Soohoon Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Soohoon Choi has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Sung Kyu Maeng
Department of Civil and Environmental Engineering, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul, 05006, Republic of Korea
4 shared publications - Chin Pao Huang
Department of Civil and Environmental Engineering, University of Delaware, Newark, DE 19711, USA
2 shared publications Jihee Moon
2 shared publicationsJuhee Yang
Korea Institute of Construction & Transportation Technology Evaluation and Planning , 1600 Gwanyang-dong, Dongan-gu, Anyang-si, Gyeonggi-do , 431-060 , Republic of Korea
2 shared publicationsSangyoup Lee
2 shared publications- Byeong Gyu Choi
School of Civil, Environmental & Architectural Engineering, Korea University, 145, Anam-ro, Sungbuk-ku, Seoul 136-701, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 1 August 2026
- Published by Korean Society of Environmental Engineering in Journal of Korean Society of Environmental Engineers
- Vol. 48 (8) , 205-215
Nano- and Microplastic Release from Indoor Drinking Water Pipes: characteristics of different Pipe Materials
The current study comparatively evaluated the release characteristics of nano/microplastics and organic matter from non-metallic drinking water pipes. Accelerated aging experiments were conducted on polybutylene(PB) and impact-modified polyvinyl chloride(iPVC) to verify the effects of long-term operations on the pipe material. FT-IR spectra of particles detected after the aging conditions matched those of the original pipe materials, confirming the presence of pipe-derived particles. Subsequently, a continuous-flow system simulating drinking water distribution conditions was established, and a pipe circulation experiment was conducted for approximately 45 days under a residual chlorine concentration of about 4.3mg/L and a temperature of 40°C. The results showed that PB exhibited a higher cumulative release of nanoparticles and a greater number of microplastic particles than iPVC. Results also showed that the total organic carbon(TOC) release from was also higher in PB. In contrast, iPVC and stainless steel(STS) showed no substantial differences in TOC concentration or cumulative nanoparticle release. These findings demonstrate that the release characteristics of nano/microplastics and organic matter vary depending on pipe material under drinking water distribution conditions and suggest that the potential release of nano/microplastics should be considered when selecting materials for drinking water pipes.
- 1 August 2026
- Published by Korean Society of Environmental Engineering in Journal of Korean Society of Environmental Engineers
- Vol. 48 (8) , 205-215
Open AccessNano- and Microplastic Release from Indoor Drinking Water Pipes: characteristics of different Pipe Materials
The current study comparatively evaluated the release characteristics of nano/microplastics and organic matter from non-metallic drinking water pipes. Accelerated aging experiments were conducted on polybutylene(PB) and impact-modified polyvinyl chloride(iPVC) to verify the effects of long-term operations on the pipe material. FT-IR spectra of particles detected after the aging conditions matched those of the original pipe materials, confirming the presence of pipe-derived particles. Subsequently, a continuous-flow system simulating drinking water distribution conditions was established, and a pipe circulation experiment was conducted for approximately 45 days under a residual chlorine concentration of about 4.3mg/L and a temperature of 40°C. The results showed that PB exhibited a higher cumulative release of nanoparticles and a greater number of microplastic particles than iPVC. Results also showed that the total organic carbon(TOC) release from was also higher in PB. In contrast, iPVC and stainless steel(STS) showed no substantial differences in TOC concentration or cumulative nanoparticle release. These findings demonstrate that the release characteristics of nano/microplastics and organic matter vary depending on pipe material under drinking water distribution conditions and suggest that the potential release of nano/microplastics should be considered when selecting materials for drinking water pipes.
- 1 June 2019
- Published by Elsevier in Water Research
- Vol. 156, 58-70
Reducing bacterial aerosol emissions from membrane bioreactors: The impact of SRT and the addition of PAC and calcium
- 1 June 2019
- Published by Elsevier in Water Research
- Vol. 156, 58-70
Reducing bacterial aerosol emissions from membrane bioreactors: The impact of SRT and the addition of PAC and calcium
- 1 January 2019
- Published by Elsevier in Desalination and Water Treatment
- Vol. 140, 42-49
Evaluation of eluted organic matter characteristics and biofilm formation potential from polymeric material in contact with treated water
- 1 January 2019
- Published by Elsevier in Desalination and Water Treatment
- Vol. 140, 42-49
Evaluation of eluted organic matter characteristics and biofilm formation potential from polymeric material in contact with treated water
- 1 October 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 639, 331-338
Multi-barrier approach for removing organic micropollutants using mobile water treatment systems
- 1 October 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 639, 331-338
Multi-barrier approach for removing organic micropollutants using mobile water treatment systems
- 1 June 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 625, 1321-1329
A seasonal observation on the distribution of engineered nanoparticles in municipal wastewater treatment systems exemplified by TiO2 and ZnO
- 1 June 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 625, 1321-1329
A seasonal observation on the distribution of engineered nanoparticles in municipal wastewater treatment systems exemplified by TiO2 and ZnO
- 1 July 2017
- Published by Elsevier in Science of The Total Environment
- Vol. 590-591, 809-817
Looking for engineered nanoparticles (ENPs) in wastewater treatment systems: Qualification and quantification aspects
- 1 July 2017
- Published by Elsevier in Science of The Total Environment
- Vol. 590-591, 809-817
Looking for engineered nanoparticles (ENPs) in wastewater treatment systems: Qualification and quantification aspects
- Open Access
- 7 March 2013
- Published by Elsevier in Desalination and Water Treatment
- Vol. 51 (22-24) , 4283-4290
Fluorescent nano particle application for a membrane surface integrity test: Sensitivity, stability, and reliability of the particles
In this research, silica-based fluorescent particles were synthesized and used as a surrogate detector to evaluate the integrity of a compromised flat sheet membrane. Three different sizes of particles were synthesized and dyed with a fluorescent dye to make a fluorescence image under a UV light. Experiments were designed to test the sensitivity of the detection limit, stability of particles, and reliability of the proposed method. UV spectrometer and image analysis were used to evaluate the detection limits and measure the concentration and mass of the particles in the feed and permeate. For the stability of the particles, dye-leakage tests were conducted to estimate the amount of fluorescent decay when fluorescent particles were dissolved in an aqueous solvent. The effect of the particles on the membrane fouling was also investigated by conducting a batch filtration test of undamaged membranes. To examine the reliability of the proposed method, a series of filtration tests were performed with the damaged membranes by applying the fluorescent particles as a surrogate. As a result, the image analysis could detect the maximum mass of particles of 5 mg. The particles showed the stable fluorescence intensity within 24 h after being dissolved into 100% ethanol solution. In considering the pore size in the membrane, the particles with a size of about three times larger than the membrane pores were the most compatible surrogate for the integrity test to prevent the undesirable affect of having the membrane fouling. Finally, the size of breach on the membrane surface could be predicted, possibly from the image analysis of the permeate containing the fluorescent particles outflow from a damaged part of the membrane surface.
- 7 March 2013
- Published by Elsevier in Desalination and Water Treatment
- Vol. 51 (22-24) , 4283-4290
Open AccessFluorescent nano particle application for a membrane surface integrity test: Sensitivity, stability, and reliability of the particles
In this research, silica-based fluorescent particles were synthesized and used as a surrogate detector to evaluate the integrity of a compromised flat sheet membrane. Three different sizes of particles were synthesized and dyed with a fluorescent dye to make a fluorescence image under a UV light. Experiments were designed to test the sensitivity of the detection limit, stability of particles, and reliability of the proposed method. UV spectrometer and image analysis were used to evaluate the detection limits and measure the concentration and mass of the particles in the feed and permeate. For the stability of the particles, dye-leakage tests were conducted to estimate the amount of fluorescent decay when fluorescent particles were dissolved in an aqueous solvent. The effect of the particles on the membrane fouling was also investigated by conducting a batch filtration test of undamaged membranes. To examine the reliability of the proposed method, a series of filtration tests were performed with the damaged membranes by applying the fluorescent particles as a surrogate. As a result, the image analysis could detect the maximum mass of particles of 5 mg. The particles showed the stable fluorescence intensity within 24 h after being dissolved into 100% ethanol solution. In considering the pore size in the membrane, the particles with a size of about three times larger than the membrane pores were the most compatible surrogate for the integrity test to prevent the undesirable affect of having the membrane fouling. Finally, the size of breach on the membrane surface could be predicted, possibly from the image analysis of the permeate containing the fluorescent particles outflow from a damaged part of the membrane surface.
- 1 February 2011
- Published by Elsevier in Journal of Membrane Science
- Vol. 367 (1-2) , 306-313
Use of fluorescent silica particles for checking the integrity of microfiltration membranes
- 1 February 2011
- Published by Elsevier in Journal of Membrane Science
- Vol. 367 (1-2) , 306-313
Use of fluorescent silica particles for checking the integrity of microfiltration membranes
- 1 December 2010
- Published by Elsevier in Desalination
- Vol. 264 (3) , 236-242
Evaluation of biofouling potential of microorganism using flow field-flow fractionation (Fl-FFF)
- 1 December 2010
- Published by Elsevier in Desalination
- Vol. 264 (3) , 236-242
Evaluation of biofouling potential of microorganism using flow field-flow fractionation (Fl-FFF)
- 1 October 2009
- Published by Elsevier in Desalination
- Vol. 247 (1-3) , 247-259
Assessment of various membrane fouling indexes under seawater conditions
- 1 October 2009
- Published by Elsevier in Desalination
- Vol. 247 (1-3) , 247-259
Assessment of various membrane fouling indexes under seawater conditions