Derek Ho

Derek Ho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Derek Ho has a total of 90 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Shock waves generated by toroidal bubble collapse are imperative for kidney stone dusting during Holmium:YAG laser lithotripsy

    by Gaoming Xiang, Junqin Chen, Derek Ho, Georgy Sankin, Xuning Zhao, Yangyuanchen Liu, Kevin Wang, John Dolbow, Junjie Yao, Pei Zhong


  • Cavitation Plays a Vital Role in Stone Dusting During Short Pulse Holmium:YAG Laser Lithotripsy

    by Junqin Chen, Derek S. Ho, Gaoming Xiang, Georgy Sankin, Glenn M. Preminger, Michael Eric Lipkin, Pei Zhong

    Objective: To investigate the mechanism of stone dusting in Holmium (Ho): YAG laser lithotripsy (LL). Materials and Methods: Cylindrical BegoStone samples (6 x 6 mm, H x D) were treated in water using a clinical Ho: YAG laser lithotripter in dusting mode (0.2 ~ 0.4 J with 70 ~ 78 s in pulse duration, 20 Hz) at various fiber tip to stone standoff distances (SD = 0, 0.5, and 1 mm). Stone damage craters were quantified by optical coherence tomography and bubble dynamics were captured by high-speed video imaging. To differentiate the contribution of cavitation vs. thermal ablation to stone damage, three additional experiments were performed. First, pre-soaked wet stones were treated in air to assess stone damage without cavitation. Second, the laser fiber was advanced at various offset distances (OSD = 0.25, 1, 2, 3, and 10 mm) from the tip of a flexible ureteroscope to alter the dynamics of bubble collapse. Third, stones were treated with parallel fiber to minimize photothermal damage while isolating the contribution of cavitation to stone damage. Results: Treatment in water resulted in 2.5- to 90-fold increase in stone damage compared to those produced in air where thermal ablation dominates. With the fiber tip placed at OSD = 0.25 mm, the collapse of the bubble was distracted away from the stone surface by the ureteroscope tip, leading to significantly reduced stone damage compared to treatment without the scope or with scope at large OSD of 3 ~ 10 mm. The average crater volume produced by parallel fiber orientation at 0.2 J after 100 pulses where cavitation is the dominant mechanism of stone damage was comparable with those produced by using perpendicular fiber orientation within SD = 0.25 ~ 1 mm. Conclusion: Cavitation plays a dominant role over photothermal ablation in stone dusting during short pulse Ho: YAG LL.


  • Comparison of Different Pulse Modulation Modes for Holmium:Yttrium–Aluminum–Garnet Laser Lithotripsy Ablation in a Benchtop Model

    by Russell Stevens Terry, Derek S. Ho, Dominick M. Scialabba, Patrick S. Whelan, Robert Qi, Brian Thomas Ketterman, Glenn M. Preminger, Pei Zhong, Michael Eric Lipkin

    Introduction: Manipulation of Holmium:Yttrium–Aluminum–Garnet laser parameters such as pulse energy (PE), frequency, and duration can impact laser lithotripsy ablation efficiency. In 2017, Lumenis introduced Moses™ Technology, which uses pulse modulation to enhance the delivery of energy from fiber to stone as well as to minimize stone retropulsion. Since the introduction of Moses Technology, other companies have brought additional pulse modulation concepts to market. The purpose of this in vitro study is to compare the pulse characteristics and stone ablation efficiency of Lumenis Moses Technology with Quanta's Vapor Tunnel™. Materials and Methods: Submerged BegoStone phantoms were systematically ablated using either the Lumenis Moses Pulse 120H or the Quanta Litho 100 clinical laser system. Two PEs (0.4 and 1 J), three fiber-stone standoff distances (SDs) (0.5, 1, 2 mm), and all available pulse duration and modulation modes for each laser were tested in combination. Fiber speed was adjusted to scan across the stone surface at either 1 or 10 pulses/mm to form single pulse craters or an ablation trough, respectively. Volumes of single craters and 1 mm trough segments were imaged and quantified using optical coherence tomography. Results: Ablation volumes decreased with decreasing PE and increasing SD. Statistically significant variability was seen between pulse types (PT) at every tested parameter set. Among pulse modulation modes, Moses Distance (MD) was superior at 0.5 mm in all testing and at 2 mm in trough testing. Vapor Tunnel (VT) was superior in 2 mm single crater testing. All modulated pulses performed similarly at 1 mm. Conclusions: In this benchtop model of laser lithotripsy, stone ablation was significantly impacted by PT. MD demonstrated superior or noninferior stone ablation at most tested parameters. VT maintained its efficacy the best as SD increased. Future work should focus on the mechanistic differences of these modes relative to other traditional laser pulse modes.


  • The Role of Cavitation in Energy Delivery and Stone Damage During Laser Lithotripsy

    by Derek S. Ho, Dominick Scialabba, Russell Stevens Terry, Xiaojian Ma, Junqin Chen, Georgy N. Sankin, Gaoming Xiang, Robert Qi, Glenn M. Preminger, Michael Eric Lipkin, et al.

    Purpose: While cavitation during laser lithotripsy contributes to the Moses effect, the impact of cavitation on stone damage is less clear. Using different laser settings, we investigate the role of cavitation bubbles in energy delivery and stone damage. Materials and Methods: The role of cavitation in laser energy delivery was characterized using photodetector measurements synced with high-speed imaging for laser pulses of varying durations. BegoStone samples were treated with the laser fiber oriented perpendicularly in contact with the stone in water or in air to assess the impact of cavitation on crater formation. Crater volume and geometry were quantified using optical coherence tomography. Furthermore, the role of cavitation in stone damage was elucidated by treatment in water with the fiber oriented parallel to the stone surface and by photoelastic imaging. Results: Longer pulse durations resulted in higher energy delivery but smaller craters. Stones treated in water resulted in greater volume, wider yet shallower craters compared to those treated in air. Stones treated with the parallel fiber showed crater formation after 15 pulses, confirmed by high-speed imaging of the bubble collapse with the resultant stress field captured by photoelastic imaging. Conclusions: Despite improved energy delivery, the longer pulse mode produced smaller crater volume, suggesting additional processes secondary to photothermal ablation are involved in stone damage. Our critical observations of the difference in stone damage treated in water vs. in air, combined with the crater formation by parallel fiber suggest that cavitation is a contributor to stone damage during laser lithotripsy.


  • Progress in angle-resolved low-coherence interferometry for real-time detection of epithelial dysplasia (Conference Presentation)

    by Zachary A. Steelman, Derek Ho, Yang Zhao, Haoran Zhang, Evan Jelly, Ge Song, Wesley Y. Kendall, Michael Crose, Brian Cox, Kengyeh K. Chu, et al.

    Angle-resolved low-coherence interferometry (a/LCI) is an optical technique which uses inverse models of light scattering to predict the size and density of cell nuclei, a significant biomarker of precancer. In recent years, substantial progress has occurred in a/LCI technology, particularly in novel instrumentation for the detection of dysplasia in the cervix and the esophagus. This abstract summarizes recent developments in a/LCI, with a focus on developments over the previous four years. Clinical studies in the cervix, novel optical instrumentation addressing the cervix and esophagus, and novel applications related to Alzheimer’s disease are discussed.

  • Light-scattering methods for tissue diagnosis

    by Zachary A. Steelman, Derek S. Ho, Kengyeh K. Chu, Adam Wax

    Light scattering has become a common biomedical research tool, enabling diagnostic sensitivity to myriad tissue alterations associated with disease. Light–tissue interactions are particularly attractive for diagnostics due to the variety of contrast mechanisms that can be used, including spectral, angle-resolved, and Fourier-domain detection. Photonic diagnostic tools offer further benefits in that they are non-ionizing, non-invasive, and give real-time feedback. In this review, we summarize recent innovations in light-scattering technologies, with a focus on clinical achievements over the previous ten years.


  • Angular range, sampling and noise considerations for inverse light scattering analysis of nuclear morphology

    by Haoran Zhang, Zachary A. Steelman, Derek S. Ho, Kengyeh K. Chu, Adam Wax

    In recent years, significant work has been devoted to the use of angle‐resolved elastic scattering for the extraction of nuclear morphology in tissue. By treating the nucleus as a Mie scattering object, techniques such as angle‐resolved low‐coherence interferometry (a/LCI) have demonstrated substantial success in identifying nuclear alterations associated with dysplasia. Because optical biopsies are inherently noninvasive, only a small, discretized portion of the 4π scattering field can be collected from tissue, limiting the amount of information available for diagnostic purposes. In this work, we comprehensively characterize the diagnostic impact of variations in angular sampling, range and noise for inverse light scattering analysis of nuclear morphology, using a previously reported dataset from 40 patients undergoing a/LCI optical biopsy for cervical dysplasia. The results from this analysis are applied to a benchtop scanning a/LCI system which compromises angular range for wide‐area scanning capability. This work will inform the design of next‐generation optical biopsy probes by directing optical design towards parameters which offer the most diagnostic utility.


  • Scanning Angle-Resolved Low Coherence Interferometry System for Clinical Detection of Cervical Dysplasia

    by Derek S. Ho, Kengyeh K. Chu, Zachary A. Steelman, Adam Wax

    We present the design of a scanning a/LCI instrument which uses the depth-resolved reflectivity profile to identify the cervical transformation zone and guide a/LCI measurements of nuclear morphology for detection of cervical dysplasia in vivo.

  • Open Access

    Scanning system for angle-resolved low-coherence interferometry

    by Zachary A. Steelman, Derek Ho, Kengyeh K. Chu, Adam Wax

    Angle-resolved low-coherence interferometry (a/LCI) detects precancer by enabling depth-resolved measurements of nuclear morphology in vivo. A significant limitation of a/LCI is the point-probe nature of the method, sampling <0.5 mm2 before probe relocation is necessary. In this work, we demonstrate a scanning method capable of assessing an area >100 mm2 without repositioning. By utilizing a reflection-only three-optic rotator prism and a two-axis scanning mirror, we demonstrate radial scans of a sample with a linear range of 12 mm and a full rotational range of 180°. Use of this design will improve the diagnostic utility of a/LCI for wide-area screening of tissue health.