Cristian Postolache
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cristian Postolache has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Viorel Fugaru
Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering (IFIN-HH), 30 Reactorului St., P.O. Box MG-6, 077125 Măgurele, Romania
4 shared publications - Lidia Matei
Horia Hulubei National Institute for Physics and Nuclear Engineering, Magurele, Bucharest, Romania
3 shared publications A. Antohe
Horia Hulubei National Institute for Physics and Nuclear Engineering, 30, Reactorului Street, Magurele, Ilfov, Romania
1 shared publicationAdrian Bucsa
Technol Nucl Energy Inst Nucl Res Pitesti, RATEN ICN, Campului St 1, Pitesti, Arges County, Romania
1 shared publication- Alexandru Petre
Horia Hulubei National Institute of Physics and Nuclear Engineering, 077125 Magurele, Romania
1 shared publication Andi Sebastian Cucoanes
“Horia Hulubei” National Institute of Nuclear Physics and Engineering, Bucharest
1 shared publication
Latest Publications
- 4 April 2022
- Published by National Research And Development Institute For Cryogenic And Isotopic Technologies in SMART ENERGY AND SUSTAINABLE ENVIRONMENT
- Vol. 25 (1) , 47-54
SYNTHESIS OF TRITIUM LABELLED THYMIDINE AND URIDINE
This study present tritium labeling methods for uridine and thymidine in the methyl position. The synthesis of tritiated thymidine has been performed using two different methods: catalytic hydrogenation of brominated derivative and respectively of hydroxymethyl deoxiuridine. The tritiated uridine has been synthesized by catalytic hydrogenation of 5-I Uridine. The labelled compounds were purified by Thin Layer Chromatography and characterized by determination of radioactive concentration, chemical concentration and radiochemical purities. The obtained tritiated thymidine and uridine have been used for in vitro studies for evaluation of radiation effects in cell cultures.
- 4 April 2022
- Published by National Research And Development Institute For Cryogenic And Isotopic Technologies in SMART ENERGY AND SUSTAINABLE ENVIRONMENT
- Vol. 25 (1) , 47-54
SYNTHESIS OF TRITIUM LABELLED THYMIDINE AND URIDINE
This study present tritium labeling methods for uridine and thymidine in the methyl position. The synthesis of tritiated thymidine has been performed using two different methods: catalytic hydrogenation of brominated derivative and respectively of hydroxymethyl deoxiuridine. The tritiated uridine has been synthesized by catalytic hydrogenation of 5-I Uridine. The labelled compounds were purified by Thin Layer Chromatography and characterized by determination of radioactive concentration, chemical concentration and radiochemical purities. The obtained tritiated thymidine and uridine have been used for in vitro studies for evaluation of radiation effects in cell cultures.
- Open Access
- 22 February 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (3) , 363
Recent Progress in Radon Metrology at IFIN-HH, Romania
The practical implementation of the European Council Directive no. 2013/59/EURATOM in Romania requires reliable indoor measurements of the radon (222Rn) activity concentration in air. In Romania, several Testing Laboratories were designated for radon activity and/or radon activity concentration in air measurements by the Romanian National Commission for Nuclear Activities Control (CNCAN). The calibration of the instruments used for indoor radon activity concentration measurements is very important. IFIN-HH, through its Ionizing Radiation Metrology Laboratory (LMRI), performed advanced research in the field of radon metrology, using radon standard sources prepared by LMRI, its radon chamber facility and a new reference radon monitor. The most recent results are described in this article. The radon chamber facility from IFIN-HH was technically improved, and new equipment and methods were set up and tested in order to provide new calibration services for customers. Additionally, calibration of the radon monitors was performed, as well as of the systems with solid-state nuclear track detectors, used for radon in air activity concentration measurements. IFIN-HH/LMRI obtained the CNCAN designation as Calibration Laboratory for installations measuring the radon activity concentration in air.
- 22 February 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (3) , 363
Open AccessRecent Progress in Radon Metrology at IFIN-HH, Romania
The practical implementation of the European Council Directive no. 2013/59/EURATOM in Romania requires reliable indoor measurements of the radon (222Rn) activity concentration in air. In Romania, several Testing Laboratories were designated for radon activity and/or radon activity concentration in air measurements by the Romanian National Commission for Nuclear Activities Control (CNCAN). The calibration of the instruments used for indoor radon activity concentration measurements is very important. IFIN-HH, through its Ionizing Radiation Metrology Laboratory (LMRI), performed advanced research in the field of radon metrology, using radon standard sources prepared by LMRI, its radon chamber facility and a new reference radon monitor. The most recent results are described in this article. The radon chamber facility from IFIN-HH was technically improved, and new equipment and methods were set up and tested in order to provide new calibration services for customers. Additionally, calibration of the radon monitors was performed, as well as of the systems with solid-state nuclear track detectors, used for radon in air activity concentration measurements. IFIN-HH/LMRI obtained the CNCAN designation as Calibration Laboratory for installations measuring the radon activity concentration in air.
- 23 March 2020
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 76 (3) , 202-208
Titanium Hydrides with Controlled H/T Ratio for AMS Facility Calibration
Annual tritium exposures can be reconstructed for long time periods by analyzing radioactive concentrations in tree rings near nuclear facilities that can release tritiated water (HTO) to the environment. Since the mass of analyzed samples is on the order of milligrams, usual methods such as liquid scintillation counting cannot be applied. The recommended method comprises thermal decomposition of the milligram-sized samples, reduction of the resulting HTO to tritiated hydrogen, quantitative absorption of titanium hydride (TiHT) in titanium powder, and determination of the H/T ratio using an accelerator mass spectrometer method. This paper describes the method for obtaining TiHT standards with different H/T isotopic ratios for calibration of a mass spectrometer detector.
- 23 March 2020
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 76 (3) , 202-208
Titanium Hydrides with Controlled H/T Ratio for AMS Facility Calibration
Annual tritium exposures can be reconstructed for long time periods by analyzing radioactive concentrations in tree rings near nuclear facilities that can release tritiated water (HTO) to the environment. Since the mass of analyzed samples is on the order of milligrams, usual methods such as liquid scintillation counting cannot be applied. The recommended method comprises thermal decomposition of the milligram-sized samples, reduction of the resulting HTO to tritiated hydrogen, quantitative absorption of titanium hydride (TiHT) in titanium powder, and determination of the H/T ratio using an accelerator mass spectrometer method. This paper describes the method for obtaining TiHT standards with different H/T isotopic ratios for calibration of a mass spectrometer detector.
- Open Access
- 1 November 2019
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 353
Characterization measurements of fluental and graphite in FiR1 TRIGA research reactor decommissioning waste
- 1 November 2019
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 353
Open AccessCharacterization measurements of fluental and graphite in FiR1 TRIGA research reactor decommissioning waste
- 22 January 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (3) , 431-436
3H and 14C measurements of the irradiated graphite from the decommissioned VVR-S reactor in NIPNE Bucharest
Accelerator Mass Spectrometry and Full Combustion method followed by liquid scintillation counting were applied to measure the accumulated 14C in the thermal column of the decommissioned VVR-S reactor in NIPNE Bucharest.
- 22 January 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (3) , 431-436
3H and 14C measurements of the irradiated graphite from the decommissioned VVR-S reactor in NIPNE Bucharest
Accelerator Mass Spectrometry and Full Combustion method followed by liquid scintillation counting were applied to measure the accumulated 14C in the thermal column of the decommissioned VVR-S reactor in NIPNE Bucharest.
- 3 April 2017
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 71 (3) , 286-289
Leaching Tests of the Tritium Waste Immobilized in New Cement Mixtures
The study was conducted in order to determine the immobilization performance of low-level tritium waste in new cement mixtures. The grouts analyzed are fine mortars, fluid, self- compacting, with flowability, able to fill the smallest gaps in the solid waste container. The grouts curing showed compact and structural integrity without pores and cracks, so as to ensure radioactive tritium waste encapsulation. Two types of solid/liquid tritium radioactive waste with known tritium activity have been prepared: one type containing a hydrophilic tritium compound and the other one a hydrophobic tritium compound. The tritium waste was mixed with three different types of grout and poured in a cylindrical mould. The leaching of tritium from waste solidified/encapsulated in the cement mixtures immersed in an aqueous environment has been studied in order to select the most appropriate grout type as waste immobilization matrix. Samples from the liquid surrounding the cements blocks were collected at predetermined time intervals and placed in the liquid scintillation cocktail and measured. The activity of the tritium released was then calculated.
- 3 April 2017
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 71 (3) , 286-289
Leaching Tests of the Tritium Waste Immobilized in New Cement Mixtures
The study was conducted in order to determine the immobilization performance of low-level tritium waste in new cement mixtures. The grouts analyzed are fine mortars, fluid, self- compacting, with flowability, able to fill the smallest gaps in the solid waste container. The grouts curing showed compact and structural integrity without pores and cracks, so as to ensure radioactive tritium waste encapsulation. Two types of solid/liquid tritium radioactive waste with known tritium activity have been prepared: one type containing a hydrophilic tritium compound and the other one a hydrophobic tritium compound. The tritium waste was mixed with three different types of grout and poured in a cylindrical mould. The leaching of tritium from waste solidified/encapsulated in the cement mixtures immersed in an aqueous environment has been studied in order to select the most appropriate grout type as waste immobilization matrix. Samples from the liquid surrounding the cements blocks were collected at predetermined time intervals and placed in the liquid scintillation cocktail and measured. The activity of the tritium released was then calculated.
- 22 February 2016
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 25 (3) , 035024
Radiation, temperature, and vacuum effects on piezoelectric wafer active sensors
The effect of radiation, temperature, and vacuum (RTV) on piezoelectric wafer active sensors (PWASs) is discussed. This study is relevant for extending structural health monitoring (SHM) methods to space vehicle applications that are likely to be subjected to harsh environmental conditions such as extreme temperatures (hot and cold), cosmic radiation, and interplanetary vacuums. This study contains both theoretical and experimental investigations with the use of electromechanical impedance spectroscopy (EMIS). In the theoretical part, analytical models of circular PWAS resonators were used to derive analytical expressions for the temperature sensitivities of EMIS resonance and antiresonance behavior. Closed-form expressions for frequency and peak values at resonance and antiresonance were derived as functions of the coefficients of thermal expansion, the Poisson ratio, and its sensitivity, the relative compliance gradient and the Bessel function root, and its sensitivity, In the experimental part, tests were conducted to subject the PWAS transducers to RTV conditions. In one set of experiments, several RTV exposure, cycles were applied with EMIS signatures recorded at the beginning and after each of the repeated cycles. In another set of experiments, PWAS transducers were subjected to various temperatures and the EMIS signatures were recorded at each temperature after stabilization. The processing of measured EMIS data from the first set of experiments revealed that the resonance and antiresonance frequencies changed by less than 1% due to RTV exposure, whereas the resonance and antiresonance amplitudes changed by around 15%. After processing an individual set of EMIS data from the second set of experiments, it was determined that the relative temperature sensitivity of the antiresonance frequency ( is approximately and the relative temperature sensitivity of the antiresonance amplitude (Re Z ) is approximately A tentative statistical analysis and comparative plots of the data from sets of PWAS transducers revealed that the trends observed on an individual PWAS are also observed on the entire set of PWAS transducers. The article concludes with a summary, conclusions, and suggestions for further work.
- 22 February 2016
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 25 (3) , 035024
Radiation, temperature, and vacuum effects on piezoelectric wafer active sensors
The effect of radiation, temperature, and vacuum (RTV) on piezoelectric wafer active sensors (PWASs) is discussed. This study is relevant for extending structural health monitoring (SHM) methods to space vehicle applications that are likely to be subjected to harsh environmental conditions such as extreme temperatures (hot and cold), cosmic radiation, and interplanetary vacuums. This study contains both theoretical and experimental investigations with the use of electromechanical impedance spectroscopy (EMIS). In the theoretical part, analytical models of circular PWAS resonators were used to derive analytical expressions for the temperature sensitivities of EMIS resonance and antiresonance behavior. Closed-form expressions for frequency and peak values at resonance and antiresonance were derived as functions of the coefficients of thermal expansion, the Poisson ratio, and its sensitivity, the relative compliance gradient and the Bessel function root, and its sensitivity, In the experimental part, tests were conducted to subject the PWAS transducers to RTV conditions. In one set of experiments, several RTV exposure, cycles were applied with EMIS signatures recorded at the beginning and after each of the repeated cycles. In another set of experiments, PWAS transducers were subjected to various temperatures and the EMIS signatures were recorded at each temperature after stabilization. The processing of measured EMIS data from the first set of experiments revealed that the resonance and antiresonance frequencies changed by less than 1% due to RTV exposure, whereas the resonance and antiresonance amplitudes changed by around 15%. After processing an individual set of EMIS data from the second set of experiments, it was determined that the relative temperature sensitivity of the antiresonance frequency ( is approximately and the relative temperature sensitivity of the antiresonance amplitude (Re Z ) is approximately A tentative statistical analysis and comparative plots of the data from sets of PWAS transducers revealed that the trends observed on an individual PWAS are also observed on the entire set of PWAS transducers. The article concludes with a summary, conclusions, and suggestions for further work.
- 30 April 2009
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 280 (2) , 251-258
Self-radiolytical processes in ethyl-phenyl siloxanes labeled with tritium
- 30 April 2009
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 280 (2) , 251-258
Self-radiolytical processes in ethyl-phenyl siloxanes labeled with tritium
- 1 April 2007
- Published by Wiley in Journal of Labelled Compounds and Radiopharmaceuticals
- Vol. 50 (5-6) , 609-610
Synthesis of [5‐3H]uracil nucleoside analogue
- 1 April 2007
- Published by Wiley in Journal of Labelled Compounds and Radiopharmaceuticals
- Vol. 50 (5-6) , 609-610
Synthesis of [5‐3H]uracil nucleoside analogue
- 1 April 2007
- Published by Wiley in Journal of Labelled Compounds and Radiopharmaceuticals
- Vol. 50 (5-6) , 444-445
Synthesis of [α‐T]polyacrylic acid
- 1 April 2007
- Published by Wiley in Journal of Labelled Compounds and Radiopharmaceuticals
- Vol. 50 (5-6) , 444-445
Synthesis of [α‐T]polyacrylic acid