Kuen Wai Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kuen Wai Ma has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Cheuk Ming Mak
The Hong Kong Polytechnic University
10 shared publications - Hai Ming Wong
The University of Hong Kong
9 shared publications Hai Ming Wong
4 shared publications- Fu-Lai Chung
Department of Computing, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
2 shared publications - Xiujie Li
Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
2 shared publications Cheuk Ming Mak
Department of Building Environment and Energy Engineering , The Hong Kong Polytechnic University , Hong Kong , China
1 shared publication
Latest Publications
- Open Access
- 5 June 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (11) , 5691
Automatic Detection of Third Molar Tooth Development Stages in Panoramic Radiographs for Dental Age Assessment Using Faster R-CNN
Automatic dental age estimation in deep learning applications relies on accurate assessment of tooth development stage (TDS) and regions of interest (ROIs). Since dental development is population-specific, a recent study showed that a two-step approach using an ethnicity-specific reference dataset can improve explainability, transferability across populations, and agreement with chronological age. Therefore, this study aims to investigate whether the proposed population-aware framework can be extended toward greater automation by using Faster Region-Based Convolutional Network (R-CNN) for third-molar detection. A total of 1110 digital panoramic radiographs and 1980 labeled ROIs were used to train and validate four pretrained backbones: AlexNet, DenseNet-201, GoogLeNet, and VGG-16. DenseNet-201 achieved the best training performance and overall validation performance (accuracy = 95% and marco recall = 0.75), followed by GoogLeNet (84.7% and 0.80), VGG-16 (86.6% and 0.75), and AlexNet (79.8% and 0.58). Validation results showed relatively high recall across most TDS stages, whereas precision was lower because of false-positive (FP) detections. Performance was only minimally affected by the intersection-over-union (IoU) threshold, suggesting stable localization behavior. The trained Faster R-CNN models provide a clinical-oriented assistive tool for automatic third-molar detection and TDS classification, serving as an intermediate component that can potentially support more efficient ethnicity-specific dental age estimation in future clinical practice, forensic investigations, and pediatric dentistry.
- 5 June 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (11) , 5691
Open AccessAutomatic Detection of Third Molar Tooth Development Stages in Panoramic Radiographs for Dental Age Assessment Using Faster R-CNN
Automatic dental age estimation in deep learning applications relies on accurate assessment of tooth development stage (TDS) and regions of interest (ROIs). Since dental development is population-specific, a recent study showed that a two-step approach using an ethnicity-specific reference dataset can improve explainability, transferability across populations, and agreement with chronological age. Therefore, this study aims to investigate whether the proposed population-aware framework can be extended toward greater automation by using Faster Region-Based Convolutional Network (R-CNN) for third-molar detection. A total of 1110 digital panoramic radiographs and 1980 labeled ROIs were used to train and validate four pretrained backbones: AlexNet, DenseNet-201, GoogLeNet, and VGG-16. DenseNet-201 achieved the best training performance and overall validation performance (accuracy = 95% and marco recall = 0.75), followed by GoogLeNet (84.7% and 0.80), VGG-16 (86.6% and 0.75), and AlexNet (79.8% and 0.58). Validation results showed relatively high recall across most TDS stages, whereas precision was lower because of false-positive (FP) detections. Performance was only minimally affected by the intersection-over-union (IoU) threshold, suggesting stable localization behavior. The trained Faster R-CNN models provide a clinical-oriented assistive tool for automatic third-molar detection and TDS classification, serving as an intermediate component that can potentially support more efficient ethnicity-specific dental age estimation in future clinical practice, forensic investigations, and pediatric dentistry.
- Open Access
Evaluation of Psychoacoustic Machine Learning Assessment Method for Predicting Occupant Well-Being
In modern buildings, the air-conditioned indoor environment is vital for occupant productivity and well-being, yet fan noise and airflow turbulence can significantly compromise these benefits. Human–environmental interactions are complex processes that traditional energy-based acoustic metrics are often insufficient to model. Therefore, this study aims to advance the multidimensional sound quality assessment framework for building acoustics. Three methods, the conventional regression approach (CRA), general prediction model (GPM), and psychoacoustic machine learning (PML) assessment methods, were evaluated for predicting three perceptual dimensions (Evaluation, Potency, Activity; EPA) and negative noise impacts on occupant well-being (O1: Discomfortable, O2: Annoying, O3: Stressful, and O4: Unacceptable). Based on 432 multidimensional sound quality assessments across four general types of air-conditioned built environments, the PML achieved the best goodness-of-fit for the EPA-score perdition (adjusted R2 = 0.61) compared to CRA (0.32) and GPM (0.15) and effectively predicted all negative noise impacts (adjusted R2 = 0.53–0.61). The PML assessment method offers a smart and reliable solution for sound quality and well-being prediction through psychoacoustic heatmaps encoding time-varying psychoacoustic features in 227 × 227 pixels from 30 s soundtracks of the built environment for sustainable building design.
Open AccessEvaluation of Psychoacoustic Machine Learning Assessment Method for Predicting Occupant Well-Being
In modern buildings, the air-conditioned indoor environment is vital for occupant productivity and well-being, yet fan noise and airflow turbulence can significantly compromise these benefits. Human–environmental interactions are complex processes that traditional energy-based acoustic metrics are often insufficient to model. Therefore, this study aims to advance the multidimensional sound quality assessment framework for building acoustics. Three methods, the conventional regression approach (CRA), general prediction model (GPM), and psychoacoustic machine learning (PML) assessment methods, were evaluated for predicting three perceptual dimensions (Evaluation, Potency, Activity; EPA) and negative noise impacts on occupant well-being (O1: Discomfortable, O2: Annoying, O3: Stressful, and O4: Unacceptable). Based on 432 multidimensional sound quality assessments across four general types of air-conditioned built environments, the PML achieved the best goodness-of-fit for the EPA-score perdition (adjusted R2 = 0.61) compared to CRA (0.32) and GPM (0.15) and effectively predicted all negative noise impacts (adjusted R2 = 0.53–0.61). The PML assessment method offers a smart and reliable solution for sound quality and well-being prediction through psychoacoustic heatmaps encoding time-varying psychoacoustic features in 227 × 227 pixels from 30 s soundtracks of the built environment for sustainable building design.
- Open Access
Advanced Acoustic Monitoring Using Psychoacoustic Heatmap Machine Learning Models for Noise Impact Prediction in Air-Conditioned Building Environments
Air-conditioning systems are vital for indoor environmental quality. However, noise can offset its benefits, making acoustic monitoring important. Recent research revealed that sound quality perceptions can be described by three psychological dimensions: Evaluation, Potency, and Activity (EPA). This is the first study to develop psychoacoustic heatmap machine learning models (PHMLM) for predicting sound quality and the negative noise impacts (O1: Discomfortable, O2: Annoying, O3: Stressful, and O4: Unacceptable) of air conditioning sounds using a 227 × 227-pixel psychoacoustic heatmap as input for machine learning. A total of 1208 jury listening tests were conducted with 101 participants on 30 s soundtracks from air-conditioned environments. Psychoacoustic heatmaps were generated by converting time-varying psychoacoustic metrics (N, S, R, and FS) into intensity maps containing 51,529 pixels of multidimensional acoustic information. The PHMLMs achieved predictive performance with correlation coefficients of 0.79, 0.80, and 0.62 for E-, P-, and A-scores, respectively. Compared to traditional regression models (TRM), PHMLM-EPA demonstrated significantly better performance with 31% lower mean absolute error (4.4 vs. 6.4) and higher regression slope (0.798 vs. 0.587). Moreover, PHMLM-EPA demonstrated a higher goodness-of-fit than TRM (+55% to +95%) and traditional acoustic metric LAeq (+87% to +95%). The approach offers an advanced acoustic monitoring method for sustainable building designs.
Open AccessAdvanced Acoustic Monitoring Using Psychoacoustic Heatmap Machine Learning Models for Noise Impact Prediction in Air-Conditioned Building Environments
Air-conditioning systems are vital for indoor environmental quality. However, noise can offset its benefits, making acoustic monitoring important. Recent research revealed that sound quality perceptions can be described by three psychological dimensions: Evaluation, Potency, and Activity (EPA). This is the first study to develop psychoacoustic heatmap machine learning models (PHMLM) for predicting sound quality and the negative noise impacts (O1: Discomfortable, O2: Annoying, O3: Stressful, and O4: Unacceptable) of air conditioning sounds using a 227 × 227-pixel psychoacoustic heatmap as input for machine learning. A total of 1208 jury listening tests were conducted with 101 participants on 30 s soundtracks from air-conditioned environments. Psychoacoustic heatmaps were generated by converting time-varying psychoacoustic metrics (N, S, R, and FS) into intensity maps containing 51,529 pixels of multidimensional acoustic information. The PHMLMs achieved predictive performance with correlation coefficients of 0.79, 0.80, and 0.62 for E-, P-, and A-scores, respectively. Compared to traditional regression models (TRM), PHMLM-EPA demonstrated significantly better performance with 31% lower mean absolute error (4.4 vs. 6.4) and higher regression slope (0.798 vs. 0.587). Moreover, PHMLM-EPA demonstrated a higher goodness-of-fit than TRM (+55% to +95%) and traditional acoustic metric LAeq (+87% to +95%). The approach offers an advanced acoustic monitoring method for sustainable building designs.
- Open Access
- 1 January 2026
- Published by Walter de Gruyter GmbH in Noise Mapping
- Vol. 13 (1)
The acoustic effects of temporal and spectral characteristics on traffic sound sensitivity
Traffic noise is the common component at road intersections in the outdoor environment, and the sounds of traffic light signals are designed to distinguish signal transition between red and green. However, the sounds of traffic light signals are often masked by high levels of vehicle noise produced by high traffic flow. Therefore, this study aims to investigate the acoustic effects of traffic light signals and noise on sound sensitivity in the outdoor environment. A set of psychoacoustic indicators were applied to assess the traffic noise consisting of traffic light signals and vehicle noise at road intersections in Hong Kong. Furthermore, the subjective listening tests evaluated the acoustic sensitivity and perceptions. The results of psychoacoustic time-varying curves revealed distinct characteristics of traffic light signals, with fluctuation strength differing significantly between red and green signals. Moreover, the subjective perceptions of rapid tempo and regularity were significantly correlated with the measured fluctuation strength and rhythmic events per minute (REPM) during the signal transition. These findings will be the insight into the acoustic interactions between various sound sources and their perceptual implications in the outdoor environment.
- 1 January 2026
- Published by Walter de Gruyter GmbH in Noise Mapping
- Vol. 13 (1)
Open AccessThe acoustic effects of temporal and spectral characteristics on traffic sound sensitivity
Traffic noise is the common component at road intersections in the outdoor environment, and the sounds of traffic light signals are designed to distinguish signal transition between red and green. However, the sounds of traffic light signals are often masked by high levels of vehicle noise produced by high traffic flow. Therefore, this study aims to investigate the acoustic effects of traffic light signals and noise on sound sensitivity in the outdoor environment. A set of psychoacoustic indicators were applied to assess the traffic noise consisting of traffic light signals and vehicle noise at road intersections in Hong Kong. Furthermore, the subjective listening tests evaluated the acoustic sensitivity and perceptions. The results of psychoacoustic time-varying curves revealed distinct characteristics of traffic light signals, with fluctuation strength differing significantly between red and green signals. Moreover, the subjective perceptions of rapid tempo and regularity were significantly correlated with the measured fluctuation strength and rhythmic events per minute (REPM) during the signal transition. These findings will be the insight into the acoustic interactions between various sound sources and their perceptual implications in the outdoor environment.
- 21 April 2021
- Published by AIP Publishing
- Vol. 33 (4) , 047111
10.1063/5.0048848.1
In the setting of widespread severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) community transmission, reducing the exposure risk on dental professionals and the next patients is the key to reopening dental services in this pandemic environment. The study is motivated by the lack of understanding of the flow-field characteristics and droplet distribution during aerosol-generating procedures. The particle image velocimetry measurements with high temporal and spatial resolutions were performed under ultrasonic scaling in the mockup experimental dental clinic. Compared with other methods focusing on the settled droplet particles, the study focused on the visualization of suspended droplets. From the results of the velocity vector and trajectory map, the high-level contaminated area will be within 1 m from the oral cavity. The vortex structures were identified by the vorticity index. In the surface near the patient's head, a counterclockwise vortex would carry some droplets and contaminate this region. The small droplets circulated in the turbulence cloud and the droplet nuclei generated by dehydration are the two primary sources of suspended particles, which may cause airborne transmission in the dental clinic. About 65%–74% of the droplets in ultrasonic scaling were in the range of 50–180 μ m. The research will provide references to the development of the precaution measures to reduce the SARS-CoV-2 exposure risk of dental professionals.
- 21 April 2021
- Published by AIP Publishing
- Vol. 33 (4) , 047111
10.1063/5.0048848.1
In the setting of widespread severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) community transmission, reducing the exposure risk on dental professionals and the next patients is the key to reopening dental services in this pandemic environment. The study is motivated by the lack of understanding of the flow-field characteristics and droplet distribution during aerosol-generating procedures. The particle image velocimetry measurements with high temporal and spatial resolutions were performed under ultrasonic scaling in the mockup experimental dental clinic. Compared with other methods focusing on the settled droplet particles, the study focused on the visualization of suspended droplets. From the results of the velocity vector and trajectory map, the high-level contaminated area will be within 1 m from the oral cavity. The vortex structures were identified by the vorticity index. In the surface near the patient's head, a counterclockwise vortex would carry some droplets and contaminate this region. The small droplets circulated in the turbulence cloud and the droplet nuclei generated by dehydration are the two primary sources of suspended particles, which may cause airborne transmission in the dental clinic. About 65%–74% of the droplets in ultrasonic scaling were in the range of 50–180 μ m. The research will provide references to the development of the precaution measures to reduce the SARS-CoV-2 exposure risk of dental professionals.
- 1 April 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (4) , 047111
Evaluating flow-field and expelled droplets in the mockup dental clinic during the COVID-19 pandemic
In the setting of widespread severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) community transmission, reducing the exposure risk on dental professionals and the next patients is the key to reopening dental services in this pandemic environment. The study is motivated by the lack of understanding of the flow-field characteristics and droplet distribution during aerosol-generating procedures. The particle image velocimetry measurements with high temporal and spatial resolutions were performed under ultrasonic scaling in the mockup experimental dental clinic. Compared with other methods focusing on the settled droplet particles, the study focused on the visualization of suspended droplets. From the results of the velocity vector and trajectory map, the high-level contaminated area will be within 1 m from the oral cavity. The vortex structures were identified by the vorticity index. In the surface near the patient's head, a counterclockwise vortex would carry some droplets and contaminate this region. The small droplets circulated in the turbulence cloud and the droplet nuclei generated by dehydration are the two primary sources of suspended particles, which may cause airborne transmission in the dental clinic. About 65%–74% of the droplets in ultrasonic scaling were in the range of 50–180 . The research will provide references to the development of the precaution measures to reduce the SARS-CoV-2 exposure risk of dental professionals.- 1 April 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (4) , 047111
Evaluating flow-field and expelled droplets in the mockup dental clinic during the COVID-19 pandemic
In the setting of widespread severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) community transmission, reducing the exposure risk on dental professionals and the next patients is the key to reopening dental services in this pandemic environment. The study is motivated by the lack of understanding of the flow-field characteristics and droplet distribution during aerosol-generating procedures. The particle image velocimetry measurements with high temporal and spatial resolutions were performed under ultrasonic scaling in the mockup experimental dental clinic. Compared with other methods focusing on the settled droplet particles, the study focused on the visualization of suspended droplets. From the results of the velocity vector and trajectory map, the high-level contaminated area will be within 1 m from the oral cavity. The vortex structures were identified by the vorticity index. In the surface near the patient's head, a counterclockwise vortex would carry some droplets and contaminate this region. The small droplets circulated in the turbulence cloud and the droplet nuclei generated by dehydration are the two primary sources of suspended particles, which may cause airborne transmission in the dental clinic. About 65%–74% of the droplets in ultrasonic scaling were in the range of 50–180 . The research will provide references to the development of the precaution measures to reduce the SARS-CoV-2 exposure risk of dental professionals.- Top Cited Papers
- 1 January 2021
- Published by Elsevier in Applied Acoustics
- Vol. 171
Effects of environmental sound quality on soundscape preference in a public urban space
- 1 January 2021
- Published by Elsevier in Applied Acoustics
- Vol. 171
Top Cited PapersEffects of environmental sound quality on soundscape preference in a public urban space
- 1 November 2020
- Published by Elsevier in Applied Acoustics
- Vol. 168
Acoustical measurements and prediction of psychoacoustic metrics with spatial variation
- 1 November 2020
- Published by Elsevier in Applied Acoustics
- Vol. 168
Acoustical measurements and prediction of psychoacoustic metrics with spatial variation
- 1 May 2020
- Published by Elsevier in Journal of Building Engineering
- Vol. 29
Development of a subjective scale for sound quality assessments in building acoustics
- 1 May 2020
- Published by Elsevier in Journal of Building Engineering
- Vol. 29
Development of a subjective scale for sound quality assessments in building acoustics