DBDirk Boye

Dirk Boye

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dirk Boye has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of contour propagation and background corrections in different MRI flow software packages

    by D Boye, O Springer, F Wassmer, S Scheidegger, L Remonda, J Berberat

    Background: Velocity-encoded magnetic resonance imaging (VENC-MRI) is a commonly used technique in cardiac examinations. This technique utilizes the phase shift properties of protons moving along a magnetic field gradient. VENC-MRI offers a unique way of measuring the severity of valve regurgitation by directly quantifying the regurgitation flow volume. Purpose: To compare flow analysis results of different software programs and to assess the effect of background correction in sample patient cases. Material and Methods: A phantom was built out of Polymethyl methacrylate (PMMA) which provides tubes of different diameters. These tubes can be connected to an external water circuit to generate a water flow inside the tubes. Expected absolute flow quantities inside the tubes were determined from preset tube- and flow-parameters. Different flow conditions were measured with a VENC-MRI sequence and the images evaluated using different software packages. In a second step six randomly selected patients showing different degrees of aortic insufficiency were evaluated in clinical terms. Results: The contour propagation algorithms used in the software packages performed differently even on static phantom geometry. In terms of clinical evaluation the software packages performed similarly. Enabling background correction or leaving out manual correction of propagated contours changed results for severity of aortic insufficiency. Conclusion: Turning on background correction and manual correction of propagated contours in MRI flow volume measurements is strongly recommended.


  • Deformable motion reconstruction for scanned proton beam therapy using on-line x-ray imaging

    by Ye Zhang, A Knopf, C Tanner, D Boye, A J Lomax

    Organ motion is a major problem for any dynamic radiotherapy delivery technique, and is particularly so for spot scanned proton therapy. On the other hand, the use of narrow, magnetically deflected proton pencil beams is potentially an ideal delivery technique for tracking tumour motion on-line. At PSI, our new Gantry is equipped with a Beams Eye View (BEV) imaging system which will be able to acquire 2D x-ray images in fluoroscopy mode during treatment delivery. However, besides precisely tracking motion from BEVs, it is also essential to obtain information on the 3D motion vector throughout the whole region of interest, and any sparsely acquired surrogate motion is generally not sufficient to describe the deformable behaviour of the whole volume in three dimensions. In this study, we propose a method by which 3D deformable motions can be estimated from surrogate motions obtained using this monoscopic imaging system. The method assumes that example motions over a number of breathing cycles can be acquired before treatment for each patient using 4DMRI. In this study, for each of 11 different subjects, 100 continuous breathing cycles have been extracted from extended 4DMRI studies in the liver and then subject specific motion models have been built using principle component analysis (PCA). To simulate treatment conditions, a different set of 30 continuous breathing cycles from the same subjects have then been used to generate a set of simulated 4DCT data sets (so-called 4DCT(MRI) data sets), from which time-resolved digitally reconstructed radiographs (DRRs) were calculated using the BEV geometry for three treatment fields respectively. From these DRRs, surrogate motions from fiducial markers or the diaphragm have been used as a predictor to estimate 3D motions in the liver region for each subject. The prediction results have been directly compared to the 'ground truth' motions extracted from the same 30 breath cycles of the originating 4DMRI data set. Averaged over all 11 subjects, and for three field directions, for 99% of predicted positions, median (max) error magnitudes of better than 2.63(5.67) mm can be achieved when fiducial markers was chosen as predictor. Furthermore, three single fields, 4D dose calculations have been performed as a verification tool to evaluate the prediction performance of such a model in the context of scanned proton beam therapy. These show a high similarity between plans considering either PCA predicted motion or ground truth motion, where absolute dose differences of more than 5% (V(dosediff = 5%)) occur for the worst field scenarios in only 3.61% (median) or 15.13% (max) of dose calculation points in the irradiated volume. The magnitude of these dose differences were insignificantly dependent on whether surrogate motions were tracked by monoscopic or stereoscopic imaging systems, or whether fiducial markers or diaphragm were chosen as surrogate. This study has demonstrated that on-line deformable motion reconstruction from sparse surrogate motions is feasible, even when using only a monoscopic imaging system. In addition, it has also been found that diaphragm motion can be considered as a good predictor for respiratory deformable liver motion prediction, implying that fiducial markers might not be compulsory if used in conjunction with a patient specific PCA based model.


  • Adequate margin definition for scanned particle therapy in the incidence of intrafractional motion

    by Antje-Christin Knopf, Dirk Boye, Antony Lomax, Shininchiro Mori

    Advanced 4D dose calculations (4DDCs) for scanned particle therapy show that in the incidence of motion, it is insufficient to use target contours defined on one reference CT phase. ICRU Report 62 (ICRU 1999 ICRU Report 62 (Bethesda, MD: ICRU)) advises that variations in size, shape and position of CTVs relative to anatomic reference points have to be considered for internal target volumes (ITVs). In addition to geometrical margin adaption, changes of water equivalent path length have to be considered for particle therapy. Different ITV concepts have been applied to six representative patients (liver and lung indications) based on 4DCT. Geometrical ITVs (gITV) were calculated by combining deformed CTVs over all motion phases. To take into account path length changes, range adapted ITVs (raITV) were established as the union of range adapted CTVs in all phases. For gated delivery, gat_gITVs and gat_raITVs were calculated. Extensive 4DDCs have been performed for two exemplary patients to illustrate that neither re-scanning nor gating can sufficiently compensate for motion effects if no appropriate margins are employed and to evaluate the effectiveness of gITVs and raITVs. CTVs significantly differ from gITVs and raITVs in size (up to a factor 2 in volume). But also raITVs and gITVs differ significantly in size and are spatially displaced, particularly for lung patients. raITVs show a strong field dependence in shape. All volumes are reduced in size when gating is applied and considered during margin adaption. 4D dose distributions show big improvements when gITV or raITV are used compared to CTVs. However, the use of either gITVs or raITVs do not result in significant differences. If raITVs are used, slightly better target coverage is gained at the cost of more healthy tissue exposure. Our results emphasize that adapted target volumes have to be used for scanned particle therapy in the presence of motion. However, even though gITVs and raITVs differ significantly in shape and size, this difference does not necessarily translate into significant differences in the resultant 4D dose distributions.


  • Mapping motion from 4D‐MRI to 3D‐CT for use in 4D dose calculations: A technical feasibility study

    by Dirk Boye, Tony Lomax, Antje Knopf

    Purpose: Target sites affected by organ motion require a time resolved (4D) dose calculation. Typical 4D dose calculations use 4D‐CT as a basis. Unfortunately, 4D‐CT images have the disadvantage of being a “snap‐shot” of the motion during acquisition and of assuming regularity of breathing. In addition, 4D‐CT acquisitions involve a substantial additional dose burden to the patient making many, repeated 4D‐CT acquisitions undesirable. Here the authors test the feasibility of an alternative approach to generate patient specific 4D‐CT data sets.Methods: In this approach motion information is extracted from 4D‐MRI. Simulated 4D‐CT data sets [which the authors call 4D‐CT(MRI)] are created by warping extracted deformation fields to a static 3D‐CT data set. The employment of 4D‐MRI sequences for this has the advantage that no assumptions on breathing regularity are made, irregularities in breathing can be studied and, if necessary, many repeat imaging studies (and consequently simulated 4D‐CT data sets) can be performed on patients and/or volunteers. The accuracy of 4D‐CT(MRI)s has been validated by 4D proton dose calculations. Our 4D dose algorithm takes into account displacements as well as deformations on the originating 4D‐CT/4D‐CT(MRI) by calculating the dose of each pencil beam based on an individual time stamp of when that pencil beam is applied. According to corresponding displacement and density‐variation‐maps the position and the water equivalent range of the dose grid points is adjusted at each time instance.Results: 4D dose distributions, using 4D‐CT(MRI) data sets as input were compared to results based on a reference conventional 4D‐CT data set capturing similar motion characteristics. Almost identical 4D dose distributions could be achieved, even though scanned proton beams are very sensitive to small differences in the patient geometry. In addition, 4D dose calculations have been performed on the same patient, but using 4D‐CT(MRI) data sets based on variable breathing patterns to show the effect of possible irregular breathing on active scanned proton therapy. Using a 4D‐CT(MRI), including motion irregularities, resulted in significantly different proton dose distributions.Conclusions: The authors have demonstrated that motion information from 4D‐MRI can be used to generate realistic 4D‐CT data sets on the basis of a single static 3D‐CT data set. 4D‐CT(MRI) presents a novel approach to test the robustness of treatment plans in the circumstance of patient motion.


  • Population based modeling of respiratory lung motion and prediction from partial information

    by Dirk Boye, Golnoosh Samei, Johannes Schmidt, Gabor Székely, Christine Tanner


  • Respiratory liver motion estimation and its effect on scanned proton beam therapy

    by Ye Zhang, D Boye, C Tanner, A J Lomax, A Knopf

    Proton therapy with active scanning beam delivery has significant advantages compared to conventional radiotherapy. However, so far only static targets have been treated in this way, since moving targets potentially lead to interplay effects. For 4D treatment planning, information on the target motion is needed to calculate time-resolved dose distributions. In this study, respiratory liver motion has been extracted from 4D CT data using two deformable image registration algorithms. In moderately moving patient cases (mean motion range around 6 mm), the registration error was no more than 3 mm, while it reached 7 mm for larger motions (range around 13 mm). The obtained deformation fields have then been used to calculate different time-resolved 4D treatment plans. Averaged over both motion estimations, interplay effects can increase the D₅-D₉₅ value for the clinical target volume (CTV) from 8.8% in a static plan to 23.4% when motion is considered. It has also been found that the different deformable registration algorithms can provide different motion estimations despite performing similarly for the selected landmarks, which in turn can lead to differing 4D dose distributions. Especially for single-field treatments where no motion mitigation is used, a maximum (mean) dose difference (averaged over three cases) of 32.8% (2.9%) can be observed. However, this registration ambiguity-induced uncertainty can be reduced if rescanning is applied or if the treatment plan consists of multiple fields, where the maximum (mean) difference can decrease to 15.2% (0.57%). Our results indicate the necessity to interpret 4D dose distributions for scanned proton therapy with some caution or with error bars to reflect the uncertainties resulting from the motion estimation. On the other hand, rescanning has been found to be an appropriate motion mitigation technique and, furthermore, has been shown to be a robust approach to also deal with these motion estimation uncertainties.


  • Review on 4D Models for Organ Motion Compensation

    by Christine Tanner, Dirk Boye, Golnoosh Samei, Gabor Szekely

    Minimal invasive tumor therapies are getting ever more sophisticated with novel treatment approaches and new devices allowing for improved targeting precision. Applying these effectively requires precise localization of the structures of interest. Vital processes, such as respiration and heartbeat, induce organ motion, which cannot be neglected during therapy. This review focuses on 4D organ models to compensate for respiratory motion during therapy. An overview is given on the effects of motion on the therapeutical outcome, methods required to capture and quantify respiratory motion, range of reported tumor motion, types of surrogates used when tumors are not directly observable, and methods for temporal prediction of surrogate motion. Organ motion models, which predict the location of structures of interest from surrogates measured during therapy, are discussed in detail.


  • Special report: Workshop on 4D‐treatment planning in actively scanned particle therapy—Recommendations, technical challenges, and future research directions

    by Antje Knopf, Christoph Bert, Emily Heath, Simeon Nill, Kim Kraus, Daniel Richter, Eugen Hug, Eros Pedroni, Sairos Safai, Francesca Albertini, et al.

    This article reports on a 4D‐treatment planning workshop (4DTPW), held on 7–8 December 2009 at the Paul Scherrer Institut (PSI) in Villigen, Switzerland. The participants were all members of institutions actively involved in particle therapy delivery and research. The purpose of the 4DTPW was to discuss current approaches, challenges, and future research directions in 4D‐treatment planning in the context of actively scanned particle radiotherapy. Key aspects were addressed in plenary sessions, in which leaders of the field summarized the state‐of‐the‐art. Each plenary session was followed by an extensive discussion. As a result, this article presents a summary of recommendations for the treatment of mobile targets (intrafractional changes) with actively scanned particles and a list of requirements to elaborate and apply these guidelines clinically.


  • Epitaxial lead-chalcogenides on Si and BaF 2 for mid-IR detectors and emitters including cavities

    by H Zogg, Mark A Arnold, Ferdinand Felder, Munirah Sufiyah Abdul Rahim, M Fill, D Boye

    We describe two new optoelectronic mid-IR devices employing narrow gap lead-chalcogenide (IV-VI) layers on Si or BaF2 substrates: (1) Tunable resonant cavity enhanced detectors (RCED) for the mid-infrared with an epitaxial Bragg mirror and a thin p-n+ heterojunction as detecting layer have been realized for the first time. They are tunable by moving the top micro-electro-mechanical micromirror, thus changing the cavity length. (2) Optically pumped vertical external cavity surface emitting lasers (VECSEL) with an emission wavelength above 5 μm were fabricated, for the first time, too. Presently they operate with an output power of up to 260 mWp and up to 175 K. With improved appropriate precautions for efficient heat removal, still much higher operation temperatures are expected. Both resonant cavity enhanced devices may be used as miniature infrared spectrometers to cover the spectral range from < 3 μm up to > 20 μm.