CMChristopher Morris

Christopher Morris

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christopher Morris has a total of 52 co-authors. Here are the top co-authors by number of shared publications:

  • A Clements

    Department of Clinical Perfusion Science, Essex Cardiothoracic Centre, Basildon, Essex, UK

    1 shared publication
  • Amanda Kirkham

    Cancer Research UK Clinical Trials Unit, University of Birmingham, Birmingham, UK

    1 shared publication
  • Andrea Schlegel

    Centre for Liver and Gastrointestinal Research, Institute of Immunology and Immunotherapy, University of Birmingham, Birmingham, UK

    1 shared publication
  • Andris Jankevics

    Phenome Centre Birmingham, School of Biosciences, University of Birmingham, Birmingham, UK

    1 shared publication
  • Ann Clements

    Department of Clinical Perfusion Science, Essex Cardiothoracic Centre, UK, Department of Clinical Perfusion Research, Imperial College Health Science Centre, London, UK

    1 shared publication
  • C. J. Allegra

    1 shared publication

Latest Publications

  • Open Access

    Molecular fingerprints linked to graft viability in extended criteria donor livers during normothermic machine perfusion

    by Joseph A. Attard, Richard Laing, Lorraine Wallace, Lukas Najdekr, Gavin R. Lloyd, Andris Jankevics, Amanda Kirkham, Yuri L. Boteon, Darren Barton, Stuart Curbishley, et al.

    Background: Donor organ shortage has led to increased reliance on extended-criteria donor (ECD) livers for transplantation. Normothermic machine perfusion (NMP) has led to a paradigm shift in organ preservation from cold storage to full ex-situ metabolic support. This study investigated ECD liver metabolic profiling to elucidate NMP molecular signatures and whether signatures were predictive of graft viability and clinical outcome. Methods: Thirty-one livers underwent NMP for a minimum of four hours and 23 livers fulfilled NMP viability criteria. Perfusate from graft perfusion commencement to 4-h time point were collected at 0.25, 2 and 4 h. Samples underwent untargeted metabolomics analysis using Ultra High Performance Liquid Chromatography-Mass Spectrometry. Univariate statistical analyses revealed dynamic changes in metabolic profiles across the perfusion period and differences in water-soluble and lipid-based metabolites between viable and non-viable livers. Results: Pathway enrichment analysis highlights pathways relating to amino acid and energy metabolism differing between viable and non-viable livers. Metabolic changes are not observed for ECD livers based on post-transplant clinical outcome. Conclusions: This study revealed metabolic signatures of ECD livers that may define metabolic differences related to graft viability which can be targeted for improved viability.

  • Fiber-optic intra-aortic balloon therapy and its role within cardiac surgery

    by G Yarham, A Clements, C Morris, T Cumberland, M Bryan, M Oliver, H Burrows, J Mulholland

    Introduction: The patient population has changed and the cardiothoracic team are now operating on patients with more co-morbidity. One of the significant aspects of this increased co-morbidity, which affects both short- and long-term outcomes, is compromised left ventricular function. Intra-aortic balloon pump (IABP) technology offers these patients and the cardiac team an easily accessible, cost-effective, mechanical assist device. Arterial pressure monitoring for IABP therapy: Fluid-filled transducers used to measure the aortic waveform can be unreliable and inconsistent. Fiber-optic manometers located in the very tip of the IAB catheters provide accurate and fast, high quality measurements. This, in turn, presents the opportunity for the hardware and algorithm to measure key markers on the arterial waveform and optimise left ventricular support. It also provides the potential for automatic in vivo calibration, further increasing the accuracy and quality of the IAB support. The effect of fiber-optic IABP therapy on clinical management: A dual centre prospective audit comparing fluid-filled versus fiber-optic arterial pressure monitoring showed a 96% reduction in IAB-related perfusion on-site call-outs (17 vs. 1, respectively) and a 94% reduction in sub-optimal timing (55/98 vs. 2/94, respectively). Conclusion: The improved timing algorithms utilise the pressure information received 50 msecs faster than with fluid-filled transducers, measuring key markers on the pressure waveform and adjusting inflation and deflation accurately on a beat per beat basis. Fiber-optic IAB technology and, specifically, these improved algorithms provide better beat per beat mechanical support. Given our evolving patient population, this technology will not only play an increased role, but will have a significant impact on cardiac surgery.


  • Clinical factors and outcomes in HPV-associated anal canal cancer.

    by J. Nair, Y. Hu, W. M. Mendenhall, C. Liu, C. G. Morris, R. Zlotecki, J. Kirwan, L. H. Dang, S. Tan, E. Huang, et al.

    4105 Background: HPV infection is a favorable prognostic factor in H&N squamous cell carcinomas. Some anal squamous cell carcinomas (ASCCA) are associated with HPV infection with limited data linking HPV status with other clinical risk factors or prognosis in ASCCA. Methods: Patients with non-metastatic ASCCA treated between 1979-2010 at the University of Florida were eligible. Risk factors, tumor characteristics and clinical outcomes were identified. Formalin Fixed Paraffin Embedded (FFPE) tissue samples were obtained and analyzed for Ki67%, p16 overexpression (p16ink+) and concurrent active high-risk HPV infection(HPV-ISH +/-). HPV status was correlated with clinicopathologic factors using descriptive statistics, contingency analysis and chi-squared tests. Results: 125 patients were eligible and included in the analysis. All patients received definitive radiotherapy (median 59Gy) with concurrent chemotherapy in 74%. 5 year PFS was 74%, OS was 81% with a 9% colostomy rate. Impact of known clinical risk factors is consistent with previous reports. 36 patients had FFPE available for analysis. All overexpressed p16ink with 23 (64%) demonstrating concurrent HPV-ISH +. Characteristics of the total patient group, FFPE available group, and HPV-ISH cohorts are in the table. Median follow-up of p16ink positive cases was 57 months. HPV-ISH + patients had higher incidence of N+ disease, history of condyloma, and less tobacco use. At 3 years, there were no significant differences in PFS (68 vs.73%;p=NS) or OS (90 vs 61%;p=NS) for HPV-ISH + patients. Conclusions: P16 overexpression was present in all samples analyzed. Concurrent active HPV infection may be associated with condyloma and N+ disease, but does not appear to impact PFS or OS in ASCCA. The prognostic impact of HPV infection in ASCCA may be limited. The p16 pathway may be a novel therapeutic target in ASCCA.

  • Evaluating the ‘next generation’ of cell salvage - will it make a difference?

    by Gemma Yarham, Ann Clements, Martin Oliver, Christopher Morris, Tom Cumberland, Megan Bryan, Sasa Jekler, Kathy Johns, John Mulholland

    Introduction: Donor blood supplies are diminishing, becoming more costly and these transfusions lead to higher mortality in cardiac patients. The transfusion risks and the literature highlight the need for an alternative similar to cell salvage to be routinely considered. The Xtra is the first cell saver to be launched since 2001 and will undoubtedly initiate evolution towards the ‘next generation’ of cell savers. It is also the first to be launched in a new era where the demand for electronic perfusion data management (EPDM) has grown. Results: The user interface (UI) was easy to use. The increased data entry options improved the quality of the recordable data. The integrated data management system (DMS) was comprehensive. Data was easy to manage and enabled central data compilation, which reduces repeated data, the risk of inconsistent data inventory and provides the potential for research and analyses. The haematocrit of the processed blood is a key quality indicator for cell salvage. The comparison of the manufacturer’s integrated protocol, Popt, to our team’s own protocol showed that Popt delivered a higher haematocrit on its ‘1st bowl’ (59.1% compared to 57.3%) and its ‘total process’ end product haematocrit was 0.68% higher. The Popt cycle took an average of 330s, whereas our own settings completed in just over 300s. Conclusion: The Xtra is a device which will lead the evolution of ‘next generation’ cell saver technology. The user interface and data management system provide export options and the ability to record the level of data required for good EPDM. This is essential to ‘future proof’ cell salvage technology. The manufacturer’s integrated protocol achieved a higher end product haematocrit than our perfusion team’s best practice. The design of the Xtra is contemporary, but the DMS equips this cell saver for the new era that faces both Perfusion and Cardiac Surgery.