Ashraf Maurice Bassily
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ashraf Maurice Bassily has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Gerald M. Colver
Iowa State University, Department of Mechanical Engineering, Ames, IA 50011, U.S.A.
4 shared publicationsG. M. Colver
2 shared publicationsDerrick K. Rollins
Department of Chemical Engineering, 2114 Sweeney Hall, Department of Mechanical Engineering, 2036 Black Engineering, and Department of Statistics, 102 Snedecor Hall, Iowa State University, Ames, Iowa 50011
1 shared publicationNidhi Bhandari
Department of Chemical Engineering, 2114 Sweeney Hall, Department of Mechanical Engineering, 2036 Black Engineering, and Department of Statistics, 102 Snedecor Hall, Iowa State University, Ames, Iowa 50011
1 shared publicationSwee-Teng Chin
Department of Chemical Engineering, 2114 Sweeney Hall, Department of Mechanical Engineering, 2036 Black Engineering, and Department of Statistics, 102 Snedecor Hall, Iowa State University, Ames, Iowa 50011
1 shared publication
Latest Publications
- 14 April 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Modeling, sensitivity analysis, and multi-objective optimization of a humidification-dehumidification-desalination system
Humidification-dehumidification desalination (HDH) is a promising technique that offers a valuable solution to the problem of fresh water shortage. In this paper, an accurate and a complete model that displays all needed expressions for all pressure drops, heat and mass transfer coefficients in the humidifier and dehumidifier and takes into consideration the effects of fouling and salinity of seawater was presented, a local sensitivity analysis was performed to determine the most influential variables for the objective functions of the total cost and gain output ratio (GOR), an innovative design for the dehumidifier that significantly enhances the overall heat transfer coefficient and reduces the pressure drop for water flow was introduced, and optimization problems were formulated through which the total cost of producing fresh water and GOR were optimized separately and simultaneously relative to 10 optimization variables using a genetic algorithm and the direct search method. The main optimization results showed that the HDH system runs at higher temperatures at the minimum cost than that at the optimum GOR and that the average overall heat transfer coefficient in the dehumidifier at the minimum cost is about 5.3 times that at the optimum GOR and that minimizing the total cost reduced the cost at the optimum GOR by 89% and increased its production rate by 121%. Fouling reduced the average overall heat transfer coefficient by 10 to 21% and increased the annual cost. Replacing the copper tubes of the dehumidifier with stainless steel tubes reduced the cost further by 39% at the same production rate. The distributions of the Pareto-optimal point solutions of multi-objective optimization results for the total cost and GOR as a conflict-objective functions were plotted and showed that all points are non-dominated. The consideration of the salinity of seawater shifted the Pareto-optimal point solutions to higher costs and GOR.
- 14 April 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Modeling, sensitivity analysis, and multi-objective optimization of a humidification-dehumidification-desalination system
Humidification-dehumidification desalination (HDH) is a promising technique that offers a valuable solution to the problem of fresh water shortage. In this paper, an accurate and a complete model that displays all needed expressions for all pressure drops, heat and mass transfer coefficients in the humidifier and dehumidifier and takes into consideration the effects of fouling and salinity of seawater was presented, a local sensitivity analysis was performed to determine the most influential variables for the objective functions of the total cost and gain output ratio (GOR), an innovative design for the dehumidifier that significantly enhances the overall heat transfer coefficient and reduces the pressure drop for water flow was introduced, and optimization problems were formulated through which the total cost of producing fresh water and GOR were optimized separately and simultaneously relative to 10 optimization variables using a genetic algorithm and the direct search method. The main optimization results showed that the HDH system runs at higher temperatures at the minimum cost than that at the optimum GOR and that the average overall heat transfer coefficient in the dehumidifier at the minimum cost is about 5.3 times that at the optimum GOR and that minimizing the total cost reduced the cost at the optimum GOR by 89% and increased its production rate by 121%. Fouling reduced the average overall heat transfer coefficient by 10 to 21% and increased the annual cost. Replacing the copper tubes of the dehumidifier with stainless steel tubes reduced the cost further by 39% at the same production rate. The distributions of the Pareto-optimal point solutions of multi-objective optimization results for the total cost and GOR as a conflict-objective functions were plotted and showed that all points are non-dominated. The consideration of the salinity of seawater shifted the Pareto-optimal point solutions to higher costs and GOR.
- 4 March 2026
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 40 (3) , 1-20
Performance Analysis of Water Recovery Heat Exchanger with Novel Design Methodology
There are many models in the literature for heat and mass transfer of vapor condensation in the presence of a non-condensable gas, but most models require the evaluation of three different heat transfer coefficients and input parameters that are usually unknowns and experimentally measured. In this paper, a condensing heat exchanger (CHE) with a new application was introduced for a turbofan aircraft to recover both heat and water and a novel methodology for the design of a CHE that evaluates directly the total heat transfer coefficient for the gas mixture was presented. Such a methodology locates the onset of condensation and does not require any experimental measurements. An air-cooled CHE was divided into 50 sections and the principles of thermodynamics, energy balance, and heat transfer were applied to evaluate the temperatures, properties, length of each section, and the local air and total gas heat transfer coefficients. The results showed that enhancing the overall heat transfer coefficient and reducing the CHE weight could be achieved with a less total pressure drop for the gas and airflows by increasing the air mass velocity at the same mass flow rates of the gas and air when compared with raising the gas velocity at the same mass flow rates of the gas and air.
- 4 March 2026
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 40 (3) , 1-20
Performance Analysis of Water Recovery Heat Exchanger with Novel Design Methodology
There are many models in the literature for heat and mass transfer of vapor condensation in the presence of a non-condensable gas, but most models require the evaluation of three different heat transfer coefficients and input parameters that are usually unknowns and experimentally measured. In this paper, a condensing heat exchanger (CHE) with a new application was introduced for a turbofan aircraft to recover both heat and water and a novel methodology for the design of a CHE that evaluates directly the total heat transfer coefficient for the gas mixture was presented. Such a methodology locates the onset of condensation and does not require any experimental measurements. An air-cooled CHE was divided into 50 sections and the principles of thermodynamics, energy balance, and heat transfer were applied to evaluate the temperatures, properties, length of each section, and the local air and total gas heat transfer coefficients. The results showed that enhancing the overall heat transfer coefficient and reducing the CHE weight could be achieved with a less total pressure drop for the gas and airflows by increasing the air mass velocity at the same mass flow rates of the gas and air when compared with raising the gas velocity at the same mass flow rates of the gas and air.
- 20 November 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 239 (5) , 2635-2653
Performance enhancements and NO x emission reductions using novel exhaust-driven hybrid gas turbine inlet air-cooling techniques
For combined cycles, gas turbine inlet air-cooling (GTIAC) increases the mass flow rates of both air and the generated steam of the heat recovery steam generator and hence power output. The introduction of exhaust gas recirculation (EGR) to reduce NO x emissions necessitates the application of GTIAC to overcome the adverse effects of gas turbine (GT) inlet air heating that accompany EGR. For a hot-humid climate, the r5egular cooling methods consume a significant amount of energy while desiccant and inlet-fogging are not effective. The main purpose of this study is to introduce innovative exhaust-driven hybrid GTIAC techniques that can reduce effectively the inlet temperature of the combined cycle in a hot-humid climate without consuming a substantial amount of energy and examine the effects of applying such techniques on the performance and NO x emissions. In this paper, a thorough analysis for the effect of increasing ambient temperature ( T o ) and relative humidity ( RH o ) on the performance and NO x emissions of the air-cooled GT combined cycle (ACGTCC) is presented and the novel exhaust-driven hybrid (NE-DH) GTIAC systems of desiccant-ejector, ejector-refrigeration, and desiccant-ejector-refrigeration are applied to ACGTCC and optimized for maximum power output. The 1-D model at the double choking was used to model the performance of the ejector GTIAC technique. The results indicate that applying NE-DH GTIAC techniques results in gains in power, which vary between 0.31% and 0.6% per °C rise in T o and an efficiency improvement of up to about 0.5 percentage point and significant reductions in both capital and maintenance costs compared with applying the refrigeration GTIAC system. The introduction of ejector and desiccant cooling decreases NO x emissions further and adds no additional equipment cost if implemented together with EGR or some CO 2 capture techniques. A suggested plan for GTIAC that reduces NO x emissions by up to 25% is presented.
- 20 November 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 239 (5) , 2635-2653
Performance enhancements and NO x emission reductions using novel exhaust-driven hybrid gas turbine inlet air-cooling techniques
For combined cycles, gas turbine inlet air-cooling (GTIAC) increases the mass flow rates of both air and the generated steam of the heat recovery steam generator and hence power output. The introduction of exhaust gas recirculation (EGR) to reduce NO x emissions necessitates the application of GTIAC to overcome the adverse effects of gas turbine (GT) inlet air heating that accompany EGR. For a hot-humid climate, the r5egular cooling methods consume a significant amount of energy while desiccant and inlet-fogging are not effective. The main purpose of this study is to introduce innovative exhaust-driven hybrid GTIAC techniques that can reduce effectively the inlet temperature of the combined cycle in a hot-humid climate without consuming a substantial amount of energy and examine the effects of applying such techniques on the performance and NO x emissions. In this paper, a thorough analysis for the effect of increasing ambient temperature ( T o ) and relative humidity ( RH o ) on the performance and NO x emissions of the air-cooled GT combined cycle (ACGTCC) is presented and the novel exhaust-driven hybrid (NE-DH) GTIAC systems of desiccant-ejector, ejector-refrigeration, and desiccant-ejector-refrigeration are applied to ACGTCC and optimized for maximum power output. The 1-D model at the double choking was used to model the performance of the ejector GTIAC technique. The results indicate that applying NE-DH GTIAC techniques results in gains in power, which vary between 0.31% and 0.6% per °C rise in T o and an efficiency improvement of up to about 0.5 percentage point and significant reductions in both capital and maintenance costs compared with applying the refrigeration GTIAC system. The introduction of ejector and desiccant cooling decreases NO x emissions further and adds no additional equipment cost if implemented together with EGR or some CO 2 capture techniques. A suggested plan for GTIAC that reduces NO x emissions by up to 25% is presented.
- 17 May 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 239 (1) , 376-393
Modeling, performance enhancement, and the NOx emission reductions of the triple-pressure reheat water-recuperated air-cooled gas turbine combined cycle power plant using interstage compressor water injection and optimization
Interstage compressor water injection (ICWI) reduces the work of an air compressor, air temperature at its outlet, adiabatic flame temperature, and NOx emissions. When ICWI is introduced to combined cycles, it decreases the surge margin for the air compressor and increases the mass flow rates of the gas through the gas turbine (GT) and generated steam for the heat recovery steam generator and, therefore, power output. For the combined cycle with ICWI, air with two distinct characteristics (before and after ICWI) is used to cool the GT and mix with the expanded gas. In this paper, ICWI was introduced to the triple-pressure reheat air-cooled GT combined cycle. Detailed modeling was carried out for the processes of compression, ICWI, combustion, and GT expansion. Constraints were imposed on the amount of injected water and its temperature and pressure leading to a practical application of ICWI and a safe surge margin for the air compressor. The efficiency of the combined cycle with ICWI was optimized relative to the pressure of ICWI, injected water temperature, and relative humidity of air at the outlet of the water injector at different values of turbine inlet temperatures and air compression ratios. The results indicated that ICWI and optimization could reduce the initial NOx emissions by more than 90% (the NOx emissions that are produced at the adiabatic flame temperature) and enhance cycle efficiency by 1.9 to 2.7 percentage points and power output by 27 to 34 percent. The water recovery system could produce a significant amount of water that exceeds twice the injected amount at no fuel cost and could be integrated into the cycle at no additional equipment costs if CO2 capture or exhaust gas recirculation was implemented.
- 17 May 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 239 (1) , 376-393
Modeling, performance enhancement, and the NOx emission reductions of the triple-pressure reheat water-recuperated air-cooled gas turbine combined cycle power plant using interstage compressor water injection and optimization
Interstage compressor water injection (ICWI) reduces the work of an air compressor, air temperature at its outlet, adiabatic flame temperature, and NOx emissions. When ICWI is introduced to combined cycles, it decreases the surge margin for the air compressor and increases the mass flow rates of the gas through the gas turbine (GT) and generated steam for the heat recovery steam generator and, therefore, power output. For the combined cycle with ICWI, air with two distinct characteristics (before and after ICWI) is used to cool the GT and mix with the expanded gas. In this paper, ICWI was introduced to the triple-pressure reheat air-cooled GT combined cycle. Detailed modeling was carried out for the processes of compression, ICWI, combustion, and GT expansion. Constraints were imposed on the amount of injected water and its temperature and pressure leading to a practical application of ICWI and a safe surge margin for the air compressor. The efficiency of the combined cycle with ICWI was optimized relative to the pressure of ICWI, injected water temperature, and relative humidity of air at the outlet of the water injector at different values of turbine inlet temperatures and air compression ratios. The results indicated that ICWI and optimization could reduce the initial NOx emissions by more than 90% (the NOx emissions that are produced at the adiabatic flame temperature) and enhance cycle efficiency by 1.9 to 2.7 percentage points and power output by 27 to 34 percent. The water recovery system could produce a significant amount of water that exceeds twice the injected amount at no fuel cost and could be integrated into the cycle at no additional equipment costs if CO2 capture or exhaust gas recirculation was implemented.
- 1 September 2013
- Published by Elsevier in Applied Thermal Engineering
- Vol. 59 (1-2) , 362
Erratum to “Modeling, analysis, and modifications of different GT cooling techniques for modern commercial combined cycle power plants with reducing the irreversibility of the HRSG” [Appl. Therm. Eng. 53 (1) (29 April 2013) 131–146]
- 1 September 2013
- Published by Elsevier in Applied Thermal Engineering
- Vol. 59 (1-2) , 362
Erratum to “Modeling, analysis, and modifications of different GT cooling techniques for modern commercial combined cycle power plants with reducing the irreversibility of the HRSG” [Appl. Therm. Eng. 53 (1) (29 April 2013) 131–146]
- 1 April 2013
- Published by Elsevier in Applied Thermal Engineering
- Vol. 53 (1) , 131-146
Modeling, analysis, and modifications of different GT cooling techniques for modern commercial combined cycle power plants with reducing the irreversibility of the HRSG
- 1 April 2013
- Published by Elsevier in Applied Thermal Engineering
- Vol. 53 (1) , 131-146
Modeling, analysis, and modifications of different GT cooling techniques for modern commercial combined cycle power plants with reducing the irreversibility of the HRSG
- 1 July 2012
- Published by Elsevier in Applied Thermal Engineering
- Vol. 40, 145-160
Numerical cost optimization and irreversibility analysis of the triple-pressure reheat steam-air cooled GT commercial combined cycle power plants
- 1 July 2012
- Published by Elsevier in Applied Thermal Engineering
- Vol. 40, 145-160
Numerical cost optimization and irreversibility analysis of the triple-pressure reheat steam-air cooled GT commercial combined cycle power plants
- 1 December 2008
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 32 (15) , 1399-1417
Cost numerical optimization of the triple-pressure steam-reheat gas-reheat gas-recuperated combined power cycle that uses steam for cooling the first GT
- 1 December 2008
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 32 (15) , 1399-1417
Cost numerical optimization of the triple-pressure steam-reheat gas-reheat gas-recuperated combined power cycle that uses steam for cooling the first GT
- 1 December 2008
- Published by Elsevier in Applied Energy
- Vol. 85 (12) , 1141-1162
Enhancing the efficiency and power of the triple-pressure reheat combined cycle by means of gas reheat, gas recuperation, and reduction of the irreversibility in the heat recovery steam generator
- 1 December 2008
- Published by Elsevier in Applied Energy
- Vol. 85 (12) , 1141-1162
Enhancing the efficiency and power of the triple-pressure reheat combined cycle by means of gas reheat, gas recuperation, and reduction of the irreversibility in the heat recovery steam generator