PPPatrick Poulet

Patrick Poulet

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Patrick Poulet has a total of 142 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A palm-sized high-sensitivity near-infrared fluorescence imager for laparotomy surgery

    by Paul Dorval, Norman Mangeret, Stephanie Guillermet, Ihab Atallah, Christian Righini, Gabriele Barabino, Jean-Luc Coll, Philippe Rizo, Patrick Poulet


  • Patent Blue Derivatized Dendronized Iron Oxide Nanoparticles for Multimodal Imaging

    by Lai Truong‐Phuoc, Marie Kueny‐Stotz, Julien Jouhannaud, Antonio Garofalo, François‐Xavier Blé, Hervé Simon, Franklin Tellier, Patrick Poulet, Piero Chirco, Sylvie Begin‐Colin, et al.

    Dendronized nanoparticles were designed for the bimodal (optical and magnetic) detection of lymph nodes with a hand‐held probe during surgery. Patent Blue VF dye and iron oxide nanoparticles with 20 nm diameter, displaying high magnetization and located at the superparamagnetic/blocked monodomain boundary, were associated through a dendritic PEGylated coating to obtain stable water suspensions. Conjugation procedures (the sulfonamide link formed between the PEGylated dendron and the dye, together with the phosphonate anchoring on the iron oxide surface) were shown to be strong enough to survive in vivo conditions when the prepared nanohybrids were tested in an inflammatory node model. Moreover, magnetization of 20 nm nanoparticles increased when dendrons were grafted onto the surface, showing that they are good candidates for magnetic particle imaging, which requires high magnetization values. Preliminary lymphatic node uptake experiments performed in an inflammatory animal model showed higher uptake of the 10 nm nanoparticles relative to that of 20 nm nanoparticles. The highest probe concentration was reached 2 d after injection.

  • The Fluostick, a real hand-held system for near-infrared fluorescence image-guided surgery

    by Paul Dorval, Norman Mangeret, Stephanie Guillermet, Christian Adrien Righini, Gabriele Barabino, Philippe Rizo, Patrick Poulet


  • Sentinel lymph nodes detection with an imaging system using Patent Blue V dye as fluorescent tracer

    by F. Tellier, J. Steibel, R. Chabrier, J. F. Rodier, G. Pourroy, P. Poulet

    Sentinel lymph node biopsy is the gold standard to detect metastatic invasion from primary breast cancer. This method can help patients avoid full axillary chain dissection, thereby decreasing the risk of morbidity. We propose an alternative to the traditional isotopic method, to detect and map the sentinel lymph nodes. Indeed, Patent Blue V is the most widely used dye in clinical routine for the visual detection of sentinel lymph nodes. A Recent study has shown the possibility of increasing the fluorescence quantum yield of Patent Blue V, when it is bound to human serum albumin. In this study we present a preclinical fluorescence imaging system to detect sentinel lymph nodes labeled with this fluorescent tracer. The setup is composed of a black and white CCD camera and two laser sources. One excitation source with a laser emitting at 635 nm and a second laser at 785 nm to illuminate the region of interest. The prototype is operated via a laptop. Preliminary experiments permitted to determine the device sensitivity in the μmol.L-1 range as regards the detection of PBV fluorescence signals. We also present a preclinical evaluation performed on Lewis rats, during which the fluorescence imaging setup detected the accumulation and fixation of the fluorescent dye on different nodes through the skin.

  • A time-gated near-infrared spectroscopic imaging device for clinical applications.

    by Patrick Poulet, Wilfried Uhring, Walter Hanselmann, René Glazenborg, Farouk Nouizi, Virginie Zint, Werner Hirschi

    A time-resolved, spectroscopic, diffuse optical tomography device was assembled for clinical applications like brain functional imaging. The entire instrument lies in a unique setup that includes a light source, an ultrafast time-gated intensified camera and all the electronic control units. The light source is composed of four near infrared laser diodes driven by a nanosecond electrical pulse generator working in a sequential mode at a repetition rate of 100 MHz. The light pulses are less than 80 ps FWHM. They are injected in a four-furcated optical fiber ended with a frontal light distributor to obtain a uniform illumination spot directed towards the head of the patient. Photons back-scattered by the subject are detected by the intensified CCD camera. There are resolved according to their time of flight inside the head. The photocathode is powered by an ultrafast generator producing 50 V pulses, at 100 MHz and a width corresponding to a 200 ps FWHM gate. The intensifier has been specially designed for this application. The whole instrument is controlled by an FPGA based module. All the acquisition parameters are configurable via software through an USB plug and the image data are transferred to a PC via an Ethernet link. The compactness of the device makes it a perfect device for bedside clinical applications. The instrument will be described and characterized. Preliminary data recorded on test samples will be presented.


  • Open Access

    Sentinel lymph nodes fluorescence detection and imaging using Patent Blue V bound to human serum albumin

    by Franklin Tellier, Jérôme Steibel, Renée Chabrier, François Xavier Blé, Hervé Tubaldo, Ravelo Rasata, Jacques Chambron, Guy Duportail, Hervé Simon, Jean-François Rodier, et al.

    Patent Blue V (PBV), a dye used clinically for sentinel lymph node detection, was mixed with human serum albumin (HSA). After binding to HSA, the fluorescence quantum yield increased from 5 × 10−4 to 1.7 × 10−2, which was enough to allow fluorescence detection and imaging of its distribution. A detection threshold, evaluated in scattering test objects, lower than 2.5 nmol × L−1 was obtained, using a single-probe setup with a 5-mW incident light power. The detection sensitivity using a fluorescence imaging device was in the µmol × L−1 range, with a noncooled CCD camera. Preclinical evaluation was performed on a rat model and permitted to observe inflamed nodes on all animals.


  • 200 ps FWHM and 100 MHz repetition rate ultrafast gated camera for optical medical functional imaging

    by Wilfried Uhring, Patrick Poulet, Walter Hanselmann, René Glazenborg, Virginie Zint, Farouk Nouizi, Benoit Dubois, Werner Hirschi

    The paper describes the realization of a complete optical imaging device to clinical applications like brain functional imaging by time-resolved, spectroscopic diffuse optical tomography. The entire instrument is assembled in a unique setup that includes a light source, an ultrafast time-gated intensified camera and all the electronic control units. The light source is composed of four near infrared laser diodes driven by a nanosecond electrical pulse generator working in a sequential mode at a repetition rate of 100 MHz. The resulting light pulses, at four wavelengths, are less than 80 ps FWHM. They are injected in a four-furcated optical fiber ended with a frontal light distributor to obtain a uniform illumination spot directed towards the head of the patient. Photons back-scattered by the subject are detected by the intensified CCD camera; there are resolved according to their time of flight inside the head. The very core of the intensified camera system is the image intensifier tube and its associated electrical pulse generator. The ultrafast generator produces 50 V pulses, at a repetition rate of 100 MHz and a width corresponding to the 200 ps requested gate. The photocathode and the Micro-Channel-Plate of the intensifier have been specially designed to enhance the electromagnetic wave propagation and reduce the power loss and heat that are prejudicial to the quality of the image. The whole instrumentation system is controlled by an FPGA based module. The timing of the light pulses and the photocathode gating is precisely adjustable with a step of 9 ps. All the acquisition parameters are configurable via software through an USB plug and the image data are transferred to a PC via an Ethernet link. The compactness of the device makes it a perfect device for bedside clinical applications.


  • Improvement of absorption and scattering discrimination by selection of sensitive points on temporal profile in diffuse optical tomography

    by Farouk Nouizi, Murielle Torregrossa, Renee Chabrier, Patrick Poulet

    We present a new method allowing the reconstruction of 3D time-domain diffuse optical tomography images, based on the time-dependent diffusion equation and an iterative algorithm (ART) using specific points on the temporal profiles. The first advantage of our method versus the full time-resolved scheme consists in considerably reducing the inverse problem resolution time. Secondly, in the presence of scattering heterogeneities, our method provides images of better quality comparatively to classical methods using full-time data or the first moments of the profiles.


  • Comparison of 2- and 4-wavelength methods for the optical detection of sentinel lymph node

    by F. Tellier, H. Simon, F. X. Blé, R. Ravelo, R. Chabrier, J. Steibel, J. F. Rodier, P. Poulet

    Sentinel lymph node biopsy is the gold standard method to detect a metastatic invasion from the primary breast cancer. This method can avoid patients to be submitted to full axillary chain dissection. In this study we present and compare two near-infrared optical probes for the sentinel lymph node detection, based on the recording of scattered photons. The two setups were developed to improve the detection of the dye injected in clinical routine: the Patent Blue V dye. Herein, we present results regarding clinical ex-vivo detection of sentinel lymph node after different volume injections. We have previously published results obtained with a two-wavelength probe on phantom and animal models. However this first generation device did not completely account for the optical absorption variations from biological tissue. Thus, a second generation probe has been equipped with four wavelengths. The dye concentration computation is then more robust to measurement and tissue property fluctuations. The detection threshold of the second setup was estimated at 8.10-3μmol/L, which is about 37 times lower than the eye visibility threshold. We present here the preliminary results and demonstrate the advantages of using four wavelengths compared to two on phantom suspensions simulating the optical properties of breast tissues.


  • 3D modeling of noncontact fiber-based approach for time-resolved diffuse optical tomography

    by F. Nouizi, M. Torregrossa, O. Geneveaux, R. Chabrier, P. Poulet

    We developed a time-resolved diffuse optical tomography system that enables performing noncontact 3D-DOT measurements of irregular shapes which is appropriate for small animal imaging. To retrieve the surface mesh, a noncontact holographic setup using a sensor and an XY optical scanning system was used. We present a noncontact modeling approach that consists in computing the temporal intensity distribution of detected photons taking into account the free space propagation from, and to, the fibers disposed around the studied object at some distance from its surface. The optimization was performed once on the time-weighted moments then on some points of the temporal profiles.© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.