in training time regardless of the missing rates, climatic patterns, and seasons as compared to benchmark models.
- Open Access
- 24 September 2022
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
A versatile control of solar DVR for enhanced utilization and power quality improvement in a series‐connected wind‐solar farm
This paper presents a solar dynamic voltage restorer for hybrid series‐connected solar‐wind farms to mitigate the power quality problems. The operating region of the proposed hybrid system is derived and studied through graphical analysis. Upon examination of the system's operation under various grid conditions, the feasibility of solar PV power injected into the grid is verified. It is further proved that the series injection of voltage is also capable of mitigating the effects of voltage sag/swell, and unbalance, which have adverse effects on wind‐connected induction generators. Further, the effectiveness of Solar DVR to mitigate the fault ride‐through capability of the wind farm is analyzed. The non‐requirement for an energy storage device such as a battery is also validated. A control system for the series PV inverter is proposed and the computer simulations are performed to confirm the efficacy and ride‐through capability of the system.
- 24 September 2022
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessA versatile control of solar DVR for enhanced utilization and power quality improvement in a series‐connected wind‐solar farm
This paper presents a solar dynamic voltage restorer for hybrid series‐connected solar‐wind farms to mitigate the power quality problems. The operating region of the proposed hybrid system is derived and studied through graphical analysis. Upon examination of the system's operation under various grid conditions, the feasibility of solar PV power injected into the grid is verified. It is further proved that the series injection of voltage is also capable of mitigating the effects of voltage sag/swell, and unbalance, which have adverse effects on wind‐connected induction generators. Further, the effectiveness of Solar DVR to mitigate the fault ride‐through capability of the wind farm is analyzed. The non‐requirement for an energy storage device such as a battery is also validated. A control system for the series PV inverter is proposed and the computer simulations are performed to confirm the efficacy and ride‐through capability of the system.
- Open Access
- 1 January 2021
- Published by Tech Science Press in Computers, Materials & Continua
- Vol. 68 (1) , 553-567
Power System Resiliency and Wide Area Control Employing Deep Learning Algorithm
The power transfer capability of the smart transmission grid-connected networks needs to be reduced by inter-area oscillations. Due to the fact that inter-area modes of oscillations detain and make instability of power transmission networks. This fact is more noticeable in smart grid-connected systems. The smart grid infrastructure has more renewable energy resources installed for its operation. To overcome this problem, a deep learning wide-area controller is proposed for real-time parameter control and smart power grid resilience on oscillations inter-area modes. The proposed Deep Wide Area Controller (DWAC) uses the Deep Belief Network (DBN). The network weights are updated based on real-time data from Phasor measurement units. Resilience assessment based on failure probability, financial impact, and time-series data in grid failure management determine the norm . To demonstrate the effectiveness of the proposed framework, a time-domain simulation case study based on the IEEE-39 bus system was performed. For a one-channel attack on the test system, the resiliency index increased to 0.962, and inter-area damping was reduced to 0.005. The obtained results validate the proposed deep learning algorithm’s efficiency on damping inter-area and local oscillation on the 2-channel attack as well. Results also offer robust management of power system resilience and timely control of the operating conditions.
- 1 January 2021
- Published by Tech Science Press in Computers, Materials & Continua
- Vol. 68 (1) , 553-567
Open AccessPower System Resiliency and Wide Area Control Employing Deep Learning Algorithm
The power transfer capability of the smart transmission grid-connected networks needs to be reduced by inter-area oscillations. Due to the fact that inter-area modes of oscillations detain and make instability of power transmission networks. This fact is more noticeable in smart grid-connected systems. The smart grid infrastructure has more renewable energy resources installed for its operation. To overcome this problem, a deep learning wide-area controller is proposed for real-time parameter control and smart power grid resilience on oscillations inter-area modes. The proposed Deep Wide Area Controller (DWAC) uses the Deep Belief Network (DBN). The network weights are updated based on real-time data from Phasor measurement units. Resilience assessment based on failure probability, financial impact, and time-series data in grid failure management determine the norm . To demonstrate the effectiveness of the proposed framework, a time-domain simulation case study based on the IEEE-39 bus system was performed. For a one-channel attack on the test system, the resiliency index increased to 0.962, and inter-area damping was reduced to 0.005. The obtained results validate the proposed deep learning algorithm’s efficiency on damping inter-area and local oscillation on the 2-channel attack as well. Results also offer robust management of power system resilience and timely control of the operating conditions.
- Open Access
- 29 August 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (17) , 7048
An Adaptive Feed-Forward Phase Locked Loop for Grid Synchronization of Renewable Energy Systems under Wide Frequency Deviations
Synchronization is a crucial problem in the grid-connected inverter’s control and operation. A phase-locked loop (PLL) is a typical grid synchronization strategy, which ought to have a high resistance to power system uncertainties since its sensitivity influences the generated reference signal. The traditional PLL catches the phase and frequency of the input signal via the feedback loop filter (LF). In general, to enhance the steady-state capability during distorted grid conditions generally, a filter tuned for nominal frequency is used. This PLL corrects large frequency deviations around the nominal frequency, which increases the PLL’s locking time. Therefore, this paper presents an adaptive feed-forward PLL, where the input signal frequency and phase under large frequency deviations are tracked precisely, which overcomes the above-mentioned limitations. The proposed adaptive PLL consists of a feedback loop that reduces the phase error. The feed-forward loop predicts the frequency and phase error, and the frequency adaptive FIR filter reduces the ripples in output, which is due to input distortions. The adaptive mechanism adjusts the gain of the filter in accordance with the supply frequency. This reduces the phase and frequency error and also decreases the locking time under wide frequency deviations. To verify the effectiveness of the proposed adaptive feed-forward PLL, the system was tested under different grid abnormal conditions. Further, the stability analysis has been carried out via a developed prototype test platform in the laboratory. To bring the proposed simulations into real-time implementations and for control strategies, an Altera Cyclone II field-programmable gate array (FPGA) board has been used. The obtained results of the proposed PLL via simulations and hardware are compared with conventional techniques, and it indicates the superiority of the proposed method. The proposed PLL effectively able to tackle the different grid uncertainties, which can be observed from the results presented in the result section.
- 29 August 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (17) , 7048
Open AccessAn Adaptive Feed-Forward Phase Locked Loop for Grid Synchronization of Renewable Energy Systems under Wide Frequency Deviations
Synchronization is a crucial problem in the grid-connected inverter’s control and operation. A phase-locked loop (PLL) is a typical grid synchronization strategy, which ought to have a high resistance to power system uncertainties since its sensitivity influences the generated reference signal. The traditional PLL catches the phase and frequency of the input signal via the feedback loop filter (LF). In general, to enhance the steady-state capability during distorted grid conditions generally, a filter tuned for nominal frequency is used. This PLL corrects large frequency deviations around the nominal frequency, which increases the PLL’s locking time. Therefore, this paper presents an adaptive feed-forward PLL, where the input signal frequency and phase under large frequency deviations are tracked precisely, which overcomes the above-mentioned limitations. The proposed adaptive PLL consists of a feedback loop that reduces the phase error. The feed-forward loop predicts the frequency and phase error, and the frequency adaptive FIR filter reduces the ripples in output, which is due to input distortions. The adaptive mechanism adjusts the gain of the filter in accordance with the supply frequency. This reduces the phase and frequency error and also decreases the locking time under wide frequency deviations. To verify the effectiveness of the proposed adaptive feed-forward PLL, the system was tested under different grid abnormal conditions. Further, the stability analysis has been carried out via a developed prototype test platform in the laboratory. To bring the proposed simulations into real-time implementations and for control strategies, an Altera Cyclone II field-programmable gate array (FPGA) board has been used. The obtained results of the proposed PLL via simulations and hardware are compared with conventional techniques, and it indicates the superiority of the proposed method. The proposed PLL effectively able to tackle the different grid uncertainties, which can be observed from the results presented in the result section.
- Open Access
- 25 October 2018
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 11 (14) , 2385-2395
PV‐fed DVR for simultaneous real power injection and sag/swell mitigation in a wind farm
Generally, a dynamic voltage restorer (DVR) installed in a grid‐connected wind farm, is utilised for mitigating sag/swell in grid voltage and hence stays idle under nominal grid voltage. To enhance the utility of such a DVR, this study proposes to install a solar photovoltaic (PV) plant in the DVR, so that in addition to addressing sag/swell in grid voltage, energy can be harvested and injected into the grid from the PV plant using the same DVR. Various modes of operations of the proposed PV‐assisted DVR (PVDVR) are described, underlining the logically set priorities. Comprehensive mathematical and graphical analyses are developed to explore the boundaries of the operating region of each mode of PVDVR considering fluctuations in grid voltage and available PV power. Investigations are carried out in a 50 MW wind farm and a 0.75 kW laboratory induction machine (both grid connected) each with a suitable DVR. Results of simulations in power systems computer‐aided design/electro‐magnetic transient design and control and laboratory tests demonstrate improved utilisation of DVR when fed from PV plant.
- 25 October 2018
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 11 (14) , 2385-2395
Open AccessPV‐fed DVR for simultaneous real power injection and sag/swell mitigation in a wind farm
Generally, a dynamic voltage restorer (DVR) installed in a grid‐connected wind farm, is utilised for mitigating sag/swell in grid voltage and hence stays idle under nominal grid voltage. To enhance the utility of such a DVR, this study proposes to install a solar photovoltaic (PV) plant in the DVR, so that in addition to addressing sag/swell in grid voltage, energy can be harvested and injected into the grid from the PV plant using the same DVR. Various modes of operations of the proposed PV‐assisted DVR (PVDVR) are described, underlining the logically set priorities. Comprehensive mathematical and graphical analyses are developed to explore the boundaries of the operating region of each mode of PVDVR considering fluctuations in grid voltage and available PV power. Investigations are carried out in a 50 MW wind farm and a 0.75 kW laboratory induction machine (both grid connected) each with a suitable DVR. Results of simulations in power systems computer‐aided design/electro‐magnetic transient design and control and laboratory tests demonstrate improved utilisation of DVR when fed from PV plant.
- 8 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 5 (3) , 971-981
Performance Evaluation of Type-3 PLLs Under Wide Variation in Input Voltage and Frequency
This paper presents a detailed analysis of Type-3 phase locked loop (PLL) under wide variation in input voltage and frequency. Using small signal modeling, the performance of both single loop and dual loop Type-3 PLL for variation in input voltage and frequency is studied. The analysis shows that for the same bandwidth, both the single loop and dual loop Type-3 PLLs exhibit similar dynamics provided the supply voltage is balanced. However, under voltage sag conditions, dual loop PLL shows improved dynamic response without affecting its stability. Further, the tracking time is reduced as the feed forward frequency is a function of supply frequency. To improve the filtering characteristics under frequency deviations, a dual loop Type 3 adaptive PLL which accurately tracks the phase and frequency of the input signal under wide frequency deviations is developed. Simulations are carried out in MATLAB and experimentally verified by implementing in ALTERA cyclone II Field Programmable Gate Array (FPGA) board.
- 8 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 5 (3) , 971-981
Performance Evaluation of Type-3 PLLs Under Wide Variation in Input Voltage and Frequency
This paper presents a detailed analysis of Type-3 phase locked loop (PLL) under wide variation in input voltage and frequency. Using small signal modeling, the performance of both single loop and dual loop Type-3 PLL for variation in input voltage and frequency is studied. The analysis shows that for the same bandwidth, both the single loop and dual loop Type-3 PLLs exhibit similar dynamics provided the supply voltage is balanced. However, under voltage sag conditions, dual loop PLL shows improved dynamic response without affecting its stability. Further, the tracking time is reduced as the feed forward frequency is a function of supply frequency. To improve the filtering characteristics under frequency deviations, a dual loop Type 3 adaptive PLL which accurately tracks the phase and frequency of the input signal under wide frequency deviations is developed. Simulations are carried out in MATLAB and experimentally verified by implementing in ALTERA cyclone II Field Programmable Gate Array (FPGA) board.
- 11 May 2015
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 43 (8-10) , 1159-1172
A Control Strategy for Hybrid Autonomous Power System with a Battery Management Scheme
This article presents a coordinated control strategy for a hybrid autonomous power system to obtain a smooth power transfer between diesel generator and battery energy storage system under transient conditions. In addition, a battery management scheme is also developed to maintain the battery state of charge around 70 to 80% to absorb/inject power under transient conditions and maintains the diesel generator power above 40% of its nominal value. Simulation studies are carried out in MATLAB/Simulink and the performance of the controller is validated experimentally on a laboratory test setup. A TMS320LF2407A DSP controller is used to digitally implement the control strategy and the overall scheme is verified with step changes in load. Moreover, the dynamic behavior of the system is also investigated by directly connecting an induction motor.
- 11 May 2015
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 43 (8-10) , 1159-1172
A Control Strategy for Hybrid Autonomous Power System with a Battery Management Scheme
This article presents a coordinated control strategy for a hybrid autonomous power system to obtain a smooth power transfer between diesel generator and battery energy storage system under transient conditions. In addition, a battery management scheme is also developed to maintain the battery state of charge around 70 to 80% to absorb/inject power under transient conditions and maintains the diesel generator power above 40% of its nominal value. Simulation studies are carried out in MATLAB/Simulink and the performance of the controller is validated experimentally on a laboratory test setup. A TMS320LF2407A DSP controller is used to digitally implement the control strategy and the overall scheme is verified with step changes in load. Moreover, the dynamic behavior of the system is also investigated by directly connecting an induction motor.
- 10 February 2015
- Published by Springer Nature in Frontiers in Energy
- Vol. 9 (1) , 31-42
A smooth co-ordination control for a hybrid autonomous power system (HAPS) with battery energy storage (BES)
- 10 February 2015
- Published by Springer Nature in Frontiers in Energy
- Vol. 9 (1) , 31-42
A smooth co-ordination control for a hybrid autonomous power system (HAPS) with battery energy storage (BES)
- 3 November 2014
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 42 (16) , 1826-1838
An Energy-efficient Switching Scheme with Reduced Switching Transients for a Wind-driven Induction Generator
This article presents a scheme for improving the power output of grid-connected induction generator commonly used in wind energy conversion systems. Generally, the stator of the induction generator is connected in a star with a line voltage of √3 times the rated winding voltage to reduce the line current and, hence, conductor size. To extend the generating operation over a wider speed range, delta-star switchable stator windings are also in vogue. In such cases, the stator is star connected in the lower speed range and switched to a delta connection above a threshold speed. In this study, a new switching scheme is proposed wherein the stator coils are always connected in a star, while the stator is connected to different voltages in low- and high-speed conditions. At low wind speeds, nominal winding voltage is applied to the stator, whereas at higher speeds, the stator applied voltage is √3 times higher than the rated winding voltage. The efficacy of the scheme is demonstrated experimentally with a suitable microcontroller-based switching arrangement. Typical results indicate an increase in output with reduced switching transients. A case study on a 3-Φ, 50-kW induction generator is presented to emphasize the performance improvement with the proposed scheme.
- 3 November 2014
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 42 (16) , 1826-1838
An Energy-efficient Switching Scheme with Reduced Switching Transients for a Wind-driven Induction Generator
This article presents a scheme for improving the power output of grid-connected induction generator commonly used in wind energy conversion systems. Generally, the stator of the induction generator is connected in a star with a line voltage of √3 times the rated winding voltage to reduce the line current and, hence, conductor size. To extend the generating operation over a wider speed range, delta-star switchable stator windings are also in vogue. In such cases, the stator is star connected in the lower speed range and switched to a delta connection above a threshold speed. In this study, a new switching scheme is proposed wherein the stator coils are always connected in a star, while the stator is connected to different voltages in low- and high-speed conditions. At low wind speeds, nominal winding voltage is applied to the stator, whereas at higher speeds, the stator applied voltage is √3 times higher than the rated winding voltage. The efficacy of the scheme is demonstrated experimentally with a suitable microcontroller-based switching arrangement. Typical results indicate an increase in output with reduced switching transients. A case study on a 3-Φ, 50-kW induction generator is presented to emphasize the performance improvement with the proposed scheme.