SCSanjian Chen

Sanjian Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sanjian Chen has a total of 55 co-authors. Here are the top co-authors by number of shared publications:

  • Insup Lee

    Department of Computer and Information Science, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, Pennsylvania

    17 shared publications
  • Oleg Sokolsky

    University of Pennsylvania, Philadelphia, PA 19104-6389 USA

    10 shared publications
  • James Weimer

    Department of Computer and Information Science, University of Pennsylvania , Philadelphia, Pennsylvania

    4 shared publications
  • Alexander Roederer

    University of Pennsylvania, Philadelphia, PA 19104-6389 USA

    3 shared publications
  • Michael R. Rickels

    Division of Endocrinology, Diabetes and Metabolism, Department of Medicine, and Institute for Diabetes, Obesity and Metabolism, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA

    3 shared publications
  • Amy Peleckis

    Division of Endocrinology, Diabetes and Metabolism, Perelman School of Medicine, University of Pennsylvania , Philadelphia, Pennsylvania

    2 shared publications

Latest Publications

  • Open Access

    Continuous Glucose Monitoring for Hypoglycemia Avoidance and Glucose Counterregulation in Long-Standing Type 1 Diabetes

    by Michael R Rickels, Amy J Peleckis, Cornelia Dalton-Bakes, Joseph R Naji, Nina A Ran, Huong-Lan Nguyen, Shannon O’brien, Sanjian Chen, Insup Lee, Mark H Schutta

    Context Patients with long standing type 1 diabetes (T1D) are at increased risk for severe hypoglycemia due to defects in glucose counterregulation and hypoglycemia symptom recognition, in part mediated through exposure to hypoglycemia. Objective To determine whether implementation of real-time continuous glucose monitoring (CGM) as a strategy for hypoglycemia avoidance could improve glucose counterregulation in patients with long standing T1D complicated by hypoglycemia unawareness. Design, Setting, Participants, and Intervention Eleven patients with T1D disease duration ∼31 years were studied longitudinally in the Clinical & Translational Research Center of the University of Pennsylvania before and 6 and 18 months after initiation of CGM, and compared to 12 nondiabetic control subjects. Main Outcome Measure Endogenous glucose production response derived from paired hyperinsulinemic stepped-hypoglycemic and euglycemic clamps with infusion of 6,6-2H2-glucose. Results The T1D subjects experienced improvement in hypoglycemia awareness (Clarke score) and severity (HYPO score and severe events; P 1c (baseline 7.2 ± 0.2%). In response to insulin-induced hypoglycemia, endogenous glucose production did not change from before to 6 months (0.42 ± 0.08 vs. 0.54 ± 0.07 mg·kg-1·min-1), but improved after 18 months (0.84 ± 0.15 mg·kg-1·min-1; P -1·min-1; P ≤0.01 vs. all). Conclusions Real-time CGM can improve awareness and reduce the burden of problematic hypoglycemia in patients with long standing T1D, but with only modest improvement in the endogenous glucose production response that is required to prevent or correct low blood glucose.


  • Parameter-Invariant Monitor Design for Cyber–Physical Systems

    by James Weimer, Radoslav Ivanov, Sanjian Chen, Alexander Roederer, Oleg Sokolsky, Insup Lee

    The tight interaction between information technology and the physical world inherent in cyber-physical systems (CPS) can challenge traditional approaches for monitoring safety and security. Data collected for robust CPS monitoring is often sparse and may lack rich training data describing critical events/attacks. Moreover, CPS often operate in diverse environments that can have significant inter/intra-system variability. Furthermore, CPS monitors that are not robust to data sparsity and inter/intra-system variability may result in inconsistent performance and may not be trusted for monitoring safety and security. Towards overcoming these challenges, this paper presents recent work on the design of parameter-invariant (PAIN) monitors for CPS. PAIN monitors are designed such that unknown events and system variability minimally affect the monitor performance. This work describes how PAIN designs can achieve a constant false alarm rate (CFAR) in the presence of data sparsity and intra/inter system variance in real-world CPS. To demonstrate the design of PAIN monitors for safety monitoring in CPS with different types of dynamics, we consider systems with networked dynamics, linear-time invariant dynamics, and hybrid dynamics that are discussed through case studies for building actuator fault detection, meal detection in type I diabetes, and detecting hypoxia caused by pulmonary shunts in infants. In all applications, the PAIN monitor is shown to have (significantly) less variance in monitoring performance and (often) outperforms other competing approaches in the literature. Finally, an initial application of PAIN monitoring for CPS security is presented along with challenges and research directions for future security monitoring deployments.


  • Physiology-Invariant Meal Detection for Type 1 Diabetes

    by James Weimer, Sanjian Chen, Amy Peleckis, Michael R. Rickels, Insup Lee

    Background: Fully automated artificial pancreas systems require meal detectors to supplement blood glucose level regulation, where false meal detections can cause unnecessary insulin delivery with potentially fatal consequences, and missed detections may cause the patient to experience extreme hyperglycemia. Most existing meal detectors monitor various measures of glucose rate-of-change to detect meals where varying physiology and meal content complicate balancing detector sensitivity versus specificity. Methods: We developed a novel meal detector based on a minimal glucose–insulin metabolism model and show that the detector is, by design, invariant to patient-specific physiological parameters in the minimal model. Our physiological parameter-invariant (PAIN) detector achieves a near-constant false alarm rate across all individuals and is evaluated against three other major existing meal detectors on a clinical type 1 diabetes data set. Results: In the clinical evaluation, the PAIN-based detector achieves an 86.9% sensitivity for an average false alarm rate of two alarms per day. In addition, for all false alarm rates, the PAIN-based detector performance is significantly better than three other existing meal detectors. In addition, the evaluation results show that the PAIN-based detector uniquely (as compared with the other meal detectors) has low variance in detection and false alarm rates across all patients, without patient-specific personalization. Conclusions: The PAIN-based meal detector has demonstrated better detection performance than existing meal detectors, and it has the unique strength of achieving a consistent performance across a population with varying physiology without any individual-level parameter tuning or training.


  • Towards Assurance for Plug & Play Medical Systems

    by Andrew L. King, Lu Feng, Sam Procter, Sanjian Chen, Oleg Sokolsky, John Hatcliff, Insup Lee


  • A Data-Driven Behavior Modeling and Analysis Framework for Diabetic Patients on Insulin Pumps

    by Sanjian Chen, Lu Feng, Michael R. Rickels, Amy Peleckis, Oleg Sokolsky, Insup Lee

    About 30%-40% of Type 1 Diabetes (T1D) patients in the United States use insulin pumps. Current insulin infusion systems require users to manually input meal carb count and approve or modify the system-suggested meal insulin dose. Users can give correction insulin boluses at any time. Since meal carbohydrates and insulin are the two main driving forces of the glucose physiology, the user-specific eating and pump-using behavior has a great impact on the quality of glycemic control. In this paper, we propose an "Eat, Trust, and Correct" (ETC) framework to model the T1D insulin pump users' behavior. We use machine learning techniques to analyze the user behavior from a clinical dataset that we collected on 55 T1D patients who use insulin pumps. We demonstrate the usefulness of the ETC behavior modeling framework by performing in silico experiments. To this end, we integrate the user behavior model with an individually parameterized glucose physiological model, and perform probabilistic model checking on the user-in-the-loop system. The experimental results show that switching behavior types can significantly improve a patient's glycemic control outcomes. These analysis results can boost the effectiveness of T1D patient education and peer support.


  • Parameter-Invariant Design of Medical Alarms

    by James Weimer, Radoslav Ivanov, Alexander Roederer, Sanjian Chen, Insup Lee

    In this tutorial, we present a design methodology for medical parameter-invariant monitors. We begin by providing a motivational review of currently employed medical alarm techniques, followed by the introduction of the parameter-invariant design approach. Finally, we present a case study example to demonstrate the design of a parameter-invariant alarm for critical shunt detection in infants during surgical procedures.


  • An Intraoperative Glucose Control Benchmark for Formal Verification

    by Sanjian Chen, Matthew O'Kelly, James Weimer, Oleg Sokolsky, Insup Lee


  • The MIDdleware Assurance Substrate: Enabling Strong Real-Time Guarantees in Open Systems with OpenFlow

    by Andrew L. King, Sanjian Chen, Insup Lee

    Middleware designed for use in Distributed Real-Time and Embedded (DRE) systems enable cost and development time reductions by providing simple communications abstractions and hiding operating system-level networking API details from developers. While current middleware technologies can hide many low-level details, designers must provide a static configuration for the system's underlying network in order to achieve required performance characteristics. This has not been a problem for many types of DRE systems where the configuration of the system is relatively fixed from the factory (e.g., aircraft or naval vessels). However for truly open systems (i.e., systems where end users can add or substract components at runtime)the standard static network configuration approach cannot guarantee that required performance will be met because network resource demands are not fully known a priori. Open systems with stringent performance requirements need middleware that can dynamically manage the underlying network configuration automatically in response to changing demands. Fortunately, recent trends in networking have resulted in a wide variety of networking equipment that expose a standardized low-level interface to their configuration via the OpenFlow protocol. In this paper we discuss how OpenFlow can be leveraged by DRE middleware to automatically provide performance guarantees. In order to make the discussion concrete, we describe the architecture of our prototype middleware MIDAS as well as the details of one example network resource management strategy. We demonstrate the feasibility of our approach via performance assesment of a simple DRE application using our MIDAS and commerically available OpenFlow hardware.


  • Distributed aspects of the artificial pancreas

    by Stephen D. Patek, Sanjian Chen, Patrick Keith-Hynes, Insup Lee

    Type 1 diabetes (T1D) is a disease caused by the autoimmune destruction of the pancreatic beta cells, permanently disrupting endogenous insulin secretion and requiring patients to inject or infuse insulin to keep blood sugar levels close to normal. Self-treatment of T1D can be regarded as a closed-loop control system with a significant “human-in-the-loop” aspect. Artificial pancreas systems seek to both improve glycemic outcomes and reduce cognitive burden associated with self-treatment by taking advantage of modern glucose monitoring and insulin pump technology. While the systems that have been proposed so far differ in the nature and extent of patient interaction, all such systems involve closing the feedback loop through a portable computational platform with wireless access to both sensors and actuators. In this paper, we review recent developments in the field, focusing on the opportunities and hazards associated with (i) distributed implementation of artificial pancreas algorithms and (ii) shared human-machine control of insulin delivery.