Ali Koçak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ali Koçak has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Erdoğan1 shared publication
- António Araújo Correia
National Laboratory for Civil Engineering (LNEC)
1 shared publication - Murat Ergenokon Selçuk
Yıldız Teknik Üniversitesi
1 shared publication - Onur Onat
Department of Civil Engineering, Inonu University, Battalgazi, Malatya, Türkiye
1 shared publication - Paulo Barbosa Lourenco
University of Minho
1 shared publication - Recep Balim1 shared publication
Latest Publications
- 30 November 2026
- Published by Turkish Academy of Sciences
- p. 1-56
Türkiye’de Depremler Sonrası Görülen Yapı Hasarları, Nedenleri ve Mevcut Yapı Stoğu
Located in an active seismic zone, Türkiye has experienced devastating earthquakes throughout its history, demonstrating that a significant portion of the existing building stock lacks sufficient resistance to large-scale earthquakes. In particular, the earthquakes between 1992 Erzincan and 2023 Kahramanmaraş resulted in extremely high levels of structural damage and loss of life. These outcomes have led recent studies to focus on the existing building stock, questioning design and construction practices. The practice of architects and civil engineers undertaking architectural and structural design without distinction has been replaced by a legal framework where each professional discipline became legally recognized as the responsible design authority within its own field. Subsequently, the Building Inspection Law became effective, but due to shortcomings in its implementation, amendments were made to the law, transferring public inspection authority to Building Inspection Firms. While this has increased the effectiveness of inspection services and led to buildings being designed according to stricter, updated regulations, destruction and loss of life continue. Recently, buildings that collapsed under their own weight or during renovations carried out without permission from the relevant local authorities have also been reported. This situation indicates that legal regulations regarding building construction are insufficient or that existing regulations are not fully implemented. Within the scope of this study, firstly, data related to earthquakes and the root causes and consequences of earthquake damage were examined. Then, as an application example, the earthquake performance analyses of a reinforced concrete building constructed without engineering services and not meeting the regulations of its construction year were compared with a modeled version according to current regulations. As a result of the study, the weaknesses of the existing building stock in high-risk areas were identified, the causal link between structural defects and damage was clearly demonstrated, and the aim was to contribute to the identification of legal responsibilities arising from technical deficiencies and to the creation of safe cities.
- 30 November 2026
- Published by Turkish Academy of Sciences
- p. 1-56
Türkiye’de Depremler Sonrası Görülen Yapı Hasarları, Nedenleri ve Mevcut Yapı Stoğu
Located in an active seismic zone, Türkiye has experienced devastating earthquakes throughout its history, demonstrating that a significant portion of the existing building stock lacks sufficient resistance to large-scale earthquakes. In particular, the earthquakes between 1992 Erzincan and 2023 Kahramanmaraş resulted in extremely high levels of structural damage and loss of life. These outcomes have led recent studies to focus on the existing building stock, questioning design and construction practices. The practice of architects and civil engineers undertaking architectural and structural design without distinction has been replaced by a legal framework where each professional discipline became legally recognized as the responsible design authority within its own field. Subsequently, the Building Inspection Law became effective, but due to shortcomings in its implementation, amendments were made to the law, transferring public inspection authority to Building Inspection Firms. While this has increased the effectiveness of inspection services and led to buildings being designed according to stricter, updated regulations, destruction and loss of life continue. Recently, buildings that collapsed under their own weight or during renovations carried out without permission from the relevant local authorities have also been reported. This situation indicates that legal regulations regarding building construction are insufficient or that existing regulations are not fully implemented. Within the scope of this study, firstly, data related to earthquakes and the root causes and consequences of earthquake damage were examined. Then, as an application example, the earthquake performance analyses of a reinforced concrete building constructed without engineering services and not meeting the regulations of its construction year were compared with a modeled version according to current regulations. As a result of the study, the weaknesses of the existing building stock in high-risk areas were identified, the causal link between structural defects and damage was clearly demonstrated, and the aim was to contribute to the identification of legal responsibilities arising from technical deficiencies and to the creation of safe cities.
- Open Access
- 20 May 2026
- Published by Elsevier in SSRN Electronic Journal
Seismic Response of a Vertically and Plan-Wise Irregular RC Building: Experimental Identification, Model Calibration, and Structural Behavior
This study investigates the seismic response of an existing reinforced concrete (RC) building exhibiting both vertical and plan-wise irregularities through an integrated framework combining experimental modal identification, finite element (FE) model calibration, and nonlinear time-history analysis (NTHA). The dynamic characteristics of the structure were identified using ambient vibration measurements, and modal parameters were extracted through operational modal analysis (OMA). A three-dimensional FE model was subsequently calibrated based on the experimentally derived modal properties, while the contribution of infill walls was incorporated using nonlinear equivalent strut models to enhance the accuracy of the analytical representation. Subsequently, nonlinear time-history analyses were performed using a set of real earthquake ground motion records applied in both original and rotated directions. The results reveal that structural irregularities—such as vertical load discontinuities, floating columns, and slab openings—lead to significant concentration of section demands and plastic hinge formations in localized regions. To isolate the effect of irregularities, an idealized regular configuration of the same structure, preserving material properties and overall geometry, was also analyzed under identical seismic inputs. The comparative results show that while global response parameters (e.g., base shear and displacement demands) may remain at similar levels, the underlying damage mechanisms and plastic hinge distributions differ substantially. The regular configuration exhibits a more uniform and predictable damage pattern with improved ductility and energy dissipation capacity. However, the redistribution of seismic forces results in localized increases in shear demand in certain elements, indicating that geometric regularization alone does not fully eliminate critical demand concentrations. Overall, the study demonstrates that structural irregularities primarily govern seismic performance through their influence on load transfer mechanisms and damage localization. The proposed integrated framework, combining experimental modal identification and FE model calibration, provides a reliable basis for the seismic assessment of existing irregular RC buildings.
- 20 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSeismic Response of a Vertically and Plan-Wise Irregular RC Building: Experimental Identification, Model Calibration, and Structural Behavior
This study investigates the seismic response of an existing reinforced concrete (RC) building exhibiting both vertical and plan-wise irregularities through an integrated framework combining experimental modal identification, finite element (FE) model calibration, and nonlinear time-history analysis (NTHA). The dynamic characteristics of the structure were identified using ambient vibration measurements, and modal parameters were extracted through operational modal analysis (OMA). A three-dimensional FE model was subsequently calibrated based on the experimentally derived modal properties, while the contribution of infill walls was incorporated using nonlinear equivalent strut models to enhance the accuracy of the analytical representation. Subsequently, nonlinear time-history analyses were performed using a set of real earthquake ground motion records applied in both original and rotated directions. The results reveal that structural irregularities—such as vertical load discontinuities, floating columns, and slab openings—lead to significant concentration of section demands and plastic hinge formations in localized regions. To isolate the effect of irregularities, an idealized regular configuration of the same structure, preserving material properties and overall geometry, was also analyzed under identical seismic inputs. The comparative results show that while global response parameters (e.g., base shear and displacement demands) may remain at similar levels, the underlying damage mechanisms and plastic hinge distributions differ substantially. The regular configuration exhibits a more uniform and predictable damage pattern with improved ductility and energy dissipation capacity. However, the redistribution of seismic forces results in localized increases in shear demand in certain elements, indicating that geometric regularization alone does not fully eliminate critical demand concentrations. Overall, the study demonstrates that structural irregularities primarily govern seismic performance through their influence on load transfer mechanisms and damage localization. The proposed integrated framework, combining experimental modal identification and FE model calibration, provides a reliable basis for the seismic assessment of existing irregular RC buildings.
- Open Access
- 19 May 2026
- Published by Elsevier in SSRN Electronic Journal
Experimental–Numerical Assessment of Tunneling-Induced Damage and Subsequent Seismic Vulnerability in an Unreinforced Masonry Building
Accurate assessment of damage in unreinforced masonry (URM) buildings requires reliable material characterization and realistic representation of sequential loading histories. Conventional evaluations often rely on generic literature or national code data, which may not reflect actual in-situ conditions. This study investigates the structural behavior of a two-story URM building constructed in 1961 in Sivas, Türkiye, which sustained visible cracking following the excavation of the Mevlana dual-bore vehicle tunnel passing approximately 9.4 m beneath its foundations. Notably, the cracking was first observed 2.5 to 3.5 years after tunnel completion, suggesting time-dependent consolidation effects in the underlying clay deposits. The investigation integrates laboratory testing of clay brick units, comparative analysis of 10 empirical formulas and international code provisions, and a comprehensive database of experimental masonry properties from 11 countries to establish representative material parameters (fm = 4 MPa, Em = 3000 MPa). A three-dimensional nonlinear finite element model is developed in Abaqus using the Concrete Damaged Plasticity (CDP) constitutive model. The influence of wall openings on stiffness is explicitly accounted for through calibrated Young's modulus reductions ranging from 2700 MPa to 600 MPa, derived from prior experimental studies. Tunneling-induced settlement profiles obtained from a Plaxis 3D soil–structure interaction analysis are imposed as boundary conditions on the structural model. The sequential analysis proceeds in three steps: (i) gravity loading, (ii) differential settlement due to tunnel excavation, and (iii) seismic excitation using the recorded ground motion of the 2023 Kahramanmaraş earthquake (Mw 7.7). The settlement-calibrated model accurately reproduces the observed crack locations and patterns, while the natural frequencies of the building decrease by 16–21% after the settlement step, confirming measurable stiffness degradation. A comparative study of two seismic scenarios—with and without prior settlement damage—reveals that although global displacement responses converge under strong motion (~23–24 cm), the pre-damaged model captures critical local vulnerabilities that remain undetected in the undamaged model. The findings underscore the necessity of integrating experimental data, realistic loading sequences, and local structural factors for robust forensic assessment and seismic vulnerability evaluation of existing masonry buildings.
- 19 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental–Numerical Assessment of Tunneling-Induced Damage and Subsequent Seismic Vulnerability in an Unreinforced Masonry Building
Accurate assessment of damage in unreinforced masonry (URM) buildings requires reliable material characterization and realistic representation of sequential loading histories. Conventional evaluations often rely on generic literature or national code data, which may not reflect actual in-situ conditions. This study investigates the structural behavior of a two-story URM building constructed in 1961 in Sivas, Türkiye, which sustained visible cracking following the excavation of the Mevlana dual-bore vehicle tunnel passing approximately 9.4 m beneath its foundations. Notably, the cracking was first observed 2.5 to 3.5 years after tunnel completion, suggesting time-dependent consolidation effects in the underlying clay deposits. The investigation integrates laboratory testing of clay brick units, comparative analysis of 10 empirical formulas and international code provisions, and a comprehensive database of experimental masonry properties from 11 countries to establish representative material parameters (fm = 4 MPa, Em = 3000 MPa). A three-dimensional nonlinear finite element model is developed in Abaqus using the Concrete Damaged Plasticity (CDP) constitutive model. The influence of wall openings on stiffness is explicitly accounted for through calibrated Young's modulus reductions ranging from 2700 MPa to 600 MPa, derived from prior experimental studies. Tunneling-induced settlement profiles obtained from a Plaxis 3D soil–structure interaction analysis are imposed as boundary conditions on the structural model. The sequential analysis proceeds in three steps: (i) gravity loading, (ii) differential settlement due to tunnel excavation, and (iii) seismic excitation using the recorded ground motion of the 2023 Kahramanmaraş earthquake (Mw 7.7). The settlement-calibrated model accurately reproduces the observed crack locations and patterns, while the natural frequencies of the building decrease by 16–21% after the settlement step, confirming measurable stiffness degradation. A comparative study of two seismic scenarios—with and without prior settlement damage—reveals that although global displacement responses converge under strong motion (~23–24 cm), the pre-damaged model captures critical local vulnerabilities that remain undetected in the undamaged model. The findings underscore the necessity of integrating experimental data, realistic loading sequences, and local structural factors for robust forensic assessment and seismic vulnerability evaluation of existing masonry buildings.
- 5 September 2018
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 47 (14) , 2821-2839
Assessment of the combined in‐plane and out‐of‐plane behavior of brick infill walls within reinforced concrete frames under seismic loading
Summary: Understanding the out‐of‐plane response of masonry infill walls and preventing their progressive collapse mechanisms is very important for earthquake‐prone countries to prevent loss of life and economic loss. In fact, having a realistic collapse mechanism assessment allows suitable prevention measures to be adopted. With this purpose in mind, two full‐scale one‐bay one‐story substructures of reinforced concrete frames (RCF) with infill walls were tested on a shake table. These 2 specimens were designed to represent the response of a typical RC Frame at the fifth floor of an 8‐story building, namely the out‐of‐plane failure of its infill wall under combined bidirectional seismic load. Both specimens were composed of a single‐leaf clay brick infill wall surrounded by the RC Frame. However, while the first specimen corresponds to an unreinforced masonry configuration, the second specimen includes horizontal bed joint reinforcement as a strengthening/retrofitting technique. The main novelty of this study is the application of a bidirectional and simultaneous dynamic loading to the specimen, such that in‐plane and out‐of‐plane effects are evaluated together. This work presents several interesting experimental results, with particular emphasis on the bearing capacity of the specimens against out‐of‐plane failure. As expected, the in‐plane capacity of the reinforced infill specimen is larger than that of the unreinforced infill specimen. Nevertheless, the out‐of‐plane bearing capacities of the two specimens are very similar, in contrast to their ductility capacity, which is significantly increased in the reinforced masonry specimen. The capacities of the two specimens for both in‐plane and out‐of‐plane directions, as predicted by formulations in the literature, are given. The differences found between these calculations and the results of the tests are discussed, and may possibly be explained by the parameters considered in the different formulations.
- 5 September 2018
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 47 (14) , 2821-2839
Assessment of the combined in‐plane and out‐of‐plane behavior of brick infill walls within reinforced concrete frames under seismic loading
Summary: Understanding the out‐of‐plane response of masonry infill walls and preventing their progressive collapse mechanisms is very important for earthquake‐prone countries to prevent loss of life and economic loss. In fact, having a realistic collapse mechanism assessment allows suitable prevention measures to be adopted. With this purpose in mind, two full‐scale one‐bay one‐story substructures of reinforced concrete frames (RCF) with infill walls were tested on a shake table. These 2 specimens were designed to represent the response of a typical RC Frame at the fifth floor of an 8‐story building, namely the out‐of‐plane failure of its infill wall under combined bidirectional seismic load. Both specimens were composed of a single‐leaf clay brick infill wall surrounded by the RC Frame. However, while the first specimen corresponds to an unreinforced masonry configuration, the second specimen includes horizontal bed joint reinforcement as a strengthening/retrofitting technique. The main novelty of this study is the application of a bidirectional and simultaneous dynamic loading to the specimen, such that in‐plane and out‐of‐plane effects are evaluated together. This work presents several interesting experimental results, with particular emphasis on the bearing capacity of the specimens against out‐of‐plane failure. As expected, the in‐plane capacity of the reinforced infill specimen is larger than that of the unreinforced infill specimen. Nevertheless, the out‐of‐plane bearing capacities of the two specimens are very similar, in contrast to their ductility capacity, which is significantly increased in the reinforced masonry specimen. The capacities of the two specimens for both in‐plane and out‐of‐plane directions, as predicted by formulations in the literature, are given. The differences found between these calculations and the results of the tests are discussed, and may possibly be explained by the parameters considered in the different formulations.