Carlos Arroyave
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carlos Arroyave has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
A. L. Morales
4 shared publicationsC. A. Barrero
4 shared publications- Franklin Jaramillo
Center for Research Innovation and Development of Materials–CIDEMAT Faculty of Engineering University of Antioquia–UdeA Medellín Colombia
4 shared publications - Jean Marc Greneche
Institut des Molécules et Matériaux (IMMM UMR CNRS 6238), Le Mans Université, 72085 Le Mans Cedex 9, France
4 shared publications D. M. Escobar
3 shared publications- Felix Echeverria
Centro de Investigación, Innovación y Desarrollo de Materiales—CIDEMAT, Facultad de Ingeniería, Universidad de Antioquia UdeA, Calle 70 No 52-21, Medellín 050010, Colombia
3 shared publications
Latest Publications
- Open Access
- 1 January 2017
- Published by Universidad Nacional Autonoma de Mexico in Atmósfera
- Vol. 30 (1) , 53-61
Annual atmospheric corrosion rate and dose-response function for carbon steel in Bogotá
Annual atmospheric corrosion rate and dose-response function for carbon steel in Bogotá
- 1 January 2017
- Published by Universidad Nacional Autonoma de Mexico in Atmósfera
- Vol. 30 (1) , 53-61
Open AccessAnnual atmospheric corrosion rate and dose-response function for carbon steel in Bogotá
Annual atmospheric corrosion rate and dose-response function for carbon steel in Bogotá
- Open Access
- 11 May 2015
- Published by Universidad Nacional de Colombia in DYNA
- Vol. 82 (190) , 128-137
Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards
This paper presents the first systematic atmospheric corrosion assessment in Bogota. Main facts about the study are related with special characteristics of the City, such as population (more than eight million inhabitants), and altitude (2600 m over the sea level). Relative humidity, temperature, and SO2 concentration were measured. Simultaneously, corrosion rate of AIS/SAE 1006 plain steel was measured along one year. Results show that atmospheric corrosion is between C2 – C3 levels, according to the ISO 9223 standard. Nevertheless, estimations from meteorological parameters produce lower corrosivities and, taking into account SO2 concentrations, corrosivities in places with higher relative humidity, are higher than corrosivities measured on steel coupons. In general, the main pollution problem is particulate matter, but higher corrosion rates were directly associated with SO2 levels. Gaps between found results and international estimation methodologies are evident. Some explanations about that, are proposed.
- 11 May 2015
- Published by Universidad Nacional de Colombia in DYNA
- Vol. 82 (190) , 128-137
Open AccessAtmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards
This paper presents the first systematic atmospheric corrosion assessment in Bogota. Main facts about the study are related with special characteristics of the City, such as population (more than eight million inhabitants), and altitude (2600 m over the sea level). Relative humidity, temperature, and SO2 concentration were measured. Simultaneously, corrosion rate of AIS/SAE 1006 plain steel was measured along one year. Results show that atmospheric corrosion is between C2 – C3 levels, according to the ISO 9223 standard. Nevertheless, estimations from meteorological parameters produce lower corrosivities and, taking into account SO2 concentrations, corrosivities in places with higher relative humidity, are higher than corrosivities measured on steel coupons. In general, the main pollution problem is particulate matter, but higher corrosion rates were directly associated with SO2 levels. Gaps between found results and international estimation methodologies are evident. Some explanations about that, are proposed.
- Open Access
- 1 January 2009
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 20 (10) , 1841-1848
Study of the copper corrosion mechanism in the presence of propionic acid vapors
O mecanismo da interação entre o cobre e os vapores do ácido propiônico é apresentado. As exposições foram realizadas em diferentes tempos e concentração de poluentes. Varredura Catódica, XRD e SEM foram usados para quantificar o grau de deterioração. Os resultados obtidos foram explicados pelo seguinte mecanismo: Uma camada do cuprita (Cu 2 O) é formada imediatamente. Este composto, na presença da água adsorvida é oxidado a tenorita (CuO) com aumento do pH. A hidratação da camada de tenorita beneficia a formação de um hidróxido CuOxH 2 O. Enquanto o nível do poluente é aumentado, o propionato básico insolúvel é formado (Cu(OH) x (Pro) 2-x ). Concentrações mais elevadas de ácido propiônico acidificam as mono camadas e um composto novo Cu (Pro) 2 •H 2 O começa a se precipitar em pH baixo. Este é o constituinte principal da pátina verde- oliva formada nessas condições. Este mecanismo concorda, em termos gerais, com os propostos em trabalhos precedentes visando estudar a interação entre o cobre e os ácidos acético e fórmico. The interaction mechanism between copper and propionic acid vapors is shown. Exposures were carried out to various pollutant concentrations and times. Cathodic scan, x-ray diffraction (XRD) and scanning electrode microscope (SEM) were used to quantify the degree of deterioration. The results obtained were explained by the following mechanism: A cuprite (Cu 2 O) layer covers the copper surface immediately; this compound in presence of adsorbed water is oxidized to tenorite (CuO). The hydration of the tenorite layer benefits the formation of a hydroxide compound such as CuOxH 2 O. As the pollutant level is increased, insoluble basic propionate is formed (Cu(OH) x (CH 3 CH 2 COO) 2-x ). Higher concentrations of propionic acid acidify the monolayers and a new compound Cu(CH 3 CH 2 COO) 2 •H 2 O begins to precipitate at low pH, this is the main constituent of the green olive patina formed under these conditions. This mechanism agrees, in general terms, with those proposed in previous works to study the interaction between copper and the acetic and formic acids.
- 1 January 2009
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 20 (10) , 1841-1848
Open AccessStudy of the copper corrosion mechanism in the presence of propionic acid vapors
O mecanismo da interação entre o cobre e os vapores do ácido propiônico é apresentado. As exposições foram realizadas em diferentes tempos e concentração de poluentes. Varredura Catódica, XRD e SEM foram usados para quantificar o grau de deterioração. Os resultados obtidos foram explicados pelo seguinte mecanismo: Uma camada do cuprita (Cu 2 O) é formada imediatamente. Este composto, na presença da água adsorvida é oxidado a tenorita (CuO) com aumento do pH. A hidratação da camada de tenorita beneficia a formação de um hidróxido CuOxH 2 O. Enquanto o nível do poluente é aumentado, o propionato básico insolúvel é formado (Cu(OH) x (Pro) 2-x ). Concentrações mais elevadas de ácido propiônico acidificam as mono camadas e um composto novo Cu (Pro) 2 •H 2 O começa a se precipitar em pH baixo. Este é o constituinte principal da pátina verde- oliva formada nessas condições. Este mecanismo concorda, em termos gerais, com os propostos em trabalhos precedentes visando estudar a interação entre o cobre e os ácidos acético e fórmico. The interaction mechanism between copper and propionic acid vapors is shown. Exposures were carried out to various pollutant concentrations and times. Cathodic scan, x-ray diffraction (XRD) and scanning electrode microscope (SEM) were used to quantify the degree of deterioration. The results obtained were explained by the following mechanism: A cuprite (Cu 2 O) layer covers the copper surface immediately; this compound in presence of adsorbed water is oxidized to tenorite (CuO). The hydration of the tenorite layer benefits the formation of a hydroxide compound such as CuOxH 2 O. As the pollutant level is increased, insoluble basic propionate is formed (Cu(OH) x (CH 3 CH 2 COO) 2-x ). Higher concentrations of propionic acid acidify the monolayers and a new compound Cu(CH 3 CH 2 COO) 2 •H 2 O begins to precipitate at low pH, this is the main constituent of the green olive patina formed under these conditions. This mechanism agrees, in general terms, with those proposed in previous works to study the interaction between copper and the acetic and formic acids.
- Open Access
- 1 January 2009
- Published by SciELO Agencia Nacional de Investigacion y Desarrollo (ANID) in Journal of the Chilean Chemical Society
- Vol. 54 (3) , 212-217
INFLUENCE OF ENVIRONMENTAL FACTORS IN THE ATMOSPHERIC CORROSION OF COPPER IN THE PRESENCE OF PROPIONIC ACID
- 1 January 2009
- Published by SciELO Agencia Nacional de Investigacion y Desarrollo (ANID) in Journal of the Chilean Chemical Society
- Vol. 54 (3) , 212-217
Open AccessINFLUENCE OF ENVIRONMENTAL FACTORS IN THE ATMOSPHERIC CORROSION OF COPPER IN THE PRESENCE OF PROPIONIC ACID
- 31 July 2007
- Published by Springer Nature in Journal of Materials Science
- Vol. 42 (23) , 9654-9662
Characterization of atmospheric corrosion products of zinc exposed to SO2 and NO2 using XPS and GIXD
- 31 July 2007
- Published by Springer Nature in Journal of Materials Science
- Vol. 42 (23) , 9654-9662
Characterization of atmospheric corrosion products of zinc exposed to SO2 and NO2 using XPS and GIXD
- 1 April 2005
- Published by Elsevier in Corrosion Science
- Vol. 47 (4) , 883-892
Changes in atmospheric corrosion rate caused by chloride ions depending on rain regime
- 1 April 2005
- Published by Elsevier in Corrosion Science
- Vol. 47 (4) , 883-892
Changes in atmospheric corrosion rate caused by chloride ions depending on rain regime
- 1 February 2005
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 61 (2) , 99-110
A Laboratory Approach to the Mechanism of Attack on the Wire-on-Bolt Device Used for Atmospheric Corrosion Studies
While searching for the elucidation of the role of galvanic and crevice effects on the corrosion process of wire-on-bolt specimens used for atmospheric corrosion assessments, an experimental procedure was carried out. This experiment included the exposure of samples to a CEBELCOR chamber, followed by mass-loss measurements and electrochemical and morphological characterization. Results showed that the influence of the crevice can be as important as the galvanic effect, mainly in the Al-Fe system, and that the morphology of the corrosion products and the aeration conditions within the crevice strongly influence the whole process.
- 1 February 2005
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 61 (2) , 99-110
A Laboratory Approach to the Mechanism of Attack on the Wire-on-Bolt Device Used for Atmospheric Corrosion Studies
While searching for the elucidation of the role of galvanic and crevice effects on the corrosion process of wire-on-bolt specimens used for atmospheric corrosion assessments, an experimental procedure was carried out. This experiment included the exposure of samples to a CEBELCOR chamber, followed by mass-loss measurements and electrochemical and morphological characterization. Results showed that the influence of the crevice can be as important as the galvanic effect, mainly in the Al-Fe system, and that the morphology of the corrosion products and the aeration conditions within the crevice strongly influence the whole process.
- 1 December 2004
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 354 (1-4) , 187-190
Magnetic and crystal structure refinement in akaganeite nanoparticle
- 1 December 2004
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 354 (1-4) , 187-190
Magnetic and crystal structure refinement in akaganeite nanoparticle
- 31 October 2004
- Published by Elsevier in International Biodeterioration & Biodegradation
- Vol. 54 (2-3) , 135-141
Biodeterioration of peridotite and other constructional materials in a building of the Colombian cultural heritage
- 31 October 2004
- Published by Elsevier in International Biodeterioration & Biodegradation
- Vol. 54 (2-3) , 135-141
Biodeterioration of peridotite and other constructional materials in a building of the Colombian cultural heritage
- Open Access
- 17 December 2003
- Published by Editorial CSIC in Revista de Metalurgia
- Vol. 39 (Extra) , 265-269
Simulación de los procesos de corrosión atmosférica durante largos períodos de tiempo de un acero autoprotector y ordinario
La información sobre el comportamiento y las características de los productos de corrosión de los aceros auto protectores, después de varias décadas de exposición a la atmósfera, es escasa. Por otra parte, aún no se han desarrollado ensayos de laboratorio de aceptación general para evaluar su resistencia a la corrosión. En consecuencia, cada día toman más importancia los ensayos de laboratorio durante largos periodos de exposición. En el presente trabajo, se sometieron muestras de acero AISI-SAE 1008 y ASTM 588-B, durante dos años, a un ensayo de laboratorio de inmersión-emersión tipo CEBELCOR. Se ensayaron dos grupos de seis muestras de cada composición de acero, en una disolución que trataba de simular una atmósfera urbana moderada. Después del primer año, se retiraron tres muestras de cada grupo y el resto se dejo en el ensayo hasta completar los dos años exposición. Diariamente, se midió el potencial de electrodo respecto al electrodo de Calomel saturado. Las herrumbres formadas se caracterizaron mediante microscopía óptica, espectroscopia Mössbauer e infrarroja con transformada de Fourier y difracción de rayos X. Se realizó una comparación de los resultados obtenidos en este experimento con los reflejados en la literatura y se formularon conclusiones respecto a las diferencias y similitudes en su comportamiento.
- 17 December 2003
- Published by Editorial CSIC in Revista de Metalurgia
- Vol. 39 (Extra) , 265-269
Open AccessSimulación de los procesos de corrosión atmosférica durante largos períodos de tiempo de un acero autoprotector y ordinario
La información sobre el comportamiento y las características de los productos de corrosión de los aceros auto protectores, después de varias décadas de exposición a la atmósfera, es escasa. Por otra parte, aún no se han desarrollado ensayos de laboratorio de aceptación general para evaluar su resistencia a la corrosión. En consecuencia, cada día toman más importancia los ensayos de laboratorio durante largos periodos de exposición. En el presente trabajo, se sometieron muestras de acero AISI-SAE 1008 y ASTM 588-B, durante dos años, a un ensayo de laboratorio de inmersión-emersión tipo CEBELCOR. Se ensayaron dos grupos de seis muestras de cada composición de acero, en una disolución que trataba de simular una atmósfera urbana moderada. Después del primer año, se retiraron tres muestras de cada grupo y el resto se dejo en el ensayo hasta completar los dos años exposición. Diariamente, se midió el potencial de electrodo respecto al electrodo de Calomel saturado. Las herrumbres formadas se caracterizaron mediante microscopía óptica, espectroscopia Mössbauer e infrarroja con transformada de Fourier y difracción de rayos X. Se realizó una comparación de los resultados obtenidos en este experimento con los reflejados en la literatura y se formularon conclusiones respecto a las diferencias y similitudes en su comportamiento.