  • Numerical Investigation of a U‐Tube Solar Collector Including Phase‐Change Material Enhanced by Metal Foam

    by Saif Y. Ibrahim, Maathe A. Theeb

    To improve the thermal performance and storage capacity of evacuated‐tube solar collectors (ETSCs), phase‐change materials (PCMs) have been widely integrated into ETSC systems. However, the low thermal conductivity of PCMs limits heat transfer within the storage domain. In this study, a three‐dimensional numerical model of a U‐tube ETSC integrated with PCM enhanced by copper metal foam (PCM–MF) is developed to investigate the influence of thermal conductivity enhancement on system performance. Three operating conditions based on the heat‐transfer fluid (HTF) flow are examined: continuous HTF circulation, a 1‐h zero‐flow charging period, and an intermittent operation mode that combines charging and discharging periods. The results show that under continuous HTF circulation, the PCM–MF configuration enhances heat transfer, increasing the thermal efficiency from 89.27% to 91.10%. However, this enhancement accelerates heat extraction from the PCM, suppressing melting and reducing the stored thermal energy, whereas a pure PCM stores approximately 39.7% more energy under the same conditions. In the absence of HTF flow (i.e., zero flow), the role of the MF shifts from heat extraction to heat distribution. The PCM–MF exhibits faster, more uniform melting, reducing melting time by about 10 min while maintaining storage performance comparable to that of pure PCM. Under intermittent HTF operation, in which a heating period without flow is followed by fluid circulation, the PCM–MF configuration shows improved performance compared with continuous‐flow conditions. The stored thermal energy of PCM–MF increases from 63.63 kJ under continuous flow to 74.6 kJ under intermittent operation, while the storage efficiency rises from 5.90% to 6.91%. However, the pure PCM configuration still exhibits a higher total energy storage capacity. These results demonstrate that the effect of MF is strongly dependent on the operating mode, with a trade‐off between heat‐transfer enhancement and thermal energy storage capacity in PCM–MF solar collectors.

  • Open Access

    Experimental study on refrigerant mixing as a drop-in substitute for R134a in a domestic refrigerator

    by Mohammed F. Mohammed, Maathe A. Theeb

    This research aims to find ways to use different mixtures instead of R134a refrigerants that are more efficient and better for the environment. The Kyoto Protocol states that hydrofluorocarbon refrigerants must be replaced due to their high Global Warming Potential values, contributing to environmental damage. The two mixtures tested in this research were both types of refrigerants with different performances, temperature and pressures. The first mixture is composed of R 134a and R1234yf (10:90% by weight), while the second mixture is composed of R600a and R290 (60:40% by weight). The study revealed that the coefficient of performance of the first mixture and second mixture is higher than R134a by 20.44% and 16%, respectively. Also, the power input of R134a is higher than that of the first mixture by 15.3%, while the second mixture is lower than R134a by 25.8%.


  • Open Access

    A review of solar air collectors with baffles and porous medium: Types and applications

    by Mustafa Fouad Yousif, Maathe A. Theeb

    The current study and discussion in detail about the use of different types of porous media and barriers inside solar air heaters is our goal in this survey paper. The effect of different barriers and porous materials of different shapes and types within the solar air collectors and the effect of engineering parameters on heat transfer procedures and fluid movement were discussed by examining their thermal and hydraulic performance. Numerical and experimental analyses were presented on different types of flat solar air collectors containing differently shaped baffles or various porous media with different strategies to enhance heat transfer such as fluid flow measurement, pressure drop control, and checking their thermal and hydraulic performance by measuring the increase in air temperature at intensity Solar radiation and fluid mass flow. Studies show that the presence of porous barriers or media enhances the heat transfer process and increases the efficiency of solar air collectors. The types different of solar air collectors have been shown. We concluded this review to present various applications of solar air collectors such as cooling and heating various buildings, heating air for combustion processes, and drying coal and paper.


  • Open Access

    UTILIZING WASTE HEAT FROM THE REFRIGERATION CYCLE BY USING A TWO-STAGE HEAT EXCHANGER

    by Safaa M. Ali, Maathe A. Theeb

    Refrigeration, and air conditioning systems are designed to transport heat from internal spaces or products and discard it into the surrounding. Refutation of heat might happen in a straight line to the air, as in the case of most conventional units of air-source, or to water flowing from a cooling tower. This heat is of a "low-grade diversity", it still signifies wasted energy. According to the viewpoint of energy conservation, it would be necessary to regain this heat in a serviceable form. In this research, a practical study aims to collect the heat emitted from the cooling condenser by 35% and exploit it in heating hot water for domestic purposes, in addition to other uses, including reducing the consumption of electrical energy as a result of exploiting and collecting waste heat, from cooling devices using a system consisting of two types of helical heat exchangers and two stages. The first stage consists of a tube-in-tube helical exchanger and the second stage includes a tube-in-shell heat exchanger using R410A refrigerant. The EES engineering equation solving program was used to solve the numerical equations that are used to solve problems related to thermodynamics, due to its high accuracy in solving equations, extracting values and graphs, and calculating the performance coefficient of the COP to obtain better efficiency for the work of the system, as it was found that the higher the temperature. As a result of increasing the flow rate of deionized water, the percentage of performance coefficient of COP has increased.


  • Open Access

    Post-Impact Characteristics of a Diesel-in-Water Emulsion Droplet on a Flat Surface Below the Leidenfrost Temperature

    by Ahmad Muneer El-Deen Faik, Maathe Abdulwahed Theeb, Yang Zhang

    Droplet impingement on solid surfaces takes place in a variety of industrial and environmental applications. However, there are still some areas that are not fully comprehended; emulsion droplet impact on a heated surface is one of these areas that require further comprehension. Hence, the present work represents an experimental exploration for spread characteristics of diesel-in-water (DW) emulsion droplet impacting a heated flat plate. Three different emulsions in which water concentration is set to 10%, 20%, and 30% of the overall emulsion content by volume have been tested in addition to the neat diesel. The temperature of the flat plate is varied over the range 20, 40, 60, and 80 degrees C respectively. Magnified high speed direct imaging and shadowgraphy have been used simultaneously for tracking droplet spread over the heated surface post impact. Droplet spread rate. maximum diameter, rebound height and velocity represent the main evaluated parameters. The results show that the maximum spread diameter is proportional while spread rate is inversely proportional to the increase in plate temperature for all diesel concentrations including the neat diesel. Whereas. droplet rebound height and velocity are found to be more responsive to the variation in diesel concentration than the variation in plate temperature, so they are both minimum in the case of neat diesel and are increasing by the decrease of diesel concentration in the emulsions.


  • An empirical model for predicting the length of a capillary tube

    by Basim Freegah, Qasim Saleh, Maathe A. Theeb

    Any refrigerant device consists of several parts, and one of the most significant parts is the expansion device. This expansion device can be classified into several types according to the size of the refrigeration system. The capillary tube is used usually with a small refrigerant system size to reduce the higher pressure in the condenser into the low pressure in the evaporator. In this study, the effect of the capillary tube's diameter and that of the temperature of the condenser and evaporator on the length of such a device has been theoretically studied. Furthermore, a validation between the theoretical analysis and experimental findings from the literature review has been carried out. To achieve the theoretical aspect, MATLAB code has been developed. The results showed that the maximum difference between the theoretical and experimental results regarding temperature and pressure refrigeration is around 5% and 3.4%, respectively. Also, the results depict that the inner diameter and the condenser temperature have an effect on the length of the capillary tube. However, the effect of the inner diameter is higher compared with the condenser temperature. In addition, an equation to predict the length of the capillary tube has been developed with an accuracy of 98%. This equation is created as a function of the capillary tube's diameter and the temperature of the condenser and the evaporator. Moreover, this equation can be used to predict the length of the capillary tube for small refrigeration devices, especially those operating under 10 KW. The findings of this study can help make a mathematical approach used for the design of the capillary tube simpler and easier to apply.


  • Open Access

    Dynamic Performance of Various Thermal Energy Storage Materials

    by M H Alhamdo, M A Theeb, H S Alani

    The thermal effects of metal partitions inside Porous Thermal Energy Storage (PTES) have been investigated experimentally and theoretically. Four circular cross-sectional area matrices have been studied and comparison was made between them. These include; storage with Flat Plate partitions (FP), storage with Corrugated Plate partitions (CP), storage with Wire Mesh partitions (WM), and storage Without Partitions (WP). A numerical model has been developed to simulate dynamic thermal energy transfer within (PTES) to include the important thermal effects of the partitions within porous matrices. The developed numerical model is characterized by system of differential energy conservation equations, these equations are solved numerically by time marching implicit method. The theoretical analysis and computational scheme validity has been verified through comparisons with measured data from the experimental work conducted in this work. The investigation has been done for Reynolds number, Re, of 1270 <Re < 8050. A convenient agreement was found between theoretical and experimental results for all of the tested matrices. The metal partitions were specified to have considerable effect on the thermal response for each type of the tested materials. From the comparison of different matrices concerning their ratio between pressure drop and heat transfer, it was found that the (CP) matrix has the highest performance. In this work, an improved transient method was presented for the calculation of the average heat transfer coefficient for porous flow channels along the axial direction with the thermal effects of the metal partitions. A correlation equation been developed for the J-factor have for each matrix material at the range of Reynold’s number under investigation. The new (three) correlations predicting the J-factor are found to be in reasonable agreement with the limited published data. However, these correlations have been included the effect of the inside partitions, which have been ignored in all previous published data.


  • Open Access

    The effect of aspect ratio on heat transfer in a square cavity filled with a porous medium

    by M A Theeb

    Two dimensional mathematical model of an enclosure filled with a porous medium and heated from the lower end with various values of the width to height ratio (aspect ratio) has been studied in the present article. A two dimensional free convection model has been solved numerically using finite difference technique to evaluate the streamlines, isotherm lines, and the average Nusslet number. The set values where; Rayleigh number of 106, Prandtl number of 0.72, and aspect ratio ranging from 1:4 to 4:1. The model has been validated and the results showed that the aspect ratio has a clear effect on the average Nusselt number and that increasing the flow rate for aspect ratio form 1:4 to 4:1.


  • Experimental and theoretical study of waste heat recovery from a refrigeration system using a finned helical coil heat exchanger

    by Bahaulddin K. Roomi, Maathe A. Theeb

    This paper is an experimental and theoretical study that aimed at conserving energy by utilizing the waste heat generated from a refrigeration system by calculating the range of condensation after the compression stage for the refrigerant (R410A). A helical coil tube‐shell heat exchanger was designed as a heat recovery unit to use the waste heat from an air conditioner 1TR (split type) in the outdoor unit between the compressor and the condenser to produce hot water and increase the coefficient of performance (COP) of the refrigeration cycle. Two experimental types of the helical coil heat exchanger (conventional and finned) were used in attempts to induce absorption of the rejected heat into tap water. The increase in the COP ranges from 12.5% to 40%, an increase in the water outlet temperatures difference reaches 12°C. A cost–benefit analysis in terms of the net present value and the payback period (PP) has been performed. From the analysis, it has been observed that the use of the designed heat recovery unit will save electrical consumption to produce the required hot water with a PP of about 11.7 months for the conventional heat exchanger and 17.5 months for the finned helical coil heat exchanger.