Majid Poshtan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Majid Poshtan has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Javad Poshtan
EE Dept., Iran University of Science and Technology, Tehran, Iran
12 shared publicationsJ. Poshtan
Faculty of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran
4 shared publications- Allahyar Montazeri
School of Engineering, Lancaster University, Lancaster, U.K.
3 shared publications F. Karami
3 shared publicationsHamid Fekri Azgomi
EE Dept., Iran University of Science and Technology, Tehran, Iran
3 shared publications- Abdul Rahiman Beig
Department of Electrical Engineering, Advanced Power and Energy Center (APEC), Khalifa University, Abu Dhabi, United Arab Emirates
2 shared publications
Latest Publications
- 30 May 2024
- Published by American Society for Engineering Education
SOLAR FARM UTILIZING A BATTERY ENERGY STORAGE SYSTEM
- 30 May 2024
- Published by American Society for Engineering Education
SOLAR FARM UTILIZING A BATTERY ENERGY STORAGE SYSTEM
- 13 February 2024
- Published by American Society for Engineering Education
Experiments in Adopting Computer-Aided Learning in Electrical Engineering
- 13 February 2024
- Published by American Society for Engineering Education
Experiments in Adopting Computer-Aided Learning in Electrical Engineering
- 8 February 2024
- Published by American Society for Engineering Education
Combined Student Evaluation and Competition Class Work
- 8 February 2024
- Published by American Society for Engineering Education
Combined Student Evaluation and Competition Class Work
- Open Access
- 11 January 2024
- Published by MDPI AG in Mathematics
- Vol. 12 (2) , 240
Normalized Error-Based PI Controller and Its Application to the DC–DC Buck Converter
In this article, the structure of the normalized error-based proportional-integral (PI) controller is presented and its application to the DC–DC buck converter is discussed. The main motivation is to overcome the drawbacks of saturation and the limited range of controller gains offered by the traditional PI controller. Initially, the theoretical structure and advantages of an improved PI controller are shown. Next, the problem of regulation of the step-down DC–DC converter is addressed using the proposed controller. The objective is to keep the load voltage constant even when the converter parameters vary. The averaged state-space model of the converter is presented and a detailed stability analysis based on the Lypunov indirect method is carried out. The results show an improved range of controller parameters when the proposed controller is employed. Finally, some simulation results are shown to illustrate the effect of controller parameter variations on the output response. These results also verify the ability of the proposed controller to handle the changes in the load, input voltage, and reference voltage of the converter. Moreover, a comparative simulation study validates the superior transient response of the proposed normalized error-based PI controller over the traditional PI controller.
- 11 January 2024
- Published by MDPI AG in Mathematics
- Vol. 12 (2) , 240
Open AccessNormalized Error-Based PI Controller and Its Application to the DC–DC Buck Converter
In this article, the structure of the normalized error-based proportional-integral (PI) controller is presented and its application to the DC–DC buck converter is discussed. The main motivation is to overcome the drawbacks of saturation and the limited range of controller gains offered by the traditional PI controller. Initially, the theoretical structure and advantages of an improved PI controller are shown. Next, the problem of regulation of the step-down DC–DC converter is addressed using the proposed controller. The objective is to keep the load voltage constant even when the converter parameters vary. The averaged state-space model of the converter is presented and a detailed stability analysis based on the Lypunov indirect method is carried out. The results show an improved range of controller parameters when the proposed controller is employed. Finally, some simulation results are shown to illustrate the effect of controller parameter variations on the output response. These results also verify the ability of the proposed controller to handle the changes in the load, input voltage, and reference voltage of the converter. Moreover, a comparative simulation study validates the superior transient response of the proposed normalized error-based PI controller over the traditional PI controller.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computing
- Vol. 12 (2) , 559-571
Dynamic Reconfiguration for Resilient State Estimation Against Cyber Attacks
The increasing complexity and connectivity of critical infrastructures makes it increasingly likely that they will be subject to malicious attacks that compromise operation. Recent studies have shown that these systems are vulnerable to a wide range of cyber-attacks, including False Data Injection (FDI) attacks that bypasses conventional detection techniques. Conventional security monitoring, protection, and control tools are based primarily on passive defense strategies. In this paper, we propose an approach for active defense that improves system security and the detection rate of FDI attacks. The key insight for this approach is that emerging micro-grids can utilize distributed energy resources to dynamically reconfigure the system (e.g. power flow paths), across multiple acceptable configurations. Instead of using information from only a single static configuration to detect FDI attacks, our proposed approach uses dynamic reconfiguration to compare measured and estimated states under multiple configurations to accurately detect FDI attacks. We describe an implementation and supporting infrastructure for a secure reconfigurable microgrid. Dynamic reconfiguration also makes it more difficult for attackers to gain knowledge on the system's parameters, which increases the difficulty for attackers to construct hidden attack vectors. We evaluate our approach in the specific scenario of emerging micro-grids. We develop a novel technique for state estimation using multiple configurations and demonstrate that this approach significantly improves FDI detection accuracy.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computing
- Vol. 12 (2) , 559-571
Dynamic Reconfiguration for Resilient State Estimation Against Cyber Attacks
The increasing complexity and connectivity of critical infrastructures makes it increasingly likely that they will be subject to malicious attacks that compromise operation. Recent studies have shown that these systems are vulnerable to a wide range of cyber-attacks, including False Data Injection (FDI) attacks that bypasses conventional detection techniques. Conventional security monitoring, protection, and control tools are based primarily on passive defense strategies. In this paper, we propose an approach for active defense that improves system security and the detection rate of FDI attacks. The key insight for this approach is that emerging micro-grids can utilize distributed energy resources to dynamically reconfigure the system (e.g. power flow paths), across multiple acceptable configurations. Instead of using information from only a single static configuration to detect FDI attacks, our proposed approach uses dynamic reconfiguration to compare measured and estimated states under multiple configurations to accurately detect FDI attacks. We describe an implementation and supporting infrastructure for a secure reconfigurable microgrid. Dynamic reconfiguration also makes it more difficult for attackers to gain knowledge on the system's parameters, which increases the difficulty for attackers to construct hidden attack vectors. We evaluate our approach in the specific scenario of emerging micro-grids. We develop a novel technique for state estimation using multiple configurations and demonstrate that this approach significantly improves FDI detection accuracy.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1858-1864
Novel SVPWM based Switching Sequences for Modular Multilevel DC to AC Converter
The switching sequences for modular multilevel converters (MMCs) should also maintain sub-module voltage balance, achieve low circulation currents and low common mode voltage in addition to the general requirements such as low total harmonic distortion (THD) and ease of implementation. Space vector pulse width modulation (SVPWM) algorithm gives more flexibility in designing switching sequences compared to conventional sine-triangle pulse width modulation (SPWM). This paper proposes two novel switching sequences based on SVPWM for the complete linear modulation region of MMC. The performance of these two new sequences are compared with that of the conventional SVPWM sequences and evaluated in terms of the circulation current, sub-module voltage imbalance and common mode voltage for the complete linear modulation region. The proposed switching sequences are verified through simulation and simulation results are presented.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1858-1864
Novel SVPWM based Switching Sequences for Modular Multilevel DC to AC Converter
The switching sequences for modular multilevel converters (MMCs) should also maintain sub-module voltage balance, achieve low circulation currents and low common mode voltage in addition to the general requirements such as low total harmonic distortion (THD) and ease of implementation. Space vector pulse width modulation (SVPWM) algorithm gives more flexibility in designing switching sequences compared to conventional sine-triangle pulse width modulation (SPWM). This paper proposes two novel switching sequences based on SVPWM for the complete linear modulation region of MMC. The performance of these two new sequences are compared with that of the conventional SVPWM sequences and evaluated in terms of the circulation current, sub-module voltage imbalance and common mode voltage for the complete linear modulation region. The proposed switching sequences are verified through simulation and simulation results are presented.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 556-561
An improved space vector PWM for grid connected MMC
Multi modular converter (MMC) based DC to AC converters are widely used to interface large rating renewable energy power plants to electric grid. The performance of these converters depends on the pulse width modulation (PWM) algorithm used. This paper proposes an improved space vector PWM (SVPWM) algorithm for MMC which ensures voltage balance across each sub module and also results in low circulating current. The proposed SVPWM algorithm is verified on a 5-level MMC based DC to AC converter. The closed loop control of above converter with grid connected operation is demonstrated. The proposed SVPWM algorithm maintains balanced voltage in all sub modules and also results in low circulating current. This is demonstrated for different operating conditions through simulation.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 556-561
An improved space vector PWM for grid connected MMC
Multi modular converter (MMC) based DC to AC converters are widely used to interface large rating renewable energy power plants to electric grid. The performance of these converters depends on the pulse width modulation (PWM) algorithm used. This paper proposes an improved space vector PWM (SVPWM) algorithm for MMC which ensures voltage balance across each sub module and also results in low circulating current. The proposed SVPWM algorithm is verified on a 5-level MMC based DC to AC converter. The closed loop control of above converter with grid connected operation is demonstrated. The proposed SVPWM algorithm maintains balanced voltage in all sub modules and also results in low circulating current. This is demonstrated for different operating conditions through simulation.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 300-303
Optimum location for operation of small size distributed generators
Optimizing the size and finding the best location of required number of micro gas turbine running Distributed Generators (DG) to minimize the active power losses is the focus of this paper. Since the excitation field of the synchronous machines discussed in this paper is produced by permanent magnets, the reactive power is not controlled. To minimize the active power losses and satisfy the demand load, a two-stage approach has been proposed for the allocation and sizing of DGs in a distribution system with time-varying loads. The strategic placement of DGs can help to reduce energy losses and maintain the voltage within an acceptable boundary. The proposed method has been tested on a 9-bus test system.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 300-303
Optimum location for operation of small size distributed generators
Optimizing the size and finding the best location of required number of micro gas turbine running Distributed Generators (DG) to minimize the active power losses is the focus of this paper. Since the excitation field of the synchronous machines discussed in this paper is produced by permanent magnets, the reactive power is not controlled. To minimize the active power losses and satisfy the demand load, a two-stage approach has been proposed for the allocation and sizing of DGs in a distribution system with time-varying loads. The strategic placement of DGs can help to reduce energy losses and maintain the voltage within an acceptable boundary. The proposed method has been tested on a 9-bus test system.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Asynchronous motors fault detection using ANN and fuzzy logic methods
Detection of stator faults in their early stage is of great importance since they propagate rapidly and may cause further damage to the motor. Some variations in induction motors such as torque load anomalies must be considered in order to reliably detect stator faults. This paper presents robust artificial intelligence (AI) techniques for interturn short circuit (ITSC) fault detection of stator in three phase induction motors. In this work, the focus is first on the application of artificial neural networks and then fuzzy logic systems to reduce significantly the effect of load variations on fault detection procedure. The proposed ANN methodology has the merit to detect and locate ITSC fault, while the Fuzzy approach is capable of detecting and diagnosing the severity of ITSC fault. The simulation and experimental results are also given to verify the efficiency of both approaches under ITSC fault and load change.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Asynchronous motors fault detection using ANN and fuzzy logic methods
Detection of stator faults in their early stage is of great importance since they propagate rapidly and may cause further damage to the motor. Some variations in induction motors such as torque load anomalies must be considered in order to reliably detect stator faults. This paper presents robust artificial intelligence (AI) techniques for interturn short circuit (ITSC) fault detection of stator in three phase induction motors. In this work, the focus is first on the application of artificial neural networks and then fuzzy logic systems to reduce significantly the effect of load variations on fault detection procedure. The proposed ANN methodology has the merit to detect and locate ITSC fault, while the Fuzzy approach is capable of detecting and diagnosing the severity of ITSC fault. The simulation and experimental results are also given to verify the efficiency of both approaches under ITSC fault and load change.