Hamid Saeed Raza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hamid Saeed Raza has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Sung Oh Cho
Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST) , Daejeon 305-701, Republic of Korea
3 shared publicationsHyun Jin Kim
2 shared publicationsJun Mok Ha
Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST) , Daejeon 305-701, Republic of Korea
2 shared publications- Abdul Samad
School of Information and Electronics, Beijing Institute of Technology (BIT), Beijing 100081, China
1 shared publication Deliang Chen
Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
1 shared publication- Ghafar Ali
Nanomaterials Research Group (NRG), Physics Division, PINSTECH, Nilore, Islamabad, Pakistan
1 shared publication
Latest Publications
- Open Access
- 10 November 2020
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 14 (15) , 2064-2073
Design of highly sensitive complementary metamaterial‐based microwave sensor for characterisation of dielectric materials
Metamaterial‐based double‐slit complementary split rectangular resonator sensor is proposed for the characterisation of dielectric properties of the materials under test (MUTs). The proposed sensor is designed and simulated on the CST microwave studio software using a low‐cost substrate FR4. An array of three identical resonators is etched in the ground plane of the sensor to achieve a single and deep notch of −58.7 dB in the transmission coefficient ( S 21 ) at the resonant frequency of 7.01 GHz, which is the novelty of the proposed sensor. A deep and single resonant frequency band has a significant role in the precise measurement of the dielectric properties of the MUTs. The effective constitutive parameters are extracted from the S ‐parameters. An equivalent circuit model is suggested that describes the overall behaviour of the sensor. The sensor is fabricated on the FR4 substrate and measured through the vector network analyser (N5224B) by placing the standard materials. The parabolic equation for the proposed sensor is formulated to approximate the permittivity of the MUTs. A very small percentage of error, 0.77, is found which shows high accuracy of the sensor. This methodology is efficient, simple in fabrication, and reduces cost and computational time also.
- 10 November 2020
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 14 (15) , 2064-2073
Open AccessDesign of highly sensitive complementary metamaterial‐based microwave sensor for characterisation of dielectric materials
Metamaterial‐based double‐slit complementary split rectangular resonator sensor is proposed for the characterisation of dielectric properties of the materials under test (MUTs). The proposed sensor is designed and simulated on the CST microwave studio software using a low‐cost substrate FR4. An array of three identical resonators is etched in the ground plane of the sensor to achieve a single and deep notch of −58.7 dB in the transmission coefficient ( S 21 ) at the resonant frequency of 7.01 GHz, which is the novelty of the proposed sensor. A deep and single resonant frequency band has a significant role in the precise measurement of the dielectric properties of the MUTs. The effective constitutive parameters are extracted from the S ‐parameters. An equivalent circuit model is suggested that describes the overall behaviour of the sensor. The sensor is fabricated on the FR4 substrate and measured through the vector network analyser (N5224B) by placing the standard materials. The parabolic equation for the proposed sensor is formulated to approximate the permittivity of the MUTs. A very small percentage of error, 0.77, is found which shows high accuracy of the sensor. This methodology is efficient, simple in fabrication, and reduces cost and computational time also.
- 25 July 2016
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 8 (30) , 19192-19196
Effect of Electron-Beam Irradiation on Organic Semiconductor and Its Application for Transistor-Based Dosimeters
The effects of electron beam irradiation on organic semiconductor rubrene and its application as a dosimeter has been studied. Through the measurements of photoluminescence and the ultraviolet photoelectron spectroscopy spectra, we found that electron beam irradiation induces n-doping of rubrene. Additionally, we fabricated rubrene thin-film transistors with pristine and irradiated rubrene thin-film. By comparisons, we could discover that the decrease of transistor properties are originated from the irradiation of rubrene and the threshold voltages are shifted to the opposite directions as the irradiated layers. Finally, highly sensitive and air-stable dosimeter of electron beam was suggested based on rubrene transistor.
- 25 July 2016
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 8 (30) , 19192-19196
Effect of Electron-Beam Irradiation on Organic Semiconductor and Its Application for Transistor-Based Dosimeters
The effects of electron beam irradiation on organic semiconductor rubrene and its application as a dosimeter has been studied. Through the measurements of photoluminescence and the ultraviolet photoelectron spectroscopy spectra, we found that electron beam irradiation induces n-doping of rubrene. Additionally, we fabricated rubrene thin-film transistors with pristine and irradiated rubrene thin-film. By comparisons, we could discover that the decrease of transistor properties are originated from the irradiation of rubrene and the threshold voltages are shifted to the opposite directions as the irradiated layers. Finally, highly sensitive and air-stable dosimeter of electron beam was suggested based on rubrene transistor.
- Open Access
- 1 June 2016
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 48 (3) , 799-804
An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography
- 1 June 2016
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 48 (3) , 799-804
Open AccessAn Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography
- 1 October 2013
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 80, 67-72
Behavior of characteristic X-rays from a partial-transmission-type X-ray target
- 1 October 2013
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 80, 67-72
Behavior of characteristic X-rays from a partial-transmission-type X-ray target
- 25 July 2012
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 14 (8) , 1-11
Formation of hierarchical TiO2 nanoporous structure from free-standing TiO2 nanotubes layers
- 25 July 2012
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 14 (8) , 1-11
Formation of hierarchical TiO2 nanoporous structure from free-standing TiO2 nanotubes layers