Amr Youssef
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Amr Youssef has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Jerry L. Prince
Johns Hopkins University
3 shared publications - Khaled Z. Abd-Elmoniem
Biomedical and Metabolic Imaging Branch, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland, USA
3 shared publications M. Roselle Abraham
Department of Cardiology, School of Medicine, Johns Hopkins University, Baltimore, M.D., USA
3 shared publicationsTetsuo Sasano
Johns Hopkins University, Baltimore, USA
3 shared publications- Abdelfattah T. Elgendy
Physics Department, Faculty of Science, Ain Shams University, Cairo, Egypt
2 shared publications Albert C. Lardo
From the Department of Radiology (R.L. M.S.J., J.M., F.M.B.), Division of Nuclear Medicine, the Department of Medicine (K.H.S., T.S., A.Y., R.A., A.C.L.), Division of Cardiology, and the Department of Biomedical Engineering (A.C.L.), Johns Hopkins Medical Institutions, Baltimore, Md, and Nuklearmedizinische Klinik und Poliklinik (S.G.N.), Klinikum rechts der Isar der Technischen Universität München, Munich, Germany
2 shared publications
Latest Publications
- 21 December 2019
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 17 (5) , 1001-1011
Which energetically favorable sustainable synthesis of 4-amino-8-azacoumarin ester or 4-hydroxy-3-cyano derivative based on new exact kinetic Arrhenius and DFT stimulation
- 21 December 2019
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 17 (5) , 1001-1011
Which energetically favorable sustainable synthesis of 4-amino-8-azacoumarin ester or 4-hydroxy-3-cyano derivative based on new exact kinetic Arrhenius and DFT stimulation
- 16 August 2019
- Published by Springer Nature in Journal of Mathematical Chemistry
- Vol. 58 (5) , 922-938
Exact solution of Arrhenius equation for non-isothermal kinetics at constant heating rate and n-th order of reaction
- 16 August 2019
- Published by Springer Nature in Journal of Mathematical Chemistry
- Vol. 58 (5) , 922-938
Exact solution of Arrhenius equation for non-isothermal kinetics at constant heating rate and n-th order of reaction
- Open Access
- 1 October 2016
- Published by Elsevier in JACC: Basic To Translational Science
- Vol. 1 (6) , 510-523
The Promise and Challenge of Induced Pluripotent Stem Cells for Cardiovascular Applications
- 1 October 2016
- Published by Elsevier in JACC: Basic To Translational Science
- Vol. 1 (6) , 510-523
Open AccessThe Promise and Challenge of Induced Pluripotent Stem Cells for Cardiovascular Applications
- Open Access
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 1
Assessment of distribution and evolution of Mechanical dyssynchrony in a porcine model of myocardial infarction by cardiovascular magnetic resonance
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 1
Open AccessAssessment of distribution and evolution of Mechanical dyssynchrony in a porcine model of myocardial infarction by cardiovascular magnetic resonance
- Open Access
- 21 January 2010
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 12 (S1) , P153
Visualization of infarction using fractional anisotropy
- 21 January 2010
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 12 (S1) , P153
Open AccessVisualization of infarction using fractional anisotropy
- 1 January 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (19457928) , 468-471
Identification of myocardial infarction using three-dimensional strain tensor fractional anisotropy
Accurate localization of myocardial viability is important in diagnosis of infarction. Regional strain function provides excessive information for clinical decision making but comparison of strain tensor profiles across differing tissue types is usually difficult due to multi-variate nature of tensors. It is desirable to describe tensors with simplified scalar indices which are more mathematically and statistically intuitive. In this work, anisotropy of tensors in healthy and experimental infarct regions in a large animal model is assessed and compared to directional components of strain tensors which are currently the most popular indices in active use. Myocardial strain tensors are computed using zHARP, a magnetic resonance (MR) tagging technique that provides quantification of cardiac function with direct computation of three-dimensional tensors from two-dimensional short axis MR images. Fractional anisotropy of strain tensors shows high correlation with late gadolinium enhanced images and is capable of discrimination between healthy and infarcted regions.
- 1 January 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (19457928) , 468-471
Identification of myocardial infarction using three-dimensional strain tensor fractional anisotropy
Accurate localization of myocardial viability is important in diagnosis of infarction. Regional strain function provides excessive information for clinical decision making but comparison of strain tensor profiles across differing tissue types is usually difficult due to multi-variate nature of tensors. It is desirable to describe tensors with simplified scalar indices which are more mathematically and statistically intuitive. In this work, anisotropy of tensors in healthy and experimental infarct regions in a large animal model is assessed and compared to directional components of strain tensors which are currently the most popular indices in active use. Myocardial strain tensors are computed using zHARP, a magnetic resonance (MR) tagging technique that provides quantification of cardiac function with direct computation of three-dimensional tensors from two-dimensional short axis MR images. Fractional anisotropy of strain tensors shows high correlation with late gadolinium enhanced images and is capable of discrimination between healthy and infarcted regions.
- 1 July 2009
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 2 (4) , 299-305
Integration of Infarct Size, Tissue Perfusion, and Metabolism by Hybrid Cardiac Positron Emission Tomography/Computed Tomography
Background— Hybrid positron emission tomography/computed tomography (PET-CT) allows for combination of PET perfusion/metabolism imaging with infarct detection by CT delayed contrast enhancement. We used this technique to obtain biomorphological insights into the interrelation between tissue damage, inflammation, and microvascular obstruction early after myocardial infarction. Methods and Results— A porcine model of left anterior descending coronary artery occlusion/reperfusion was studied. Seven animals underwent PET-CT within 3 days of infarction, and a control group of 3 animals was scanned at >4 weeks. Perfusion and glucose uptake were assessed by [ 13 N]-ammonia/[ 18 F]-deoxyglucose (FDG), and 64-slice CT delayed contrast enhancement was measured. In the acute infarct model, CT revealed a no-reflow phenomenon suggesting microvascular obstruction in 80% of all infarct segments. PET showed increased FDG uptake in 68% of the CT-defined infarct segments. Ex vivo staining and histology showed active inflammation in the acute infarct area as an explanation for increased glucose uptake. In chronic infarction, CT showed no microvascular obstruction and agreed well with matched perfusion/metabolism defects on PET. Conclusions— Perfusion/metabolism PET and delayed enhancement CT can be combined within a single hybrid PET-CT session. Increased regional FDG uptake in the acute infarct area is frequently observed. In contrast to the chronic infarct setting, this indicates tissue inflammation that is commonly associated with microvascular obstruction as identified by no reflow on CT. The consequences of these pathophysiological findings for subsequent ventricular remodeling should be explored in further studies.
- 1 July 2009
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 2 (4) , 299-305
Integration of Infarct Size, Tissue Perfusion, and Metabolism by Hybrid Cardiac Positron Emission Tomography/Computed Tomography
Background— Hybrid positron emission tomography/computed tomography (PET-CT) allows for combination of PET perfusion/metabolism imaging with infarct detection by CT delayed contrast enhancement. We used this technique to obtain biomorphological insights into the interrelation between tissue damage, inflammation, and microvascular obstruction early after myocardial infarction. Methods and Results— A porcine model of left anterior descending coronary artery occlusion/reperfusion was studied. Seven animals underwent PET-CT within 3 days of infarction, and a control group of 3 animals was scanned at >4 weeks. Perfusion and glucose uptake were assessed by [ 13 N]-ammonia/[ 18 F]-deoxyglucose (FDG), and 64-slice CT delayed contrast enhancement was measured. In the acute infarct model, CT revealed a no-reflow phenomenon suggesting microvascular obstruction in 80% of all infarct segments. PET showed increased FDG uptake in 68% of the CT-defined infarct segments. Ex vivo staining and histology showed active inflammation in the acute infarct area as an explanation for increased glucose uptake. In chronic infarction, CT showed no microvascular obstruction and agreed well with matched perfusion/metabolism defects on PET. Conclusions— Perfusion/metabolism PET and delayed enhancement CT can be combined within a single hybrid PET-CT session. Increased regional FDG uptake in the acute infarct area is frequently observed. In contrast to the chronic infarct setting, this indicates tissue inflammation that is commonly associated with microvascular obstruction as identified by no reflow on CT. The consequences of these pathophysiological findings for subsequent ventricular remodeling should be explored in further studies.
- 11 April 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 27 (5) , 1012-1018
Real‐time fast strain‐encoded magnetic resonance imaging to evaluate regional myocardial function at 3.0 Tesla: Comparison to conventional tagging
Purpose: To compare the utility of the real‐time technique fast strain‐encoded magnetic resonance imaging (fast‐SENC) for the quantification of regional myocardial function to conventional tagged magnetic resonance imaging (MRI).Materials and Methods: Healthy volunteers (N = 12) and patients with heart failure (N = 7) were examined using tagged MRI and fast‐SENC at 3.0T. Circumferential strain was measured using fast‐SENC in six endo‐ and six subepicardial regions in the basal‐, mid‐, and apical‐septum and the basal‐, mid‐, and apical‐lateral wall from the four‐chamber view. These measurements were plotted to tagging, in corresponding myocardial segments.Results: Peak systolic strain (Ecc) and early diastolic strain rate (Ecc/second) acquired by fast‐SENC correlated closely to tagged MRI (r = 0.90 for Ecc and r = 0.91 for Ecc/second, P < 0.001 for both). Both fast‐SENC and tagging identified differences in regional systolic and diastolic function between normal myocardium and dysfunctional segments in patients with heart failure (for fast‐SENC: Ecc = −21.7 ± 2.7 in healthy volunteers vs. −12.8 ± 4.2 in hypokinetic vs. 0.6 ± 3.8 in akinetic/dyskinetic segments, P < 0.001 between all; Ecc/second = 104 ± 20/second in healthy volunteers vs. 37 ± 9/second in hypokinetic vs. −16 ± 15/second in akinetic/dyskinetic segments, P < 0.001 between all). Quantitative analysis was more time‐consuming for conventional tagging than for fast‐SENC (time‐spent of 3.8 ± 0.7 minutes vs. 9.5 ± 0.7 minutes per patient, P < 0.001).Conclusion: Fast‐SENC allows the rapid and accurate quantification of regional myocardial function. The information derived from fast‐SENC during a single heartbeat seems to be superior or equal to that acquired by conventional tagging during several heart cycles and prolonged breathholds. J. Magn. Reson. Imaging 2008.
- 11 April 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 27 (5) , 1012-1018
Real‐time fast strain‐encoded magnetic resonance imaging to evaluate regional myocardial function at 3.0 Tesla: Comparison to conventional tagging
Purpose: To compare the utility of the real‐time technique fast strain‐encoded magnetic resonance imaging (fast‐SENC) for the quantification of regional myocardial function to conventional tagged magnetic resonance imaging (MRI).Materials and Methods: Healthy volunteers (N = 12) and patients with heart failure (N = 7) were examined using tagged MRI and fast‐SENC at 3.0T. Circumferential strain was measured using fast‐SENC in six endo‐ and six subepicardial regions in the basal‐, mid‐, and apical‐septum and the basal‐, mid‐, and apical‐lateral wall from the four‐chamber view. These measurements were plotted to tagging, in corresponding myocardial segments.Results: Peak systolic strain (Ecc) and early diastolic strain rate (Ecc/second) acquired by fast‐SENC correlated closely to tagged MRI (r = 0.90 for Ecc and r = 0.91 for Ecc/second, P < 0.001 for both). Both fast‐SENC and tagging identified differences in regional systolic and diastolic function between normal myocardium and dysfunctional segments in patients with heart failure (for fast‐SENC: Ecc = −21.7 ± 2.7 in healthy volunteers vs. −12.8 ± 4.2 in hypokinetic vs. 0.6 ± 3.8 in akinetic/dyskinetic segments, P < 0.001 between all; Ecc/second = 104 ± 20/second in healthy volunteers vs. 37 ± 9/second in hypokinetic vs. −16 ± 15/second in akinetic/dyskinetic segments, P < 0.001 between all). Quantitative analysis was more time‐consuming for conventional tagging than for fast‐SENC (time‐spent of 3.8 ± 0.7 minutes vs. 9.5 ± 0.7 minutes per patient, P < 0.001).Conclusion: Fast‐SENC allows the rapid and accurate quantification of regional myocardial function. The information derived from fast‐SENC during a single heartbeat seems to be superior or equal to that acquired by conventional tagging during several heart cycles and prolonged breathholds. J. Magn. Reson. Imaging 2008.
- 25 March 2008
- Published by Wolters Kluwer Health in Circulation
- Vol. 117 (12) , 1555-1562
Magnetic Resonance Imaging Overestimates Ferumoxide-Labeled Stem Cell Survival After Transplantation in the Heart
Background— Stem cell labeling with iron oxide (ferumoxide) particles allows labeled cells to be detected by magnetic resonance imaging (MRI) and is commonly used to track stem cell engraftment. However, the validity of MRI for distinguishing surviving ferumoxide-labeled cells from other sources of MRI signal, for example, macrophages containing ferumoxides released from nonsurviving cells, has not been thoroughly investigated. We sought to determine the relationship between the persistence of iron-dependent MRI signals and cell survival 3 weeks after injection of syngeneic or xenogeneic ferumoxides-labeled stem cells (cardiac-derived stem cells) in rats. Methods and Results— We studied nonimmunoprivileged human and rat cardiac-derived stem cells and human mesenchymal stem cells doubly labeled with ferumoxides and β-galactosidase and injected intramyocardially into immunocompetent Wistar-Kyoto rats. Animals were imaged at 2 days and 3 weeks after stem cell injection in a clinical 3-T MRI scanner. At 2 days, injection sites of xenogeneic and syngeneic cells (cardiac-derived stem cells and mesenchymal stem cells) were identified by MRI as large intramyocardial signal voids that persisted at 3 weeks (50% to 90% of initial signal). Histology (at 3 weeks) revealed the presence of iron-containing macrophages at the injection site, identified by CD68 staining, but very few or no β-galactosidase–positive stem cells in the animals transplanted with syngeneic or xenogeneic cells, respectively. Conclusions— The persistence of significant iron-dependent MRI signal derived from ferumoxide-containing macrophages despite few or no viable stem cells 3 weeks after transplantation indicates that MRI of ferumoxide-labeled cells does not reliably report long-term stem cell engraftment in the heart.
- 25 March 2008
- Published by Wolters Kluwer Health in Circulation
- Vol. 117 (12) , 1555-1562
Magnetic Resonance Imaging Overestimates Ferumoxide-Labeled Stem Cell Survival After Transplantation in the Heart
Background— Stem cell labeling with iron oxide (ferumoxide) particles allows labeled cells to be detected by magnetic resonance imaging (MRI) and is commonly used to track stem cell engraftment. However, the validity of MRI for distinguishing surviving ferumoxide-labeled cells from other sources of MRI signal, for example, macrophages containing ferumoxides released from nonsurviving cells, has not been thoroughly investigated. We sought to determine the relationship between the persistence of iron-dependent MRI signals and cell survival 3 weeks after injection of syngeneic or xenogeneic ferumoxides-labeled stem cells (cardiac-derived stem cells) in rats. Methods and Results— We studied nonimmunoprivileged human and rat cardiac-derived stem cells and human mesenchymal stem cells doubly labeled with ferumoxides and β-galactosidase and injected intramyocardially into immunocompetent Wistar-Kyoto rats. Animals were imaged at 2 days and 3 weeks after stem cell injection in a clinical 3-T MRI scanner. At 2 days, injection sites of xenogeneic and syngeneic cells (cardiac-derived stem cells and mesenchymal stem cells) were identified by MRI as large intramyocardial signal voids that persisted at 3 weeks (50% to 90% of initial signal). Histology (at 3 weeks) revealed the presence of iron-containing macrophages at the injection site, identified by CD68 staining, but very few or no β-galactosidase–positive stem cells in the animals transplanted with syngeneic or xenogeneic cells, respectively. Conclusions— The persistence of significant iron-dependent MRI signal derived from ferumoxide-containing macrophages despite few or no viable stem cells 3 weeks after transplantation indicates that MRI of ferumoxide-labeled cells does not reliably report long-term stem cell engraftment in the heart.
- Open Access
- 1 January 2008
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 10 (1) , 33
Strain-encoding cardiovascular magnetic resonance for assessment of right-ventricular regional function
- 1 January 2008
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 10 (1) , 33
Open AccessStrain-encoding cardiovascular magnetic resonance for assessment of right-ventricular regional function