T. M. Schindler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
T. M. Schindler has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Angelica Ottaviano
TAE Technologies, Inc., Foothill Ranch, California 92610, USA
3 shared publications - Kan Zhai
TAE Technologies, Inc., Foothill Ranch, California 92610, USA
3 shared publications - Matthew C Thompson
TAE Technologies, Inc., Foothill Ranch, California 92610, USA
3 shared publications Tae Team
TAE Technologies, Inc., Foothill Ranch, California 92610, USA
3 shared publicationsE. Parke
TAE Technologies, Inc., Foothill Ranch, California 92610, USA
2 shared publications- Hiroshi Gota
TAE Technologies, Inc
2 shared publications
Latest Publications
- 1 October 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (10) , 106039
Overview of C-2W: high temperature, steady-state beam-driven field-reversed configuration plasmas
- 1 October 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (10) , 106039
Overview of C-2W: high temperature, steady-state beam-driven field-reversed configuration plasmas
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10C120
Characterization and calibration of the Thomson scattering diagnostic suite for the C-2W field-reversed configuration experiment
The new C-2W Thomson scattering (TS) diagnostic consists of two individual subsystems for monitoring electron temperature (Te) and density (ne): one system in the central region is currently operational, and the second system is being commissioned to monitor the open field line region. Validating the performance of the TS’s custom designed system components and unique calibration of the detection system and diagnostic as a whole is crucial to obtaining high precision Te and ne profiles of C-2W’s plasma. The major components include a diode-pumped Nd:YAG laser which produces 35 pulses at up to 20 kHz, uniquely designed collection lenses with a fast numerical aperture, and uniquely designed polychromators with filters sets to optimize a Te ranging from 10 eV to 2 keV. This paper describes the design principles and techniques used to characterize the main components of the TS diagnostic on C-2W, as well as the results of Rayleigh scattering calibrations performed for the whole system response.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10C120
Characterization and calibration of the Thomson scattering diagnostic suite for the C-2W field-reversed configuration experiment
The new C-2W Thomson scattering (TS) diagnostic consists of two individual subsystems for monitoring electron temperature (Te) and density (ne): one system in the central region is currently operational, and the second system is being commissioned to monitor the open field line region. Validating the performance of the TS’s custom designed system components and unique calibration of the detection system and diagnostic as a whole is crucial to obtaining high precision Te and ne profiles of C-2W’s plasma. The major components include a diode-pumped Nd:YAG laser which produces 35 pulses at up to 20 kHz, uniquely designed collection lenses with a fast numerical aperture, and uniquely designed polychromators with filters sets to optimize a Te ranging from 10 eV to 2 keV. This paper describes the design principles and techniques used to characterize the main components of the TS diagnostic on C-2W, as well as the results of Rayleigh scattering calibrations performed for the whole system response.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10C118
Thomson scattering systems on C-2W field-reversed configuration plasma experiment
TAE Technologies’ newly constructed C-2W experiment aims to improve the ion and electron temperatures in a sustained field-reversed configuration plasma. A suite of Thomson scattering systems has been designed and constructed for electron temperature and density profile measurements. The systems are designed for electron densities of 1 × 1012 cm−3 to 2 × 1014 cm−3 and temperature ranges from 10 eV to 2 keV. The central system will provide profile measurements of Te and ne at 16 radial locations from r = −9 cm to r = 64 cm with a temporal resolution of 20 kHz for 4 pulses or 1 kHz for 30 pulses. The jet system will provide profile measurements of Te and ne at 5 radial locations in the open field region from r = −5 cm to r = 15 cm with a temporal resolution of 100 Hz. The central system and its components have been characterized, calibrated, installed, and commissioned. A maximum-likelihood algorithm has been applied for data processing and analysis.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10C118
Thomson scattering systems on C-2W field-reversed configuration plasma experiment
TAE Technologies’ newly constructed C-2W experiment aims to improve the ion and electron temperatures in a sustained field-reversed configuration plasma. A suite of Thomson scattering systems has been designed and constructed for electron temperature and density profile measurements. The systems are designed for electron densities of 1 × 1012 cm−3 to 2 × 1014 cm−3 and temperature ranges from 10 eV to 2 keV. The central system will provide profile measurements of Te and ne at 16 radial locations from r = −9 cm to r = 64 cm with a temporal resolution of 20 kHz for 4 pulses or 1 kHz for 30 pulses. The jet system will provide profile measurements of Te and ne at 5 radial locations in the open field region from r = −5 cm to r = 15 cm with a temporal resolution of 100 Hz. The central system and its components have been characterized, calibrated, installed, and commissioned. A maximum-likelihood algorithm has been applied for data processing and analysis.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10K114
Integrated diagnostic and data analysis system of the C-2W advanced beam-driven field-reversed configuration plasma experiment
The new C-2W experiment (also called Norman) at TAE Technologies, Inc. studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes over 700 magnetic sensors, four interferometer systems, multi-chord far-infrared polarimetry, two Thomson scattering systems, ten types of spectroscopic measurements, multiple fast imaging cameras with selectable atomic line filters, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. Most of these diagnostic systems are newly built using experience and data from the preceding C-2U experiment to guide the design process. A variety of commercial and custom acquisition electronics collect over 4000 raw signals from the C-2W diagnostics. These data are processed into physics results using a large-scale database of diagnostics metadata and analysis software, both built using open-source software tools.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10K114
Integrated diagnostic and data analysis system of the C-2W advanced beam-driven field-reversed configuration plasma experiment
The new C-2W experiment (also called Norman) at TAE Technologies, Inc. studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes over 700 magnetic sensors, four interferometer systems, multi-chord far-infrared polarimetry, two Thomson scattering systems, ten types of spectroscopic measurements, multiple fast imaging cameras with selectable atomic line filters, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. Most of these diagnostic systems are newly built using experience and data from the preceding C-2U experiment to guide the design process. A variety of commercial and custom acquisition electronics collect over 4000 raw signals from the C-2W diagnostics. These data are processed into physics results using a large-scale database of diagnostics metadata and analysis software, both built using open-source software tools.
- 1 October 2007
- Published by Wiley in Vakuum in Forschung und Praxis
- Vol. 19 (5) , 24-30
Ultra‐precision Surface Finishing by Ion Beam Techniques
Ion beam etching based ultra precision surface finishing is a versatile technology with a high degree of predictability due to the high stability of state of the art ion sources and the acquired knowledge of the physics of beam surface interaction. The independent control of the ion energy and the ion current density over wide ranges and the possible additional use of chemical reactive species in combination with physical sputter removal allow solving tasks in a wide variety of applications. The paper summarizes the present status of more than 20 years of development of ion beam finishing technology in IOM. It gives an overview on the equipment and the components developed for production purposes and on the ion beam technologies developed to achieve nanometer and sub‐nanometer depth accuracies over the entire spectrum of spatial surface wavelength from the full aperture size down to the microroughness level of only micrometer lateral feature size. Results of the finishing of high‐end optical surfaces shown demonstrate the outstanding performances of the techniques with topography and roughness control on the atomic scale.
- 1 October 2007
- Published by Wiley in Vakuum in Forschung und Praxis
- Vol. 19 (5) , 24-30
Ultra‐precision Surface Finishing by Ion Beam Techniques
Ion beam etching based ultra precision surface finishing is a versatile technology with a high degree of predictability due to the high stability of state of the art ion sources and the acquired knowledge of the physics of beam surface interaction. The independent control of the ion energy and the ion current density over wide ranges and the possible additional use of chemical reactive species in combination with physical sputter removal allow solving tasks in a wide variety of applications. The paper summarizes the present status of more than 20 years of development of ion beam finishing technology in IOM. It gives an overview on the equipment and the components developed for production purposes and on the ion beam technologies developed to achieve nanometer and sub‐nanometer depth accuracies over the entire spectrum of spatial surface wavelength from the full aperture size down to the microroughness level of only micrometer lateral feature size. Results of the finishing of high‐end optical surfaces shown demonstrate the outstanding performances of the techniques with topography and roughness control on the atomic scale.