- Mohamed Shawky El Moursi
Department of Electrical Engineering, Advanced Power and Energy Center, Khalifa University, Abu Dhabi, UAE
10 shared publications Ahmad M. Tahboub
Department of Electrical Engineering and Computer Science, Masdar Institute, Abu Dhabi, United Arab Emirates
1 shared publication- Ahmed Al-Durra
Department of Electrical Engineering, Advanced Power and Energy Center, Khalifa University, Abu Dhabi, UAE
1 shared publication Ahmed Moawwad
Institute Center for Future Energy Systems (iFES), Masdar Institute, Abu Dhabi, UAE
1 shared publication- Ameena Saad Al-Sumaiti
Department of Electrical Engineering and Computer Science, Khalifa University, Abu Dhabi, UAE
1 shared publication H. H. Zeineldin
Faculty of Engineering, Cairo University, Giza, Egypt
1 shared publication
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 20562-20576
High-Order Synchronized Virtual Oscillators for Resilient Control Framework and Robust Grid Integration
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 20562-20576
High-Order Synchronized Virtual Oscillators for Resilient Control Framework and Robust Grid Integration
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (4) , 3218-3221
Beyond SCR: A Comprehensive Approach to System Strength Assessment in IBR-Rich Networks
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (4) , 3218-3221
Beyond SCR: A Comprehensive Approach to System Strength Assessment in IBR-Rich Networks
- 30 March 2024
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 223, 20-33
Chemo and immunotherapy effects on stability regions of tumor models
- 30 March 2024
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 223, 20-33
Chemo and immunotherapy effects on stability regions of tumor models
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (1) , 14-27
Domain of Stability Characterization for Power Systems: A Novel Individual Invariance Method
In this paper, we approach the problem of stability in nonlinear systems through a new perspective that views them as a combination of individual artificial systems carefully chosen to simplify the complex structure of nonlinear systems. This is achieved by recasting nonlinear vector fields as an algebraic sum of individual vector fields for which artificial systems with known invariant sets or at least in forms that allow for tractable approximation of their invariant sets. This attempt to restructure nonlinear systems stands out in comparison to other previous attempts like Lure' systems or network based models as a purely mathematical structuring technique that transcends the physical constraints and dependencies within dynamical models and allows the user to creatively construct artificial systems with the sole focus on the overall stability. The theoretical foundation is provided for a theorem about individual invariance to relate the invariant sets of individual artificial systems to the invariant set of their original system in a way that significantly simplifies the task of approximating regions of attraction. Several examples are used to demonstrate this theorem and we also evaluate the use this theorem for the challenging power system stability problems in both AC and DC grids. The proposed method is successfully applied to the IEEE 39- bus New England system, and a DC converter with constant power load giving accurate and realistic estimations of the critical clearing time and stability regions in comparison to state of the art approaches.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (1) , 14-27
Domain of Stability Characterization for Power Systems: A Novel Individual Invariance Method
In this paper, we approach the problem of stability in nonlinear systems through a new perspective that views them as a combination of individual artificial systems carefully chosen to simplify the complex structure of nonlinear systems. This is achieved by recasting nonlinear vector fields as an algebraic sum of individual vector fields for which artificial systems with known invariant sets or at least in forms that allow for tractable approximation of their invariant sets. This attempt to restructure nonlinear systems stands out in comparison to other previous attempts like Lure' systems or network based models as a purely mathematical structuring technique that transcends the physical constraints and dependencies within dynamical models and allows the user to creatively construct artificial systems with the sole focus on the overall stability. The theoretical foundation is provided for a theorem about individual invariance to relate the invariant sets of individual artificial systems to the invariant set of their original system in a way that significantly simplifies the task of approximating regions of attraction. Several examples are used to demonstrate this theorem and we also evaluate the use this theorem for the challenging power system stability problems in both AC and DC grids. The proposed method is successfully applied to the IEEE 39- bus New England system, and a DC converter with constant power load giving accurate and realistic estimations of the critical clearing time and stability regions in comparison to state of the art approaches.
- 23 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 35 (2) , 1264-1273
Individual Functions Method for Power System Transient Stability Assessment
This paper introduces an alternative description of autonomous dynamical systems as a sum of individual vector fields. This structure of a dynamical system gives us the opportunity to construct individual Lyapunov-like functions to certify stability of an equilibrium point. A theorem on individual functions is developed in a quadratic form to maintain computational efficiency. As a corollary to the developed theory, we conclude that regions of attraction can be estimated by sub-level sets of individual quadratic functions, and through geometric programs they can easily be maximized efficiently. Theoretical findings in this paper are examined on transient stability problem in power systems for both single machine to infinite bus and multi-machine systems with promising results for critical clearing time estimation compared to the values obtained from time domain simulations.
- 23 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 35 (2) , 1264-1273
Individual Functions Method for Power System Transient Stability Assessment
This paper introduces an alternative description of autonomous dynamical systems as a sum of individual vector fields. This structure of a dynamical system gives us the opportunity to construct individual Lyapunov-like functions to certify stability of an equilibrium point. A theorem on individual functions is developed in a quadratic form to maintain computational efficiency. As a corollary to the developed theory, we conclude that regions of attraction can be estimated by sub-level sets of individual quadratic functions, and through geometric programs they can easily be maximized efficiently. Theoretical findings in this paper are examined on transient stability problem in power systems for both single machine to infinite bus and multi-machine systems with promising results for critical clearing time estimation compared to the values obtained from time domain simulations.
- Open Access
- 23 June 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (9) , 2155-2163
Design considerations of superconducting fault current limiters for power system stability enhancement
This study identifies the type and size of the optimal shunt limiting impedance for superconducting fault current limiter (SFCL). Since the shunt impedance has been widely categorised to be either inductive or resistive element depending on the type of limiting impedance, the proposed design considerations will significantly affect the transient response and system stability. Therefore, the presented problem formulation optimises the design of SFCL by allowing the limiting shunt impedance to combine both resistive and inductive elements with an optimal ratio to tackle the security and stability challenges while functioning the SFCL. The optimisation framework is developed based on time‐domain simulation and takes into account the transient stability indices to size the limiting components of SFCLs given that the main operational requirements such as fault current level and voltage limits are met. Non‐dominated sorting genetic algorithm II is used to find the Pareto fronts for different types of SFCLs. The optimisation and time‐domain simulation results demonstrate great enhancement in the performance of both SFCLs when the optimal ratio between the resistive and inductive elements is chosen for the shunt limiting impedance resulted in improving the transient response and system stability.
- 23 June 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (9) , 2155-2163
Open AccessDesign considerations of superconducting fault current limiters for power system stability enhancement
This study identifies the type and size of the optimal shunt limiting impedance for superconducting fault current limiter (SFCL). Since the shunt impedance has been widely categorised to be either inductive or resistive element depending on the type of limiting impedance, the proposed design considerations will significantly affect the transient response and system stability. Therefore, the presented problem formulation optimises the design of SFCL by allowing the limiting shunt impedance to combine both resistive and inductive elements with an optimal ratio to tackle the security and stability challenges while functioning the SFCL. The optimisation framework is developed based on time‐domain simulation and takes into account the transient stability indices to size the limiting components of SFCLs given that the main operational requirements such as fault current level and voltage limits are met. Non‐dominated sorting genetic algorithm II is used to find the Pareto fronts for different types of SFCLs. The optimisation and time‐domain simulation results demonstrate great enhancement in the performance of both SFCLs when the optimal ratio between the resistive and inductive elements is chosen for the shunt limiting impedance resulted in improving the transient response and system stability.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 592-596
Dynamic VAR planning for rotor-angle and short-term voltage stability enhancement
In the short-term timescale, separation between load-driven and generator-driven stability problems is rarely well-defined. Allocation of VSC-based VAR compensation, such as STATCOM, has the ability to boost system voltages in the fault-on condition, thus reducing generator power swing, in addition to circumventing delayed voltage recovery upon fault clearing, thereby reducing the risk of induction motor stalling. This paper proposes a multi-objective, hybrid static/dynamic VAR planning strategy incorporating distinct rotor angle and voltage stability indices found through time-domain simulations of full-order system models. The proposed method utilizes parallel high performance computing (HPC) capabilities combined with a genetic algorithm (GA) and is applied on the New England 39-bus system with assumed high penetration of induction machines. The study demonstrates that compared to voltage stability enhancement, improvement of rotor-angle stability through shunt dynamic VAR requires substantial additional capacity, the cost of which can be reduced using hybrid static/dynamic installations.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 592-596
Dynamic VAR planning for rotor-angle and short-term voltage stability enhancement
In the short-term timescale, separation between load-driven and generator-driven stability problems is rarely well-defined. Allocation of VSC-based VAR compensation, such as STATCOM, has the ability to boost system voltages in the fault-on condition, thus reducing generator power swing, in addition to circumventing delayed voltage recovery upon fault clearing, thereby reducing the risk of induction motor stalling. This paper proposes a multi-objective, hybrid static/dynamic VAR planning strategy incorporating distinct rotor angle and voltage stability indices found through time-domain simulations of full-order system models. The proposed method utilizes parallel high performance computing (HPC) capabilities combined with a genetic algorithm (GA) and is applied on the New England 39-bus system with assumed high penetration of induction machines. The study demonstrates that compared to voltage stability enhancement, improvement of rotor-angle stability through shunt dynamic VAR requires substantial additional capacity, the cost of which can be reduced using hybrid static/dynamic installations.
- 26 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 31 (6) , 4722-4731
Toward Simulation-Free Estimation of Critical Clearing Time
Contingency screening for transient stability of large-scale, strongly nonlinear, interconnected power systems is one of the most computationally challenging parts of Dynamic Security Assessment and requires huge resources to perform time-domain simulations-based assessment. To reduce computational cost of time-domain simulations, direct energy methods have been extensively developed. However, these methods, as well as other existing methods, still rely on time-consuming numerical integration of the fault-on dynamics. This task is computationally hard, since possibly thousands of contingencies need to be scanned and thousands of accompanied fault-on dynamics simulations need to be performed and stored on a regular basis. In this paper, we introduce a novel framework to eliminate the need for fault-on dynamics simulations in contingency screening. This simulation-free framework is based on bounding the fault-on dynamics and extending the recently introduced Lyapunov Function Family approach for transient stability analysis of structure-preserving model. In turn, a lower bound of the critical clearing time is obtained by solving convex optimization problems without relying on any time-domain simulations. A comprehensive analysis is carried out to validate this novel technique on a number of IEEE test cases.
- 26 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 31 (6) , 4722-4731
Toward Simulation-Free Estimation of Critical Clearing Time
Contingency screening for transient stability of large-scale, strongly nonlinear, interconnected power systems is one of the most computationally challenging parts of Dynamic Security Assessment and requires huge resources to perform time-domain simulations-based assessment. To reduce computational cost of time-domain simulations, direct energy methods have been extensively developed. However, these methods, as well as other existing methods, still rely on time-consuming numerical integration of the fault-on dynamics. This task is computationally hard, since possibly thousands of contingencies need to be scanned and thousands of accompanied fault-on dynamics simulations need to be performed and stored on a regular basis. In this paper, we introduce a novel framework to eliminate the need for fault-on dynamics simulations in contingency screening. This simulation-free framework is based on bounding the fault-on dynamics and extending the recently introduced Lyapunov Function Family approach for transient stability analysis of structure-preserving model. In turn, a lower bound of the critical clearing time is obtained by solving convex optimization problems without relying on any time-domain simulations. A comprehensive analysis is carried out to validate this novel technique on a number of IEEE test cases.
- 12 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 24 (6) , 1-8
Hybrid HTS-FCL Configuration With Adaptive Voltage Compensation Capability
This paper introduces a new hybrid high-temperature superconducting (HTS) fault current limiter (FCL) for improving the transient response system recovery with minimum utilization of HTS material. The hybrid HTS-FCL comprises a reduced size of HTS material connected in series with multistep braking resistors. The presented hybrid HTS-FCL utilizes the fast quench phenomena of HTS materials to ensure fast current limiting action and the multistep braking resistors to provide an adaptive voltage compensation during voltage dips. This combination of HTS and braking resistors allows the HTS material to recover faster by lowering its operating time, mitigates the issue of slow response in conventional braking resistors, and keeps the system fault level below the maximum limit even during offline recovery of its HTS component. A dynamic model representing the hybrid HTS-FCL is developed in PSCAD/EMTDC using a current-dependent model for the HTS combined with dynamic braking resistors associated with a phase voltage control scheme and an HTS bypass scheme for each phase individually. The proposed configuration is tested in a single-machine-to-infinite-bus test system in response to symmetrical and asymmetrical fault conditions. A comprehensive simulation analysis demonstrated the effective performance of the hybrid HTS-FCL with capability of fast fault current limitation and voltage boosting.
- 12 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 24 (6) , 1-8
Hybrid HTS-FCL Configuration With Adaptive Voltage Compensation Capability
This paper introduces a new hybrid high-temperature superconducting (HTS) fault current limiter (FCL) for improving the transient response system recovery with minimum utilization of HTS material. The hybrid HTS-FCL comprises a reduced size of HTS material connected in series with multistep braking resistors. The presented hybrid HTS-FCL utilizes the fast quench phenomena of HTS materials to ensure fast current limiting action and the multistep braking resistors to provide an adaptive voltage compensation during voltage dips. This combination of HTS and braking resistors allows the HTS material to recover faster by lowering its operating time, mitigates the issue of slow response in conventional braking resistors, and keeps the system fault level below the maximum limit even during offline recovery of its HTS component. A dynamic model representing the hybrid HTS-FCL is developed in PSCAD/EMTDC using a current-dependent model for the HTS combined with dynamic braking resistors associated with a phase voltage control scheme and an HTS bypass scheme for each phase individually. The proposed configuration is tested in a single-machine-to-infinite-bus test system in response to symmetrical and asymmetrical fault conditions. A comprehensive simulation analysis demonstrated the effective performance of the hybrid HTS-FCL with capability of fast fault current limitation and voltage boosting.
- 16 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 4 (4) , 1071-1081
Voltage Booster Schemes for Fault Ride-Through Enhancement of Variable Speed Wind Turbines
This paper presents series grid interface topologies for enhancing the fault ride-through (FRT) performance of doubly-fed induction generator (DFIG)-based wind turbines (WTs). Two voltage booster schemes, 1) dynamic voltage restorer (DVR) and 2) resistive type high temperature superconducting fault current limiter (HTS-FCL), are designed and implemented. The test system represents a WT connected to an electric grid with alternatively employing DVR and HTS-FCL. Both schemes provide fast mitigation of voltage dip that maintains the nominal operating conditions for DFIG-WT. To achieve a flexible control solution for balanced and unbalanced fault conditions, the DVR employs positive and negative sequence controllers while the HTS-FCL is designed to perform fast quenching for each phase individually. The potential of the two booster schemes is evaluated and analyzed in positive and negative sequence reference frames. Comprehensive simulation studies are presented to verify the capability of the series grid interface schemes for ensuring the normal operation and smooth wind power evacuation with effective isolation from grid faults. Furthermore, the grid code requirements of reactive current support are evaluated for both schemes at various fault scenarios.
- 16 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 4 (4) , 1071-1081
Voltage Booster Schemes for Fault Ride-Through Enhancement of Variable Speed Wind Turbines
This paper presents series grid interface topologies for enhancing the fault ride-through (FRT) performance of doubly-fed induction generator (DFIG)-based wind turbines (WTs). Two voltage booster schemes, 1) dynamic voltage restorer (DVR) and 2) resistive type high temperature superconducting fault current limiter (HTS-FCL), are designed and implemented. The test system represents a WT connected to an electric grid with alternatively employing DVR and HTS-FCL. Both schemes provide fast mitigation of voltage dip that maintains the nominal operating conditions for DFIG-WT. To achieve a flexible control solution for balanced and unbalanced fault conditions, the DVR employs positive and negative sequence controllers while the HTS-FCL is designed to perform fast quenching for each phase individually. The potential of the two booster schemes is evaluated and analyzed in positive and negative sequence reference frames. Comprehensive simulation studies are presented to verify the capability of the series grid interface schemes for ensuring the normal operation and smooth wind power evacuation with effective isolation from grid faults. Furthermore, the grid code requirements of reactive current support are evaluated for both schemes at various fault scenarios.