Andrei Damyanovich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andrei Damyanovich has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
J. Peternelj
Faculty of Civil and Geodetic Engineering, University of Ljubljana, Institute J. Stefan, Ljubljana, Slovenia
6 shared publicationsM. M. Pintar
Department of Physics, University of Waterloo, Ontario N2L 3G1, Canada
5 shared publications- David Anthony Jaffray
The University of Texas MD Anderson Cancer Center, Houston, TX
3 shared publications M.M. Pintar
Department of Physics, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
3 shared publicationsAnna Kirilova
Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Canada
2 shared publicationsC. Choi
Department of Physics, University of Waterloo, Ontario N2L 3G1, Canada
2 shared publications
Latest Publications
- 3 May 2023
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 31 (8) , 1066-1077
1H NMR metabolic profiling of synovial fluid from patients with anterior cruciate ligament tears and hemarthrosis
- 3 May 2023
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 31 (8) , 1066-1077
1H NMR metabolic profiling of synovial fluid from patients with anterior cruciate ligament tears and hemarthrosis
- 27 March 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (7) , 075010
Design and implementation of a 3D-MR/CT geometric image distortion phantom/analysis system for stereotactic radiosurgery
The design, construction and application of a multimodality, 3D magnetic resonance/computed tomography (MR/CT) image distortion phantom and analysis system for stereotactic radiosurgery (SRS) is presented. The phantom is characterized by (1) a 1 × 1 × 1 (cm) 3 MRI/CT-visible 3D-Cartesian grid; (2) 2002 grid vertices that are 3D-intersections of MR-/CT-visible ‘lines’ in all three orthogonal planes; (3) a 3D-grid that is MR-signal positive/CT-signal negative; (4) a vertex distribution sufficiently ‘dense’ to characterize geometrical parameters properly, and (5) a grid/vertex resolution consistent with SRS localization accuracy. When positioned correctly, successive 3D-vertex planes along any orthogonal axis of the phantom appear as 1 × 1 (cm) 2 -2D grids, whereas between vertex planes, images are defined by 1 × 1 (cm) 2 -2D arrays of signal points. Image distortion is evaluated using a centroid algorithm that automatically identifies the center of each 3D-intersection and then calculates the deviations d x , d y , d z and d r for each vertex point; the results are presented as a color-coded 2D or 3D distribution of deviations. The phantom components and 3D-grid are machined to sub-millimeter accuracy, making the device uniquely suited to SRS applications; as such, we present it here in a form adapted for use with a Leksell stereotactic frame. Imaging reproducibility was assessed via repeated phantom imaging across ten back-to-back scans; 80%–90% of the differences in vertex deviations d x , d y , d z and d r between successive 3 T MRI scans were found to be ⩽0.05 mm for both axial and coronal acquisitions, and over >95% of the differences were observed to be ⩽0.05 mm for repeated CT scans, clearly demonstrating excellent reproducibility. Applications of the 3D-phantom/analysis system are presented, using a 32-month time-course assessment of image distortion/gradient stability and statistical control chart for 1.5 T and 3 T GE Twin Speed MRI systems.
- 27 March 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (7) , 075010
Design and implementation of a 3D-MR/CT geometric image distortion phantom/analysis system for stereotactic radiosurgery
The design, construction and application of a multimodality, 3D magnetic resonance/computed tomography (MR/CT) image distortion phantom and analysis system for stereotactic radiosurgery (SRS) is presented. The phantom is characterized by (1) a 1 × 1 × 1 (cm) 3 MRI/CT-visible 3D-Cartesian grid; (2) 2002 grid vertices that are 3D-intersections of MR-/CT-visible ‘lines’ in all three orthogonal planes; (3) a 3D-grid that is MR-signal positive/CT-signal negative; (4) a vertex distribution sufficiently ‘dense’ to characterize geometrical parameters properly, and (5) a grid/vertex resolution consistent with SRS localization accuracy. When positioned correctly, successive 3D-vertex planes along any orthogonal axis of the phantom appear as 1 × 1 (cm) 2 -2D grids, whereas between vertex planes, images are defined by 1 × 1 (cm) 2 -2D arrays of signal points. Image distortion is evaluated using a centroid algorithm that automatically identifies the center of each 3D-intersection and then calculates the deviations d x , d y , d z and d r for each vertex point; the results are presented as a color-coded 2D or 3D distribution of deviations. The phantom components and 3D-grid are machined to sub-millimeter accuracy, making the device uniquely suited to SRS applications; as such, we present it here in a form adapted for use with a Leksell stereotactic frame. Imaging reproducibility was assessed via repeated phantom imaging across ten back-to-back scans; 80%–90% of the differences in vertex deviations d x , d y , d z and d r between successive 3 T MRI scans were found to be ⩽0.05 mm for both axial and coronal acquisitions, and over >95% of the differences were observed to be ⩽0.05 mm for repeated CT scans, clearly demonstrating excellent reproducibility. Applications of the 3D-phantom/analysis system are presented, using a 32-month time-course assessment of image distortion/gradient stability and statistical control chart for 1.5 T and 3 T GE Twin Speed MRI systems.
- 25 May 2011
- Published by Wiley in Liver International
- Vol. 31 (7) , 1028-1038
Influence of hepatitis C virus on neurocognitive function in patients free from other risk factors: validation from therapeutic outcomes
Mild neurocognitive dysfunction and altered cerebral proton magnetic resonance spectroscopy ((1) H-MRS) have been demonstrated in patients with chronic hepatitis C (CHC). This longitudinal study aimed to quantify these abnormalities in a cohort of patients free from correlated risk factors and determine whether treatment-induced viral clearance abolished these abnormalities. Treatment-naïve, non-cirrhotic patients with CHC, rigorously screened and excluded for other causes of impaired neurocognition, underwent neurocognitive testing, (1) H-MRS and evaluation for quality of life (QOL), mood and fatigue, before and 6 months after the completion of antiviral therapy. A comparison group of healthy controls was similarly assessed at baseline and 1 year later. Post-treatment results in 40 patients with CHC [31 sustained virological responders, hepatitis C virus (HCV)-R and 9 non-responders, HCV-NR] were compared with their pretreatment results, and with the baseline and follow-up assessments of 39 healthy controls. Before receiving treatment, patients had impaired learning efficiency, poorer QOL and higher fatigue scores compared with the controls. Viral clearance was associated with a significant albeit small improvement in the QOL score that did not reach control levels. Cerebral (1) H-MRS demonstrated a lower N-acetyl aspartate/creatine (CRE) ratio in the globus pallidus (GP) of patients with hepatitis C, which was unchanged with viral clearance. The GP choline/CRE ratio increased in HCV-R following treatment, without a correlation with cognitive measures. The hepatitis C virus has a measurable effect on CNS integrity in patients screened for other medical and/or psychiatric comorbidities. Viral clearance has not been demonstrated to abolish these abnormalities.
- 25 May 2011
- Published by Wiley in Liver International
- Vol. 31 (7) , 1028-1038
Influence of hepatitis C virus on neurocognitive function in patients free from other risk factors: validation from therapeutic outcomes
Mild neurocognitive dysfunction and altered cerebral proton magnetic resonance spectroscopy ((1) H-MRS) have been demonstrated in patients with chronic hepatitis C (CHC). This longitudinal study aimed to quantify these abnormalities in a cohort of patients free from correlated risk factors and determine whether treatment-induced viral clearance abolished these abnormalities. Treatment-naïve, non-cirrhotic patients with CHC, rigorously screened and excluded for other causes of impaired neurocognition, underwent neurocognitive testing, (1) H-MRS and evaluation for quality of life (QOL), mood and fatigue, before and 6 months after the completion of antiviral therapy. A comparison group of healthy controls was similarly assessed at baseline and 1 year later. Post-treatment results in 40 patients with CHC [31 sustained virological responders, hepatitis C virus (HCV)-R and 9 non-responders, HCV-NR] were compared with their pretreatment results, and with the baseline and follow-up assessments of 39 healthy controls. Before receiving treatment, patients had impaired learning efficiency, poorer QOL and higher fatigue scores compared with the controls. Viral clearance was associated with a significant albeit small improvement in the QOL score that did not reach control levels. Cerebral (1) H-MRS demonstrated a lower N-acetyl aspartate/creatine (CRE) ratio in the globus pallidus (GP) of patients with hepatitis C, which was unchanged with viral clearance. The GP choline/CRE ratio increased in HCV-R following treatment, without a correlation with cognitive measures. The hepatitis C virus has a measurable effect on CNS integrity in patients screened for other medical and/or psychiatric comorbidities. Viral clearance has not been demonstrated to abolish these abnormalities.
- 1 February 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 79 (2) , 371-378
3D MR-Spectroscopic Imaging Assessment of Metabolic Activity in the Prostate During the PSA “Bounce” Following 125Iodine Brachytherapy
- 1 February 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 79 (2) , 371-378
3D MR-Spectroscopic Imaging Assessment of Metabolic Activity in the Prostate During the PSA “Bounce” Following 125Iodine Brachytherapy
- 20 October 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (22) , 6601-6615
Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ≤ 0.6 mm; standard deviation ≤ 0.3 mm). Mean stereotactic reference deviations between phantoms and patients correlated well (T1: R = 0.79; T2: R = 0.84). Statistical process control analysis on phantom QA data demonstrated the stability of our SRS imaging protocols, where the geometric accuracy of the 3 T SRS imaging protocol is operating within the appropriate tolerance. Our data provide evidence supporting the spatial validity of 3 T MRI for targeting SRS under imaging conditions investigated. We have developed a systematic approach to achieve confidence on the geometric integrity of a given imaging system/technique for clinical integration in SRS application.
- 20 October 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (22) , 6601-6615
Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ≤ 0.6 mm; standard deviation ≤ 0.3 mm). Mean stereotactic reference deviations between phantoms and patients correlated well (T1: R = 0.79; T2: R = 0.84). Statistical process control analysis on phantom QA data demonstrated the stability of our SRS imaging protocols, where the geometric accuracy of the 3 T SRS imaging protocol is operating within the appropriate tolerance. Our data provide evidence supporting the spatial validity of 3 T MRI for targeting SRS under imaging conditions investigated. We have developed a systematic approach to achieve confidence on the geometric integrity of a given imaging system/technique for clinical integration in SRS application.
- Open Access
- 26 September 2007
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 58 (4) , 666-673
Assessment of metabolite quantitation reproducibility in serial 3D‐1H‐MR spectroscopic imaging of human brain using stereotactic repositioning
Intrasubject reproducibility of metabolite quantitation in three‐dimensional proton magnetic resonance spectroscopic imaging (3D‐MRSI) was investigated in 10 healthy volunteers over five separate sessions using two echo times (TEs): 144 and 30 ms. The use of a Gill‐Thomas‐Cosman (GTC) stereotactic head frame enabled precise subject repositioning and immobilization. Metabolite levels from each voxel in the volume of interest (VOI) were quantified using the Linear Combination of Model spectra (LCModel) analysis algorithm, and coefficients of variation (CVs) were calculated. Standard error estimates (%SD or Cramer‐Rao lower bounds) generated by LCModel were used as a confidence filter. The 95% confidence interval (CI) was found for each metabolite, providing an indication of the normal fluctuation expected for 3D‐MRSI. In vivo, median CVs at the %SD ≤ 20 level were found to be (%CV for TE = 144 and 30 ms, respectively): N‐acetyl‐aspartate plus N‐acetyl‐aspartyl‐glutamate (NAA): 10.2% and 13.5%; creatine plus phosphocreatine (Cr), 14.4% and 21.7%; and choline‐containing compounds (Cho), 15.2% and 18.4%. Relaxing the statistical filtering criteria to %SD ≤ 30 increased median CVs by less than 5% and permitted in vivo quantitation reproducibility to be evaluated for glutamine plus glutamate (Glx) and myoinositol (Ins) for TE = 30 ms, yielding CVs of 24.0% and 21.0%, respectively. Magn Reson Med 58:666–673, 2007.
- 26 September 2007
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 58 (4) , 666-673
Open AccessAssessment of metabolite quantitation reproducibility in serial 3D‐1H‐MR spectroscopic imaging of human brain using stereotactic repositioning
Intrasubject reproducibility of metabolite quantitation in three‐dimensional proton magnetic resonance spectroscopic imaging (3D‐MRSI) was investigated in 10 healthy volunteers over five separate sessions using two echo times (TEs): 144 and 30 ms. The use of a Gill‐Thomas‐Cosman (GTC) stereotactic head frame enabled precise subject repositioning and immobilization. Metabolite levels from each voxel in the volume of interest (VOI) were quantified using the Linear Combination of Model spectra (LCModel) analysis algorithm, and coefficients of variation (CVs) were calculated. Standard error estimates (%SD or Cramer‐Rao lower bounds) generated by LCModel were used as a confidence filter. The 95% confidence interval (CI) was found for each metabolite, providing an indication of the normal fluctuation expected for 3D‐MRSI. In vivo, median CVs at the %SD ≤ 20 level were found to be (%CV for TE = 144 and 30 ms, respectively): N‐acetyl‐aspartate plus N‐acetyl‐aspartyl‐glutamate (NAA): 10.2% and 13.5%; creatine plus phosphocreatine (Cr), 14.4% and 21.7%; and choline‐containing compounds (Cho), 15.2% and 18.4%. Relaxing the statistical filtering criteria to %SD ≤ 30 increased median CVs by less than 5% and permitted in vivo quantitation reproducibility to be evaluated for glutamine plus glutamate (Glx) and myoinositol (Ins) for TE = 30 ms, yielding CVs of 24.0% and 21.0%, respectively. Magn Reson Med 58:666–673, 2007.
- 1 May 2006
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 77 (5) , 054301
NMR high-resolution magic angle spinning rotor design for quantification of metabolic concentrations
A new high-resolution magic angle spinning nuclear magnetic resonance technique is presented to obtain absolute metabolite concentrations of solutions. The magnetic resonance spectrum of the sample under investigation and an internal reference are acquired simultaneously, ensuring both spectra are obtained under the same experimental conditions. The robustness of the technique is demonstrated using a solution of creatine, and it is shown that the technique can obtain solution concentrations to within 7% or better.
- 1 May 2006
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 77 (5) , 054301
NMR high-resolution magic angle spinning rotor design for quantification of metabolic concentrations
A new high-resolution magic angle spinning nuclear magnetic resonance technique is presented to obtain absolute metabolite concentrations of solutions. The magnetic resonance spectrum of the sample under investigation and an internal reference are acquired simultaneously, ensuring both spectra are obtained under the same experimental conditions. The robustness of the technique is demonstrated using a solution of creatine, and it is shown that the technique can obtain solution concentrations to within 7% or better.
- 1 November 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (6) , 1397-1402
Characterization of proteoglycan depletion in articular cartilage using two‐dimensional time domain nuclear magnetic resonance
In vitro proteoglycan (PG) depletion in the 20–40% range (enzymatic PG depletion of normal cartilage in the early osteoarthritis (OA) PG depletion range) was investigated in articular cartilage using 2D time domain NMR relaxation techniques. Spin–lattice relaxation times were measured at low fields (T1ρ) and at high fields (T1) using nonselective and selective excitation pulse sequences. The short relaxation time magnetization components in T1ρ (∼8% signal) and nonselective T1 (∼5% signal) experiments were significantly altered with PG degradation. In addition, a magnetization component (∼5% signal) with a “fast ” T1 ∼ 7 ms was observed in the T1 experiment involving selective excitation. This fast T1 was at least 10 times shorter than the short T1 in the nonselective experiment and was associated with a strong magnetization exchange mechanism between collagen and PG. The results suggest that T1ρ and T1 (nonselective and selective) relaxation based MRI techniques, which focus on the short relaxation time magnetization components, have the potential of detecting molecular abnormalities associated with early OA earlier than single, long relaxation time component approaches. Magn Reson Med, 2005.
- 1 November 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (6) , 1397-1402
Characterization of proteoglycan depletion in articular cartilage using two‐dimensional time domain nuclear magnetic resonance
In vitro proteoglycan (PG) depletion in the 20–40% range (enzymatic PG depletion of normal cartilage in the early osteoarthritis (OA) PG depletion range) was investigated in articular cartilage using 2D time domain NMR relaxation techniques. Spin–lattice relaxation times were measured at low fields (T1ρ) and at high fields (T1) using nonselective and selective excitation pulse sequences. The short relaxation time magnetization components in T1ρ (∼8% signal) and nonselective T1 (∼5% signal) experiments were significantly altered with PG degradation. In addition, a magnetization component (∼5% signal) with a “fast ” T1 ∼ 7 ms was observed in the T1 experiment involving selective excitation. This fast T1 was at least 10 times shorter than the short T1 in the nonselective experiment and was associated with a strong magnetization exchange mechanism between collagen and PG. The results suggest that T1ρ and T1 (nonselective and selective) relaxation based MRI techniques, which focus on the short relaxation time magnetization components, have the potential of detecting molecular abnormalities associated with early OA earlier than single, long relaxation time component approaches. Magn Reson Med, 2005.
- Open Access
- 25 March 2005
- Published by Wolters Kluwer Health in Hepatology
- Vol. 41 (4) , 801-808
Prevalence and significance of neurocognitive dysfunction in hepatitis C in the absence of correlated risk factors†
Neurocognitive morbidity has been reported in individuals with chronic hepatitis C virus (HCV) infection, but the magnitude of such dysfunction in the absence of disease-correlated factors known to affect the central nervous system (e.g., substance abuse, cirrhosis, depression, interferon treatment) and the impact of any such change on functioning is unclear. We investigated a cohort of individuals with HCV, all of whom were carefully screened to exclude relevant comorbidities, to elucidate virus-related changes in the brain using neuropsychological tests and magnetic resonance spectroscopy (MRS). A cohort of 37 patients with chronic HCV infection was culled from 300 consecutive patients presenting to a tertiary care liver clinic. A comparison group of healthy controls (n = 46) was also assessed. Of 10 neurocognitive measures evaluated, the HCV group showed marginally poorer learning efficiency compared with controls; only 13% of patients demonstrated a clinical level of impairment on this test (defined as 1.5 SD below the normative standard). Although patients reported greater levels of fatigue and symptoms of depression, these factors did not correlate with the degree of learning inefficiency. With respect to MRS, the HCV group demonstrated increased choline and reduced N-acetyl aspartate relative to controls in the central white matter. Indicators of liver disease severity did not correlate with either memory or MRS abnormalities. In conclusion, while our findings support an association between hepatitis C and indicators of central nervous system involvement in a cohort of patients carefully screened to eliminate other factors influencing neurocognitive integrity, the clinical significance of these effects is limited. (HEPATOLOGY 2005;41:801–808.)
- 25 March 2005
- Published by Wolters Kluwer Health in Hepatology
- Vol. 41 (4) , 801-808
Open AccessPrevalence and significance of neurocognitive dysfunction in hepatitis C in the absence of correlated risk factors†
Neurocognitive morbidity has been reported in individuals with chronic hepatitis C virus (HCV) infection, but the magnitude of such dysfunction in the absence of disease-correlated factors known to affect the central nervous system (e.g., substance abuse, cirrhosis, depression, interferon treatment) and the impact of any such change on functioning is unclear. We investigated a cohort of individuals with HCV, all of whom were carefully screened to exclude relevant comorbidities, to elucidate virus-related changes in the brain using neuropsychological tests and magnetic resonance spectroscopy (MRS). A cohort of 37 patients with chronic HCV infection was culled from 300 consecutive patients presenting to a tertiary care liver clinic. A comparison group of healthy controls (n = 46) was also assessed. Of 10 neurocognitive measures evaluated, the HCV group showed marginally poorer learning efficiency compared with controls; only 13% of patients demonstrated a clinical level of impairment on this test (defined as 1.5 SD below the normative standard). Although patients reported greater levels of fatigue and symptoms of depression, these factors did not correlate with the degree of learning inefficiency. With respect to MRS, the HCV group demonstrated increased choline and reduced N-acetyl aspartate relative to controls in the central white matter. Indicators of liver disease severity did not correlate with either memory or MRS abnormalities. In conclusion, while our findings support an association between hepatitis C and indicators of central nervous system involvement in a cohort of patients carefully screened to eliminate other factors influencing neurocognitive integrity, the clinical significance of these effects is limited. (HEPATOLOGY 2005;41:801–808.)
- 1 February 2003
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 66 (2) , 217-224
Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration.
- 1 February 2003
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 66 (2) , 217-224
Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration.