Robert Skorek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert Skorek has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Rafal Sitko
Institute of Chemistry, University of Silesia, Szkolna 9, 40-006 Katowice, Poland
5 shared publications - Beata Zawisza
Institute of Chemistry, University of Silesia, Katowice, Poland
4 shared publications - Ignasi Queralt
Department of Geosciences, IDAEA-CSIC, Jordi Girona 18-26, 08034 Barcelona, Spain
3 shared publications Andrzej Kita
Department of Analytical Chemistry, Institute of Chemistry, University of Silesia, 40-006, Katowice, Poland
2 shared publications- Eva Marguí
University of Girona
2 shared publications Piotr Janoska
Department of Probability Theory, Institute of Mathematics, University of Silesia, 40-007, Katowice, Poland
2 shared publications
Latest Publications
- Open Access
- 27 February 2013
- Published by Walter de Gruyter GmbH in Open Chemistry
- Vol. 11 (5) , 742-753
A study on adsorption of metals by activated carbon in a large-scale (municipal) process of surface water purification
Elements that enter the aquatic environment may pose a health risk to wildlife and humans. The aims of this study were: to determine how the introduction of activated carbon for a water purification system will improve the quality of the water produced; and to investigate the sorption of metals on activated carbons, including determination of the accumulation, as well as changes in concentrations of elements in carbons. The tests were carried out on three types of activated carbons with different granular structure. All samples were collected from Water Treatment Plant Goczalkowice, Poland. Concentrations of elements were measured using an optical emission spectrometer with inductively coupled plasma. The experiment showed that metals accumulating in the activated carbons during the operation included: Ca, Mn, Zn, and Cu. In each of the three types of carbons, it can distinguish such elements as Ba, Al, Cr, Ni, Ti, which are characterized by irregular accumulation during the operation of the filter. The introduction of carbon sorbent for water treatment largely contributed to improvement in the quality of raw material supplied to customers, mainly with regard to taste and smell, as well as to reduction of basic parameters: color, absorbance in the UV range and oxidability.
- 27 February 2013
- Published by Walter de Gruyter GmbH in Open Chemistry
- Vol. 11 (5) , 742-753
Open AccessA study on adsorption of metals by activated carbon in a large-scale (municipal) process of surface water purification
Elements that enter the aquatic environment may pose a health risk to wildlife and humans. The aims of this study were: to determine how the introduction of activated carbon for a water purification system will improve the quality of the water produced; and to investigate the sorption of metals on activated carbons, including determination of the accumulation, as well as changes in concentrations of elements in carbons. The tests were carried out on three types of activated carbons with different granular structure. All samples were collected from Water Treatment Plant Goczalkowice, Poland. Concentrations of elements were measured using an optical emission spectrometer with inductively coupled plasma. The experiment showed that metals accumulating in the activated carbons during the operation included: Ca, Mn, Zn, and Cu. In each of the three types of carbons, it can distinguish such elements as Ba, Al, Cr, Ni, Ti, which are characterized by irregular accumulation during the operation of the filter. The introduction of carbon sorbent for water treatment largely contributed to improvement in the quality of raw material supplied to customers, mainly with regard to taste and smell, as well as to reduction of basic parameters: color, absorbance in the UV range and oxidability.
- 1 February 2013
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 67 (2) , 204-209
Dispersive Micro Solid-Phase Extraction Using Multiwalled Carbon Nanotubes for Simultaneous Determination of Trace Metal Ions by Energy-Dispersive X-ray Fluorescence Spectrometry
A methodology based on dispersive micro solid-phase extraction (DMSPE) using multiwalled carbon nanotubes (MWCNTs) as solid sorbent prior to measurement with energy-dispersive X-ray fluorescence (EDXRF) spectrometry is proposed. The procedure consists of chelating of nickel, cobalt, copper, and lead ions with ammonium pyrrolidinedi-thiocarbamate (APDC) and posterior adsorption of metal chelates on MWCNTs (1 mg) dispersed in the aqueous samples (100 mL). DMSPE promotes immediate interaction between the metal chelates and MWCNTs and shortens time of sample preparation in comparison with classical solid-phase extraction. After microextraction process, MWCNTs are collected onto filter and directly measured by EDXRF. With this technique, the direct quantification of metal species held in solid materials is possible and, therefore, the elution step can be avoided. The effects of various experimental parameters such as pH of the solution, amounts of MWCNTs and APDC, sample volume, and time of stirring were investigated. With the best analytical conditions (1 mg of MWCNTs, 2 mg of APDC, 100 mL sample volume, pH = 7, and 5 min time of stirring), Co(II), Ni(II), Cu(II), and Pb(II) can be simultaneously determined with very good recoveries (101%, 98%, 96%, 99%, respectively) and detection limits (0.43, 0.11, 0.46, 0.15 ng mL−1, respectively). The method was applied in determination of trace metal ions in tap water and wastewater samples.
- 1 February 2013
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 67 (2) , 204-209
Dispersive Micro Solid-Phase Extraction Using Multiwalled Carbon Nanotubes for Simultaneous Determination of Trace Metal Ions by Energy-Dispersive X-ray Fluorescence Spectrometry
A methodology based on dispersive micro solid-phase extraction (DMSPE) using multiwalled carbon nanotubes (MWCNTs) as solid sorbent prior to measurement with energy-dispersive X-ray fluorescence (EDXRF) spectrometry is proposed. The procedure consists of chelating of nickel, cobalt, copper, and lead ions with ammonium pyrrolidinedi-thiocarbamate (APDC) and posterior adsorption of metal chelates on MWCNTs (1 mg) dispersed in the aqueous samples (100 mL). DMSPE promotes immediate interaction between the metal chelates and MWCNTs and shortens time of sample preparation in comparison with classical solid-phase extraction. After microextraction process, MWCNTs are collected onto filter and directly measured by EDXRF. With this technique, the direct quantification of metal species held in solid materials is possible and, therefore, the elution step can be avoided. The effects of various experimental parameters such as pH of the solution, amounts of MWCNTs and APDC, sample volume, and time of stirring were investigated. With the best analytical conditions (1 mg of MWCNTs, 2 mg of APDC, 100 mL sample volume, pH = 7, and 5 min time of stirring), Co(II), Ni(II), Cu(II), and Pb(II) can be simultaneously determined with very good recoveries (101%, 98%, 96%, 99%, respectively) and detection limits (0.43, 0.11, 0.46, 0.15 ng mL−1, respectively). The method was applied in determination of trace metal ions in tap water and wastewater samples.
- 10 August 2012
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 27 (10) , 1688-1693
Determination of selenium by X-ray fluorescence spectrometry using dispersive solid-phase microextraction with multiwalled carbon nanotubes as solid sorbent
A dispersive solid-phase microextraction (DSPME) with multiwalled carbon nanotubes (MWCNTs) as solid sorbent and ammonium pyrrolidinedithiocarbamate (APDC) as chelating agent was developed for determination of selenium. In the proposed procedure, the Se(IV)–APDC complex is adsorbed on MWCNTs dispersed in aqueous samples. After the adsorption process, the aqueous samples are filtered and MWCNTs with selenium chelate are collected onto a filter. The loaded filters are directly measured using X-ray fluorescence (XRF) spectrometry. In order to obtain high recovery of the Se ions on MWCNTs, the proposed procedure was optimized for various analytical parameters such as pH, amounts of MWCNTs and APDC, sample volume and time of the sorption process. Under optimized conditions Se ions can be determined with very good recovery (97 ± 3%), precision (RSD = 3.2%) and detection limits (from 0.06 to 0.2 ng mL−1, depending on counting time and XRF equipment). The effect of common coexisting ions was also investigated. Se(IV) can be determined in the presence of heavy metal ions and alkali metals. The chemical interferences observed for high concentrations of Cu(II), Fe(III), and Zn(II) can be completely eliminated using precipitation with NaOH. The proposed method was applied for the determination of Se in mineral water and biological samples (Lobster Hepatopancreas). The proposed method can also be applied for selenium speciation. The concentration of selenate can be obtained as the difference between the concentration of selenite after and before prereduction of selenate to selenite.
- 10 August 2012
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 27 (10) , 1688-1693
Determination of selenium by X-ray fluorescence spectrometry using dispersive solid-phase microextraction with multiwalled carbon nanotubes as solid sorbent
A dispersive solid-phase microextraction (DSPME) with multiwalled carbon nanotubes (MWCNTs) as solid sorbent and ammonium pyrrolidinedithiocarbamate (APDC) as chelating agent was developed for determination of selenium. In the proposed procedure, the Se(IV)–APDC complex is adsorbed on MWCNTs dispersed in aqueous samples. After the adsorption process, the aqueous samples are filtered and MWCNTs with selenium chelate are collected onto a filter. The loaded filters are directly measured using X-ray fluorescence (XRF) spectrometry. In order to obtain high recovery of the Se ions on MWCNTs, the proposed procedure was optimized for various analytical parameters such as pH, amounts of MWCNTs and APDC, sample volume and time of the sorption process. Under optimized conditions Se ions can be determined with very good recovery (97 ± 3%), precision (RSD = 3.2%) and detection limits (from 0.06 to 0.2 ng mL−1, depending on counting time and XRF equipment). The effect of common coexisting ions was also investigated. Se(IV) can be determined in the presence of heavy metal ions and alkali metals. The chemical interferences observed for high concentrations of Cu(II), Fe(III), and Zn(II) can be completely eliminated using precipitation with NaOH. The proposed method was applied for the determination of Se in mineral water and biological samples (Lobster Hepatopancreas). The proposed method can also be applied for selenium speciation. The concentration of selenate can be obtained as the difference between the concentration of selenite after and before prereduction of selenate to selenite.
- Open Access
- 1 February 2012
- Published by Walter de Gruyter GmbH in Open Chemistry
- Vol. 10 (1) , 71-84
Application of ICP-MS and various computational methods for drinking water quality assessment from the Silesian District (Southern Poland)
In this study, more than 200 samples of drinking water from taps in the Silesian District (southern Poland) were analyzed. Concentrations of As, Bi, Cd, Co, Cr, Mo, Ni, Pb, Rb, Sb, Se, Te, Tl and V were measured using inductively coupled plasma-mass spectrometry technique (ICP-MS). The levels of the tested elements generally met European Union regulations. All analytical results were processed using computational methods, including the Pearson and Gini coefficients with the Lorenz curves, one-way ANOVA, the Kruskal-Wallis one-way analysis of variance, the Mann-Whitney U test, the variance correlation test and the Spearman’s test. In addition, Principal Component Analysis (PCA) with Varimax and Cluster Analysis with Ward’s Method were applied. It was shown, that some parameters (e.g. hardness and alkalinity) were highly correlated. The score plot described the degree of mineralization of water samples, so the origin of water could be easily determined. In turn, based on the created dendrogram, the division of samples into several groups (with soft, medium and highly mineralized water) could be deduced.
- 1 February 2012
- Published by Walter de Gruyter GmbH in Open Chemistry
- Vol. 10 (1) , 71-84
Open AccessApplication of ICP-MS and various computational methods for drinking water quality assessment from the Silesian District (Southern Poland)
In this study, more than 200 samples of drinking water from taps in the Silesian District (southern Poland) were analyzed. Concentrations of As, Bi, Cd, Co, Cr, Mo, Ni, Pb, Rb, Sb, Se, Te, Tl and V were measured using inductively coupled plasma-mass spectrometry technique (ICP-MS). The levels of the tested elements generally met European Union regulations. All analytical results were processed using computational methods, including the Pearson and Gini coefficients with the Lorenz curves, one-way ANOVA, the Kruskal-Wallis one-way analysis of variance, the Mann-Whitney U test, the variance correlation test and the Spearman’s test. In addition, Principal Component Analysis (PCA) with Varimax and Cluster Analysis with Ward’s Method were applied. It was shown, that some parameters (e.g. hardness and alkalinity) were highly correlated. The score plot described the degree of mineralization of water samples, so the origin of water could be easily determined. In turn, based on the created dendrogram, the division of samples into several groups (with soft, medium and highly mineralized water) could be deduced.