Abhijit Saha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abhijit Saha has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
Susmita Maiti
14 shared publicationsSomashree Kundu
Kolkata Ctr, UGC DAE Consortium Sci Res, 3-LB-8 Bidhannagar, Kolkata 700106, India
13 shared publicationsDebasmita Ghosh
UGC-DAE Consortium for Scientific Research, Kolkata Centre, III/LB-8 Bidhannagar, Kolkata, 700098, India
12 shared publicationsTushar Kanti Das
UGC-DAE Consortium for Scientific Research, Kolkata Centre, Kolkata, India
12 shared publicationsChandra Nath Roy
Kolkata Ctr, UGC DAE Consortium Sci Res, 3-LB-8 Bidhannagar, Kolkata 700106, India
11 shared publications- Somrita Mondal
Department of Chemistry and Physics, Southwestern Oklahoma State University, 100 Campus Drive, Weatherford, OK 73096, USA
9 shared publications
Latest Publications
- 27 January 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (2) , 025931
Generating immiscible localized WC phase in layered WS2 upon 15 keV C2+ irradiation
Herein, we report on the insertion of tungsten carbide (WC) phase within tungsten disulfide (WS2) nanosheets taking advantage of the combinatorial effects of implantation of C with low energy irradiation of 15 keV C2+ ions and generating sulfur vacancies. The x-ray diffraction (XRD) analyses suggest the co-existence of WC and WS2 hexagonal phases at mid-fluences of ion implantation, typically in the range of 3.5 × 1015 – 7.5 × 1015 ions cm−2. The phase analysis revealed that WC content was highest at a fluence of 3.5 × 1015 ions cm−2 with ion irradiation of competing electronic (inelastic) and nuclear (elastic) energy losses. The defect-mediated peak can be probed in the Raman spectra, which is the result of numerous point defects (specifically, S vacancies and C as dopants) caused due to the ion irradiation event. First-principles calculations have also been carried out to study the geometrical constructs and electronic structures of WS2 before and after implantation. The doped C atoms in WS2 introduce localized defect states in the conduction band with minima at the M point of the Brillouin zone. Interestingly, the model predicts a semi-metallic behavior, especially when C and S vacancies tend to co-exist. Generating an immiscible WC phase within a few layered WS2 sheets is believed to enhance both the mechanical strength and stability of the specimen apart from the introduction of semi-metallicity needed for desired applications.
- 27 January 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (2) , 025931
Generating immiscible localized WC phase in layered WS2 upon 15 keV C2+ irradiation
Herein, we report on the insertion of tungsten carbide (WC) phase within tungsten disulfide (WS2) nanosheets taking advantage of the combinatorial effects of implantation of C with low energy irradiation of 15 keV C2+ ions and generating sulfur vacancies. The x-ray diffraction (XRD) analyses suggest the co-existence of WC and WS2 hexagonal phases at mid-fluences of ion implantation, typically in the range of 3.5 × 1015 – 7.5 × 1015 ions cm−2. The phase analysis revealed that WC content was highest at a fluence of 3.5 × 1015 ions cm−2 with ion irradiation of competing electronic (inelastic) and nuclear (elastic) energy losses. The defect-mediated peak can be probed in the Raman spectra, which is the result of numerous point defects (specifically, S vacancies and C as dopants) caused due to the ion irradiation event. First-principles calculations have also been carried out to study the geometrical constructs and electronic structures of WS2 before and after implantation. The doped C atoms in WS2 introduce localized defect states in the conduction band with minima at the M point of the Brillouin zone. Interestingly, the model predicts a semi-metallic behavior, especially when C and S vacancies tend to co-exist. Generating an immiscible WC phase within a few layered WS2 sheets is believed to enhance both the mechanical strength and stability of the specimen apart from the introduction of semi-metallicity needed for desired applications.
- 21 June 2024
- Published by Elsevier in Microchemical Journal
- Vol. 204
Ultra-low level detection of biomarker bilirubin by graphene quantum dots and bovine serum albumin enabled turn-on sensing
- 21 June 2024
- Published by Elsevier in Microchemical Journal
- Vol. 204
Ultra-low level detection of biomarker bilirubin by graphene quantum dots and bovine serum albumin enabled turn-on sensing
- 14 March 2024
- Published by Springer Nature
- p. 469-489
Advances in Luminescence-Based Biosensing with Quantum Dots
- 14 March 2024
- Published by Springer Nature
- p. 469-489
Advances in Luminescence-Based Biosensing with Quantum Dots
- 17 February 2024
- Published by Springer Nature in Applied Nanoscience
- Vol. 14 (3) , 507-518
Radiation-assisted synthesis of water soluble starch encapsulated copper nanoparticles and its applicability toward photocatalytic reduction of p-nitrophenol
- 17 February 2024
- Published by Springer Nature in Applied Nanoscience
- Vol. 14 (3) , 507-518
Radiation-assisted synthesis of water soluble starch encapsulated copper nanoparticles and its applicability toward photocatalytic reduction of p-nitrophenol
- Open Access
- 15 June 2023
- Published by Wiley in Physica Status Solidi (b)
- Vol. 260 (6)
Directing Exfoliation, Slipping, and Corrugation in WS2 through Bubbling with 15 keV He2+ Ion Irradiation
- 15 June 2023
- Published by Wiley in Physica Status Solidi (b)
- Vol. 260 (6)
Open AccessDirecting Exfoliation, Slipping, and Corrugation in WS2 through Bubbling with 15 keV He2+ Ion Irradiation
- 8 February 2023
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 8 (1) , 015010
Low power paper electronics based wearable radiation detector using hybrid halide perovskite (MAPbBr3): A real time monitoring of gamma ray
In this report we demonstrate that a paper based flexible gamma ray detector can be made using hybrid halide perovskite methyl ammonium lead bromide (CH3NH3PbBr3 or MAPB). The wearable paper based detector is solution processed and works at room temperature. It detects gamma ray by a direct method by change of its resistance on exposure to gamma ray and uses IDE (interdigitated electrodes) for boosting current response. This detector grown on a substrate like a paper with large active area, shows a maximum calibrated sensitivity of 5.26 μC Gy−1 cm−2 and a reasonable mobility—life time product ( μ τ ) ∼2 × 10−5 cm2 V−1. The detector can be operated in a wide range of gamma photon energy between 100 KeV to 1100 KeV and can detect radiation down to 0.01 μCi activity, which is noise limited. The paper detector shows a good shelf life of more than 6 months and a fast response time of a few seconds. The detector has a high degree of sustenance under exposure to high dose of Gamma radiation and was tested for a cumulative dose of minimum 1.6 KGy. The detector has low power consumption with can operate down to 1 V direct current (DC) bias and with a detector current of ∼1nA. The sensitivity increases with bias and shows saturation beyond 40 V bias. Such a low power flexible gamma detector is expected to have application potential in areas like health care and point of use quick radiation detection.
- 8 February 2023
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 8 (1) , 015010
Low power paper electronics based wearable radiation detector using hybrid halide perovskite (MAPbBr3): A real time monitoring of gamma ray
In this report we demonstrate that a paper based flexible gamma ray detector can be made using hybrid halide perovskite methyl ammonium lead bromide (CH3NH3PbBr3 or MAPB). The wearable paper based detector is solution processed and works at room temperature. It detects gamma ray by a direct method by change of its resistance on exposure to gamma ray and uses IDE (interdigitated electrodes) for boosting current response. This detector grown on a substrate like a paper with large active area, shows a maximum calibrated sensitivity of 5.26 μC Gy−1 cm−2 and a reasonable mobility—life time product ( μ τ ) ∼2 × 10−5 cm2 V−1. The detector can be operated in a wide range of gamma photon energy between 100 KeV to 1100 KeV and can detect radiation down to 0.01 μCi activity, which is noise limited. The paper detector shows a good shelf life of more than 6 months and a fast response time of a few seconds. The detector has a high degree of sustenance under exposure to high dose of Gamma radiation and was tested for a cumulative dose of minimum 1.6 KGy. The detector has low power consumption with can operate down to 1 V direct current (DC) bias and with a detector current of ∼1nA. The sensitivity increases with bias and shows saturation beyond 40 V bias. Such a low power flexible gamma detector is expected to have application potential in areas like health care and point of use quick radiation detection.