Akshay Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Akshay Kumar has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Gauri Shankar
Department of Electrical Engineering Indian Institute of Technology (Indian School of Mines) Dhanbad Jharkhand India
3 shared publications - Ankit Kumar Srivastava
Department of Electrical Engineering, Institute of Engineering and Technology, Dr. Rammanohar Lohia Avadh University, Ayodhya, Faizabad 224001, India
1 shared publication - Baseem Khan
Department of Electrical and Computer Engineering, Hawassa University, Hawassa, Ethiopia
1 shared publication Gauri Shankar
Electrical Engineering Department, Indian Institute of Technology (ISM), Dhanbad, Jharkhand
1 shared publication- Gauri Shankar
Department of Electrical Engineering, Indian Institute of Technology (ISM), Dhanbad 826004, Jharkhand, India
1 shared publication Neetu Kumari
Department of Electrical Engineering, Indian Institute of Technology (Indian School of Mines) Dhanbad, Dhanbad, Jharkhand, India
1 shared publication
Latest Publications
- Open Access
- 13 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 109311-109325
Load Frequency Control of Distributed Generators Assisted Hybrid Power System Using QOHSA Tuned Model Predictive Control
One of the challenging issues in a hybrid power system (HPS) is to provide a stable power supply with minimum frequency deviation, which can be accomplished by ensuring a coordinated operation among intermittent type distributed generators (DGs). In this study, the coordinated operation of a tidal turbine generator (TTG) (an emerging and less explored DG), diesel engine generator (DEG) and plug-in hybrid electric vehicles (PHEVs) based an autonomous HPS (a less explored HPS of this kind) for load frequency control (LFC) is investigated. The coordinated operation of different control loops such as the blade pitch control loop of TTG, supplementary control loop of DEG, and power control loop of PHEVs are realized through the maiden application of the proposed quasi-oppositional harmony search algorithm (QOHSA) based model predictive control (MPC) strategy. To establish the superiority of the proposed QOHSA tuned MPC method in mitigating frequency deviation following disturbance, its performance is compared with that of the coordinated performance obtained using QOHSA tuned conventional controllers and other existing optimization algorithms. The results conclude that the suggested method can significantly reduce frequency fluctuation under different load disturbances. The proposed method can handle different variances of the disturbance signals or noise entering the system as well as the model mismatch.
- 13 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 109311-109325
Open AccessLoad Frequency Control of Distributed Generators Assisted Hybrid Power System Using QOHSA Tuned Model Predictive Control
One of the challenging issues in a hybrid power system (HPS) is to provide a stable power supply with minimum frequency deviation, which can be accomplished by ensuring a coordinated operation among intermittent type distributed generators (DGs). In this study, the coordinated operation of a tidal turbine generator (TTG) (an emerging and less explored DG), diesel engine generator (DEG) and plug-in hybrid electric vehicles (PHEVs) based an autonomous HPS (a less explored HPS of this kind) for load frequency control (LFC) is investigated. The coordinated operation of different control loops such as the blade pitch control loop of TTG, supplementary control loop of DEG, and power control loop of PHEVs are realized through the maiden application of the proposed quasi-oppositional harmony search algorithm (QOHSA) based model predictive control (MPC) strategy. To establish the superiority of the proposed QOHSA tuned MPC method in mitigating frequency deviation following disturbance, its performance is compared with that of the coordinated performance obtained using QOHSA tuned conventional controllers and other existing optimization algorithms. The results conclude that the suggested method can significantly reduce frequency fluctuation under different load disturbances. The proposed method can handle different variances of the disturbance signals or noise entering the system as well as the model mismatch.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 387-391
Performance Analysis of Tidal Power Generation System on Load Frequency Control
The integration of tidal power generation system (TPGS) into power system are increasing continuously because of its predictable nature, unlimited supply and environmentally friendly nature. Despite its benefits, TPGS operates at maximum power point and does not support in primary frequency regulation (PFR). As a result, frequency may go beyond acceptable range under severe power system disturbance events and it may lead to load shedding and blackout. To keep the frequency deviation in acceptable range, obtainability of standby capacity is vital condition of TPGS. Therefore, this paper closely analyzes PFR using power reserve margin of deloaded TPGS and droop control to optimize the power output. Dynamic simulations under different penetration levels of TPGS and different values of droop control are carried out to investigate performance of frequency regulation of an isolated multi-source power plants with TPGS. From the MATLAB simulation results analysis, it may be established that TPGS maintain stable operation under different operating conditions and also reduces the burden on conventional power sources.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 387-391
Performance Analysis of Tidal Power Generation System on Load Frequency Control
The integration of tidal power generation system (TPGS) into power system are increasing continuously because of its predictable nature, unlimited supply and environmentally friendly nature. Despite its benefits, TPGS operates at maximum power point and does not support in primary frequency regulation (PFR). As a result, frequency may go beyond acceptable range under severe power system disturbance events and it may lead to load shedding and blackout. To keep the frequency deviation in acceptable range, obtainability of standby capacity is vital condition of TPGS. Therefore, this paper closely analyzes PFR using power reserve margin of deloaded TPGS and droop control to optimize the power output. Dynamic simulations under different penetration levels of TPGS and different values of droop control are carried out to investigate performance of frequency regulation of an isolated multi-source power plants with TPGS. From the MATLAB simulation results analysis, it may be established that TPGS maintain stable operation under different operating conditions and also reduces the burden on conventional power sources.
- Open Access
- 27 September 2018
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 12 (16) , 1864-1875
Optimal load frequency control in deloaded tidal power generation plant‐based interconnected hybrid power system
In recent years, power utilities have witnessed increase in penetration of tidal power generation plant (TPGP) into the power system network and, hence, it may collaborate with conventional units in frequency regulation process to ensure power system stability. Therefore, this study presents a method to monitor the participation of TPGP in load frequency control mechanisms in the presence of conventional unit such as diesel power generation plant. The participation of TPGP is showcased based on primary frequency control topologies such as by producing additional inertia, additional damping along with the concept of deloading operation. These approaches are realised by employing conventional controllers to obtain required power (corresponding to different loading conditions) from TPGP by manipulating the kinetic energy of the rotating mass of tidal turbine blades. For better performance and improved stability of the system, the controller parameters are optimised using quasi‐oppositional harmony search algorithm (QOHSA). The effectiveness of QOHSA is proved by comparing the results obtained by it to those yielded by employing other existing state‐of‐the‐art optimisation methods. The prospective analysis is validated in single‐area and two‐area hybrid power system models through MATLAB simulation studies.
- 27 September 2018
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 12 (16) , 1864-1875
Open AccessOptimal load frequency control in deloaded tidal power generation plant‐based interconnected hybrid power system
In recent years, power utilities have witnessed increase in penetration of tidal power generation plant (TPGP) into the power system network and, hence, it may collaborate with conventional units in frequency regulation process to ensure power system stability. Therefore, this study presents a method to monitor the participation of TPGP in load frequency control mechanisms in the presence of conventional unit such as diesel power generation plant. The participation of TPGP is showcased based on primary frequency control topologies such as by producing additional inertia, additional damping along with the concept of deloading operation. These approaches are realised by employing conventional controllers to obtain required power (corresponding to different loading conditions) from TPGP by manipulating the kinetic energy of the rotating mass of tidal turbine blades. For better performance and improved stability of the system, the controller parameters are optimised using quasi‐oppositional harmony search algorithm (QOHSA). The effectiveness of QOHSA is proved by comparing the results obtained by it to those yielded by employing other existing state‐of‐the‐art optimisation methods. The prospective analysis is validated in single‐area and two‐area hybrid power system models through MATLAB simulation studies.
- Open Access
- 23 March 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (10) , 2288-2298
Dynamic stability enhancement of TCSC‐based tidal power generation using quasi‐oppositional harmony search algorithm
This study presents the dynamic and steady state stability improvement of a tidal power generation system (TPGS) assisted power system model (i.e. single machine infinite bus (SMIB) system) using a thyristor controlled series capacitor (TCSC). To achieve this objective, the TCSC used in the studied model is optimally designed using quasi‐oppositional harmony search algorithm (QOHSA). The complete dynamic equation of the studied power system is realised based on d–q ‐axis decomposition. Eigenvalue analysis is performed using the frequency‐domain approach to study the steady‐state stability while the time‐domain‐based simulation is carried out to determine the dynamic stability of the studied system. To corroborate the effectiveness of QOHSA, results yielded by this algorithm are compared with those obtained using particle swarm optimisation technique. It may be inferred from the results obtained in this study that the QOHSA tuned TCSC outperforms the other in improving the overall stability of the TPGS‐based SMIB system following disturbance. Furthermore, a similar analysis is extended to the TPGS‐based multi‐machine power system model to validate the efficiency of QOHSA in optimal designing of TCSC for dynamic stability improvement.
- 23 March 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (10) , 2288-2298
Open AccessDynamic stability enhancement of TCSC‐based tidal power generation using quasi‐oppositional harmony search algorithm
This study presents the dynamic and steady state stability improvement of a tidal power generation system (TPGS) assisted power system model (i.e. single machine infinite bus (SMIB) system) using a thyristor controlled series capacitor (TCSC). To achieve this objective, the TCSC used in the studied model is optimally designed using quasi‐oppositional harmony search algorithm (QOHSA). The complete dynamic equation of the studied power system is realised based on d–q ‐axis decomposition. Eigenvalue analysis is performed using the frequency‐domain approach to study the steady‐state stability while the time‐domain‐based simulation is carried out to determine the dynamic stability of the studied system. To corroborate the effectiveness of QOHSA, results yielded by this algorithm are compared with those obtained using particle swarm optimisation technique. It may be inferred from the results obtained in this study that the QOHSA tuned TCSC outperforms the other in improving the overall stability of the TPGS‐based SMIB system following disturbance. Furthermore, a similar analysis is extended to the TPGS‐based multi‐machine power system model to validate the efficiency of QOHSA in optimal designing of TCSC for dynamic stability improvement.
- Open Access
- 29 January 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (5) , 1099-1108
Quasi‐oppositional harmony search algorithm based optimal dynamic load frequency control of a hybrid tidal–diesel power generation system
In recent years, high penetration of distributed generations based on wind energy, solar energy and so on in the existing power system network has been noticed. However, due to their stochastic behaviour, operations under autonomous mode as well as in grid‐connected mode are not an easy task. This has forced the power utilities to re‐define frequency regulation criteria to enhance the overall system stability and reliability. In line with the same, dynamic performance analysis of load frequency control (LFC) of an autonomous hybrid power system model (HPSM) consisting of tidal power plant (TPP) and diesel power plant is explored in this study. A concept of deloaded TPP is adopted in the studied HPSM to utilise the available reserve power for the frequency support. Apart from this, the studied model also incorporates frequency regulation through inertia and damping control and supplementary control strategies. These control strategies are realised through conventional controllers whose gain values are optimised using quasi‐oppositional harmony search algorithm (QOHSA) for the optimal dynamic performance of LFC. The efficacy of the proposed QOHSA is corroborated by comparing the results with those yielded by few other existing state‐of‐the‐art algorithms.
- 29 January 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (5) , 1099-1108
Open AccessQuasi‐oppositional harmony search algorithm based optimal dynamic load frequency control of a hybrid tidal–diesel power generation system
In recent years, high penetration of distributed generations based on wind energy, solar energy and so on in the existing power system network has been noticed. However, due to their stochastic behaviour, operations under autonomous mode as well as in grid‐connected mode are not an easy task. This has forced the power utilities to re‐define frequency regulation criteria to enhance the overall system stability and reliability. In line with the same, dynamic performance analysis of load frequency control (LFC) of an autonomous hybrid power system model (HPSM) consisting of tidal power plant (TPP) and diesel power plant is explored in this study. A concept of deloaded TPP is adopted in the studied HPSM to utilise the available reserve power for the frequency support. Apart from this, the studied model also incorporates frequency regulation through inertia and damping control and supplementary control strategies. These control strategies are realised through conventional controllers whose gain values are optimised using quasi‐oppositional harmony search algorithm (QOHSA) for the optimal dynamic performance of LFC. The efficacy of the proposed QOHSA is corroborated by comparing the results with those yielded by few other existing state‐of‐the‐art algorithms.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 517-521
Dynamic stability performance improvement of SMIB power system using TCSC and SVC
Voltage, frequency and power (real and reactive) plays an important role in power system. It should be in a predefined limit and if any one of them violates its limits then the system becomes unstable. Our generation capacity is not increasing as compare to loads increasing due to environmental and economical reason. Power system is operating at critical value. To enhance the maximum power transfer capability and improve dynamic stability of the system we use Flexible AC transmission systems (FACTS) devices. FACTS devices have very fast response. It can be operate either in normal or abnormal conditions. In this paper, mainly two types of FACTS controllers we have analyzed i.e. Thyristor controlled series compensator (TCSC) and Static VAR Compensator (SVC). TCSC mainly vary the reactance of the transmission line and improves stability limit. TCSC is also known as series compensator. However SVC improves the voltage regulation where it has been connected. SVC is also known as shunt compensator. These controllers have very fast response. This paper shows how we can improve the dynamic stability by using TCSC and SVC which are connected to single machine infinite bus (SMIB) power system.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 517-521
Dynamic stability performance improvement of SMIB power system using TCSC and SVC
Voltage, frequency and power (real and reactive) plays an important role in power system. It should be in a predefined limit and if any one of them violates its limits then the system becomes unstable. Our generation capacity is not increasing as compare to loads increasing due to environmental and economical reason. Power system is operating at critical value. To enhance the maximum power transfer capability and improve dynamic stability of the system we use Flexible AC transmission systems (FACTS) devices. FACTS devices have very fast response. It can be operate either in normal or abnormal conditions. In this paper, mainly two types of FACTS controllers we have analyzed i.e. Thyristor controlled series compensator (TCSC) and Static VAR Compensator (SVC). TCSC mainly vary the reactance of the transmission line and improves stability limit. TCSC is also known as series compensator. However SVC improves the voltage regulation where it has been connected. SVC is also known as shunt compensator. These controllers have very fast response. This paper shows how we can improve the dynamic stability by using TCSC and SVC which are connected to single machine infinite bus (SMIB) power system.