Vladislav Pugachov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Vladislav Pugachov has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Svetlana Orlova
Laboratory “Energy Research Centre”, Institute of Electronics and Computer Sciences, LV-1006 Riga, Latvia
7 shared publications N. Levin
4 shared publicationsBaiba Ose-Zala
Institute of Physical Energetics, Aizkraukles iela 21, Riga, LV-1006, Latvia
3 shared publicationsNikolaj Levin
Institute of Physical Energetics, Riga, Latvia
3 shared publications- Leonids Ribickis
Riga Technical University, Riga, Latvia
2 shared publications Nikolay Levin
Institute of Physical Energetics, Aizkraukles iela 21, Riga, LV-1006, Latvia
2 shared publications
Latest Publications
- Open Access
- 20 February 2017
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 23 (1) , 43 - 48
Methods to reduce cogging torque of permanent magnet synchronous generator used in wind power plants
Methods to reduce cogging torque of permanent magnet synchronous generator used in wind power plants
- 20 February 2017
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 23 (1) , 43 - 48
Open AccessMethods to reduce cogging torque of permanent magnet synchronous generator used in wind power plants
Methods to reduce cogging torque of permanent magnet synchronous generator used in wind power plants
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Analysis of parameters for optimal design of synchronous Reluctance Motor
This paper presents a synchronous reluctance machine as alternative to the permanent magnet machine. Possible designs are considered for the motor rotor, while the stator is of conventional design of the induction machine with 48 slots and distributed double-layer winding. In the work, analysis is given for the parameters of an optimal design of synchronous reluctance motor. The modelling of electromagnetic field is performed in the JMAG software based on the finite element method. The basic geometric dimensions are taken from the permanent magnet machine used in Toyota Prius.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Analysis of parameters for optimal design of synchronous Reluctance Motor
This paper presents a synchronous reluctance machine as alternative to the permanent magnet machine. Possible designs are considered for the motor rotor, while the stator is of conventional design of the induction machine with 48 slots and distributed double-layer winding. In the work, analysis is given for the parameters of an optimal design of synchronous reluctance motor. The modelling of electromagnetic field is performed in the JMAG software based on the finite element method. The basic geometric dimensions are taken from the permanent magnet machine used in Toyota Prius.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-198
Start-up torques of permanent magnet synchronous generator with non-overlapping concentrated windings
In this paper there are analyzed the start-up torques of PMSGs that are directly connected to the turbine and are used in wind power plants (WPP). In such generators the start-up torques are high, which leads to necessity of faster wind to overpass the torque, but that shortens the diapason of working wind speed. There are researched the values of startup torques for PMSG's model with 3-phase winding on (Z 1 = 18) stator teeth. The values are obtained by different design parameters, such as: PM's pole pair number, opened and half-opened slots. The torque is calculated in software QuickField.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-198
Start-up torques of permanent magnet synchronous generator with non-overlapping concentrated windings
In this paper there are analyzed the start-up torques of PMSGs that are directly connected to the turbine and are used in wind power plants (WPP). In such generators the start-up torques are high, which leads to necessity of faster wind to overpass the torque, but that shortens the diapason of working wind speed. There are researched the values of startup torques for PMSG's model with 3-phase winding on (Z 1 = 18) stator teeth. The values are obtained by different design parameters, such as: PM's pole pair number, opened and half-opened slots. The torque is calculated in software QuickField.
- 8 January 2013
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 19 (1) , 23-26
Methods to Reduce the Cogging Torque in Permanent Magnet Synchronous Machines
The phenomenon of cogging torque in permanent magnet synchronous generators with concentrated windings is considered in this work. Dependence of fluctuation amplitude of the torque on width of stator slot opening is researched. The method to reduce the cogging torque by skewing of stator slot and opening of stator slot width equal distance between magnet and tooth on the rotor is described. The construction of this generator is obtained on the basis of numerical simulation results.DOI: http://dx.doi.org/10.5755/j01.eee.19.1.3248
- 8 January 2013
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 19 (1) , 23-26
Methods to Reduce the Cogging Torque in Permanent Magnet Synchronous Machines
The phenomenon of cogging torque in permanent magnet synchronous generators with concentrated windings is considered in this work. Dependence of fluctuation amplitude of the torque on width of stator slot opening is researched. The method to reduce the cogging torque by skewing of stator slot and opening of stator slot width equal distance between magnet and tooth on the rotor is described. The construction of this generator is obtained on the basis of numerical simulation results.DOI: http://dx.doi.org/10.5755/j01.eee.19.1.3248
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
The comparison of active and reactive magnetic couplers
In this paper there are researched and compared three types of cylindrical magnetic couplers (MC): active MC, reactive MC with yoke and reactive MC without yoke. The comparison is made by the couplers' maximal mechanical torque, which is their main characteristic. The torque is calculated applying software QuickField by designing the magnetic field. The QuickField is based on the finite elements method. It is researched and recommended a new type of reactive MC.
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
The comparison of active and reactive magnetic couplers
In this paper there are researched and compared three types of cylindrical magnetic couplers (MC): active MC, reactive MC with yoke and reactive MC without yoke. The comparison is made by the couplers' maximal mechanical torque, which is their main characteristic. The torque is calculated applying software QuickField by designing the magnetic field. The QuickField is based on the finite elements method. It is researched and recommended a new type of reactive MC.
- Open Access
- 1 January 2012
- Published by Walter de Gruyter GmbH in Latvian Journal of Physics and Technical Sciences
- Vol. 49 (4) , 14-20
Direct-Drive Contactless Wind Generator with Concentrated Winding
- 1 January 2012
- Published by Walter de Gruyter GmbH in Latvian Journal of Physics and Technical Sciences
- Vol. 49 (4) , 14-20
Open AccessDirect-Drive Contactless Wind Generator with Concentrated Winding
- Open Access
- 1 January 2012
- Published by Walter de Gruyter GmbH in Latvian Journal of Physics and Technical Sciences
- Vol. 49 (1) , 35-41
Hybrid Excitation of the Axial Inductor Machine
The paper considers the possibility to use permanent magnets in the rotor slots of axial inductor machine with the aim to create a hybrid excitation of such a machine - from the magnets and from the excitation winding which is placed between the stator cores. The hybrid excitation allows the weight and size parameters of the machine to be improved. Under consideration is a 32 kW under-carriage generator 2ГB.13.Y1.
- 1 January 2012
- Published by Walter de Gruyter GmbH in Latvian Journal of Physics and Technical Sciences
- Vol. 49 (1) , 35-41
Open AccessHybrid Excitation of the Axial Inductor Machine
The paper considers the possibility to use permanent magnets in the rotor slots of axial inductor machine with the aim to create a hybrid excitation of such a machine - from the magnets and from the excitation winding which is placed between the stator cores. The hybrid excitation allows the weight and size parameters of the machine to be improved. Under consideration is a 32 kW under-carriage generator 2ГB.13.Y1.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 761-765
The influence of permanent magnets' width and number on the mechanical torque of a magnetic coupler with rectangular permanent magnets
The purpose of this paper is to analyze the influence of permanent magnets' number and width on the torque of a magnetic coupler, which has rectangular form permanent magnets. The work includes the calculation of a mechanical torque, applying program QuickField, which calculates magnetic field, using finite element method (FEM). The calculations are made for actually operating magnetic couplers. The mechanical torque is calculated in QuickField and compared with an experimentally obtained mechanical torque. The most suitable combination of magnets' number and width has been found.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 761-765
The influence of permanent magnets' width and number on the mechanical torque of a magnetic coupler with rectangular permanent magnets
The purpose of this paper is to analyze the influence of permanent magnets' number and width on the torque of a magnetic coupler, which has rectangular form permanent magnets. The work includes the calculation of a mechanical torque, applying program QuickField, which calculates magnetic field, using finite element method (FEM). The calculations are made for actually operating magnetic couplers. The mechanical torque is calculated in QuickField and compared with an experimentally obtained mechanical torque. The most suitable combination of magnets' number and width has been found.
- 1 September 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. T4-77-T4-81
Optimization of the magnetic circuit of the homopolar inductor machine with non-overlapping concentrated windings
The present work considers issues about optimization of the tooth zone of homopolar inductor generator with non-overlapping concentrated coils. The recommendations for the choice of optimal parameters of the tooth zone are made on the basis of the analysis of magnetic field in the machine's cross-section. The results of the experiment data of the inductor generator's test sample with the power of 32 kW are also presented in the work.
- 1 September 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. T4-77-T4-81
Optimization of the magnetic circuit of the homopolar inductor machine with non-overlapping concentrated windings
The present work considers issues about optimization of the tooth zone of homopolar inductor generator with non-overlapping concentrated coils. The recommendations for the choice of optimal parameters of the tooth zone are made on the basis of the analysis of magnetic field in the machine's cross-section. The results of the experiment data of the inductor generator's test sample with the power of 32 kW are also presented in the work.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 282-286
Non-overlapping concentrated windings in homopolar inductor machines
The work considers the issues connected with application of non-overlapping coils in the homopolar inductor machines. The calculation and analysis are performed for the magnetic field in the tooth zone of such a machine, and, based on the results, recommendations are given on the choice of optimal parameters of the tooth zone. The sample under study is a 32 kW experimental inductor generator.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 282-286
Non-overlapping concentrated windings in homopolar inductor machines
The work considers the issues connected with application of non-overlapping coils in the homopolar inductor machines. The calculation and analysis are performed for the magnetic field in the tooth zone of such a machine, and, based on the results, recommendations are given on the choice of optimal parameters of the tooth zone. The sample under study is a 32 kW experimental inductor generator.