SBSiobhan Brennan

Siobhan Brennan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Siobhan Brennan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The importance of hearing: a review of the literature on hearing loss for older people with learning disabilities

    by Sarah Bent, Lynzee McShea, Siobhan Brennan

    Accessible summary: It is important to be aware of hearing loss as it affects everyday life and gets worse with age in all adults. Many people with learning disabilities do not have their hearing checked, and families or carers often struggle to notice hearing problems. This study summarises previous research on hearing loss and old age for people with learning disabilities. Large numbers of older people with learning disabilities were found to have hearing problems, but smaller numbers were aware of this before testing. Everyone with learning disabilities should be aware of how important hearing is and have regular checks, especially before they reach old age. Background: Hearing loss has a significant impact on living well and on communication in all adults, with the numbers affected increasing with age, and adults with learning disabilities being at particular risk.Methods: A review of the literature on hearing loss in older adults with learning disabilities was completed.Results: A significant increase in hearing loss with increasing age in this group was demonstrated, at a greater level than in the general population. Prevalence rates have been the main focus of research, with few considerations of access to hearing assessment or benefits of rehabilitation such as hearing aids, or the effect that age has on living with hearing loss.Conclusions: With advances in audiology services and increased life expectancy of those with learning disabilities, further research would be valuable. In addition, all health and social care services should consider actively promoting hearing assessment and rehabilitation. Individuals, carers and families should also take action, not only when concerns around memory arise, but proactively for all.


  • Hearing problems in the learning disability population: is anybody listening?

    by Alex McClimens, Siobhan Brennan, Pauline Hargreaves

    Accessible summary: people with learning disability tend to have more hearing problems than other people. often these hearing problems are not picked up by doctors, nurses, carers or even by the people themselves. living with undetected hearing loss means people miss out on information, social opportunities and entertainment. routine screening for hearing loss would improve the lives of many people with learning disability. Summary: We undertook this project because we believed that hearing loss experienced by the target population was greater than the referral figures suggested. Therefore, we set up a trial service initiative designed to examine the efficacy of different referral routes into audiology services for adults with learning disability. This retrospective analysis focuses on the generation of data on hearing loss on a small population sample (n = 136) gathered over a 6‐month period in 2012. We suggest remedial action now to prevent more problems in the future.


  • ABR in newborns: Effects of electrode configuration, stimulus rate, and EEG rejection levels on test efficiency

    by John Stevens, Siobhan Brennan, Denise Gratton, Michael Campbell

    Objective: This study investigated the effect of electrode configuration, stimulus rate, and EEG rejection level on the efficiency of ABR testing in babies. Design: ABR to click stimuli at 40 dB nHL were simultaneously recorded from two electrode configurations, ipsilateral mastoid to high forehead (Mi-Fh) and nape to high forehead (N-Fh), with two EEG rejection levels (± 5 μV and ± 10 μV). Stimulus rates were between 39.1 and 69.1 per second. Efficiency was measured by confidence in the ABR for a given test time. Study sample: Thirty babies who had passed a targeted newborn hearing screen with ABR thresholds ≤ 40 dB nHL. Results: The N-Fh configuration, as expected, gave on average a larger response amplitude compared to the Mi-Fh configuration but was only marginally significantly better in terms of test efficiency. There was no significant effect of stimulus rate on test efficiency between 39.1/s and 59.1/s. The lower ± 5 μV EEG rejection level was more test efficient. Conclusions: This study provides some evidence that, for ABR threshold testing in babies, alternatives of ipsilateral mastoid or nape electrode and a range of stimulus rates have little or no effect on test efficiency. The results support the use of low EEG rejection limits.


  • Intra and intersubject variability in auditory steady-state response amplitude with high modulation rates to 1000 Hz amplitude modulated and tone pip stimuli

    by Michelle Foster, John Stevens, Siobhan Brennan

    Objective: This study set out to provide further information on how high modulation/stimulus rates affect the auditory steady-state response (ASSR) amplitude for a 1000-Hz tone, and how this effect varies between individuals. Both sinusoidal amplitude modulated tones and tone pip stimuli were investigated. Design: Modulation/stimulus rates were 70, 80, and 90 Hz and the peak to peak stimulus levels were matched for the two different types of stimuli, at 90.5 dBSPLppe. Study sample: The study was carried out on fourteen normally-hearing adults (9 males and 5 females) Results: Overall the ASSR amplitude to the two types of stimuli was similar. In general there was an increasing response amplitude between rates of 70 and 90 Hz; The relationship between the amplitude of the response and the modulation /stimulus rate varied considerably between subjects. Conclusions: Optimum stimulus rates based on group data may not give the best rate in a significant proportion of subjects. Currently tone pip ABR is the primary method used in assessing hearing in babies. Finding a way of avoiding suboptimal stimulus rates for ‘80-Hz’ ASSR in babies will improve the likelihood of ASSR being seen as an alternative.


  • The effect of varying stimulus phase between frequency and amplitude modulation on auditory steady-state responses in neonates

    by Siobhán K. Brennan, Ruth E. Brooke, John C. Stevens

    Objective: To compare auditory steady-state responses (ASSRs) to air-conducted amplitude, frequency, and mixed modulated stimuli (AM, FM, and MM, respectively) in neonates. Design: Multiple ASSRs to AM, FM, and MM to 0.5, 1, 2, and 4 kHz tones modulated between 0.078 and 0.092 kHz were recorded and compared. MM phase settings across the cycle at 45° intervals were used and optimum phase settings were predicted using a sinusoidal model. Study sample: Twenty neonates with click ABR thresholds of ≤ 40 dB nHL. Results: ASSR amplitudes were significantly larger to AM than FM stimuli. MM phase setting had a significant effect on amplitude at 1, 2, and 4 kHz but not 0.5 kHz. MM phase settings (± 95% confidence intervals) of 276° (± 9.5°) and 270° (± 19.1°) were predicted for 1 and 2 kHz, respectively. The 0.5 and 4 kHz data were not sufficient to model any effect of phase. MM and AM response latencies increased with decreasing carrier frequency. Some MM response latencies were significantly different from AM response latencies, however no consistent trend was apparent. Test times were significantly affected by phase setting. Conclusions: MM phase settings have a significant effect on ASSR response amplitude and latencies in neonates.


  • Effect of Varying Phase Between Frequency and Amplitude Modulation on Bone Conduction Auditory Steady State Responses

    by Siobhán K. Brennan, Ruth E. Brooke, John C. Stevens, Brian H. Brown

    Auditory steady state response (ASSR) testing provides a means to objectively estimate hearing levels in newborns and adults for whom behavioral tests prove difficult. When testing these patient groups, it is preferable that clear responses to both air and bone conduction stimuli are obtained in a short amount of time. Much of the literature addressing ASSRs, such as investigations of stimulus and recording parameters, have focused on air conduction ASSRs. The aim of this investigation was to study the amplitudes, latencies, and test times of bone conduction ASSRs elicited using amplitude- (AM), frequency- (FM), and mixed-modulated (MM) stimuli and provide suggestions for optimum recording parameters. Bone and air conduction multiple ASSRs were recorded from two groups of 20 normal-hearing adults using the Multiple Auditory Steady State Response research system. AM, FM, and MM sinusoidal tones were used (0.5-, 1-, 2-, and 4-kHz carrier frequencies), which were modulated between 78 and 92 Hz. AM depth was 100% and FM depth was 20%. ASSR amplitudes and latencies (calculated using the "preceding cycles" technique) were analyzed for MM phase settings across the cycle from 0° at 45° intervals and compared with AM responses. Optimum phase settings for bone and air conduction ASSRs were calculated using a sinusoidal model based on the amplitude data. Similar effects of stimulus type and carrier frequency were observed for bone and air conduction ASSRs. AM responses were larger in amplitude compared with FM responses. MM (at all phase settings tested) and AM response latencies increased with decreasing carrier frequency. MM phase setting had a significant (p < 0.01) sinusoidal effect on ASSR amplitudes, compared with AM responses, at 1, 2, and 4 kHz but not 0.5 kHz for air conduction and 1 and 2 kHz but not 0.5 and 4 kHz for bone conduction. Using a sinusoidal function to model this effect, MM phase settings (±95% confidence intervals) of 318° (295 to 350°) and 295° (290 to 310°) are predicted to evoke the largest responses for bone conduction ASSRs at 1 and 2 kHz, respectively. Phase settings of 293° (285 to 310°), 300° (280 to 310°), and 280° (255 to 330°) are predicted for air conduction ASSRs at 1, 2, and 4 kHz, respectively. MM phase setting had little effect on estimated latency. Test times were significantly (p < 0.01) affected by phase setting with both increases and decreases being observed. Test times for ASSRs at 1, 2, and 4 kHz could be significantly reduced if the estimated optimum phase settings are used. Different stimuli can significantly affect the amplitudes of bone conduction ASSRs. These effects are similar to those observed for air conduction ASSRs. MM stimuli with specific phase settings evoke larger bone conduction ASSRs compared with AM and FM stimuli alone, and calculations show that the time taken to obtain these responses is reduced. Implementation of the suggested optimum settings will promote efficient collection of bone conduction, and indeed air conduction, ASSR data.


  • Bone Conduction Auditory Steady State Response: Investigations into Reducing Artifact

    by Ruth Elizabeth Brooke, Siobhan Katharine Brennan, John Chester Stevens

    Objectives: Auditory steady state responses (ASSRs) can be reliably recorded in sleeping neonates and can be used to estimate hearing thresholds in individuals with normal or impaired hearing. However, artifactual responses can contaminate recordings, particularly when recording bone conduction ASSRs. The aim of this investigation was to study the presence of electromagnetic artifact in bone conduction ASSRs and to investigate methods of reducing the amplitude of the artifact. Design: Using a simulation of a patient, ASSR recordings were obtained to multiple frequency bone-conducted stimuli using the research MASTER system. ASSR stimuli were sinusoidal tones with the carrier frequencies 500, 1000, 2000, and 4000 Hz that were 100% amplitude modulated at 83, 87, 91, and 95 Hz, respectively. After the assessment of different equipment layouts, the effects of (1) altering the analog-to-digital conversion rates and (2) screening the transducer cable and B-71 transducer and connecting the screens to ground were investigated. Results: For ASSR recordings, artifacts were observed at the modulation rates of the 1000-, 2000-, and 4000-Hz carrier frequencies. As expected, the artifact was proportional to stimulus intensity and was observed when using sampling rates of 1000 and 2000 Hz but not 1250 and 1600 Hz. Altering the electrode lead/transducer cable layout and orientation of the B-71 transducer significantly affected the amplitude of the artifact. Screening of the B-71 transducer and cable and connecting the screens to ground reduced the amplitude of the artifact to a level that was not significantly above background noise. A mu-metal screen had a significantly greater effect than aluminum or copper. Conclusions: If stimulus artifact is present in the recorded EEG, for certain choices of carrier frequency and sampling rate it is possible to record artifactual signals at the same modulation rates as those used to elicit ASSRs. This is problematic as the artifact may then be misinterpreted as an ASSR response. The results from this study have demonstrated that careful attention to equipment layout, choice of sampling rate, using grounded screens to screen the B-71 transducer and transducer cable can all be effective in reducing the level of stimulus artifact.