Andreas Argubi-Wollesen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Andreas Argubi-Wollesen has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Robert Weidner
University of Innsbruck
4 shared publicationsJens P. Wulfsberg
Laboratory for Manufacturing Technology
3 shared publications- Astrid Zech
Institute of Human Movement Science, University of Hamburg, Hamburg, Germany
2 shared publications - Bettina Wollesen
Institute of Movement Therapy and Movement-oriented Prevention and Rehabilitation, German Sports University Cologne, Cologne, Germany
2 shared publications Klaus Mattes
Department of Human Movement Science and Exercise Science, University of Hamburg, Faculty of Psychology and Human Movement Science, Institute of Human Movement Science, Turmweg, Hamburg, Germany
2 shared publications- Anna Lina Rahlf
Department of Human Movement Science and Exercise Physiology, Institute of Sport Science, Friedrich Schiller University Jena, Jena, Germany
1 shared publication
Latest Publications
- Open Access
The BeMoBIL Pipeline for automated analyses of multimodal mobile brain and body imaging data
Advancements in hardware technology and analysis methods allow more and more mobility in electroencephalography (EEG) experiments. Mobile Brain/Body Imaging (MoBI) studies may record various types of data such as motion or eye tracking in addition to neural activity. Although there are options available to analyze EEG data in a standardized way, they do not fully cover complex multimodal data from mobile experiments. We thus propose the BeMoBIL Pipeline, an easy-to-use pipeline in MATLAB that supports the time-synchronized handling of multimodal data. It is based on EEGLAB and fieldtrip and consists of automated functions for EEG preprocessing and subsequent source separation. It also provides functions for motion data processing and extraction of event markers from different data modalities, including the extraction of eye-movement and gait-related events from EEG using independent component analysis. The pipeline introduces a new robust method for region-of-interest-based group-level clustering of independent EEG components. Finally, the BeMoBIL Pipeline provides analytical visualizations at various processing steps, keeping the analysis transparent and allowing for quality checks of the resulting outcomes. All parameters and steps are documented within the data structure and can be fully replicated using the same scripts. This pipeline makes the processing and analysis of (mobile) EEG and body data more reliable and independent of the prior experience of the individual researchers, thus facilitating the use of EEG in general and MoBI in particular. It is an open-source project available for download at https://github.com/BeMoBIL/bemobil-pipeline which allows for community-driven adaptations in the future.
Open AccessThe BeMoBIL Pipeline for automated analyses of multimodal mobile brain and body imaging data
Advancements in hardware technology and analysis methods allow more and more mobility in electroencephalography (EEG) experiments. Mobile Brain/Body Imaging (MoBI) studies may record various types of data such as motion or eye tracking in addition to neural activity. Although there are options available to analyze EEG data in a standardized way, they do not fully cover complex multimodal data from mobile experiments. We thus propose the BeMoBIL Pipeline, an easy-to-use pipeline in MATLAB that supports the time-synchronized handling of multimodal data. It is based on EEGLAB and fieldtrip and consists of automated functions for EEG preprocessing and subsequent source separation. It also provides functions for motion data processing and extraction of event markers from different data modalities, including the extraction of eye-movement and gait-related events from EEG using independent component analysis. The pipeline introduces a new robust method for region-of-interest-based group-level clustering of independent EEG components. Finally, the BeMoBIL Pipeline provides analytical visualizations at various processing steps, keeping the analysis transparent and allowing for quality checks of the resulting outcomes. All parameters and steps are documented within the data structure and can be fully replicated using the same scripts. This pipeline makes the processing and analysis of (mobile) EEG and body data more reliable and independent of the prior experience of the individual researchers, thus facilitating the use of EEG in general and MoBI in particular. It is an open-source project available for download at https://github.com/BeMoBIL/bemobil-pipeline which allows for community-driven adaptations in the future.
- 31 October 2018
- Published by Springer Nature
- p. 47-61
Biomechanical Analysis: Adapting to Users’ Physiological Preconditions and Demands
- 31 October 2018
- Published by Springer Nature
- p. 47-61
Biomechanical Analysis: Adapting to Users’ Physiological Preconditions and Demands
- 26 September 2017
- Published by Springer Nature in Production Engineering
- Vol. 11 (6) , 731-743
Biomimetic design of an ultra-compact and light-weight soft muscle glove
- 26 September 2017
- Published by Springer Nature in Production Engineering
- Vol. 11 (6) , 731-743
Biomimetic design of an ultra-compact and light-weight soft muscle glove
- 1 August 2017
- Published by Walter de Gruyter GmbH in i-com
- Vol. 16 (2) , 143-152
Human-Machine Integration as Support Relation: Individual and Task-Related Hybrid Systems in Industrial Production
One of the greatest societal challenges right now can be seen in the design of the interaction between human and technology. Especially in recent years this has become more intense. In almost all life situations, we are already supported or assisted by technology. Such systems come in various forms and characteristics. This paper will report on an ongoing research project named smartASSIST which aims to establish methods for the development of wearable systems for physical support as well as exemplary supporting technologies. The research is based upon a theoretical foundation of human-machine support relations which leads to the conceptual approach of constructing Human-Hybrid-Robot (HHR) systems.
- 1 August 2017
- Published by Walter de Gruyter GmbH in i-com
- Vol. 16 (2) , 143-152
Human-Machine Integration as Support Relation: Individual and Task-Related Hybrid Systems in Industrial Production
One of the greatest societal challenges right now can be seen in the design of the interaction between human and technology. Especially in recent years this has become more intense. In almost all life situations, we are already supported or assisted by technology. Such systems come in various forms and characteristics. This paper will report on an ongoing research project named smartASSIST which aims to establish methods for the development of wearable systems for physical support as well as exemplary supporting technologies. The research is based upon a theoretical foundation of human-machine support relations which leads to the conceptual approach of constructing Human-Hybrid-Robot (HHR) systems.
- Open Access
- 1 March 2017
- Published by Elsevier in Safety and Health at Work
- Vol. 8 (1) , 11-18
Human Body Mechanics of Pushing and Pulling: Analyzing the Factors of Task-related Strain on the Musculoskeletal System
- 1 March 2017
- Published by Elsevier in Safety and Health at Work
- Vol. 8 (1) , 11-18
Open AccessHuman Body Mechanics of Pushing and Pulling: Analyzing the Factors of Task-related Strain on the Musculoskeletal System
- 1 June 2016
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 840, 123-131
Towards a Modular and Wearable Support System for Industrial Production
Despite the increasing degree of automation many tasks are still performed manually, especially in production of individualized, sensitive or quality critical products. These tasks, e.g. tasks in or above head level, are often non ergonomic. Thus musculoskeletal diseases can occur. This paper presents a novel concept for a modular and wearable technical support system for reducing musculoskeletal stress. The support system which is based on the approach of Human Hybrid Robot (HHR) can be adapted easily to different users and activities. The system emphasizes on modularity and the use of soft materials for kinematic elements and interfaces in order to gain higher flexibility and increased human safety. The basic idea can be applied to various applications. The focus lies on a functional support system prototype for upper extremities. It comprises a Human-Machine-Interface using a vest equipped with soft kinematic elements as well as a control unit. Moreover, results from a biomechanical case study will be illustrated in order to confirm the ergonomic improvements, especially the comparison of the range of motion and the musculoskeletal stress during tasks.
- 1 June 2016
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 840, 123-131
Towards a Modular and Wearable Support System for Industrial Production
Despite the increasing degree of automation many tasks are still performed manually, especially in production of individualized, sensitive or quality critical products. These tasks, e.g. tasks in or above head level, are often non ergonomic. Thus musculoskeletal diseases can occur. This paper presents a novel concept for a modular and wearable technical support system for reducing musculoskeletal stress. The support system which is based on the approach of Human Hybrid Robot (HHR) can be adapted easily to different users and activities. The system emphasizes on modularity and the use of soft materials for kinematic elements and interfaces in order to gain higher flexibility and increased human safety. The basic idea can be applied to various applications. The focus lies on a functional support system prototype for upper extremities. It comprises a Human-Machine-Interface using a vest equipped with soft kinematic elements as well as a control unit. Moreover, results from a biomechanical case study will be illustrated in order to confirm the ergonomic improvements, especially the comparison of the range of motion and the musculoskeletal stress during tasks.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15301605,p. 542-550
A Novel Concept for Wearable, Modular and Soft Support Systems Used in Industrial Environments
This paper presents a novel concept for wearable support systems based on the approach of the Human Hybrid Robot (HHR), which can be adapted easily to the user and the activity. The concept focuses on modularity and makes intensive use of new manufacturing technologies like 3D-printing as well as flexible kinematics and textile components, in order to fit the system to different individuals and tasks as well as to increase human safety. The main idea can be applied to various applications. In this paper we are focusing on a functional exoskeleton prototype for the upper extremities. It comprises a Human-Machine-Interface (HMI) using a glove equipped with haptic sensors to measure grip force as well as force sensors in a coupling to the user at the forearm. This functional prototype was then successfully evaluated in a blind study with 20 test subjects.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15301605,p. 542-550
A Novel Concept for Wearable, Modular and Soft Support Systems Used in Industrial Environments
This paper presents a novel concept for wearable support systems based on the approach of the Human Hybrid Robot (HHR), which can be adapted easily to the user and the activity. The concept focuses on modularity and makes intensive use of new manufacturing technologies like 3D-printing as well as flexible kinematics and textile components, in order to fit the system to different individuals and tasks as well as to increase human safety. The main idea can be applied to various applications. In this paper we are focusing on a functional exoskeleton prototype for the upper extremities. It comprises a Human-Machine-Interface (HMI) using a glove equipped with haptic sensors to measure grip force as well as force sensors in a coupling to the user at the forearm. This functional prototype was then successfully evaluated in a blind study with 20 test subjects.
- Open Access
- 26 May 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (5) , e0125880
Comparison of Minimalist Footwear Strategies for Simulating Barefoot Running: A Randomized Crossover Study
Possible benefits of barefoot running have been widely discussed in recent years. Uncertainty exists about which footwear strategy adequately simulates barefoot running kinematics. The objective of this study was to investigate the effects of athletic footwear with different minimalist strategies on running kinematics. Thirty-five distance runners (22 males, 13 females, 27.9 ± 6.2 years, 179.2 ± 8.4 cm, 73.4 ± 12.1 kg, 24.9 ± 10.9 km.week-1) performed a treadmill protocol at three running velocities (2.22, 2.78 and 3.33 m.s-1) using four footwear conditions: barefoot, uncushioned minimalist shoes, cushioned minimalist shoes, and standard running shoes. 3D kinematic analysis was performed to determine ankle and knee angles at initial foot-ground contact, rate of rear-foot strikes, stride frequency and step length. Ankle angle at foot strike, step length and stride frequency were significantly influenced by footwear conditions (p-1), followed by running with uncushioned minimalist shoes (62.9%), cushioned minimalist (88.6%) and standard shoes (94.3%). Aside from showing the influence of shod conditions on running kinematics, this study helps to elucidate differences between footwear marked as minimalist shoes and their ability to mimic barefoot running adequately. These findings have implications on the use of footwear applied in future research debating the topic of barefoot or minimalist shoe running.
- 26 May 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (5) , e0125880
Open AccessComparison of Minimalist Footwear Strategies for Simulating Barefoot Running: A Randomized Crossover Study
Possible benefits of barefoot running have been widely discussed in recent years. Uncertainty exists about which footwear strategy adequately simulates barefoot running kinematics. The objective of this study was to investigate the effects of athletic footwear with different minimalist strategies on running kinematics. Thirty-five distance runners (22 males, 13 females, 27.9 ± 6.2 years, 179.2 ± 8.4 cm, 73.4 ± 12.1 kg, 24.9 ± 10.9 km.week-1) performed a treadmill protocol at three running velocities (2.22, 2.78 and 3.33 m.s-1) using four footwear conditions: barefoot, uncushioned minimalist shoes, cushioned minimalist shoes, and standard running shoes. 3D kinematic analysis was performed to determine ankle and knee angles at initial foot-ground contact, rate of rear-foot strikes, stride frequency and step length. Ankle angle at foot strike, step length and stride frequency were significantly influenced by footwear conditions (p-1), followed by running with uncushioned minimalist shoes (62.9%), cushioned minimalist (88.6%) and standard shoes (94.3%). Aside from showing the influence of shod conditions on running kinematics, this study helps to elucidate differences between footwear marked as minimalist shoes and their ability to mimic barefoot running adequately. These findings have implications on the use of footwear applied in future research debating the topic of barefoot or minimalist shoe running.
- 10 July 2014
- Published by Wiley in European Journal of Sport Science
- Vol. 15 (4) , 279-285
Minimalist, standard and no footwear on static and dynamic postural stability following jump landing
In recreational sports, uncushioned, light‐weight and minimalist shoes are increasingly used to imitate barefoot situations. Uncertainty exists whether these shoes provide sufficient stability during challenging movements. In this randomised crossover study, 35 healthy distance runners performed jump landing stabilisation and single‐leg stance tests on a force plate, using four conditions in random order: barefoot, uncushioned minimalist shoes, cushioned ultraflexible shoes and standard running shoes. Ground reaction force (GRF) and centre of pressure (COP) data were used to determine unilateral jump landing stabilisation time and COP sway velocity during single‐leg stance. Repeated measures analysis of variance revealed significant footwear interactions for medial–lateral (p < 0.001) and anterior–posterior COP sway velocity during standing (p < 0.001). The barefoot condition produced significantly greater postural sway velocities (p < 0.001) compared to all footwear conditions. No significant effects were found for jump landing stabilisation time. In conclusion, the results of this study indicate that increased shoe flexibility and reduced sole support have no, or only minor influence on static and dynamic postural control, and therefore, may not increase the risk of traumatic events during sports activities. However, barefoot conditions should be considered carefully when adequate postural control is needed.
- 10 July 2014
- Published by Wiley in European Journal of Sport Science
- Vol. 15 (4) , 279-285
Minimalist, standard and no footwear on static and dynamic postural stability following jump landing
In recreational sports, uncushioned, light‐weight and minimalist shoes are increasingly used to imitate barefoot situations. Uncertainty exists whether these shoes provide sufficient stability during challenging movements. In this randomised crossover study, 35 healthy distance runners performed jump landing stabilisation and single‐leg stance tests on a force plate, using four conditions in random order: barefoot, uncushioned minimalist shoes, cushioned ultraflexible shoes and standard running shoes. Ground reaction force (GRF) and centre of pressure (COP) data were used to determine unilateral jump landing stabilisation time and COP sway velocity during single‐leg stance. Repeated measures analysis of variance revealed significant footwear interactions for medial–lateral (p < 0.001) and anterior–posterior COP sway velocity during standing (p < 0.001). The barefoot condition produced significantly greater postural sway velocities (p < 0.001) compared to all footwear conditions. No significant effects were found for jump landing stabilisation time. In conclusion, the results of this study indicate that increased shoe flexibility and reduced sole support have no, or only minor influence on static and dynamic postural control, and therefore, may not increase the risk of traumatic events during sports activities. However, barefoot conditions should be considered carefully when adequate postural control is needed.
- 1 May 2011
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 43 (5) , 313
The Effect of Medical Compression-Sock on Fatigue Resistance
- 1 May 2011
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 43 (5) , 313
The Effect of Medical Compression-Sock on Fatigue Resistance