Ken Suzuki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ken Suzuki has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Johannes Zmeskal
Stefan Meyer Institute for Subatomic Physics, Vienna, Austria
74 shared publications - Eberhard Widmann
Austrian Academy of Sciences
62 shared publications J. Marton
Stefan Meyer Institute for Subatomic Physics, Vienna, Austria
61 shared publications- Ryugo S. Hayano
Department of Physics, School of Science, The University of Tokyo, Tokyo, Japan
43 shared publications - Hiroyuki Fujioka
Institute of Science Tokyo 152-8551 Tokyo Japan
38 shared publications L. Gruber
33 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2026 (10)
Feasibility Demonstration of a High-Momentum, High-Purity Muon Beamline at the J-PARC Hadron Experimental Facility
We have established and characterized a novel high-purity muon beam delivery scheme, designated as the $\mu 20$ mode, at the high-momentum hadron beamline (B-line) of the J-PARC Hadron Experimental Facility. This scheme delivers tertiary muons produced via the in-flight backward decays of secondary pions in the straight section of the beamline, inherently suppressing parent hadron contamination. In a systematic performance evaluation, the muon beam achieved a standalone intensity of $1.7 \times 10^3~{\rm particles/spill}$ with a spatial spread (standard deviation, $\sigma$) of approximately $15~{\rm mm}$ at the downstream detector position. A systematic attenuation analysis utilizing an iron absorber verified a high muon purity of $98.0 \pm 0.6\%$ for the $3~{\rm GeV}/c$ muon beam mode. Crucially, this work marks the first successful feasibility study of a pure multi-${\rm GeV}/c$ muon beamline operation at an experimental facility in Japan.- 1 October 2026
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2026 (10)
Open AccessFeasibility Demonstration of a High-Momentum, High-Purity Muon Beamline at the J-PARC Hadron Experimental Facility
We have established and characterized a novel high-purity muon beam delivery scheme, designated as the $\mu 20$ mode, at the high-momentum hadron beamline (B-line) of the J-PARC Hadron Experimental Facility. This scheme delivers tertiary muons produced via the in-flight backward decays of secondary pions in the straight section of the beamline, inherently suppressing parent hadron contamination. In a systematic performance evaluation, the muon beam achieved a standalone intensity of $1.7 \times 10^3~{\rm particles/spill}$ with a spatial spread (standard deviation, $\sigma$) of approximately $15~{\rm mm}$ at the downstream detector position. A systematic attenuation analysis utilizing an iron absorber verified a high muon purity of $98.0 \pm 0.6\%$ for the $3~{\rm GeV}/c$ muon beam mode. Crucially, this work marks the first successful feasibility study of a pure multi-${\rm GeV}/c$ muon beamline operation at an experimental facility in Japan. - Open Access
- 22 May 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
Observation of tensor-driven high-momentum neutrons in 16O via (p, d) reactions and zero-degree deuteron momentum spectroscopy
- 22 May 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
Open AccessObservation of tensor-driven high-momentum neutrons in 16O via (p, d) reactions and zero-degree deuteron momentum spectroscopy
- 7 April 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (14) , 142501
Excitation Spectra of the C 12 ( p , d ) Reaction near the η ′ -Meson Emission Threshold Measured in Coincidence with High-Momentum Protons
The missing mass of the ^{12}C(p,d) reaction has been measured near the η^{'}-meson emission threshold in coincidence with a high-momentum proton to selectively collect η^{'}-^{11}C mesic nucleus formation events at GSI, Germany. A 2.5 GeV proton excites a carbon nucleus in order to form an η^{'}-mesic nucleus emitting a deuteron forward with an energy of ∼1.5 GeV. The deuteron is momentum analyzed by the fragment separator used as a high-resolution spectrometer to deduce the excitation energy of the residual system. The large-acceptance detector WASA surrounding the target identifies high-momentum protons emitted in the decay of the η^{'}-mesic nucleus. The measured semiexclusive spectrum exhibits structures below the threshold though the statistical significance is limited. The spectrum is fitted by theoretically calculated spectra varying optical-potential parameters of the η^{'}-nucleus interaction. The analysis results indicate possible formation of η^{'}-mesic nuclei for the real potential depth of ∼-61 MeV with a local statistical significance of 3.5σ and, taking into account the look-elsewhere effect, a global significance of 2.1σ.
- 7 April 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (14) , 142501
Excitation Spectra of the C 12 ( p , d ) Reaction near the η ′ -Meson Emission Threshold Measured in Coincidence with High-Momentum Protons
The missing mass of the ^{12}C(p,d) reaction has been measured near the η^{'}-meson emission threshold in coincidence with a high-momentum proton to selectively collect η^{'}-^{11}C mesic nucleus formation events at GSI, Germany. A 2.5 GeV proton excites a carbon nucleus in order to form an η^{'}-mesic nucleus emitting a deuteron forward with an energy of ∼1.5 GeV. The deuteron is momentum analyzed by the fragment separator used as a high-resolution spectrometer to deduce the excitation energy of the residual system. The large-acceptance detector WASA surrounding the target identifies high-momentum protons emitted in the decay of the η^{'}-mesic nucleus. The measured semiexclusive spectrum exhibits structures below the threshold though the statistical significance is limited. The spectrum is fitted by theoretically calculated spectra varying optical-potential parameters of the η^{'}-nucleus interaction. The analysis results indicate possible formation of η^{'}-mesic nuclei for the real potential depth of ∼-61 MeV with a local statistical significance of 3.5σ and, taking into account the look-elsewhere effect, a global significance of 2.1σ.
- 8 October 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1083
Performance of newly constructed plastic scintillator barrel in the WASA-FRS experiments and evaluation of radiation damage effects on multi-pixel photon counter
- 8 October 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1083
Performance of newly constructed plastic scintillator barrel in the WASA-FRS experiments and evaluation of radiation damage effects on multi-pixel photon counter
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , C06070
Development of a cost-effective RICH detector for MARQ spectrometer using SiPM technology
We are developing a Ring Imaging Cherenkov (RICH) detector as a part of MARQ spectrometer under construction at the π20 beam line of the J-PARC Hadron Experimental Facility. The RICH will provide particle identification for scattered particles off target, including π ±, K ±, p, p̅ over a broad momentum range of 2–16 GeV/c. To accommodate this range, the detector employs a dual-radiator system using aerogel and gas. Cherenkov photons are detected by Silicon Photomultiplier (SiPMs). We address three key technical challenges, (1) the mismatch between the photosensor's sensitive area and the required detection plane size, (2) high dark count rate of SiPM, and (3) the search for a viable gas radiator alternative to the commonly used but now-banned perfluorobutane, C4F10. Our solutions to these challenges are discussed.
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , C06070
Development of a cost-effective RICH detector for MARQ spectrometer using SiPM technology
We are developing a Ring Imaging Cherenkov (RICH) detector as a part of MARQ spectrometer under construction at the π20 beam line of the J-PARC Hadron Experimental Facility. The RICH will provide particle identification for scattered particles off target, including π ±, K ±, p, p̅ over a broad momentum range of 2–16 GeV/c. To accommodate this range, the detector employs a dual-radiator system using aerogel and gas. Cherenkov photons are detected by Silicon Photomultiplier (SiPMs). We address three key technical challenges, (1) the mismatch between the photosensor's sensitive area and the required detection plane size, (2) high dark count rate of SiPM, and (3) the search for a viable gas radiator alternative to the commonly used but now-banned perfluorobutane, C4F10. Our solutions to these challenges are discussed.
- Open Access
- 7 November 2019
- Published by Physical Society of Japan
Λ(1405) Spectroscopy via the In-flight d(K−, n) Reaction at the J-PARC K1.8BR
- 7 November 2019
- Published by Physical Society of Japan
Open AccessΛ(1405) Spectroscopy via the In-flight d(K−, n) Reaction at the J-PARC K1.8BR
- 1 December 2017
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 876, 93-95
Extension of the MCP-PMT lifetime
- 1 December 2017
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 876, 93-95
Extension of the MCP-PMT lifetime
- Open Access
- 1 October 2017
- Published by Elsevier in Physics Letters B
- Vol. 773, 68-80
Linear and non-linear flow mode in Pb–Pb collisions at- 1 October 2017
- Published by Elsevier in Physics Letters B
- Vol. 773, 68-80
Open AccessLinear and non-linear flow mode in Pb–Pb collisions at