Vittorino Lanzio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vittorino Lanzio has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Stefano Cabrini
The Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, USA
4 shared publications Gregory Telian
Adesnik Lab, University of California Berkeley, Berkeley, USA
2 shared publicationsHillel Adesnik
Adesnik Lab, University of California Berkeley, Berkeley, USA
2 shared publicationsMelanie West
The Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, USA
2 shared publicationsPaolo Micheletti
Department of Applied Science and Technology, Politecnico di Torino, Torino, Italy
2 shared publicationsScott Dhuey
The Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, USA
2 shared publications
Latest Publications
- 23 November 2021
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 39 (6) , 063001
Neural optoelectrodes merging semiconductor scalability with polymeric-like bendability for low damage acute in vivo neuron readout and stimulation
Neural optoelectrodes can read and manipulate large numbers of neurons in vivo. However, state-of-the-art devices rely on either standard microfabrication materials (i.e., silicon and silicon nitride), which result in high scalability and throughput but cause severe brain damage due to implant stiffness, or polymeric devices, which are more compliant but whose scalability and implantation in the brain are challenging. Here, we merge the gap between silicon-based fabrication scalability and low (polymeric-like) stiffness by fabricating a nitride and oxide-based optoelectrode with a high density of sensing microelectrodes, passive photonic circuits, and a very small tip thickness (5 μm). We achieve this by removing all the silicon supporting material underneath the probe’s tip—while leaving only the nitride and glass optical ultrathin layers—through a single isotropic etch step. Our optoelectrode integrates 64 electrodes and multiple passive optical outputs, resulting in a cross-sectional area coefficient (the cross section divided by the number of sensors and light emitters) of 3.1—smaller than other optoelectrodes. It also combines a low bending stiffness (∼4.4 × 10−11 N m2), comparable or approaching several state-of-the-art polymeric optoelectrodes. We tested several mechanical insertions of our devices in vivo in rats and demonstrated that we can pierce the pia without using additional temporary supports.
- 23 November 2021
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 39 (6) , 063001
Neural optoelectrodes merging semiconductor scalability with polymeric-like bendability for low damage acute in vivo neuron readout and stimulation
Neural optoelectrodes can read and manipulate large numbers of neurons in vivo. However, state-of-the-art devices rely on either standard microfabrication materials (i.e., silicon and silicon nitride), which result in high scalability and throughput but cause severe brain damage due to implant stiffness, or polymeric devices, which are more compliant but whose scalability and implantation in the brain are challenging. Here, we merge the gap between silicon-based fabrication scalability and low (polymeric-like) stiffness by fabricating a nitride and oxide-based optoelectrode with a high density of sensing microelectrodes, passive photonic circuits, and a very small tip thickness (5 μm). We achieve this by removing all the silicon supporting material underneath the probe’s tip—while leaving only the nitride and glass optical ultrathin layers—through a single isotropic etch step. Our optoelectrode integrates 64 electrodes and multiple passive optical outputs, resulting in a cross-sectional area coefficient (the cross section divided by the number of sensors and light emitters) of 3.1—smaller than other optoelectrodes. It also combines a low bending stiffness (∼4.4 × 10−11 N m2), comparable or approaching several state-of-the-art polymeric optoelectrodes. We tested several mechanical insertions of our devices in vivo in rats and demonstrated that we can pierce the pia without using additional temporary supports.
- Open Access
- 26 May 2021
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 7 (1) , 1-14
Small footprint optoelectrodes using ring resonators for passive light localization
The combination of electrophysiology and optogenetics enables the exploration of how the brain operates down to a single neuron and its network activity. Neural probes are in vivo invasive devices that integrate sensors and stimulation sites to record and manipulate neuronal activity with high spatiotemporal resolution. State-of-the-art probes are limited by tradeoffs involving their lateral dimension, number of sensors, and ability to access independent stimulation sites. Here, we realize a highly scalable probe that features three-dimensional integration of small-footprint arrays of sensors and nanophotonic circuits to scale the density of sensors per cross-section by one order of magnitude with respect to state-of-the-art devices. For the first time, we overcome the spatial limit of the nanophotonic circuit by coupling only one waveguide to numerous optical ring resonators as passive nanophotonic switches. With this strategy, we achieve accurate on-demand light localization while avoiding spatially demanding bundles of waveguides and demonstrate the feasibility with a proof-of-concept device and its scalability towards high-resolution and low-damage neural optoelectrodes.
- 26 May 2021
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 7 (1) , 1-14
Open AccessSmall footprint optoelectrodes using ring resonators for passive light localization
The combination of electrophysiology and optogenetics enables the exploration of how the brain operates down to a single neuron and its network activity. Neural probes are in vivo invasive devices that integrate sensors and stimulation sites to record and manipulate neuronal activity with high spatiotemporal resolution. State-of-the-art probes are limited by tradeoffs involving their lateral dimension, number of sensors, and ability to access independent stimulation sites. Here, we realize a highly scalable probe that features three-dimensional integration of small-footprint arrays of sensors and nanophotonic circuits to scale the density of sensors per cross-section by one order of magnitude with respect to state-of-the-art devices. For the first time, we overcome the spatial limit of the nanophotonic circuit by coupling only one waveguide to numerous optical ring resonators as passive nanophotonic switches. With this strategy, we achieve accurate on-demand light localization while avoiding spatially demanding bundles of waveguides and demonstrate the feasibility with a proof-of-concept device and its scalability towards high-resolution and low-damage neural optoelectrodes.
- 6 April 2021
- Published by IOP Publishing in Nanotechnology
- Vol. 32 (26) , 265201
Scalable nanophotonic neural probes for multicolor and on-demand light delivery in brain tissue
Neural probes are in vivo brain-invasive devices that record and manipulate neural circuits using electricity, light, or drugs. The capability to shine distinct wavelengths and control their respective output locations for activation or deactivation of specific groups of neurons is desirable but remains unachieved. Here, we discuss our probe’s capability to deliver two independently controllable wavelengths (450 and 655 nm) in the location(s) of interest using nanophotonic directional couplers and ring resonators. These nanophotonics are scalable to dozens of outputs without significantly increasing the device’s lateral dimensions. Furthermore, they are entirely passive and thus do not require electrical input that results in heat generation. Besides, we integrate a high number of electrodes for a simultaneous neural activity readout. Thus, we overcome the challenges associated with multicolor illumination for neural devices by exploiting the capability of miniaturizable, passive probes to deliver two different frequencies in several areas of interest. These devices open the path towards investigating the in vivo electrical signal propagation under the individual or simultaneous activation or inhibition of distinct brain regions.
- 6 April 2021
- Published by IOP Publishing in Nanotechnology
- Vol. 32 (26) , 265201
Scalable nanophotonic neural probes for multicolor and on-demand light delivery in brain tissue
Neural probes are in vivo brain-invasive devices that record and manipulate neural circuits using electricity, light, or drugs. The capability to shine distinct wavelengths and control their respective output locations for activation or deactivation of specific groups of neurons is desirable but remains unachieved. Here, we discuss our probe’s capability to deliver two independently controllable wavelengths (450 and 655 nm) in the location(s) of interest using nanophotonic directional couplers and ring resonators. These nanophotonics are scalable to dozens of outputs without significantly increasing the device’s lateral dimensions. Furthermore, they are entirely passive and thus do not require electrical input that results in heat generation. Besides, we integrate a high number of electrodes for a simultaneous neural activity readout. Thus, we overcome the challenges associated with multicolor illumination for neural devices by exploiting the capability of miniaturizable, passive probes to deliver two different frequencies in several areas of interest. These devices open the path towards investigating the in vivo electrical signal propagation under the individual or simultaneous activation or inhibition of distinct brain regions.
- Open Access
- 30 June 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanolithography, MEMS, and MOEMS
- Vol. 17 (02) , 025503-8
High-density electrical and optical probes for neural readout and light focusing in deep brain tissue
One of the main goals of the Brain Research through Advancing Innovative Neurotechnologies (BRAIN) Initiative 1 is to map the brain at the single neuron and synapse level to understand how neural communication drives behavior and affects brain disorders. Nanotechnology has opened new pathways to interface single brain cells in vivo in brain tissue due to dimensions comparable to neural cells and the feasibility of integration of different types of sensors. In particular, Michigan neural probes are invasive devices built on a silicon (or polymeric) substrate.2 Michigan neural probes allow the use of micro and nanofabrication techniques (which imply high yield, low defectivity, and scalability) and integrate a high density of arrays of sensors (density limited mainly by the lithography resolution). The main element of these type of brain–machine interfaces is a sharp silicon tip (the shank) that is inserted into the animal’s brain and which contains passive or active sensors [electrodes,3,4 microfluidic channels,5 optical diffraction gratings,6 and micro-light-emitting diodes (LEDs)7]. Sensors on the shank are connected, due to metallic interconnections, waveguides, or microfluidic channels, to an extracranial device region having bond pads,8 optical coupling gratings, or fluidic interfaces.5 Many in vivo neuroscience studies employ Michigan neural probes to record or stimulate neurons by means of different types of techniques. Among these, invasive electrophysiology measurements (performed due to electrodes on the device’s shank) provide information on cortical circuit communication around the device through the recording of extracellular potentials.9 Another technique, optogenetics, uses light to manipulate neural population activity. Specific types of neurons are genetically modified by the introduction of opsins in the brain using viral vectors or anatomical targeting strategies.10,11 Channelrhodopsins are light-sensitive proteins that are able to enhance or inhibit neural population activity in the presence of light with the correct wavelength (around 450 to 473 nm).12 Different studies involving the manipulation of neural populations using optogenetic tools have shown promising future applications in brain disorders research.13,14 The simultaneous use of both electrophysiology and optogenetics in the same experiment is a necessary step to evolve neuroscience experiments.15,16 Different methods allow achieving multipoint and patterned illumination, for example, with tapered fibers17 or patterned photostimulation.18,19 These methods do not allow the coupling of electrophysiology devices in close proximity and are not scalable. Michigan neural probes have shown the feasibility of integrating both types of sensors and of scaling the device size.2 In fact, the shank of such devices can be miniaturized (tip widths larger than decrease the quality of recordings)20 while the sensor density can be increased (to interface simultaneously larger number of neurons).21 Current electro-optical in vivo experiments rely on illuminating a broad neural population by integrating micro-LEDs next to electrodes22 or by coupling the probe with waveguides.8 All these methods present issues, such as heat generation23 (for micro-LEDs), and the resulting shanks cannot be scaled (due to the large size of the shown micro-LEDs and waveguides). Interesting and scalable photonic probes with silicon nitride waveguides have been proposed in Refs. 6 and 24 but only the photonic part has been shown. In this paper, we propose a fabrication method to integrate arbitrarily designed optical and electronic circuits on a single device. In this regard, we fabricate probes with electronic circuits. Separately, we fabricate photonic probes with similar substrate and fabrication techniques used for fabricating the electronic probe. To interface complex neural networks with a high density of sensors and minimized tissue damage, we first developed Michigan neural probes with minimal shank dimensions ( width and thickness) and, to the best of our knowledge, the highest presented density of electrodes and interconnections for a single-layer probe (64 electrodes, 120-nm wide interconnecting wire). To gain precise control of few neural cells during in vivo experiments, a micrometric spatial confinement of light is necessary. Our optical probes can focus light above the device plane, due to the use of a focusing grating. The result consists of a light cone, which allows having the maximum of light intensity far from the shank, where neuron density is reduced due to device insertion.25 Finally, we show that both electrical and optical probe versions have similar substrate and most of the fabrication processes. These fabrication techniques show the viability of fabricating a neural probe that is multifunctional, with minimal shank dimensions and high density of sensors, and can focus light deep in brain tissue.- 30 June 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanolithography, MEMS, and MOEMS
- Vol. 17 (02) , 025503-8
Open AccessHigh-density electrical and optical probes for neural readout and light focusing in deep brain tissue
One of the main goals of the Brain Research through Advancing Innovative Neurotechnologies (BRAIN) Initiative 1 is to map the brain at the single neuron and synapse level to understand how neural communication drives behavior and affects brain disorders. Nanotechnology has opened new pathways to interface single brain cells in vivo in brain tissue due to dimensions comparable to neural cells and the feasibility of integration of different types of sensors. In particular, Michigan neural probes are invasive devices built on a silicon (or polymeric) substrate.2 Michigan neural probes allow the use of micro and nanofabrication techniques (which imply high yield, low defectivity, and scalability) and integrate a high density of arrays of sensors (density limited mainly by the lithography resolution). The main element of these type of brain–machine interfaces is a sharp silicon tip (the shank) that is inserted into the animal’s brain and which contains passive or active sensors [electrodes,3,4 microfluidic channels,5 optical diffraction gratings,6 and micro-light-emitting diodes (LEDs)7]. Sensors on the shank are connected, due to metallic interconnections, waveguides, or microfluidic channels, to an extracranial device region having bond pads,8 optical coupling gratings, or fluidic interfaces.5 Many in vivo neuroscience studies employ Michigan neural probes to record or stimulate neurons by means of different types of techniques. Among these, invasive electrophysiology measurements (performed due to electrodes on the device’s shank) provide information on cortical circuit communication around the device through the recording of extracellular potentials.9 Another technique, optogenetics, uses light to manipulate neural population activity. Specific types of neurons are genetically modified by the introduction of opsins in the brain using viral vectors or anatomical targeting strategies.10,11 Channelrhodopsins are light-sensitive proteins that are able to enhance or inhibit neural population activity in the presence of light with the correct wavelength (around 450 to 473 nm).12 Different studies involving the manipulation of neural populations using optogenetic tools have shown promising future applications in brain disorders research.13,14 The simultaneous use of both electrophysiology and optogenetics in the same experiment is a necessary step to evolve neuroscience experiments.15,16 Different methods allow achieving multipoint and patterned illumination, for example, with tapered fibers17 or patterned photostimulation.18,19 These methods do not allow the coupling of electrophysiology devices in close proximity and are not scalable. Michigan neural probes have shown the feasibility of integrating both types of sensors and of scaling the device size.2 In fact, the shank of such devices can be miniaturized (tip widths larger than decrease the quality of recordings)20 while the sensor density can be increased (to interface simultaneously larger number of neurons).21 Current electro-optical in vivo experiments rely on illuminating a broad neural population by integrating micro-LEDs next to electrodes22 or by coupling the probe with waveguides.8 All these methods present issues, such as heat generation23 (for micro-LEDs), and the resulting shanks cannot be scaled (due to the large size of the shown micro-LEDs and waveguides). Interesting and scalable photonic probes with silicon nitride waveguides have been proposed in Refs. 6 and 24 but only the photonic part has been shown. In this paper, we propose a fabrication method to integrate arbitrarily designed optical and electronic circuits on a single device. In this regard, we fabricate probes with electronic circuits. Separately, we fabricate photonic probes with similar substrate and fabrication techniques used for fabricating the electronic probe. To interface complex neural networks with a high density of sensors and minimized tissue damage, we first developed Michigan neural probes with minimal shank dimensions ( width and thickness) and, to the best of our knowledge, the highest presented density of electrodes and interconnections for a single-layer probe (64 electrodes, 120-nm wide interconnecting wire). To gain precise control of few neural cells during in vivo experiments, a micrometric spatial confinement of light is necessary. Our optical probes can focus light above the device plane, due to the use of a focusing grating. The result consists of a light cone, which allows having the maximum of light intensity far from the shank, where neuron density is reduced due to device insertion.25 Finally, we show that both electrical and optical probe versions have similar substrate and most of the fabrication processes. These fabrication techniques show the viability of fabricating a neural probe that is multifunctional, with minimal shank dimensions and high density of sensors, and can focus light deep in brain tissue.