Dennis King Hang Yee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dennis King Hang Yee has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Christian Fang
Queen Mary Hospital, The University of Hong Kong
8 shared publicationsFrankie Leung
Queen Mary Hospital, University of Hong Kong, Pokfulam, Hong Kong
7 shared publicationsTak-Wing Lau
The Unviersity of Hong Kong, Pokfulam, Hong Kong
4 shared publications- Christian Fang
Queen Mary Hospital
2 shared publications - Frankie Leung
Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
2 shared publications Tak-Man Wong
Hong Kong University Shenzhen Hospital, Shenzhen, China
2 shared publications
Latest Publications
- 21 March 2024
- Published by Springer Nature
- p. 113-136
Management of Femoral Neck and Per-Trochanteric Fractures Including New Technology
- 21 March 2024
- Published by Springer Nature
- p. 113-136
Management of Femoral Neck and Per-Trochanteric Fractures Including New Technology
- 21 March 2024
- Published by Springer Nature
- p. 33-59
Choice of Management and Techniques of Proximal Humeral Fixation
- 21 March 2024
- Published by Springer Nature
- p. 33-59
Choice of Management and Techniques of Proximal Humeral Fixation
- Open Access
- 23 October 2023
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 43, 14-20
COVID-19 hip fracture outcomes: The role of Ct values and D-dimer levels?
- 23 October 2023
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 43, 14-20
Open AccessCOVID-19 hip fracture outcomes: The role of Ct values and D-dimer levels?
- Open Access
- 6 September 2023
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 20 (1) , e2574
Surgical accuracy of image‐free versus image‐based robotic‐assisted total knee arthroplasty
Background: This study investigated the accuracy in achieving proper lower limb alignment and component positions after total knee replacement (TKR) with image‐free and image‐based robotic‐assisted TKR.Methods: A total of 129 patients (166 knees) suffering from end‐stage knee arthritis who underwent TKA operated by robotic‐assisted surgery between the years 2018 and mid‐2021 were recruited. Radiological outcomes were compared between image‐free and image‐based robotic‐assisted surgical systems.Results: There were significant differences between the two robotic systems when comparing the mean planned component alignment and the mean measured alignment on radiographs, in which the image‐free robotic‐assisted system was more varus, whereas the image‐based robotic‐assisted system was more valgus for both the mean femoral and tibial component coronal alignment (p < 0.001). For tibial component sagittal alignment, the image‐based group had a larger deviation from the planned posterior slope (p < 0.001).Conclusion: Image‐free and image‐based robotic assisted TKR had differing accuracy in femoral and tibial alignment.
- 6 September 2023
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 20 (1) , e2574
Open AccessSurgical accuracy of image‐free versus image‐based robotic‐assisted total knee arthroplasty
Background: This study investigated the accuracy in achieving proper lower limb alignment and component positions after total knee replacement (TKR) with image‐free and image‐based robotic‐assisted TKR.Methods: A total of 129 patients (166 knees) suffering from end‐stage knee arthritis who underwent TKA operated by robotic‐assisted surgery between the years 2018 and mid‐2021 were recruited. Radiological outcomes were compared between image‐free and image‐based robotic‐assisted surgical systems.Results: There were significant differences between the two robotic systems when comparing the mean planned component alignment and the mean measured alignment on radiographs, in which the image‐free robotic‐assisted system was more varus, whereas the image‐based robotic‐assisted system was more valgus for both the mean femoral and tibial component coronal alignment (p < 0.001). For tibial component sagittal alignment, the image‐based group had a larger deviation from the planned posterior slope (p < 0.001).Conclusion: Image‐free and image‐based robotic assisted TKR had differing accuracy in femoral and tibial alignment.
- Open Access
- 11 April 2022
- Published by SAGE Publications in Geriatric Orthopaedic Surgery & Rehabilitation
- Vol. 13
Orthogeriatric Multidisciplinary Co-Management Across Acute and Rehabilitation Care Improves Length of Stay, Functional Outcomes and Complications in Geriatric Hip Fracture Patients
Introduction: As the global number of geriatric hip fracture cases continues to proliferate, a newly developed orthogeriatric co-management multidisciplinary care model has been implemented since November 2018 to meet further increases in demand. Our objective was to evaluate the effectiveness of the new pathway in improving the clinical outcomes of fragility hip fractures. Methods: The data of geriatric hip fracture patients from 1 April 2018 till 30 October 2018 was collected as the conventional orthopaedic care model (pre-orthogeriatric care model) to compare with data from the orthogeriatric co-management model, 1 Feb 2019 till 31 August 2019. Clinical outcomes were analyzed between the groups, with the efficiency of the programme reflected in the total length of stay in acute and convalescent hospitals. Results: 194 patients were recruited to the conventional group and 207 were recruited to the orthogeriatric group, 290 patients (72.3%) were female. The mean (SD) patient age was 84.2 (7.9) years. The median length of stay in the acute and rehabilitation hospitals decreased by 1 day and 2 days, respectively (P=.001). The orthogeriatric group was associated with a higher Modified Barthel Index score on discharge from the rehabilitation hospital and more patients in the orthogeriatric collaboration group received osteoporosis medication prescription within one year after the index fracture. There was no difference in the 28-days unplanned readmission rate, complication rate, mortality rate or Elderly Mobility Scale scores on discharge from the rehabilitation hospital between the two groups. Conclusion: Orthogeriatric collaboration has been proven to be effective in terms of a decreased length of stay in both the acute and the rehabilitation hospitals.
- 11 April 2022
- Published by SAGE Publications in Geriatric Orthopaedic Surgery & Rehabilitation
- Vol. 13
Open AccessOrthogeriatric Multidisciplinary Co-Management Across Acute and Rehabilitation Care Improves Length of Stay, Functional Outcomes and Complications in Geriatric Hip Fracture Patients
Introduction: As the global number of geriatric hip fracture cases continues to proliferate, a newly developed orthogeriatric co-management multidisciplinary care model has been implemented since November 2018 to meet further increases in demand. Our objective was to evaluate the effectiveness of the new pathway in improving the clinical outcomes of fragility hip fractures. Methods: The data of geriatric hip fracture patients from 1 April 2018 till 30 October 2018 was collected as the conventional orthopaedic care model (pre-orthogeriatric care model) to compare with data from the orthogeriatric co-management model, 1 Feb 2019 till 31 August 2019. Clinical outcomes were analyzed between the groups, with the efficiency of the programme reflected in the total length of stay in acute and convalescent hospitals. Results: 194 patients were recruited to the conventional group and 207 were recruited to the orthogeriatric group, 290 patients (72.3%) were female. The mean (SD) patient age was 84.2 (7.9) years. The median length of stay in the acute and rehabilitation hospitals decreased by 1 day and 2 days, respectively (P=.001). The orthogeriatric group was associated with a higher Modified Barthel Index score on discharge from the rehabilitation hospital and more patients in the orthogeriatric collaboration group received osteoporosis medication prescription within one year after the index fracture. There was no difference in the 28-days unplanned readmission rate, complication rate, mortality rate or Elderly Mobility Scale scores on discharge from the rehabilitation hospital between the two groups. Conclusion: Orthogeriatric collaboration has been proven to be effective in terms of a decreased length of stay in both the acute and the rehabilitation hospitals.
- 25 April 2020
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 140 (12) , 1957-1964
Cementation: for better or worse? Interim results of a multi-centre cohort study using a fenestrated spiral blade cephalomedullary device for pertrochanteric fractures in the elderly
Introduction Cephallomedullary nail fixation is currently the most popular treatment for pertrochanteric fractures. Despite continuous improvement in implant design, fixation failures still occur in a concerning number of cases. This study aims to evaluate the effect of cement augmentation of the new-generation Trochanteric Femoral Nail Advanced (TFNA) perforated spiral blade on complications including fixation failure in the elderly population. Materials and methods We retrospectively evaluated 107 patients aged 65 + treated for pertrochanteric fractures via TFNA between 2015 and 2019 based on whether cementation was used. Baseline demographics, fracture classifications, and reduction quality were compared. Patients with a follow-up of at least 6 months were analyzed for the primary outcome of fixation failure. All patients, regardless of loss to follow-up within 6 months, were analyzed for other complications including mortality. Results Seventy-six patients (47 cemented, 29 non-cemented) had a minimum follow-up of 6 months (mean 13 months). There were no statistically significant differences between the two treatment groups in terms of patient demographics, ASA or AO/OTA fracture classification, reduction quality, or length of follow-up. There was a lower rate of fixation failure in the cement-augmented (CA) group versus the non-cement-augmented (NCA) group (2.1% vs 13.8%; p = 0.047). No cut-out or cut-through was observed in the CA group. Seven patients had adverse intraoperative events, with a significantly higher rate of fixation failure in these patients (40% vs 2.8%; p = 0.00). There were no statistically significant differences in 30-day mortality (6.3% CA vs 4.3% NCA; p = 0.632) or 3-month mortality (9.5% CA vs 12.8% NCA; p = 0.589). Conclusions Cementation of TFNA blades may decrease risk of fixation failure, however, the surgeon must be aware of potential complications such as cement leakage into the hip joint and be able to manage them as they arise.
- 25 April 2020
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 140 (12) , 1957-1964
Cementation: for better or worse? Interim results of a multi-centre cohort study using a fenestrated spiral blade cephalomedullary device for pertrochanteric fractures in the elderly
Introduction Cephallomedullary nail fixation is currently the most popular treatment for pertrochanteric fractures. Despite continuous improvement in implant design, fixation failures still occur in a concerning number of cases. This study aims to evaluate the effect of cement augmentation of the new-generation Trochanteric Femoral Nail Advanced (TFNA) perforated spiral blade on complications including fixation failure in the elderly population. Materials and methods We retrospectively evaluated 107 patients aged 65 + treated for pertrochanteric fractures via TFNA between 2015 and 2019 based on whether cementation was used. Baseline demographics, fracture classifications, and reduction quality were compared. Patients with a follow-up of at least 6 months were analyzed for the primary outcome of fixation failure. All patients, regardless of loss to follow-up within 6 months, were analyzed for other complications including mortality. Results Seventy-six patients (47 cemented, 29 non-cemented) had a minimum follow-up of 6 months (mean 13 months). There were no statistically significant differences between the two treatment groups in terms of patient demographics, ASA or AO/OTA fracture classification, reduction quality, or length of follow-up. There was a lower rate of fixation failure in the cement-augmented (CA) group versus the non-cement-augmented (NCA) group (2.1% vs 13.8%; p = 0.047). No cut-out or cut-through was observed in the CA group. Seven patients had adverse intraoperative events, with a significantly higher rate of fixation failure in these patients (40% vs 2.8%; p = 0.00). There were no statistically significant differences in 30-day mortality (6.3% CA vs 4.3% NCA; p = 0.632) or 3-month mortality (9.5% CA vs 12.8% NCA; p = 0.589). Conclusions Cementation of TFNA blades may decrease risk of fixation failure, however, the surgeon must be aware of potential complications such as cement leakage into the hip joint and be able to manage them as they arise.
- Open Access
- 1 December 2019
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 7 (S8) , S387
Distal radius fracture fixation in the elderly: does better form equal better function?
Distal radius fracture fixation in the elderly: does better form equal better function?
- 1 December 2019
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 7 (S8) , S387
Open AccessDistal radius fracture fixation in the elderly: does better form equal better function?
Distal radius fracture fixation in the elderly: does better form equal better function?
- Open Access
- 1 January 2019
- Published by SAGE Publications in Geriatric Orthopaedic Surgery & Rehabilitation
- Vol. 10
Comparing 3 Different Techniques of Patella Fracture Fixation and Their Complications
Patella fractures managed by fixation with metal implants often cause local soft tissue irritation and necessitate implant removal. An alternative is to utilize suture-based fixation methods. We have adopted suture and hybrid fixation in the routine management of patella fractures. Here, we compare the results of 3 fixation techniques. Eighty-seven eligible patients underwent patella fracture fixation over a 3-year period. As determined by fracture configuration, patients received (1) suture fixation (transosseous sutures and figure-of-eight tension banding with FiberWire), (2) hybrid fixation (transosseous FiberWire sutures and metal tension banding), or (3) metal fixation. Primary outcome measures included reoperation rate and soft tissue irritation. Secondary outcomes included surgical complications, radiological, and functional parameters. Reoperation rate was highest for metal fixation (25/57, 43.9%) and lowest for suture fixation (2/13, 15.4%). Soft tissue irritation necessitating implant removal was the predominant reason for reoperation and was significantly less prevalent following suture fixation (1/13, 7.7%, P < .01). Hybrid fixation resulted in similar rates of soft tissue irritation (6/17, 35.3%) and implant removal (7/17, 41.2%) as compared to metal fixation. There was a significant increase in patella baja (13/17, 76.5%) and reduction in Insall-Salvati ratio (0.742; 95% confidence interval: 0.682-0.802) following hybrid fixation as compared to the other 2 fixation methods (P < .05). Suture fixation results in the least amount of soft tissue irritation and lowest reoperation rate, but these advantages are negated with the addition of a metal tension band wire. Hybrid fixation also unbalances the extensor mechanism. Patients should be counseled as to the expected sequelae of their fixation method. Suture fixation is the favored means to fix distal pole fractures of the patella. An additional metal tension band loop may confer additional stability but should be applied with caution.
- 1 January 2019
- Published by SAGE Publications in Geriatric Orthopaedic Surgery & Rehabilitation
- Vol. 10
Open AccessComparing 3 Different Techniques of Patella Fracture Fixation and Their Complications
Patella fractures managed by fixation with metal implants often cause local soft tissue irritation and necessitate implant removal. An alternative is to utilize suture-based fixation methods. We have adopted suture and hybrid fixation in the routine management of patella fractures. Here, we compare the results of 3 fixation techniques. Eighty-seven eligible patients underwent patella fracture fixation over a 3-year period. As determined by fracture configuration, patients received (1) suture fixation (transosseous sutures and figure-of-eight tension banding with FiberWire), (2) hybrid fixation (transosseous FiberWire sutures and metal tension banding), or (3) metal fixation. Primary outcome measures included reoperation rate and soft tissue irritation. Secondary outcomes included surgical complications, radiological, and functional parameters. Reoperation rate was highest for metal fixation (25/57, 43.9%) and lowest for suture fixation (2/13, 15.4%). Soft tissue irritation necessitating implant removal was the predominant reason for reoperation and was significantly less prevalent following suture fixation (1/13, 7.7%, P < .01). Hybrid fixation resulted in similar rates of soft tissue irritation (6/17, 35.3%) and implant removal (7/17, 41.2%) as compared to metal fixation. There was a significant increase in patella baja (13/17, 76.5%) and reduction in Insall-Salvati ratio (0.742; 95% confidence interval: 0.682-0.802) following hybrid fixation as compared to the other 2 fixation methods (P < .05). Suture fixation results in the least amount of soft tissue irritation and lowest reoperation rate, but these advantages are negated with the addition of a metal tension band wire. Hybrid fixation also unbalances the extensor mechanism. Patients should be counseled as to the expected sequelae of their fixation method. Suture fixation is the favored means to fix distal pole fractures of the patella. An additional metal tension band loop may confer additional stability but should be applied with caution.
- 3 January 2018
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (8) , 1789-1794
Hip fracture time-to-surgery and mortality revisited: mitigating comorbidity confounding by effect of holidays on surgical timing
The association between delayed hip fracture surgery and mortality remains elusive because of strong confounding by comorbidity factors. We designed a study to investigate the effect of small delays in surgery due to holidays.
- 3 January 2018
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (8) , 1789-1794
Hip fracture time-to-surgery and mortality revisited: mitigating comorbidity confounding by effect of holidays on surgical timing
The association between delayed hip fracture surgery and mortality remains elusive because of strong confounding by comorbidity factors. We designed a study to investigate the effect of small delays in surgery due to holidays.