Konrad S. Stadler
Research Subjects
Konrad S. Stadler has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
D. Leibundgut
4 shared publications- Leonard O’ Sullivan
School of Architecture and Product Design Health Research Institute Limerick Digital Cancer Research Centre University of Limerick Limerick Ireland ul.ie
4 shared publications Eduardo Gallestey
ABB Switzerland Ltd, Switzerland
3 shared publicationsEmilio Schmidhauser
School of Engineering,Zurich University of Applied Sciences,Winterthur,Switzerland
3 shared publications- Thomas Bouillon
Senior Expert, Modeling and Simulation, Novartis Pharma, Basel, Switzerland
3 shared publications A. M. Zbinden
2 shared publications
Latest Publications
- 16 June 2022
- Published by Springer Nature in Wissensmanagement
- Vol. 4 (3) , 46-47
Der Wandel als (Lebens-) Chance
- 16 June 2022
- Published by Springer Nature in Wissensmanagement
- Vol. 4 (3) , 46-47
Der Wandel als (Lebens-) Chance
- Open Access
- 26 February 2019
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 37 (12) , 2014-2034
Design and Evaluation of a Soft Assistive Lower Limb Exoskeleton
Summary: Wearable devices are fast evolving to address mobility and autonomy needs of elderly people who would benefit from physical assistance. Recent developments in soft robotics provide important opportunities to develop soft exoskeletons (also called exosuits) to enable both physical assistance and improved usability and acceptance for users. The XoSoft EU project has developed a modular soft lower limb exoskeleton to assist people with low mobility impairments. In this paper, we present the design of a soft modular lower limb exoskeleton to improve person’s mobility, contributing to independence and enhancing quality of life. The novelty of this work is the integration of quasi-passive elements in a soft exoskeleton. The exoskeleton provides mechanical assistance for subjects with low mobility impairments reducing energy requirements between 10% and 20%. Investigation of different control strategies based on gait segmentation and actuation elements is presented. A first hip–knee unilateral prototype is described, developed, and its performance assessed on a post-stroke patient for straight walking. The study presents an analysis of the human–exoskeleton energy patterns by way of the task-based biological power generation. The resultant assistance, in terms of power, was 10.9% ± 2.2% for hip actuation and 9.3% ± 3.5% for knee actuation. The control strategy improved the gait and postural patterns by increasing joint angles and foot clearance at specific phases of the walking cycle.
- 26 February 2019
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 37 (12) , 2014-2034
Open AccessDesign and Evaluation of a Soft Assistive Lower Limb Exoskeleton
Summary: Wearable devices are fast evolving to address mobility and autonomy needs of elderly people who would benefit from physical assistance. Recent developments in soft robotics provide important opportunities to develop soft exoskeletons (also called exosuits) to enable both physical assistance and improved usability and acceptance for users. The XoSoft EU project has developed a modular soft lower limb exoskeleton to assist people with low mobility impairments. In this paper, we present the design of a soft modular lower limb exoskeleton to improve person’s mobility, contributing to independence and enhancing quality of life. The novelty of this work is the integration of quasi-passive elements in a soft exoskeleton. The exoskeleton provides mechanical assistance for subjects with low mobility impairments reducing energy requirements between 10% and 20%. Investigation of different control strategies based on gait segmentation and actuation elements is presented. A first hip–knee unilateral prototype is described, developed, and its performance assessed on a post-stroke patient for straight walking. The study presents an analysis of the human–exoskeleton energy patterns by way of the task-based biological power generation. The resultant assistance, in terms of power, was 10.9% ± 2.2% for hip actuation and 9.3% ± 3.5% for knee actuation. The control strategy improved the gait and postural patterns by increasing joint angles and foot clearance at specific phases of the walking cycle.
- 1 December 2017
- Published by Springer Nature in Journal of Bionic Engineering
- Vol. 14 (4) , 706-715
Simulation Architecture for Modelling Interaction Between User and Elbow-articulated Exoskeleton
- 1 December 2017
- Published by Springer Nature in Journal of Bionic Engineering
- Vol. 14 (4) , 706-715
Simulation Architecture for Modelling Interaction Between User and Elbow-articulated Exoskeleton
- 13 October 2016
- Published by Springer Nature
- p. 1085-1089
Reflex Response Modelling of Exoskeleton-User Interaction
- 13 October 2016
- Published by Springer Nature
- p. 1085-1089
Reflex Response Modelling of Exoskeleton-User Interaction
- 5 October 2016
- Published by Springer Nature
- p. 83-88
XoSoft - A Vision for a Soft Modular Lower Limb Exoskeleton
- 5 October 2016
- Published by Springer Nature
- p. 83-88
XoSoft - A Vision for a Soft Modular Lower Limb Exoskeleton
- 3 August 2016
- Published by World Scientific Pub Co Pte Ltd
- p. 806-813
ROBO-MATE AN EXOSKELETON FOR INDUSTRIAL USE — CONCEPT AND MECHANICAL DESIGN
- 3 August 2016
- Published by World Scientific Pub Co Pte Ltd
- p. 806-813
ROBO-MATE AN EXOSKELETON FOR INDUSTRIAL USE — CONCEPT AND MECHANICAL DESIGN
- Open Access
- 29 June 2016
- Published by Association for Computing Machinery (ACM)
- p. 1-2
Interaction modelling for wearable assistive devices
An exoskeleton may help healthy older adults stay independent for a longer time by augmenting their torque at weakened joints. Predictive models are useful to develop exoskeletons and assess the effect of exoskeletons on the user. Existing models that predict the effect of exoskeletons on the user use pre-defined motions which do not change when the forces applied by the exoskeleton changes. In this work we have developed and tested a simulation architecture that incorporates the dynamic interaction between the user and the exoskeleton. This allows to predict modified motions due to the influence of the exoskeleton
- 29 June 2016
- Published by Association for Computing Machinery (ACM)
- p. 1-2
Open AccessInteraction modelling for wearable assistive devices
An exoskeleton may help healthy older adults stay independent for a longer time by augmenting their torque at weakened joints. Predictive models are useful to develop exoskeletons and assess the effect of exoskeletons on the user. Existing models that predict the effect of exoskeletons on the user use pre-defined motions which do not change when the forces applied by the exoskeleton changes. In this work we have developed and tested a simulation architecture that incorporates the dynamic interaction between the user and the exoskeleton. This allows to predict modified motions due to the influence of the exoskeleton
- Top Cited Papers
- 7 October 2015
- Published by Taylor & Francis in Ergonomics
- Vol. 59 (5) , 671-681
Exoskeletons for industrial application and their potential effects on physical work load
The aim of this review was to provide an overview of assistive exoskeletons that have specifically been developed for industrial purposes and to assess the potential effect of these exoskeletons on reduction of physical loading on the body. The search resulted in 40 papers describing 26 different industrial exoskeletons, of which 19 were active (actuated) and 7 were passive (non-actuated). For 13 exoskeletons, the effect on physical loading has been evaluated, mainly in terms of muscle activity. All passive exoskeletons retrieved were aimed to support the low back. Ten-forty per cent reductions in back muscle activity during dynamic lifting and static holding have been reported. Both lower body, trunk and upper body regions could benefit from active exoskeletons. Muscle activity reductions up to 80% have been reported as an effect of active exoskeletons. Exoskeletons have the potential to considerably reduce the underlying factors associated with work-related musculoskeletal injury. Practitioner Summary: Worldwide, a significant interest in industrial exoskeletons does exist, but a lack of specific safety standards and several technical issues hinder mainstay practical use of exoskeletons in industry. Specific issues include discomfort (for passive and active exoskeletons), weight of device, alignment with human anatomy and kinematics, and detection of human intention to enable smooth movement (for active exoskeletons).
- 7 October 2015
- Published by Taylor & Francis in Ergonomics
- Vol. 59 (5) , 671-681
Top Cited PapersExoskeletons for industrial application and their potential effects on physical work load
The aim of this review was to provide an overview of assistive exoskeletons that have specifically been developed for industrial purposes and to assess the potential effect of these exoskeletons on reduction of physical loading on the body. The search resulted in 40 papers describing 26 different industrial exoskeletons, of which 19 were active (actuated) and 7 were passive (non-actuated). For 13 exoskeletons, the effect on physical loading has been evaluated, mainly in terms of muscle activity. All passive exoskeletons retrieved were aimed to support the low back. Ten-forty per cent reductions in back muscle activity during dynamic lifting and static holding have been reported. Both lower body, trunk and upper body regions could benefit from active exoskeletons. Muscle activity reductions up to 80% have been reported as an effect of active exoskeletons. Exoskeletons have the potential to considerably reduce the underlying factors associated with work-related musculoskeletal injury. Practitioner Summary: Worldwide, a significant interest in industrial exoskeletons does exist, but a lack of specific safety standards and several technical issues hinder mainstay practical use of exoskeletons in industry. Specific issues include discomfort (for passive and active exoskeletons), weight of device, alignment with human anatomy and kinematics, and detection of human intention to enable smooth movement (for active exoskeletons).
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10851992,p. 593-598
Stochastic optimal planning of solar thermal power
This paper describes the planning of the operation of a concentrated solar power plant under the assumption that the produced electricity is sold on the spot market. By using nonlinear stochastic optimization, the uncertainty of the irradiation forecast is considered. Real data is used to compare the performance of stochastic optimization of affine policies and of single decision trajectories as well as conventional deterministic optimization. It is shown that the stochastic optimization has the potential to better exploit the system's energy storage and thus achieves higher performance for energy time-shifting.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10851992,p. 593-598
Stochastic optimal planning of solar thermal power
This paper describes the planning of the operation of a concentrated solar power plant under the assumption that the produced electricity is sold on the spot market. By using nonlinear stochastic optimization, the uncertainty of the irradiation forecast is considered. Real data is used to compare the performance of stochastic optimization of affine policies and of single decision trajectories as well as conventional deterministic optimization. It is shown that the stochastic optimization has the potential to better exploit the system's energy storage and thus achieves higher performance for energy time-shifting.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
Magnetic cross-coupling effects on the performance of the synchronous reluctance machine
Performance prediction and control of a synchronous reluctance machine is based on the knowledge of the direct and the quadrature axis inductances. The properties of the machine depend on the saliency ratio of these inductances and this is implemented by introducing internal flux barriers. In an idealized linear magnetic topology the superposition principle would allow to derive both properties separately by exiting a single axis. However, in a real case with saturation effects a cross coupling of the axes appears, which alters the resulting values. Both methods are adopted in the numerical simulation and in practical measurements. By comparing the inductance values, the effects of saturation and coupling can be observed and interpreted. The ideal current trajectories in the operation regions or the resulting curves for a variable speed operation alter when different properties of the machine are assumed. The comparison to practical measurements show a certain match of the simplified methods. However, the cross coupling are more pronounced in regions with low currents and therefore the differences increase in the low flux areas at high speed.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
Magnetic cross-coupling effects on the performance of the synchronous reluctance machine
Performance prediction and control of a synchronous reluctance machine is based on the knowledge of the direct and the quadrature axis inductances. The properties of the machine depend on the saliency ratio of these inductances and this is implemented by introducing internal flux barriers. In an idealized linear magnetic topology the superposition principle would allow to derive both properties separately by exiting a single axis. However, in a real case with saturation effects a cross coupling of the axes appears, which alters the resulting values. Both methods are adopted in the numerical simulation and in practical measurements. By comparing the inductance values, the effects of saturation and coupling can be observed and interpreted. The ideal current trajectories in the operation regions or the resulting curves for a variable speed operation alter when different properties of the machine are assumed. The comparison to practical measurements show a certain match of the simplified methods. However, the cross coupling are more pronounced in regions with low currents and therefore the differences increase in the low flux areas at high speed.