SASurour Alaraifi

Surour Alaraifi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Surour Alaraifi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-Order Synchronized Virtual Oscillators for Resilient Control Framework and Robust Grid Integration

    by Hoach The Nguyen, Ameena Saad Al-Sumaiti, Khalifa Al-Hosani, Surour Alaraifi, Ahmed Al-Durra, Mohamed Shawky El Moursi

  • Domain of Stability Characterization for Power Systems: A Novel Individual Invariance Method

    by Surour Alaraifi, Seddik Djouadi, Mohamed Shawky El Moursi

    In this paper, we approach the problem of stability in nonlinear systems through a new perspective that views them as a combination of individual artificial systems carefully chosen to simplify the complex structure of nonlinear systems. This is achieved by recasting nonlinear vector fields as an algebraic sum of individual vector fields for which artificial systems with known invariant sets or at least in forms that allow for tractable approximation of their invariant sets. This attempt to restructure nonlinear systems stands out in comparison to other previous attempts like Lure' systems or network based models as a purely mathematical structuring technique that transcends the physical constraints and dependencies within dynamical models and allows the user to creatively construct artificial systems with the sole focus on the overall stability. The theoretical foundation is provided for a theorem about individual invariance to relate the invariant sets of individual artificial systems to the invariant set of their original system in a way that significantly simplifies the task of approximating regions of attraction. Several examples are used to demonstrate this theorem and we also evaluate the use this theorem for the challenging power system stability problems in both AC and DC grids. The proposed method is successfully applied to the IEEE 39- bus New England system, and a DC converter with constant power load giving accurate and realistic estimations of the critical clearing time and stability regions in comparison to state of the art approaches.


  • Individual Functions Method for Power System Transient Stability Assessment

    by Surour Mohamed Al Araifi, Mohamed Shawky El Moursi, Seddik M. Djouadi

    This paper introduces an alternative description of autonomous dynamical systems as a sum of individual vector fields. This structure of a dynamical system gives us the opportunity to construct individual Lyapunov-like functions to certify stability of an equilibrium point. A theorem on individual functions is developed in a quadratic form to maintain computational efficiency. As a corollary to the developed theory, we conclude that regions of attraction can be estimated by sub-level sets of individual quadratic functions, and through geometric programs they can easily be maximized efficiently. Theoretical findings in this paper are examined on transient stability problem in power systems for both single machine to infinite bus and multi-machine systems with promising results for critical clearing time estimation compared to the values obtained from time domain simulations.


  • Open Access

    Design considerations of superconducting fault current limiters for power system stability enhancement

    by Surour Alaraifi, Mohamed Shawky El Moursi

    This study identifies the type and size of the optimal shunt limiting impedance for superconducting fault current limiter (SFCL). Since the shunt impedance has been widely categorised to be either inductive or resistive element depending on the type of limiting impedance, the proposed design considerations will significantly affect the transient response and system stability. Therefore, the presented problem formulation optimises the design of SFCL by allowing the limiting shunt impedance to combine both resistive and inductive elements with an optimal ratio to tackle the security and stability challenges while functioning the SFCL. The optimisation framework is developed based on time‐domain simulation and takes into account the transient stability indices to size the limiting components of SFCLs given that the main operational requirements such as fault current level and voltage limits are met. Non‐dominated sorting genetic algorithm II is used to find the Pareto fronts for different types of SFCLs. The optimisation and time‐domain simulation results demonstrate great enhancement in the performance of both SFCLs when the optimal ratio between the resistive and inductive elements is chosen for the shunt limiting impedance resulted in improving the transient response and system stability.


  • Dynamic VAR planning for rotor-angle and short-term voltage stability enhancement

    by Ahmad M. Tahboub, Surour Alaraifi, Mohamed Shawky Elmoursi

    In the short-term timescale, separation between load-driven and generator-driven stability problems is rarely well-defined. Allocation of VSC-based VAR compensation, such as STATCOM, has the ability to boost system voltages in the fault-on condition, thus reducing generator power swing, in addition to circumventing delayed voltage recovery upon fault clearing, thereby reducing the risk of induction motor stalling. This paper proposes a multi-objective, hybrid static/dynamic VAR planning strategy incorporating distinct rotor angle and voltage stability indices found through time-domain simulations of full-order system models. The proposed method utilizes parallel high performance computing (HPC) capabilities combined with a genetic algorithm (GA) and is applied on the New England 39-bus system with assumed high penetration of induction machines. The study demonstrates that compared to voltage stability enhancement, improvement of rotor-angle stability through shunt dynamic VAR requires substantial additional capacity, the cost of which can be reduced using hybrid static/dynamic installations.


  • Toward Simulation-Free Estimation of Critical Clearing Time

    by Thanh Long Vu, Surour M. Al Araifi, Mohamed S. El Moursi, Konstantin Turitsyn

    Contingency screening for transient stability of large-scale, strongly nonlinear, interconnected power systems is one of the most computationally challenging parts of Dynamic Security Assessment and requires huge resources to perform time-domain simulations-based assessment. To reduce computational cost of time-domain simulations, direct energy methods have been extensively developed. However, these methods, as well as other existing methods, still rely on time-consuming numerical integration of the fault-on dynamics. This task is computationally hard, since possibly thousands of contingencies need to be scanned and thousands of accompanied fault-on dynamics simulations need to be performed and stored on a regular basis. In this paper, we introduce a novel framework to eliminate the need for fault-on dynamics simulations in contingency screening. This simulation-free framework is based on bounding the fault-on dynamics and extending the recently introduced Lyapunov Function Family approach for transient stability analysis of structure-preserving model. In turn, a lower bound of the critical clearing time is obtained by solving convex optimization problems without relying on any time-domain simulations. A comprehensive analysis is carried out to validate this novel technique on a number of IEEE test cases.


  • Hybrid HTS-FCL Configuration With Adaptive Voltage Compensation Capability

    by Surour Mohamed Alaraifi, Mohamed Shawky El Moursi

    This paper introduces a new hybrid high-temperature superconducting (HTS) fault current limiter (FCL) for improving the transient response system recovery with minimum utilization of HTS material. The hybrid HTS-FCL comprises a reduced size of HTS material connected in series with multistep braking resistors. The presented hybrid HTS-FCL utilizes the fast quench phenomena of HTS materials to ensure fast current limiting action and the multistep braking resistors to provide an adaptive voltage compensation during voltage dips. This combination of HTS and braking resistors allows the HTS material to recover faster by lowering its operating time, mitigates the issue of slow response in conventional braking resistors, and keeps the system fault level below the maximum limit even during offline recovery of its HTS component. A dynamic model representing the hybrid HTS-FCL is developed in PSCAD/EMTDC using a current-dependent model for the HTS combined with dynamic braking resistors associated with a phase voltage control scheme and an HTS bypass scheme for each phase individually. The proposed configuration is tested in a single-machine-to-infinite-bus test system in response to symmetrical and asymmetrical fault conditions. A comprehensive simulation analysis demonstrated the effective performance of the hybrid HTS-FCL with capability of fast fault current limitation and voltage boosting.


  • Voltage Booster Schemes for Fault Ride-Through Enhancement of Variable Speed Wind Turbines

    by Surour Alaraifi, Ahmed Moawwad, Mohamed Shawky El Moursi, Vinod Khadkikar

    This paper presents series grid interface topologies for enhancing the fault ride-through (FRT) performance of doubly-fed induction generator (DFIG)-based wind turbines (WTs). Two voltage booster schemes, 1) dynamic voltage restorer (DVR) and 2) resistive type high temperature superconducting fault current limiter (HTS-FCL), are designed and implemented. The test system represents a WT connected to an electric grid with alternatively employing DVR and HTS-FCL. Both schemes provide fast mitigation of voltage dip that maintains the nominal operating conditions for DFIG-WT. To achieve a flexible control solution for balanced and unbalanced fault conditions, the DVR employs positive and negative sequence controllers while the HTS-FCL is designed to perform fast quenching for each phase individually. The potential of the two booster schemes is evaluated and analyzed in positive and negative sequence reference frames. Comprehensive simulation studies are presented to verify the capability of the series grid interface schemes for ensuring the normal operation and smooth wind power evacuation with effective isolation from grid faults. Furthermore, the grid code requirements of reactive current support are evaluated for both schemes at various fault scenarios.