TNThu-Mai Nguyen

Thu-Mai Nguyen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thu-Mai Nguyen has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Stromal striae: a new insight into corneal physiology and mechanics

    by Kate Grieve, Djida Ghoubay, Cristina Georgeon, Gael Latour, Amir Nahas, Karsten Plamann, Caroline Crotti, Romain Bocheux, Marie Borderie, Thu-Mai Nguyen, et al.

    We uncover the significance of a previously unappreciated structural feature in corneal stroma, important to its biomechanics. Vogt striae are a known clinical indicator of keratoconus, and consist of dark, vertical lines crossing the corneal depth. However we detected stromal striae in most corneas, not only keratoconus. We observed striae with multiple imaging modalities in 82% of 118 human corneas, with pathology-specific differences. Striae generally depart from anchor points at Descemet’s membrane in the posterior stroma obliquely in a V-shape, whereas in keratoconus, striae depart vertically from posterior toward anterior stroma. Optical coherence tomography shear wave elastography showed discontinuity of rigidity, and second harmonic generation and scanning electron microscopies showed undulation of lamellae at striae locations. Striae visibility decreased beyond physiological pressure and increased beyond physiological hydration. Immunohistology revealed striae to predominantly contain collagen VI, lumican and keratocan. The role of these regions of collagen VI linking sets of lamellae may be to absorb increases in intraocular pressure and external shocks.


  • Diffuse shear wave imaging: toward passive elastography using low-frame rate spectral-domain optical coherence tomography

    by Thu-Mai Nguyen, Ali Zorgani, Maxime Lescanne, Claude Boccara, Mathias Fink, Stefan Catheline

    Optical coherence tomography (OCT) can map the stiffness of biological tissue by imaging mechanical perturbations (shear waves) propagating in the tissue. Most shear wave elastography (SWE) techniques rely on active shear sources to generate controlled displacements that are tracked at ultrafast imaging rates. Here, we propose a noise-correlation approach to retrieve stiffness information from the imaging of diffuse displacement fields using low-frame rate spectral-domain OCT. We demonstrated the method on tissue-mimicking phantoms and validated the results by comparison with classic ultrafast SWE. Then we investigated the in vivo feasibility on the eye of an anesthetized rat by applying noise correlation to naturally occurring displacements. The results suggest a great potential for passive elastography based on the detection of natural pulsatile motions using conventional spectral-domain OCT systems. This would facilitate the transfer of OCT-elastography to clinical practice, in particular, in ophthalmology or dermatology.


  • Open Access

    Moving-source elastic wave reconstruction for high-resolution optical coherence elastography

    by Bao-Yu Hsieh, Shaozhen Song, Thu-Mai Nguyen, Soon Joon Yoon, Tueng T. Shen, Ruikang K. Wang, Matthew O’dOnnell

    Optical coherence tomography (OCT)-based elasticity imaging can map soft tissue elasticity based on speckle-tracking of elastic wave propagation using highly sensitive phase measurements of OCT signals. Using a fixed elastic wave source and moving detection, current imaging sequences have difficulty in reconstructing tissue elasticity within speckle-free regions, for example, within the crystalline lens of the eye. We present a moving acoustic radiation force imaging sequence to reconstruct elastic properties within a speckle-free region by tracking elastic wave propagation from multiple laterally moving sources across the field of view. We demonstrate the proposed strategy using heterogeneous and partial speckle-free tissue-mimicking phantoms. Harder inclusions within the speckle-free region can be detected, and the contrast-to-noise ratio slightly enhanced compared to current OCE imaging sequences. The results suggest that a moving source approach may be appropriate for OCE studies within the large speckle-free regions of the crystalline lens.


  • Open Access

    Sono-photoacoustic imaging of gold nanoemulsions: Part II. Real time imaging

    by Bastien Arnal, Chen-Wei Wei, Camilo Perez, Thu-Mai Nguyen, Michael Lombardo, Ivan Pelivanov, Lilo D. Pozzo, Matthew O’dOnnell


  • Magneto-Optical Nanoparticles for Cyclic Magnetomotive Photoacoustic Imaging

    by Junwei Li, Bastien Arnal, Chen-Wei Wei, Jing Shang, Thu-Mai Nguyen, Matthew O’dOnnell, Xiaohu Gao

    Photoacoustic imaging has emerged as a highly promising tool to visualize molecular events with deep tissue penetration. Like most other modalities, however, image contrast under in vivo conditions is far from optimal due to background signals from tissue. Using iron oxide–gold core–shell nanoparticles, we have previously demonstrated the concept of magnetomotive photoacoustic (mmPA) imaging, which is capable of dramatically reducing the influence of background signals and producing high-contrast molecular images. Here, we report two significant advances toward clinical translation of this technology. First, we introduce a new class of compact, uniform, magneto-optically coupled core–shell nanoparticles, prepared through localized copolymerization of polypyrrole (PPy) on an iron oxide nanoparticle surface. The resulting iron oxide–PPy nanoparticles feature high colloidal stability and solve the photoinstability and small-scale synthesis problems previously encountered by the gold coating approach. In parallel, we have developed a new generation of mmPA featuring cyclic magnetic motion and ultrasound speckle tracking (USST), whose imaging capture frame rate is several hundred times faster than the photoacoustic speckle tracking (PAST) method we demonstrated previously. These advances enable robust artifact elimination caused by physiologic motions and demonstrate the application of the mmPA technology for in vivo sensitive tumor imaging.


  • Real-time integrated photoacoustic and ultrasound (PAUS) imaging system to guide interventional procedures: ex vivo study

    by Chen-Wei Wei, Thu-Mai Nguyen, Jinjun Xia, Bastien Arnal, Emily Y. Wong, Ivan M. Pelivanov, Matthew O'Donnell

    Because of depth-dependent light attenuation, bulky, low-repetition-rate lasers are usually used in most photoacoustic (PA) systems to provide sufficient pulse energies to image at depth within the body. However, integrating these lasers with real-time clinical ultrasound (US) scanners has been problematic because of their size and cost. In this paper, an integrated PA/US (PAUS) imaging system is presented operating at frame rates >30 Hz. By employing a portable, low-cost, low-pulse-energy (~2 mJ/pulse), high-repetition-rate (~1 kHz), 1053-nm laser, and a rotating galvo-mirror system enabling rapid laser beam scanning over the imaging area, the approach is demonstrated for potential applications requiring a few centimeters of penetration. In particular, we demonstrate here real-time (30 Hz frame rate) imaging (by combining multiple single-shot sub-images covering the scan region) of an 18-gauge needle inserted into a piece of chicken breast with subsequent delivery of an absorptive agent at more than 1-cm depth to mimic PAUS guidance of an interventional procedure. A signal-to-noise ratio of more than 35 dB is obtained for the needle in an imaging area 2.8 × 2.8 cm (depth × lateral). Higher frame rate operation is envisioned with an optimized scanning scheme.


  • Open Access

    Shear wave elastography using amplitude-modulated acoustic radiation force and phase-sensitive optical coherence tomography

    by Thu-Mai Nguyen, Bastien Arnal, Shaozhen Song, Zhihong Huang, Ruikang K. Wang, Matthew O’dOnnell

    Investigating the elasticity of ocular tissue (cornea and intraocular lens) could help the understanding and management of pathologies related to biomechanical deficiency. In previous studies, we introduced a setup based on optical coherence tomography for shear wave elastography (SWE) with high resolution and high sensitivity. SWE determines tissue stiffness from the propagation speed of shear waves launched within tissue. We proposed acoustic radiation force to remotely induce shear waves by focusing an ultrasound (US) beam in tissue, similar to several elastography techniques. Minimizing the maximum US pressure is essential in ophthalmology for safety reasons. For this purpose, we propose a pulse compression approach. It utilizes coded US emissions to generate shear waves where the energy is spread over a long emission, and then numerically compressed into a short, localized, and high-energy pulse. We used a 7.5-MHz single-element focused transducer driven by coded excitations where the amplitude is modulated by a linear frequency-swept square wave (1 to 7 kHz). An inverse filter approach was used for compression. We demonstrate the feasibility of performing shear wave elastography measurements in tissue-mimicking phantoms at low US pressures (mechanical index <0.6).


  • Toric focusing for radiation force applications using a toric lens coupled to a spherically focused transducer

    by Bastien Arnal, Thu-Mai Nguyen, Matthew O'DOnnell

    Dynamic elastography using radiation force requires that an ultrasound field be focused during hundreds of microseconds at a pressure of several megapascals. Here, we address the importance of the focal geometry. Although there is usually no control of the elevational focal width in generating a tissue mechanical response, we propose a tunable approach to adapt the focus geometry that can significantly improve radiation force efficiency. Several thin, in-house-made polydimethylsiloxane lenses were designed to modify the focal spot of a spherical transducer. They exhibited low absorption and the focal spot widths were extended up to 8-fold in the elevation direction. Radiation force experiments demonstrated an 8-fold increase in tissue displacements using the same pressure level in a tissue-mimicking phantom with a similar shear wave spectrum, meaning it does not affect elastography resolution. Our results demonstrate that larger tissue responses can be obtained for a given pressure level, or that similar response can be reached at a much lower mechanical index (MI). We envision that this work will impact 3-D elastography using 2-D phased arrays, where such shaping can be achieved electronically with the potential for adaptive optimization.


  • In Vivo Evidence of Porcine Cornea Anisotropy Using Supersonic Shear Wave Imaging

    by Thu-Mai Nguyen, Jean-Francois Aubry, Mathias Fink, Jeremy Bercoff, Mickael Tanter

    Purpose: This work proposes shear wave elastography to quantify the elastic anisotropy of the cornea. Methods: Experiments were conducted on enucleated porcine eyeballs and anesthetized swine. We used the Supersonic Shear wave Imaging (SSI) method implemented on a dedicated 15 MHz rotating linear ultrasound array. This setup allows determining the shear wave speed variations for a set of radial propagation directions. Results: All the results showed a local anisotropy with one main direction of maximal stiffness. The influence of pulsatility was observed in vivo and ECG gating was consequently performed for all anesthetized swine. On ex vivo corneas, we performed N = 27 acquisitions in the limbus region, where the collagen fibrils are reported to run tangentially to the sclera. It was shown a good match between the direction of maximal stiffness and the expected direction of the collagen fibrils. Conclusions: This preliminary study demonstrates the potential of SSI for the assessment of corneal anisotropy in both ex vivo and in vivo conditions.


  • Open Access

    Feasibility of a hybrid elastographic-microfluidic device to rapidly process and assess pancreatic cancer biopsies for pathologists

    by Ronnie Das, Thu-Mai Nguyen, Saniel D. Lim, Matt O'Donnell, Ruikang K. Wang, Eric J. Seibel

    In this study, our collaborative research group explored the possibility of incorporating ultrasound elastography technology with a microfluidic device that is designed to prepare fine needle core biopsies (CBs; L=0.5-2.0 cm, D=0.4-1.2 mm) for pancreatic cancer diagnosis. For the first time, elastographic techniques were employed to measure shear wave velocity in fresh (3.7 m/s) and formalin-fixed (14.7 m/s) pancreatic CBs. Shear wave velocity did not vary whether fixed specimens were free on a microscope slide, or constrained within glass microfluidic channels: 11.5±1.9 v. 11.8±2.1 m/s. 4% agarose inclusions were also embedded within 1% agarose hydrogels to simulate cysts, neoplastic, or necrotic tissue within CBs. Inclusions were successfully visualized and measured using optical coherence elastography. These preliminary experiments demonstrate in a rudimentary fashion that elastographic measurements of pancreatic CBs may be incorporated with our microfluidic device. The rapid mapping of CB stiffness may provide qualitative spatial information for pathologists to determine a more accurate diagnosis for patients.