Jerzy Gagan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jerzy Gagan has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Dariusz Butrymowicz
Department of Thermal Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland
25 shared publications - Kamil Śmierciew
Department of Thermal Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland
23 shared publications - Jarosław Karwacki
The Szewalski Institute of Fluid-Flow Machinery Polish Academy of Sciences Fiszera 14 80-231 Gdańsk Poland
7 shared publications - Adam Dudar
Department of Thermal Engineering , Faculty of Mechanical Engineering, Bialystok University of Technology , Wiejska 45C, 15-351 , Bialystok , Poland
4 shared publications Michał Łukaszuk
3 shared publications- Michał Łukaszuk
Faculty of Mechanical Engineering, Białystok University of Technology, 15-351 Bialystok, Poland
3 shared publications
Latest Publications
- 9 September 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 180, 183-198
Validation of R1336mzz(Z) ejector performance in refrigeration systems using transformed R123 data
- 9 September 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 180, 183-198
Validation of R1336mzz(Z) ejector performance in refrigeration systems using transformed R123 data
- 12 February 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 173, 111-122
Experimental assessment of two-phase nozzle performance for low-GWP refrigerants
- 12 February 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 173, 111-122
Experimental assessment of two-phase nozzle performance for low-GWP refrigerants
- Open Access
- 23 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (4) , 429
Design and Manufacture of a Micro-Ejector and the Testing Stand for Investigation of Micro-Ejector Refrigeration Systems
This paper describes the procedure of design and manufacture of a micro-ejector proposed for miniature ejection refrigeration systems. It describes the procedure of design, fabrication, and experimentation on supersonic micro-ejectors and makes the case for isobutane as a working fluid for such systems. It was demonstrated that it is possible to design and fabricate a micro-ejector with a cooling capacity of approximately 3 W. The discussed micro-ejector was driven by a heat source with temperature below 60 °C. The evaporation temperature was approximately 15 °C. For these operating parameters, the reported entrainment ratio was approximately 0.20. The difficulties in fabricating the micro-ejector due to its small dimensions are discussed in the paper. Additionally, the potential difficulties and solutions related to ensuring and maintaining stable operation of the testing stand are presented. The performance of the proposed system is demonstrated and discussed, including relations between mass entrainment ratio, compression ratio, cooling capacity, and temperature.
- 23 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (4) , 429
Open AccessDesign and Manufacture of a Micro-Ejector and the Testing Stand for Investigation of Micro-Ejector Refrigeration Systems
This paper describes the procedure of design and manufacture of a micro-ejector proposed for miniature ejection refrigeration systems. It describes the procedure of design, fabrication, and experimentation on supersonic micro-ejectors and makes the case for isobutane as a working fluid for such systems. It was demonstrated that it is possible to design and fabricate a micro-ejector with a cooling capacity of approximately 3 W. The discussed micro-ejector was driven by a heat source with temperature below 60 °C. The evaporation temperature was approximately 15 °C. For these operating parameters, the reported entrainment ratio was approximately 0.20. The difficulties in fabricating the micro-ejector due to its small dimensions are discussed in the paper. Additionally, the potential difficulties and solutions related to ensuring and maintaining stable operation of the testing stand are presented. The performance of the proposed system is demonstrated and discussed, including relations between mass entrainment ratio, compression ratio, cooling capacity, and temperature.
- 15 July 2023
- Published by Elsevier in Journal of Cleaner Production
- Vol. 418
Flue gas cleaning approach based on jet reactor prototype research
- 15 July 2023
- Published by Elsevier in Journal of Cleaner Production
- Vol. 418
Flue gas cleaning approach based on jet reactor prototype research
- Open Access
- 1 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14249
Investigations of Performance of Mini-Channel Condensers and Evaporators for Propane
This paper provides the results of experimental investigations of the exemplary mini-channel heat exchanger in its application as a condenser and an evaporator in a compressor refrigeration system with propane as a working fluid. The aim of the investigations was to identify the mean heat transfer coefficient of the refrigerant side for the entire operating range of the tested heat exchanger. The experiments covered a mass velocity range from 50 to 160 kg/(m2 × s). The experiments covered a range of liquid subcooling in the condenser from 3 to 15 K and a range of vapour superheating at the outlet of the evaporator from 3 up to 15 K. The experiments on the condenser were conducted at the saturation temperature of 34 °C, and in the case of the evaporator, at the saturation temperature of 8 °C. The average heat transfer coefficients as well as pressure drops in the case of the operation of the tested heat exchanger as an evaporator and condenser were calculated. The heat transfer coefficient was calculated by means of the separated thermal resistance method with the application of the Wilson plot technique. The experiments confirmed the increase in the heat transfer coefficient with the increase in the refrigerant mass flow rate for the tested mini-channel heat exchanger. A dimensionless correlation was proposed for the pressure drop based on the modified Müller-Steinhagen correlation in the case of the operation of the mini-channel heat exchanger as a condenser and as an evaporator.
- 1 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14249
Open AccessInvestigations of Performance of Mini-Channel Condensers and Evaporators for Propane
This paper provides the results of experimental investigations of the exemplary mini-channel heat exchanger in its application as a condenser and an evaporator in a compressor refrigeration system with propane as a working fluid. The aim of the investigations was to identify the mean heat transfer coefficient of the refrigerant side for the entire operating range of the tested heat exchanger. The experiments covered a mass velocity range from 50 to 160 kg/(m2 × s). The experiments covered a range of liquid subcooling in the condenser from 3 to 15 K and a range of vapour superheating at the outlet of the evaporator from 3 up to 15 K. The experiments on the condenser were conducted at the saturation temperature of 34 °C, and in the case of the evaporator, at the saturation temperature of 8 °C. The average heat transfer coefficients as well as pressure drops in the case of the operation of the tested heat exchanger as an evaporator and condenser were calculated. The heat transfer coefficient was calculated by means of the separated thermal resistance method with the application of the Wilson plot technique. The experiments confirmed the increase in the heat transfer coefficient with the increase in the refrigerant mass flow rate for the tested mini-channel heat exchanger. A dimensionless correlation was proposed for the pressure drop based on the modified Müller-Steinhagen correlation in the case of the operation of the mini-channel heat exchanger as a condenser and as an evaporator.
- Open Access
- 28 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14029
Experimental Investigations of Flow Boiling Heat Transfer under Near-Critical Pressure for Selected Working Fluids
This paper deals with experimental investigations of flow boiling in tubular ducts of selected refrigerants—R134a, R507A, and R600a—under near-critical pressures. Near-critical boiling is characterised by low specific enthalpy of evaporation. The positive effect of this feature is the fact that only a small amount of heat consumed by Organic Rankine Cycles is at a constant temperature. This allows a lower terminal temperature of the heating fluid and more effective utilisation of heat sources, especially of low-grade heat sources. The experimental investigations covered a heat flux density of 0.4 to 10 kW/m2 and a mass velocity of 60 to 200 kg/(m2·s). The results of the experimental data were compared to the modified heat transfer correlation of Gungor and Winterton, which provices the best fit for the obtained experimental data. The maximum heat transfer coefficient occurred at the two-phase quality—approximately 0.4 for all the tested fluids under high pressure conditions—which may be thought of as a characteristic feature of the boiling process under near-critical conditions. A modified Gungor–Winterton correlation improves prediction accuracy, especially under the lowest (up to 3 kW/m2) and highest (over 7 kW/m2) heat flux densities for all the tested fluids.
- 28 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14029
Open AccessExperimental Investigations of Flow Boiling Heat Transfer under Near-Critical Pressure for Selected Working Fluids
This paper deals with experimental investigations of flow boiling in tubular ducts of selected refrigerants—R134a, R507A, and R600a—under near-critical pressures. Near-critical boiling is characterised by low specific enthalpy of evaporation. The positive effect of this feature is the fact that only a small amount of heat consumed by Organic Rankine Cycles is at a constant temperature. This allows a lower terminal temperature of the heating fluid and more effective utilisation of heat sources, especially of low-grade heat sources. The experimental investigations covered a heat flux density of 0.4 to 10 kW/m2 and a mass velocity of 60 to 200 kg/(m2·s). The results of the experimental data were compared to the modified heat transfer correlation of Gungor and Winterton, which provices the best fit for the obtained experimental data. The maximum heat transfer coefficient occurred at the two-phase quality—approximately 0.4 for all the tested fluids under high pressure conditions—which may be thought of as a characteristic feature of the boiling process under near-critical conditions. A modified Gungor–Winterton correlation improves prediction accuracy, especially under the lowest (up to 3 kW/m2) and highest (over 7 kW/m2) heat flux densities for all the tested fluids.
- Open Access
- 23 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 13731
Image-Analysis-Based Approach for Identification of Air Cooler Heat Transfer Degradation during Frosting Process
Fin-and-tube heat exchangers have been extensively used in many fields, especially in heat, ventilation, air-conditioning, and refrigeration systems. In the case of the operation of a fin-and-tube heat exchanger as an air cooler, frost formation is an important effect that should be taken into account. The frost accumulation process is undesirable since it deteriorates heat transfer due to the insulation of the frost layer as well as causing excessive pressure loss. The analysis of the effect of the frosting process on a fin-and-tube air cooler performance is presented in this paper. Based on long-term experimental investigations applied to the air cooler in a cold storage chamber, the general degradation of the heat exchanger performance is discussed. The influence of frost on the cooling capacity, by-pass factor, and thermal resistance is analysed. The temperature distribution of the air passing through the air cooler before and after the defrosting process is presented and discussed. A method for the assessment of the amount of frost formed at the air cooler surface, based on visualisation of the air cooler during operation and synchronised with the thermal measurements, is developed. The results show that the frosting process causes deterioration of the cooling capacity by up to 40% in the analysed case. Correlation is demonstrated between frost formation and heat transfer degradation in the air cooler.
- 23 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 13731
Open AccessImage-Analysis-Based Approach for Identification of Air Cooler Heat Transfer Degradation during Frosting Process
Fin-and-tube heat exchangers have been extensively used in many fields, especially in heat, ventilation, air-conditioning, and refrigeration systems. In the case of the operation of a fin-and-tube heat exchanger as an air cooler, frost formation is an important effect that should be taken into account. The frost accumulation process is undesirable since it deteriorates heat transfer due to the insulation of the frost layer as well as causing excessive pressure loss. The analysis of the effect of the frosting process on a fin-and-tube air cooler performance is presented in this paper. Based on long-term experimental investigations applied to the air cooler in a cold storage chamber, the general degradation of the heat exchanger performance is discussed. The influence of frost on the cooling capacity, by-pass factor, and thermal resistance is analysed. The temperature distribution of the air passing through the air cooler before and after the defrosting process is presented and discussed. A method for the assessment of the amount of frost formed at the air cooler surface, based on visualisation of the air cooler during operation and synchronised with the thermal measurements, is developed. The results show that the frosting process causes deterioration of the cooling capacity by up to 40% in the analysed case. Correlation is demonstrated between frost formation and heat transfer degradation in the air cooler.