Abbas Barfidokht
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abbas Barfidokht has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Wang
University of California San Diego
4 shared publications - Hazhir Teymourian
Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
2 shared publications Juliane R. Sempionatto
Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
2 shared publications- Patrick P. Mercier
Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
2 shared publications - Aftab Ahmed
Ph.D. Scholar, Department of Sociology, Quaid-e-Azam University, Islamabad, Pakistan
1 shared publication Ahmed A. Khorshed
Department of Nanoengineering, University of California, La Jolla, 92093 San Diego, California, United States
1 shared publication
Latest Publications
- 3 September 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (37) , 12767-12775
Extended Noninvasive Glucose Monitoring in the Interstitial Fluid Using an Epidermal Biosensing Patch
An effective, noninvasive glucose monitoring technology could be a pivotal factor for addressing the major unmet needs for managing diabetes mellitus (DM). Here, we describe a skin-worn, disposable, wireless electrochemical biosensor for extended noninvasive monitoring of glucose in the interstitial fluid (ISF). The wearable platform integrates three components: a screen-printed iontophoretic electrode system for ISF extraction by reverse iontophoresis (RI), a printed three-electrode amperometric glucose biosensor, and an electronic interface for control and wireless communication. Prolonged on-body glucose monitoring of up to 8 h, including clinical trials conducted in individuals with and without DM, demonstrated good correlation between glucose blood and ISF concentrations and the ability to monitor dynamically changing glucose levels upon food consumption, with no evidence of skin irritation or discomfort. Such successful extended operation addresses the challenges reported for the GlucoWatch platform by using a lower RI current density at shorter extraction times, along with a lower measurement frequency. Such a noninvasive skin-worn platform could address long-standing challenges with existing glucose monitoring platforms.
- 3 September 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (37) , 12767-12775
Extended Noninvasive Glucose Monitoring in the Interstitial Fluid Using an Epidermal Biosensing Patch
An effective, noninvasive glucose monitoring technology could be a pivotal factor for addressing the major unmet needs for managing diabetes mellitus (DM). Here, we describe a skin-worn, disposable, wireless electrochemical biosensor for extended noninvasive monitoring of glucose in the interstitial fluid (ISF). The wearable platform integrates three components: a screen-printed iontophoretic electrode system for ISF extraction by reverse iontophoresis (RI), a printed three-electrode amperometric glucose biosensor, and an electronic interface for control and wireless communication. Prolonged on-body glucose monitoring of up to 8 h, including clinical trials conducted in individuals with and without DM, demonstrated good correlation between glucose blood and ISF concentrations and the ability to monitor dynamically changing glucose levels upon food consumption, with no evidence of skin irritation or discomfort. Such successful extended operation addresses the challenges reported for the GlucoWatch platform by using a lower RI current density at shorter extraction times, along with a lower measurement frequency. Such a noninvasive skin-worn platform could address long-standing challenges with existing glucose monitoring platforms.
- Top Cited Papers
- 21 August 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (9) , 2679-2700
Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Wearable electrochemical sensors capable of noninvasive monitoring of chemical markers represent a rapidly emerging digital-health technology. Recent advances toward wearable continuous glucose monitoring (CGM) systems have ignited tremendous interest in expanding such sensor technology to other important fields. This article reviews for the first time wearable electrochemical sensors for monitoring therapeutic drugs and drugs of abuse. This rapidly emerging class of drug-sensing wearable devices addresses the growing demand for personalized medicine, toward improved therapeutic outcomes while minimizing the side effects of drugs and the related medical expenses. Continuous, noninvasive monitoring of therapeutic drugs within bodily fluids empowers clinicians and patients to correlate the pharmacokinetic properties with optimal outcomes by realizing patient-specific dose regulation and tracking dynamic changes in pharmacokinetics behavior while assuring the medication adherence of patients. Furthermore, wearable electrochemical drug monitoring devices can also serve as powerful screening tools in the hands of law enforcement agents to combat drug trafficking and support on-site forensic investigations. The review covers various wearable form factors developed for noninvasive monitoring of therapeutic drugs in different body fluids and toward on-site screening of drugs of abuse. The future prospects of such wearable drug monitoring devices are presented with the ultimate goals of introducing accurate real-time drug monitoring protocols and autonomous closed-loop platforms toward precise dose regulation and optimal therapeutic outcomes. Finally, current unmet challenges and existing gaps are discussed for motivating future technological innovations regarding personalized therapy. The current pace of developments and the tremendous market opportunities for such wearable drug monitoring platforms are expected to drive intense future research and commercialization efforts.
- 21 August 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (9) , 2679-2700
Top Cited PapersWearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Wearable electrochemical sensors capable of noninvasive monitoring of chemical markers represent a rapidly emerging digital-health technology. Recent advances toward wearable continuous glucose monitoring (CGM) systems have ignited tremendous interest in expanding such sensor technology to other important fields. This article reviews for the first time wearable electrochemical sensors for monitoring therapeutic drugs and drugs of abuse. This rapidly emerging class of drug-sensing wearable devices addresses the growing demand for personalized medicine, toward improved therapeutic outcomes while minimizing the side effects of drugs and the related medical expenses. Continuous, noninvasive monitoring of therapeutic drugs within bodily fluids empowers clinicians and patients to correlate the pharmacokinetic properties with optimal outcomes by realizing patient-specific dose regulation and tracking dynamic changes in pharmacokinetics behavior while assuring the medication adherence of patients. Furthermore, wearable electrochemical drug monitoring devices can also serve as powerful screening tools in the hands of law enforcement agents to combat drug trafficking and support on-site forensic investigations. The review covers various wearable form factors developed for noninvasive monitoring of therapeutic drugs in different body fluids and toward on-site screening of drugs of abuse. The future prospects of such wearable drug monitoring devices are presented with the ultimate goals of introducing accurate real-time drug monitoring protocols and autonomous closed-loop platforms toward precise dose regulation and optimal therapeutic outcomes. Finally, current unmet challenges and existing gaps are discussed for motivating future technological innovations regarding personalized therapy. The current pace of developments and the tremendous market opportunities for such wearable drug monitoring platforms are expected to drive intense future research and commercialization efforts.
- Top Cited Papers
- 4 May 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (6) , 1804-1813
Epidermal Enzymatic Biosensors for Sweat Vitamin C: Toward Personalized Nutrition
Recent advances in wearable sensor technologies offer new opportunities for improving dietary adherence. However, despite their tremendous promise, the potential of wearable chemical sensors to guide personalized nutrition solutions has not been reported. Here we present an epidermal biosensor aimed at following the dynamics of sweat vitamin C after intakes of vitamin C pills and fruit juices. Such skin-worn non-invasive electrochemical detection of sweat vitamin C has been realized by immobilizing the enzyme ascorbate oxidase (AAOx) on flexible printable tattoo electrodes and monitoring changes in the vitamin C level through changes in reduction current of the oxygen co-substrate. The flexible vitamin C tattoo patch was fabricated on a polyurethane substrate and combined with a localized iontophoretic sweat stimulation system along with amperometric cathodic detection of the oxygen depletion during the enzymatic reaction. The enzyme biosensor offers highly selective response compared to common direct (non-enzymatic) voltammetric measurements, with no effect of electroactive species such as uric acid or acetaminophen. Temporal vitamin C profiles in sweat are demonstrated using different subjects taking varying amounts of commercial vitamin C pills or vitamin C-rich beverages. The dynamic rise and fall of such vitamin C sweat levels are thus demonstrated with no interference from other sweat constituents. Differences in such dynamics among the individual subjects indicate the potential of the epidermal biosensor for personalized nutrition solutions. The flexible tattoo patch displayed mechanical resiliency to multiple stretching and bending deformations. In addition, the AAOx biosensor is shown useful as a disposable strip for rapid in-vitro detection of vitamin C in untreated raw saliva and tears following pill or juice intakes. These results demonstrate the potential of wearable chemical sensors for non-invasive nutrition status assessments and tracking of nutrient uptake toward detecting and correcting nutritional deficiencies, assessing adherence to vitamin intake, and supporting dietary behavior change.
- 4 May 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (6) , 1804-1813
Top Cited PapersEpidermal Enzymatic Biosensors for Sweat Vitamin C: Toward Personalized Nutrition
Recent advances in wearable sensor technologies offer new opportunities for improving dietary adherence. However, despite their tremendous promise, the potential of wearable chemical sensors to guide personalized nutrition solutions has not been reported. Here we present an epidermal biosensor aimed at following the dynamics of sweat vitamin C after intakes of vitamin C pills and fruit juices. Such skin-worn non-invasive electrochemical detection of sweat vitamin C has been realized by immobilizing the enzyme ascorbate oxidase (AAOx) on flexible printable tattoo electrodes and monitoring changes in the vitamin C level through changes in reduction current of the oxygen co-substrate. The flexible vitamin C tattoo patch was fabricated on a polyurethane substrate and combined with a localized iontophoretic sweat stimulation system along with amperometric cathodic detection of the oxygen depletion during the enzymatic reaction. The enzyme biosensor offers highly selective response compared to common direct (non-enzymatic) voltammetric measurements, with no effect of electroactive species such as uric acid or acetaminophen. Temporal vitamin C profiles in sweat are demonstrated using different subjects taking varying amounts of commercial vitamin C pills or vitamin C-rich beverages. The dynamic rise and fall of such vitamin C sweat levels are thus demonstrated with no interference from other sweat constituents. Differences in such dynamics among the individual subjects indicate the potential of the epidermal biosensor for personalized nutrition solutions. The flexible tattoo patch displayed mechanical resiliency to multiple stretching and bending deformations. In addition, the AAOx biosensor is shown useful as a disposable strip for rapid in-vitro detection of vitamin C in untreated raw saliva and tears following pill or juice intakes. These results demonstrate the potential of wearable chemical sensors for non-invasive nutrition status assessments and tracking of nutrient uptake toward detecting and correcting nutritional deficiencies, assessing adherence to vitamin intake, and supporting dietary behavior change.
- Top Cited Papers
- 24 December 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (2) , 2291-2300
Microneedle-Based Detection of Ketone Bodies along with Glucose and Lactate: Toward Real-Time Continuous Interstitial Fluid Monitoring of Diabetic Ketosis and Ketoacidosis
Diabetic ketoacidosis (DKA), a severe complication of diabetes mellitus with potentially fatal consequences, is characterized by hyperglycemia and metabolic acidosis due to the accumulation of ketone bodies which requires people with diabetes to monitor both glucose and ketone bodies. However, despite major advances in diabetes management mainly since the emergence of new-generation continuous glucose monitoring (CGM) devices capable of in-vivo monitoring of glucose directly in the interstitial fluid (ISF), the continuous monitoring of ketone bodies is yet to be addressed. Here, we present the first use of a real-time continuous ketone bodies monitoring (CKM) microneedle platform. The system is based on the electrochemical monitoring of β-hydroxybutyrate (HB), as the dominant biomarker of ketone formation. Such a real-time assay has been realized using the β-hydroxybutyrate dehydrogenase (HBD) enzymatic reaction and by addressing the major challenges associated with the stable confinement of the enzyme/cofactor couple (HBD/NAD+) and with a stable and selective low-potential fouling-free anodic detection of NADH. The resulting CKM microneedle device displays an attractive analytical performance, with high sensitivity (with low detection limit, 50 μM), high selectivity in the presence of potential interferences, along with good stability during prolonged operation in artificial ISF. The potential applicability of this microneedle sensor toward minimally-invasive monitoring of ketone bodies has been demonstrated in phantom gel skin-mimicking model. The ability to detect HB along with glucose and lactate on a single microneedle array has been demonstrated. These findings pave the way for CKM and for the simultaneous microneedle-based monitoring of multiple diabetes-related biomarkers toward a tight glycemic control.
- 24 December 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (2) , 2291-2300
Top Cited PapersMicroneedle-Based Detection of Ketone Bodies along with Glucose and Lactate: Toward Real-Time Continuous Interstitial Fluid Monitoring of Diabetic Ketosis and Ketoacidosis
Diabetic ketoacidosis (DKA), a severe complication of diabetes mellitus with potentially fatal consequences, is characterized by hyperglycemia and metabolic acidosis due to the accumulation of ketone bodies which requires people with diabetes to monitor both glucose and ketone bodies. However, despite major advances in diabetes management mainly since the emergence of new-generation continuous glucose monitoring (CGM) devices capable of in-vivo monitoring of glucose directly in the interstitial fluid (ISF), the continuous monitoring of ketone bodies is yet to be addressed. Here, we present the first use of a real-time continuous ketone bodies monitoring (CKM) microneedle platform. The system is based on the electrochemical monitoring of β-hydroxybutyrate (HB), as the dominant biomarker of ketone formation. Such a real-time assay has been realized using the β-hydroxybutyrate dehydrogenase (HBD) enzymatic reaction and by addressing the major challenges associated with the stable confinement of the enzyme/cofactor couple (HBD/NAD+) and with a stable and selective low-potential fouling-free anodic detection of NADH. The resulting CKM microneedle device displays an attractive analytical performance, with high sensitivity (with low detection limit, 50 μM), high selectivity in the presence of potential interferences, along with good stability during prolonged operation in artificial ISF. The potential applicability of this microneedle sensor toward minimally-invasive monitoring of ketone bodies has been demonstrated in phantom gel skin-mimicking model. The ability to detect HB along with glucose and lactate on a single microneedle array has been demonstrated. These findings pave the way for CKM and for the simultaneous microneedle-based monitoring of multiple diabetes-related biomarkers toward a tight glycemic control.
- 2 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 53 (7) , 2043-2053
A Battery-Powered Wireless Ion Sensing System Consuming 5.5 nW of Average Power
This paper presents a battery-powered wireless ion sensing platform featuring complete sensing-to-transmission functionality. A 1 mm × 1.2 mm chip fabricated in 65 nm includes a 406 pW potentiometric analog front end, a 780 pW 10-bit SAR ADC, a 2.4 GHz power-oscillator-based wireless transmitter that consumes an average of 2.4 nW during a 10-sample/sec transmission rate, two timing generation oscillators that each consume 140 pW, and a 3:1 switched-capacitor dc-dc converter with 485 pW of quiescent power that achieves the efficiencies of 96.8% and 70.5% at 60 and 3.9 nW loads, respectively. The chip connects to a screen-printed ion-selective electrode responsive to sodium ions, and in vitro testing across an NaCl solution concentration range of 0.1-100 mM exhibited a linear near-Nernstian response with a slope of 71 mV/log10[Na + ]. When all blocks are operating, the system consumes an average of 5.5 nW.
- 2 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 53 (7) , 2043-2053
A Battery-Powered Wireless Ion Sensing System Consuming 5.5 nW of Average Power
This paper presents a battery-powered wireless ion sensing platform featuring complete sensing-to-transmission functionality. A 1 mm × 1.2 mm chip fabricated in 65 nm includes a 406 pW potentiometric analog front end, a 780 pW 10-bit SAR ADC, a 2.4 GHz power-oscillator-based wireless transmitter that consumes an average of 2.4 nW during a 10-sample/sec transmission rate, two timing generation oscillators that each consume 140 pW, and a 3:1 switched-capacitor dc-dc converter with 485 pW of quiescent power that achieves the efficiencies of 96.8% and 70.5% at 60 and 3.9 nW loads, respectively. The chip connects to a screen-printed ion-selective electrode responsive to sodium ions, and in vitro testing across an NaCl solution concentration range of 0.1-100 mM exhibited a linear near-Nernstian response with a slope of 71 mV/log10[Na + ]. When all blocks are operating, the system consumes an average of 5.5 nW.