SHSeong-Hyun Han

Seong-Hyun Han

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Seong-Hyun Han has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simultaneous Electrochemical Analysis of Uric Acid and Xanthine in Human Saliva and Serum Samples Using a 3D Reduced Graphene Oxide Nanocomposite-Modified Electrode

    by Seong-Hyun Han, Ki Won Moon, Yun Jong Lee, Gi-Ja Lee

    Accurate and effective diagnosis and individualized management of gout can be potentially achieved by detecting uric acid (UA) and xanthine (XT) simultaneously using an easy-to-use method. Herein, we report simultaneous detection of UA and XT using a 3-dimensional (3D) macroporous gold nanoparticle-incorporated reduced graphene oxide–carbon nanotube nanocomposite (GNP/rGO-CNT). The GNP/rGO-CNT was simply prepared on a glassy carbon electrode (GCE) by one-step electrochemical deposition/co-reduction. It displayed highly sensitive and selective responses to UA and XT, showing excellent stability and good reproducibility in neutral pH. It was demonstrated that 3D GNP/rGO-CNT on GCE could detect UA and XT in human saliva and blood serum simultaneously. This GNP/rGO-CNT for simultaneous detection of UA and XT in human body fluids can be utilized for monitoring drug adherence for gout treatment, together with gout diagnosis.


  • Open Access

    Study on the blood flow in stenosed microvascular model under pulsed magnetic field

    by Jinwon Mok, Seonghyun Han, Hyunsook Lee

    It is widely known that abnormal peripheral blood circulation due to intravascular stenosis causes ischemic diseases and blood circulatory disorders. The purpose of this study was to investigate the influence of pulsed magnetic field (PMF) on hemodynamic characteristics in blood vessel with stenosis of 33% with diameter of 15μm, with the change of PMF intensity and hematocrit (Ht) concentration. Stenosed microvascular channels were fabricated using polydimethylsiloxane (PDMS). Our PMF stimulator has the maximum intensity of 2700G at a transition time of 102 μs with pulse intervals of 1Hz. For the Ht altered RBCs suspension, the changes in blood flow and deformation of red blood cells (RBCs) were examined before and after PMF stimulus with various intensity of 200∼2700G. In stenosed channel, threshold intensity for improvement of blood flow seems to be 400G. The higher the Ht, the higher the viscosity and the slower the velocity of RBCs, but after PMF stimulus, RBCs movement overall increased by more than 9∼67% in both Ht 5% and 20% RBCs suspension. Our study shows that PMF plays an important role in in treating cardiovascular diseases with blood circulation disorders caused by narrowing microvascular due to stenosis. In order to extend our results to clinical applications, we need develop more indicators for hemorheologic characteristics such as viscosity and resistance, and need further experiment with diverse PMF condition such as pulse shape, pulse duration, or repetition rate.