Jeppe Ragnar Andersen
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jeppe Ragnar Andersen has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Asger Reinstrup Bihlet
NBCD A/S, Herlev, Denmark
4 shared publications - Jonathan Jetsmark Bjerre-Bastos
Bispebjerg Hospital
3 shared publications - Morten Asser Karsdal
Nordic Bioscience, Herlev, Denmark
3 shared publications Inger Byrjalsen
NBCD A/S Herlev Denmark
2 shared publications- Mikael Boesen
Department of Radiology, University Hospital Bispebjerg and Frederiksberg, Copenhagen, Denmark and Department of Clinical Medicine,Faculty of Health and Medical Sciences, University of, Copenhagen, Denmark
2 shared publications A. Sturmer
1 shared publication
Latest Publications
- 1 July 2024
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 32 (11) , 1471-1480
A phase 2b double-blind placebo-controlled randomized clinical trial of SB-061, an aggrecan mimetic, in patients with symptomatic knee osteoarthritis
- 1 July 2024
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 32 (11) , 1471-1480
A phase 2b double-blind placebo-controlled randomized clinical trial of SB-061, an aggrecan mimetic, in patients with symptomatic knee osteoarthritis
- 3 January 2023
- Published by Wiley in British Journal of Clinical Pharmacology
- Vol. 89 (6) , 1756-1766
Impact of monitoring approaches on data quality in clinical trials
Aims: Source data verification (SDV) has been reported to account for up to 25% of the budget in clinical trials (CT) and cost‐benefit of SDV has been questioned. Guidelines for risk‐based monitoring (RBM) were published in 2013 by agencies and in 2016, ICH‐GCP‐E6‐(R2) added a requirement for risk‐based approaches. This report will perform a comparison of the impact of RBM vs classic monitoring (CM) on data quality (defined as accuracy of data reporting from source data to final trial data) and expected impact on costs of CTs.Methods: Data on residual errors from four, large comparable randomised CTs were examined by post‐trial SDV. Observed discrepancies were analysed in the categories of “overall” data, “major efficacy” and “major safety”. In each category, the residual error rate was calculated as the number of discrepancies divided by the number of data‐fields verified.Results: A total of 1 716 087 data points were verified using CM and 323 174 using RBM. The overall error rate was 0.40% for RBM and 0.37% for CM (P < 0.01). For major efficacy, defined by risk assessment, the error rate was 0.15% and 0.28% (P < 0.0001); in major safety, defined by risk assessment, the error rate was 0.49% and 0.67% (P = 0.15), both in favour of the RBM approach.Conclusion: These empirical data, directly comparing RBM with CM, suggest that RBM improves data quality regarding data‐points of major importance to trial outcomes, efficacy and major safety. Overall, the RBM approach showed a correlation to reduced amount of data collection errors with major relevance for interpretation of study results and subject safety as well as reducing on‐site monitoring and data cleaning resources.
- 3 January 2023
- Published by Wiley in British Journal of Clinical Pharmacology
- Vol. 89 (6) , 1756-1766
Impact of monitoring approaches on data quality in clinical trials
Aims: Source data verification (SDV) has been reported to account for up to 25% of the budget in clinical trials (CT) and cost‐benefit of SDV has been questioned. Guidelines for risk‐based monitoring (RBM) were published in 2013 by agencies and in 2016, ICH‐GCP‐E6‐(R2) added a requirement for risk‐based approaches. This report will perform a comparison of the impact of RBM vs classic monitoring (CM) on data quality (defined as accuracy of data reporting from source data to final trial data) and expected impact on costs of CTs.Methods: Data on residual errors from four, large comparable randomised CTs were examined by post‐trial SDV. Observed discrepancies were analysed in the categories of “overall” data, “major efficacy” and “major safety”. In each category, the residual error rate was calculated as the number of discrepancies divided by the number of data‐fields verified.Results: A total of 1 716 087 data points were verified using CM and 323 174 using RBM. The overall error rate was 0.40% for RBM and 0.37% for CM (P < 0.01). For major efficacy, defined by risk assessment, the error rate was 0.15% and 0.28% (P < 0.0001); in major safety, defined by risk assessment, the error rate was 0.49% and 0.67% (P = 0.15), both in favour of the RBM approach.Conclusion: These empirical data, directly comparing RBM with CM, suggest that RBM improves data quality regarding data‐points of major importance to trial outcomes, efficacy and major safety. Overall, the RBM approach showed a correlation to reduced amount of data collection errors with major relevance for interpretation of study results and subject safety as well as reducing on‐site monitoring and data cleaning resources.
- Open Access
- 5 August 2022
- Published by Wolters Kluwer Health in Pain Reports
- Vol. 7 (5)
Associations between single-question Visual Analogue Scale pain score and weight-bearing and non–weight-bearing domains of Western Ontario and McMaster Universities Arthritis Index pain: data from 2 phase 3 clinical trials
Introduction: Visual Analogue Scale (VAS) and the pain subscale of the Western Ontario and McMaster Universities Arthritis Index (WOMAC) are commonly used measuring tools of osteoarthritis (OA) pain. Objectives: The objective of this cross-sectional study was to explore the associations between single-question VAS pain and the weight-bearing and non–weight-bearing domains of WOMAC pain. Methods: Data from 2093 patients with OA participating in 2 phase 3 clinical trials were included for post hoc analyses. Univariate Pearson correlations and comparison of r values were made using z statistics obtained using the Fisher r to z test for all items of the VAS pain scale, the WOMAC pain subscale, the weight-bearing and non–weight-bearing constructs of WOMAC pain subscale, and by subgroups of WOMAC pain quintiles and Kellgren–Lawrence grades. Results: The correlations between VAS pain and WOMAC pain were significant (r = 0.67, P < 0.001) with a slope of 0.57 (95% confidence interval [CI]: 0.54–0.61). A similar correlation was found for weight-bearing pain (r = 0.68, P < 0.001, slope: 0.62 (95% CI: 0.59–0.65) but significantly lower for non–weight-bearing pain (r = 0.55, P < 0.001, slope: 0.49 (95% CI: 0.46–0.52). The degree of disagreement between the 2 instruments seemed to be lesser in the extreme ends of the scales, and the observed association between Kellgren–Lawrence grade and disagreement between VAS and WOMAC was driven by non–weight-bearing pain. Conclusion: In conclusion, VAS pain and WOMAC pain subscale correlation was found to be moderate and the VAS pain scale correlated more accurately with the WOMAC pain weight-bearing questions. This constitutes novel insight into patient with OA pain reporting.
- 5 August 2022
- Published by Wolters Kluwer Health in Pain Reports
- Vol. 7 (5)
Open AccessAssociations between single-question Visual Analogue Scale pain score and weight-bearing and non–weight-bearing domains of Western Ontario and McMaster Universities Arthritis Index pain: data from 2 phase 3 clinical trials
Introduction: Visual Analogue Scale (VAS) and the pain subscale of the Western Ontario and McMaster Universities Arthritis Index (WOMAC) are commonly used measuring tools of osteoarthritis (OA) pain. Objectives: The objective of this cross-sectional study was to explore the associations between single-question VAS pain and the weight-bearing and non–weight-bearing domains of WOMAC pain. Methods: Data from 2093 patients with OA participating in 2 phase 3 clinical trials were included for post hoc analyses. Univariate Pearson correlations and comparison of r values were made using z statistics obtained using the Fisher r to z test for all items of the VAS pain scale, the WOMAC pain subscale, the weight-bearing and non–weight-bearing constructs of WOMAC pain subscale, and by subgroups of WOMAC pain quintiles and Kellgren–Lawrence grades. Results: The correlations between VAS pain and WOMAC pain were significant (r = 0.67, P < 0.001) with a slope of 0.57 (95% confidence interval [CI]: 0.54–0.61). A similar correlation was found for weight-bearing pain (r = 0.68, P < 0.001, slope: 0.62 (95% CI: 0.59–0.65) but significantly lower for non–weight-bearing pain (r = 0.55, P < 0.001, slope: 0.49 (95% CI: 0.46–0.52). The degree of disagreement between the 2 instruments seemed to be lesser in the extreme ends of the scales, and the observed association between Kellgren–Lawrence grade and disagreement between VAS and WOMAC was driven by non–weight-bearing pain. Conclusion: In conclusion, VAS pain and WOMAC pain subscale correlation was found to be moderate and the VAS pain scale correlated more accurately with the WOMAC pain weight-bearing questions. This constitutes novel insight into patient with OA pain reporting.
- 22 June 2021
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 121 (10) , 2799-2809
A biomarker perspective on the acute effect of exercise with and without impact on joint tissue turnover: an exploratory randomized cross-over study
Purpose To investigate acute changes in biochemical markers of bone and cartilage turnover in response to moderate intensity exercise with and without joint impact in healthy human subjects. Methods A randomized, cross-over, exploratory, clinical study was conducted. Twenty healthy subjects with no history of joint trauma completed 30 min interventions of standardized moderate intensity cycling and running as well as a resting intervention 1 week apart. Blood samples were taken immediately before, four times after exercise and again the next day. Urine was sampled, before, after and the next day. On the day of rest, samples were taken at timepoints similar to the days of exercise. Markers of type I (CTX-I), II (C2M, CTX-II) and VI (C6M) collagen degradation, cartilage oligomeric matrix protein (COMP) and procollagen C-2 (PRO-C2) was measured. Trial registration number: NCT04542655, 02 September 2020, retrospectively registered. Results CTX-I was different from cycling (4.2%, 95%CI: 0.4–8.0%, p = 0.03) and resting (6.8%, 95%CI: 2.9–10.7%, p = 0.001) after running and the mean change in COMP was different from cycling (10.3%, 95%CI: 1.1–19.5%, p = 0.03), but not from resting (8.6%, 95%CI: − 0.7–17.8%, p = 0.07) after running. Overall, changes in other biomarkers were not different between interventions. Conclusion In this exploratory study, running, but not cycling, at a moderate intensity and duration induced acute changes in biomarkers of bone and cartilage extra-cellular matrix turnover.
- 22 June 2021
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 121 (10) , 2799-2809
A biomarker perspective on the acute effect of exercise with and without impact on joint tissue turnover: an exploratory randomized cross-over study
Purpose To investigate acute changes in biochemical markers of bone and cartilage turnover in response to moderate intensity exercise with and without joint impact in healthy human subjects. Methods A randomized, cross-over, exploratory, clinical study was conducted. Twenty healthy subjects with no history of joint trauma completed 30 min interventions of standardized moderate intensity cycling and running as well as a resting intervention 1 week apart. Blood samples were taken immediately before, four times after exercise and again the next day. Urine was sampled, before, after and the next day. On the day of rest, samples were taken at timepoints similar to the days of exercise. Markers of type I (CTX-I), II (C2M, CTX-II) and VI (C6M) collagen degradation, cartilage oligomeric matrix protein (COMP) and procollagen C-2 (PRO-C2) was measured. Trial registration number: NCT04542655, 02 September 2020, retrospectively registered. Results CTX-I was different from cycling (4.2%, 95%CI: 0.4–8.0%, p = 0.03) and resting (6.8%, 95%CI: 2.9–10.7%, p = 0.001) after running and the mean change in COMP was different from cycling (10.3%, 95%CI: 1.1–19.5%, p = 0.03), but not from resting (8.6%, 95%CI: − 0.7–17.8%, p = 0.07) after running. Overall, changes in other biomarkers were not different between interventions. Conclusion In this exploratory study, running, but not cycling, at a moderate intensity and duration induced acute changes in biomarkers of bone and cartilage extra-cellular matrix turnover.
- 20 March 2020
- Published by Wiley in Translational Sports Medicine
- Vol. 3 (5) , 384-394
The acute and long‐term impact of physical activity on biochemical markers and MRI measures in osteoarthritis—Perspectives for clinical osteoarthritis research
- 20 March 2020
- Published by Wiley in Translational Sports Medicine
- Vol. 3 (5) , 384-394
The acute and long‐term impact of physical activity on biochemical markers and MRI measures in osteoarthritis—Perspectives for clinical osteoarthritis research
- Open Access
- 23 March 2015
- Published by Wiley in British Journal of Clinical Pharmacology
- Vol. 79 (4) , 660-668
Impact of source data verification on data quality in clinical trials: an empirical post hoc analysis of three phase 3 randomized clinical trials
Aim: The aim of this project was to perform an empirical evaluation of the impact of on site source data verification (SDV) on the data quality in a clinical trial database to guide an informed decision on selection of the monitoring approach.Methods: We used data from three randomized phase III trials monitored with a combination of complete SDV or partial SDV. After database lock, individual subject data were extracted from the clinical database and subjected to post hoc complete SDV. Error rates were calculated with focus on the degree of on study monitoring and relevance and analyzed for potential impact on end points.Results: Data from a total of 2566 subjects including more than 3 million data fields were 100% source data verified post hoc. An overall error rate of 0.45% was found. No sites had 0% errors. 100% SDV yielded an error rate of 0.27% as compared with partial SDV having an error rate of 0.53% (P < 0.0001). Comparing partly and fully monitored subjects, minor differences were identified between variables of major importance to efficacy or safety.Conclusions: The findings challenge the notion that a 0% error rate is obtainable with on site monitoring. Data indicate consistently low error rates across the three trials analyzed. The use of complete vs. partial SDV offers a marginal absolute error rate reduction of 0.26%, i.e. a need to perform complete SDV of about 370 data points to avoid one unspecified error and does not support complete SDV as a means of providing meaningful improvements in data accuracy.
- 23 March 2015
- Published by Wiley in British Journal of Clinical Pharmacology
- Vol. 79 (4) , 660-668
Open AccessImpact of source data verification on data quality in clinical trials: an empirical post hoc analysis of three phase 3 randomized clinical trials
Aim: The aim of this project was to perform an empirical evaluation of the impact of on site source data verification (SDV) on the data quality in a clinical trial database to guide an informed decision on selection of the monitoring approach.Methods: We used data from three randomized phase III trials monitored with a combination of complete SDV or partial SDV. After database lock, individual subject data were extracted from the clinical database and subjected to post hoc complete SDV. Error rates were calculated with focus on the degree of on study monitoring and relevance and analyzed for potential impact on end points.Results: Data from a total of 2566 subjects including more than 3 million data fields were 100% source data verified post hoc. An overall error rate of 0.45% was found. No sites had 0% errors. 100% SDV yielded an error rate of 0.27% as compared with partial SDV having an error rate of 0.53% (P < 0.0001). Comparing partly and fully monitored subjects, minor differences were identified between variables of major importance to efficacy or safety.Conclusions: The findings challenge the notion that a 0% error rate is obtainable with on site monitoring. Data indicate consistently low error rates across the three trials analyzed. The use of complete vs. partial SDV offers a marginal absolute error rate reduction of 0.26%, i.e. a need to perform complete SDV of about 370 data points to avoid one unspecified error and does not support complete SDV as a means of providing meaningful improvements in data accuracy.