Kostas Syriopoulos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kostas Syriopoulos has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Paul Frans van der Stelt
Department of Oral Radiology, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Netherlands
4 shared publications Kostas Tsiklakis
Oral Diagnosis and Radiology Clinic, School of Dentistry, National and Kapodistrian University, Athens, Greece
2 shared publications- Azin Parsa
Department of Oncology and Diagnostic Sciences, University of Maryland School of Dentistry, Baltimore, MD, USA
1 shared publication - Bassam Hassan
Infectious Diseases, Hackensack Meridian Ocean Medical Center, Brick, USA
1 shared publication G C Sanderink
Department of Oral Radiology , Academic Centre for Dentistry Amsterdam (ACTA), The Netherlands
1 shared publicationG Li
1 shared publication
Latest Publications
- 11 November 2014
- Published by Medical Journals Sweden AB in Acta Odontologica Scandinavica
- Vol. 73 (3) , 202-209
Extra- and intra-cranial arterial calcifications in adults depicted as incidental findings on cone beam CT images
The aim of this study was to evaluate, retrospectively, the gender- and age-related prevalence of incidentally found calcifications, depicted within the course of the extra- and intra-cranial portion of internal carotid artery (ICA), in cone beam computed tomography (CBCT) examinations in adults, and to assess their clinical significance. Out of a pull of 700 CBCT examinations a total of 484 CBCT scans of adult patients were finally selected according to a set of pre-defined criteria. These were evaluated for arterial calcifications presence within the ICAs course according to gender and age criteria. In total, 492 calcifications were detected: 211 (42.88%) extra-cranial and 281 (57.11%) intra-cranial. Those were recorded in 150 scans (30.99%) and 161 scans (33.26%), respectively. Calcifications, with either extra- or intra-cranial allocation, were found more frequent in males than in females (all p-values < 0.05); also patients who presented with positive findings were older than those without findings (all p-values < 0.05). Furthermore, calcification presence with either extra- or intra-cranial allocation increases with age (all p-values < 0.05). Significant calcification frequencies were found within the ICA's course, in CBCT scans. Moreover, an increased incidence of either extra- or intra-cranial presence of these depictions and its relation to age and gender was documented.
- 11 November 2014
- Published by Medical Journals Sweden AB in Acta Odontologica Scandinavica
- Vol. 73 (3) , 202-209
Extra- and intra-cranial arterial calcifications in adults depicted as incidental findings on cone beam CT images
The aim of this study was to evaluate, retrospectively, the gender- and age-related prevalence of incidentally found calcifications, depicted within the course of the extra- and intra-cranial portion of internal carotid artery (ICA), in cone beam computed tomography (CBCT) examinations in adults, and to assess their clinical significance. Out of a pull of 700 CBCT examinations a total of 484 CBCT scans of adult patients were finally selected according to a set of pre-defined criteria. These were evaluated for arterial calcifications presence within the ICAs course according to gender and age criteria. In total, 492 calcifications were detected: 211 (42.88%) extra-cranial and 281 (57.11%) intra-cranial. Those were recorded in 150 scans (30.99%) and 161 scans (33.26%), respectively. Calcifications, with either extra- or intra-cranial allocation, were found more frequent in males than in females (all p-values < 0.05); also patients who presented with positive findings were older than those without findings (all p-values < 0.05). Furthermore, calcification presence with either extra- or intra-cranial allocation increases with age (all p-values < 0.05). Significant calcification frequencies were found within the ICA's course, in CBCT scans. Moreover, an increased incidence of either extra- or intra-cranial presence of these depictions and its relation to age and gender was documented.
- Open Access
- 1 October 2014
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 43 (7) , 20140019
Assessment of metal artefact reduction around dental titanium implants in cone beam CT
The aim of this study was to investigate if the metal artefact reduction (MAR) tool used in the software of the ORTHOPANTOMOGRAPH(®) OP300 (Instrumentarium Dental, Tuusula, Finland) can improve the gray value levels in post-operative implant scans. 20 potential implant sites were selected from 5 edentulous human dry mandibles. Each mandible was scanned by a CBCT scanner, and images were produced under three different conditions: implant sites drilled but no implants inserted, implants inserted without application of MAR and implants inserted with application of MAR. Using Geomagic(®) Studio 2012 (Geomagic, Morrisville, NC) and 3Diagnosys(®) v. 5.3.1 (3Diemme(®) SRL, Cantù, Italy) software, three scans of each mandible were superimposed. The mean gray value of identical regions of bone around the implants was derived for each condition. The differences between gray value measurements at implant sites derived from different conditions were assessed. A significant difference was found between mean gray values from the scans with no implants inserted and with implants inserted (with and without MAR) (p = 0.012). No significant difference was revealed for gray values measured from scans with and without MAR (p = 0.975). The MAR tool in the software of the ORTHOPANTOMOGRAPH OP300 CBCT scanner does not significantly correct the voxel gray values affected by the metal artefact in the vicinity of an implant in human dry mandibles.
- 1 October 2014
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 43 (7) , 20140019
Open AccessAssessment of metal artefact reduction around dental titanium implants in cone beam CT
The aim of this study was to investigate if the metal artefact reduction (MAR) tool used in the software of the ORTHOPANTOMOGRAPH(®) OP300 (Instrumentarium Dental, Tuusula, Finland) can improve the gray value levels in post-operative implant scans. 20 potential implant sites were selected from 5 edentulous human dry mandibles. Each mandible was scanned by a CBCT scanner, and images were produced under three different conditions: implant sites drilled but no implants inserted, implants inserted without application of MAR and implants inserted with application of MAR. Using Geomagic(®) Studio 2012 (Geomagic, Morrisville, NC) and 3Diagnosys(®) v. 5.3.1 (3Diemme(®) SRL, Cantù, Italy) software, three scans of each mandible were superimposed. The mean gray value of identical regions of bone around the implants was derived for each condition. The differences between gray value measurements at implant sites derived from different conditions were assessed. A significant difference was found between mean gray values from the scans with no implants inserted and with implants inserted (with and without MAR) (p = 0.012). No significant difference was revealed for gray values measured from scans with and without MAR (p = 0.975). The MAR tool in the software of the ORTHOPANTOMOGRAPH OP300 CBCT scanner does not significantly correct the voxel gray values affected by the metal artefact in the vicinity of an implant in human dry mandibles.
- 7 June 2010
- Published by Wiley in Clinical Oral Implants Research
- Vol. 21 (7) , 766-771
Evaluation of the visibility and the course of the mandibular incisive canal and the lingual foramen using cone‐beam computed tomography
Objectives: To assess the visibility and the course of the incisive canal and the visibility and the location of the lingual foramen using cone‐beam computed tomography (CBCT).Methods: In total, 100 CBCT examinations of patients for preoperative planning were used for this study. The examinations were taken using the NewTom 3G CBCT unit, applying a standardized exposure protocol. Image reconstruction from the raw data was performed using the NewTom software. Three experts were asked to assess the visibility of the incisive canal using a four‐point rating scale. The position of the incisive canal was recorded in relation to the lower, buccal and lingual border of the mandible using the application provided by the CBCT software.Results: The incisive canal was definitely visible in 83.5% of the scans and the mean endpoint was approximately 15 mm anterior to the mental foramen. The mean distance from the lower border of the mandible was 11.5 mm and its course was closer to the buccal border of the mandible in 87% of the scans. The lingual foramen was definitely visible in 81% of the scans.Conclusions: The high detection rate of the incisive canal and the lingual foramen in the anterior region of the mandible using CBCT indicates the potentional high preoperative value of CBCT scan for surgical procedures in the anterior mandible. To cite this article: Makris N, Stamatakis H, Syriopoulos K, Tsiklakis K, van der Stelt PF. Evaluation of the visibility and the course of the mandibular incisive canal and the lingual foramen using cone‐beam computed tomography. Clin. Oral Impl. Res. 21, 2010; 766–771. doi: 10.1111/j.1600‐0501.2009.01903.x
- 7 June 2010
- Published by Wiley in Clinical Oral Implants Research
- Vol. 21 (7) , 766-771
Evaluation of the visibility and the course of the mandibular incisive canal and the lingual foramen using cone‐beam computed tomography
Objectives: To assess the visibility and the course of the incisive canal and the visibility and the location of the lingual foramen using cone‐beam computed tomography (CBCT).Methods: In total, 100 CBCT examinations of patients for preoperative planning were used for this study. The examinations were taken using the NewTom 3G CBCT unit, applying a standardized exposure protocol. Image reconstruction from the raw data was performed using the NewTom software. Three experts were asked to assess the visibility of the incisive canal using a four‐point rating scale. The position of the incisive canal was recorded in relation to the lower, buccal and lingual border of the mandible using the application provided by the CBCT software.Results: The incisive canal was definitely visible in 83.5% of the scans and the mean endpoint was approximately 15 mm anterior to the mental foramen. The mean distance from the lower border of the mandible was 11.5 mm and its course was closer to the buccal border of the mandible in 87% of the scans. The lingual foramen was definitely visible in 81% of the scans.Conclusions: The high detection rate of the incisive canal and the lingual foramen in the anterior region of the mandible using CBCT indicates the potentional high preoperative value of CBCT scan for surgical procedures in the anterior mandible. To cite this article: Makris N, Stamatakis H, Syriopoulos K, Tsiklakis K, van der Stelt PF. Evaluation of the visibility and the course of the mandibular incisive canal and the lingual foramen using cone‐beam computed tomography. Clin. Oral Impl. Res. 21, 2010; 766–771. doi: 10.1111/j.1600‐0501.2009.01903.x
- 1 May 2007
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 36 (4) , 204-210
Detection of proximal caries with high-resolution and standard resolution digital radiographic systems
Aims: The aim of this study was to: (1) compare the diagnostic accuracy of the high-resolution and standard resolution settings of four digital imaging systems for caries diagnosis and (2) compare the effect on the diagnostic accuracy of reducing the high-resolution image sizes to the standard resolution dimensions, and vice versa. Materials and methods: 90 extracted human premolars were mounted in groups of 5 in plaster blocks, containing 4 test teeth and 1 non-test tooth. Two blocks at a time were placed in a jig to simulate a bitewing radiograph. Radiographs were taken using four digital systems (Planmeca Dixi 2; Gendex Visualix HDI; Dürr Vistascan; Digora Optime), each at two resolution settings. Next, the teeth were sectioned and a total of 65 surfaces were incorporated in the study. Additionally, the bicubic interpolation method was applied to reduce the high-resolution original images and to enlarge the standard resolution images. The original, reduced and enlarged images were randomly shown to five observers in two random sessions. The observers were asked to assess caries depth on a 4-point scale. The observers' scores were compared with the results from a histological examination. Data were analysed using the statistical theory for multivariate discrete data. Cohen's kappa was used to determine the agreement with the gold standard. Results: None of the comparisons between the spatial resolution settings, or the comparisons between increased or reduced image size and the original image sizes, showed significant differences in the probability of caries detection (χ2=26.59, df=26, P∼0.50). The four digital systems used in this study differ significantly in the probability of caries detection (χ2=41.55, df=24, P<0.02). Compared with the gold standard, the Gendex Visualix HDI CCD sensor has the highest measure of agreement (kappa=0.31). Conclusion: Caries diagnosis does not improve when using high-resolution settings compared with the standard settings. The use of bicubic convolution interpolation for zooming has no detectable effect on caries diagnosis and therefore is recommended to use when enlarging or reducing radiographs. The probability of caries detection, however, was different for the sensor systems of the different manufacturers.
- 1 May 2007
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 36 (4) , 204-210
Detection of proximal caries with high-resolution and standard resolution digital radiographic systems
Aims: The aim of this study was to: (1) compare the diagnostic accuracy of the high-resolution and standard resolution settings of four digital imaging systems for caries diagnosis and (2) compare the effect on the diagnostic accuracy of reducing the high-resolution image sizes to the standard resolution dimensions, and vice versa. Materials and methods: 90 extracted human premolars were mounted in groups of 5 in plaster blocks, containing 4 test teeth and 1 non-test tooth. Two blocks at a time were placed in a jig to simulate a bitewing radiograph. Radiographs were taken using four digital systems (Planmeca Dixi 2; Gendex Visualix HDI; Dürr Vistascan; Digora Optime), each at two resolution settings. Next, the teeth were sectioned and a total of 65 surfaces were incorporated in the study. Additionally, the bicubic interpolation method was applied to reduce the high-resolution original images and to enlarge the standard resolution images. The original, reduced and enlarged images were randomly shown to five observers in two random sessions. The observers were asked to assess caries depth on a 4-point scale. The observers' scores were compared with the results from a histological examination. Data were analysed using the statistical theory for multivariate discrete data. Cohen's kappa was used to determine the agreement with the gold standard. Results: None of the comparisons between the spatial resolution settings, or the comparisons between increased or reduced image size and the original image sizes, showed significant differences in the probability of caries detection (χ2=26.59, df=26, P∼0.50). The four digital systems used in this study differ significantly in the probability of caries detection (χ2=41.55, df=24, P<0.02). Compared with the gold standard, the Gendex Visualix HDI CCD sensor has the highest measure of agreement (kappa=0.31). Conclusion: Caries diagnosis does not improve when using high-resolution settings compared with the standard settings. The use of bicubic convolution interpolation for zooming has no detectable effect on caries diagnosis and therefore is recommended to use when enlarging or reducing radiographs. The probability of caries detection, however, was different for the sensor systems of the different manufacturers.
- 1 April 2007
- Published by S. Karger AG in Caries Research
- Vol. 41 (3) , 231-234
Detection of Proximal Caries in vitro Using Standard and Task-Specific Enhanced Images from a Storage Phosphor Plate System
Eight dentists evaluated 72 proximal surfaces of premolars with respect to all caries lesions and to lesions into dentine in digital images from a storage phosphor plate system. The images were processed in four different ways: (1) the default algorithm of the standard imaging system (DF); (2) an algorithm correcting for attenuation and visual response (AV), and two proprietary caries-specific enhancement algorithms (3) K1, and (4) K2, respectively. The lesions were validated by histological examination. There were no significant differences in the areas under the receiver operating characteristic curves between differently processed radiographs for the categories of all caries lesions and caries into dentine.
- 1 April 2007
- Published by S. Karger AG in Caries Research
- Vol. 41 (3) , 231-234
Detection of Proximal Caries in vitro Using Standard and Task-Specific Enhanced Images from a Storage Phosphor Plate System
Eight dentists evaluated 72 proximal surfaces of premolars with respect to all caries lesions and to lesions into dentine in digital images from a storage phosphor plate system. The images were processed in four different ways: (1) the default algorithm of the standard imaging system (DF); (2) an algorithm correcting for attenuation and visual response (AV), and two proprietary caries-specific enhancement algorithms (3) K1, and (4) K2, respectively. The lesions were validated by histological examination. There were no significant differences in the areas under the receiver operating characteristic curves between differently processed radiographs for the categories of all caries lesions and caries into dentine.
- Top Cited Papers
- 1 May 2004
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 33 (3) , 196-201
Radiographic examination of the temporomandibular joint using cone beam computed tomography
Cone beam CT (CBCT) is a new technique for maxillofacial imaging. We describe a reconstruction technique for radiographic examination of the temporomandibular joint (TMJ) using CBCT, and we further present four cases where the technique was employed. The technique provides a complete radiographic investigation of the bony components of the TMJ. The reconstructed images are of high diagnostic quality. The examination time is shorter and the patient dose is lower than that with conventional CT. It may therefore be considered as the imaging technique of choice when investigation of bony changes of the TMJ is the task at hand.
- 1 May 2004
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 33 (3) , 196-201
Top Cited PapersRadiographic examination of the temporomandibular joint using cone beam computed tomography
Cone beam CT (CBCT) is a new technique for maxillofacial imaging. We describe a reconstruction technique for radiographic examination of the temporomandibular joint (TMJ) using CBCT, and we further present four cases where the technique was employed. The technique provides a complete radiographic investigation of the bony components of the TMJ. The reconstructed images are of high diagnostic quality. The examination time is shorter and the patient dose is lower than that with conventional CT. It may therefore be considered as the imaging technique of choice when investigation of bony changes of the TMJ is the task at hand.
- 1 September 2000
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 29 (5) , 312-318
Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems
OBJECTIVES: To compare the diagnostic accuracy for the detection of approximal caries of two dental X-ray films, two CCD-based digital systems and two storage phosphor (SP) digital systems. METHODS: Fifty-six surfaces in 56 extracted unrestored premolars were radiographed under standardised conditions using two E-speed dental film, Ektaspeed Plus (Eastman Kodak Co, Rochester, NY, USA) and Dentus M2 Comfort (Agfa-Gevaert, Mortsel, Belgium), two CCD systems, Sidexis (Sirona, Bensheim, Germany) and Visualix (Gendex, Milan, Italy) and two SP systems, Digora (Soredex, Helsinki, Finland) and DenOptix (Gendex, Milano, Italy). The images were assessed by eight observers (four radiologists and four general practitioners). True caries depth was determined by histological examination. True caries depth was subtracted from the values given by the observers and an analysis of variance was performed. The null hypothesis was rejected when P < 0.05. RESULTS: No significant differences were found in diagnostic accuracy with the two dental films and the Sidexis and Digora systems. The depth of the lesion significantly affected observer performance. Caries depth was underestimated. Radiologists performed significantly better than general practitioners whatever the recording system. CONCLUSION: The diagnostic accuracy of digital systems is comparable with that of dental films. The ability of dentists to recognise caries correctly is the main factor contributing to variation in radiographic diagnosis and not the imaging modality.
- 1 September 2000
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 29 (5) , 312-318
Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems
OBJECTIVES: To compare the diagnostic accuracy for the detection of approximal caries of two dental X-ray films, two CCD-based digital systems and two storage phosphor (SP) digital systems. METHODS: Fifty-six surfaces in 56 extracted unrestored premolars were radiographed under standardised conditions using two E-speed dental film, Ektaspeed Plus (Eastman Kodak Co, Rochester, NY, USA) and Dentus M2 Comfort (Agfa-Gevaert, Mortsel, Belgium), two CCD systems, Sidexis (Sirona, Bensheim, Germany) and Visualix (Gendex, Milan, Italy) and two SP systems, Digora (Soredex, Helsinki, Finland) and DenOptix (Gendex, Milano, Italy). The images were assessed by eight observers (four radiologists and four general practitioners). True caries depth was determined by histological examination. True caries depth was subtracted from the values given by the observers and an analysis of variance was performed. The null hypothesis was rejected when P < 0.05. RESULTS: No significant differences were found in diagnostic accuracy with the two dental films and the Sidexis and Digora systems. The depth of the lesion significantly affected observer performance. Caries depth was underestimated. Radiologists performed significantly better than general practitioners whatever the recording system. CONCLUSION: The diagnostic accuracy of digital systems is comparable with that of dental films. The ability of dentists to recognise caries correctly is the main factor contributing to variation in radiographic diagnosis and not the imaging modality.