Hiromu Ishio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hiromu Ishio has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Masaru Miyao
Graduate School of Information Science, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan
16 shared publicationsHiroki Takada
University of Fukui
9 shared publicationsTakehito Kojima
Nagoya University Nagoya Japan
9 shared publicationsMasako Omori
Kobe Women’s University
8 shared publicationsTomoki Shiomi
Graduate School of Information Science Nagoya University Nagoya Japan
7 shared publicationsAkira Hasegawa
6 shared publications
Latest Publications
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6, 107-109
Age-dependence of work efficiency enhancement in information seeking by using see-through smart glasses
Very recently, wearable devices have become popular and recognized as useful tools to assist human activities. Especially, see-through smart glasses, which are featuring the augmented reality (AR) technology, can overlay a virtual image on the real view. One of the major functions of the device is to effectively direct attention to a certain location in the view and there let one read virtually-presented information in relation to the real world as is intended. Our primary research interest is age-dependence of work efficiency enhancement in information seeking with the help of AR by using see-through smart glasses. We report the result of our experimental study, adopting our originally developed Route Tracking Test (RTT) for information seeking. We also discuss a potential application to visual instructions for assembly work in school education.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6, 107-109
Age-dependence of work efficiency enhancement in information seeking by using see-through smart glasses
Very recently, wearable devices have become popular and recognized as useful tools to assist human activities. Especially, see-through smart glasses, which are featuring the augmented reality (AR) technology, can overlay a virtual image on the real view. One of the major functions of the device is to effectively direct attention to a certain location in the view and there let one read virtually-presented information in relation to the real world as is intended. Our primary research interest is age-dependence of work efficiency enhancement in information seeking with the help of AR by using see-through smart glasses. We report the result of our experimental study, adopting our originally developed Route Tracking Test (RTT) for information seeking. We also discuss a potential application to visual instructions for assembly work in school education.
- 17 May 2017
- Published by Springer Nature
- p. 471-482
Temporal Evolution in Potential Functions While Peripheral Viewing Video Clips with/without Backgrounds
- 17 May 2017
- Published by Springer Nature
- p. 471-482
Temporal Evolution in Potential Functions While Peripheral Viewing Video Clips with/without Backgrounds
- 1 January 2017
- Published by Wiley in Journal of the Society for Information Display
- Vol. 25 (1) , 12-19
Measuring the effects of lighting on the readability of electronic devices
The aim of this study was to understand to what extent people can read e‐paper devices under various conditions of ambient illuminance that can occur indoors. In this study, 110 young to elderly subjects participated in an experiment to evaluate the effects of 14 different levels of ambient lighting on their reading from three different electronic devises and paper text. The participants were asked to undergo a timed read task and then to evaluate the readability of two eReader devices (a regular electronic display and one with a front light) in comparison with a backlit liquid crystal device and conventional paper text. The results indicated that backlit and front lit devices are easier to read at less than 200 lx and the reflective device is easier to read at levels above 500 lx.
- 1 January 2017
- Published by Wiley in Journal of the Society for Information Display
- Vol. 25 (1) , 12-19
Measuring the effects of lighting on the readability of electronic devices
The aim of this study was to understand to what extent people can read e‐paper devices under various conditions of ambient illuminance that can occur indoors. In this study, 110 young to elderly subjects participated in an experiment to evaluate the effects of 14 different levels of ambient lighting on their reading from three different electronic devises and paper text. The participants were asked to undergo a timed read task and then to evaluate the readability of two eReader devices (a regular electronic display and one with a front light) in comparison with a backlit liquid crystal device and conventional paper text. The results indicated that backlit and front lit devices are easier to read at less than 200 lx and the reflective device is easier to read at levels above 500 lx.
- 21 June 2016
- Published by Springer Nature
- p. 271-278
Measurement of Lens Focus Adjustment While Wearing a See-Through Head-Mounted Display
- 21 June 2016
- Published by Springer Nature
- p. 271-278
Measurement of Lens Focus Adjustment While Wearing a See-Through Head-Mounted Display
- 1 January 2016
- Published by Japanese Society for Hygiene in Nippon Eiseigaku Zasshi (Japanese Journal of Hygiene)
- Vol. 71 (1) , 12-18
Limits of Cognition with Visual Parallax of Stereoscopic Images
This study concludes that people can cognitively recognize a 3D telop at a 2.0° parallax without feeling fatigued.
- 1 January 2016
- Published by Japanese Society for Hygiene in Nippon Eiseigaku Zasshi (Japanese Journal of Hygiene)
- Vol. 71 (1) , 12-18
Limits of Cognition with Visual Parallax of Stereoscopic Images
This study concludes that people can cognitively recognize a 3D telop at a 2.0° parallax without feeling fatigued.
- 18 July 2015
- Published by Springer Nature
- p. 196-204
A Study on Within-Subject Factors for Visually Induced Motion Sickness by Using 8K Display
- 18 July 2015
- Published by Springer Nature
- p. 196-204
A Study on Within-Subject Factors for Visually Induced Motion Sickness by Using 8K Display
- 1 January 2014
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Electronics, Information and Systems
- Vol. 134 (2) , 212-217
Protruding Recognition for Virtual 3D Telop
- 1 January 2014
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Electronics, Information and Systems
- Vol. 134 (2) , 212-217
Protruding Recognition for Virtual 3D Telop
- 1 March 2013
- Published by Wiley in Journal of the Society for Information Display
- Vol. 21 (3) , 120-128
Simultaneous measurement of lens accommodation and convergence in natural and artificial 3D vision
Recent advances in 3D technology have been accompanied by increasing complaints of visual fatigue. The usual explanation for such fatigue is that accommodation and convergence are mismatched during stereoscopic vision.The aim of this study was to measure fixation distances between lens accommodation and convergence in young subjects while they viewed real objects and 3D video clips. Measurements were made using an original instrument. The 3D video clips were presented to subjects using a liquid crystal shutter glass system. The results showed that when viewing real objects, the diopter values of subjects' accommodation and convergence were similar and changed periodically. This measurement method was thus considered to be appropriate for the measurement of stereoscopic vision. We also investigated lens accommodation and convergence when subjects viewed 3D video clips. Both accommodation and convergence were found to move along with the virtual position of 3D video clips. Therefore, there was little discrepancy between accommodation and convergence during the viewing of 3D images.
- 1 March 2013
- Published by Wiley in Journal of the Society for Information Display
- Vol. 21 (3) , 120-128
Simultaneous measurement of lens accommodation and convergence in natural and artificial 3D vision
Recent advances in 3D technology have been accompanied by increasing complaints of visual fatigue. The usual explanation for such fatigue is that accommodation and convergence are mismatched during stereoscopic vision.The aim of this study was to measure fixation distances between lens accommodation and convergence in young subjects while they viewed real objects and 3D video clips. Measurements were made using an original instrument. The 3D video clips were presented to subjects using a liquid crystal shutter glass system. The results showed that when viewing real objects, the diopter values of subjects' accommodation and convergence were similar and changed periodically. This measurement method was thus considered to be appropriate for the measurement of stereoscopic vision. We also investigated lens accommodation and convergence when subjects viewed 3D video clips. Both accommodation and convergence were found to move along with the virtual position of 3D video clips. Therefore, there was little discrepancy between accommodation and convergence during the viewing of 3D images.
- 1 January 2013
- Published by INSTICC
- p. 542-545
Comparison of Simultaneous Measurement While Viewing Real Objects and 3D Video Clips
- 1 January 2013
- Published by INSTICC
- p. 542-545
Comparison of Simultaneous Measurement While Viewing Real Objects and 3D Video Clips
- 1 January 2013
- Published by Springer Nature
- p. 309-317
Measurement of Lens Accommodation and Convergence during the Viewing of 3D Images
- 1 January 2013
- Published by Springer Nature
- p. 309-317
Measurement of Lens Accommodation and Convergence during the Viewing of 3D Images