VOVladimir V. Ostrovskij

Vladimir V. Ostrovskij

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vladimir V. Ostrovskij has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Aspects of surgical treatment of a patient with multiple-level injuriy to the thoracic and lumbar spine (clinical case)

    by Vladimir Yu. Ostrovskij, Stanislav D. Shuvalov, Alexey Е. Shulga, Sergey P. Bazhanov, Vladimir S. Tolkachev

    This case report justifes the feasibility of a two-stage surgical management of a 38-year-old patient with a complicated unstable compression-comminuted ThXII and LIV fracture (AO Spine type A4). The patient sufered multiple-level spinal injuries after a fall from a height. Six days after an emergency LIII–LIV laminectomy, he underwent a two-stage procedure in a single session: transpedicular fxation of the ThXI–LI and LIII–LV with kyphosis correction, followed by thoracophrenolumbotomy, ThXII and LIV corpectomy, anterior decompression, and interbody fusion with cages and osteoinductive material. The postoperative period was uneventful. After 6 months, muscle strength in the lower extremities increased from 2 to 4 points (according to the Medical Research Council), the American Spinal Injury Association status improved from C to D, and pelvic organ function was restored. The Oswestry Disability Index decreased from 82 to 18%. Thus, the two-stage combined treatment in one surgical session is efective and safe. The intraoperative neuro-monitoring and modern implants minimizes the risk of neurological complications and ensures biomechanical stability.

  • A customized approach for accurate rotational positioning of the femoral component in total knee arthroplasty

    by R. A. Zubavlenko, V. V. Ostrovskij, S. V. Belova, D. A. Markov

    Introduction Rotational alignment of the femoral component is important for a good functional outcome and the long-term success of total knee arthroplasty (TKA). The objective was to evaluate the effectiveness of a customized approach for accurate rotational positioning of the femoral component in total knee arthroplasty. Material and methods Outcomes of TKA were comprehensively evaluated in 94 patients with Kellgren – Lawrence grade III–IV osteoarthritis. Femoral component rotation was determined in the first group ( n = 46) using visual-manual techniques based on the posterior condylar and surgical supracondylar lines. A goniometer was used in the second group ( n = 48) to determine the surgical supracondylar line along the anterior tangent line at the angle measured with computed tomography. Statistical analysis of the data was performed using IBM SPSS 20 Statistics and Statistica 13.3 software packages. Results Analysis of postoperative data on the angle between the surgical supracondylar and posterior condylar lines in the first group revealed a deviation from the normal values with a median of 3.45° (1.9°; 3.8°), indicating significant external rotation of the femoral component. Internal rotation of the femoral component of the implant was observed in two clinical cases reaching 3.5°, indicating mild to moderate malrotation. The anterior tangent line served as a landmark in the second group, and the mean arithmetic value of the angle between the surgical supracondylar and posterior condylar lines measured 0.9° (0.6°; 1.2°) postoperatively. The measurement suggested the significant line to be used as a promising landmark in primary TKA. Discussion Ji et al. explored the angle between the surgical supracondylar and anterior tangent lines and performed a comparative analysis of methods based on supracondylar, anterior tangent, and anterior patellar lines. The approach facilitated an objective assessment of the applicability for solving clinical problems and confirmed our analytical data. The authors emphasized the anterior patellar line and suggested its potential for correcting varus deformity of the knee joint. In our series, the knee alignment was not considered and the focus was on the anterior tangent line, which has not been reported in Russian studies. Conclusion The customized approach for accurate rotational positioning of the femoral component using the FAT line demonstrated its high efficacy in TKA. The approach facilitated accurate component positioning minimizing the risk of errors. The findings suggested that customized navigation techniques can be used in routine clinical practice.

  • Personalized technique for the rotation alignment of the knee implant femoral component

    by Roman A. Zubavlenko, Vladimir Yu. Ostrovskij, Oleg Yu. Voskresenskij

    Objective: the designing of the personalized technique for rotational alignment of the knee implant femoral component. Material and methods. This study is based on the findings of the retrospective analysis of 127 CT knee scans from patients who suffered I–III stages of knee osteoarthritis by N.S. Kosinskaya classification. The anatomical and surgical supracondylar and posterior condylar lines commonly used in preoperative planning for the alignment of knee implant femoral component were defined. A new more precise line designated as the front tangent was also described; this is not yet used in the national practice (patent for invention RU 2819654 С1б 2024). Results. The standard external rotation inclination (3º) is not universal for all patients because the angle between the surgical and posterior condylar lines varies in the range of 1.5º (0.6–4.3º) in stage III osteoarthritis. The analysis revealed statistically significant strong correlations between the angles formed by the anterior tangent and the surgical lines, as well as the anatomical supracondylar line (R=0.9724). These served as the basis for the designing of a preoperative planning technique that rests on the anterior tangent line. Conclusion. The designed personalized technique for rotational alignment of the knee implant femoral component features significant practical potential due to the close relationship of the anterior tangent line with the anatomical and surgical supracondylar lines determined by standard angular measurements.

  • Specifics of femoral component rotation in total knee arthroplasty: a review

    by Roman A. Zubavlenko, Vladimir V. Ostrovskij

    Optimal rotational alignment of the femoral component is critical in total knee arthroplasty. The measured resection technique, gap-balancing technique, and hybrid approach are available intraoperative methods for determining femoral rotation; however, each has distinct advantages and limitations. This review aimed to examine the potential of preoperative planning, assess the impact of femoral component malrotation and its acceptable limits on surgical outcomes, and determine the feasibility of using standard intraoperative methods for establishing femoral component rotation as a reference approach in total knee arthroplasty. The systematic review was planned and conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines. The review reports study characteristics, the number of patients dissatisfied with surgical outcomes, and the specific features of preoperative, intraoperative, and postoperative methods used to determine femoral component rotation in total knee arthroplasty. Initially, 354 articles meeting the main search criteria were identified. Overall, outcomes from 2132 total knee arthroplasties reported in the retrieved publications were analyzed. A total of 149 patients were dissatisfied with surgical outcomes because of anterior knee pain. As modern imaging technologies continue to advance rapidly, the use of more contemporary preoperative assessment methods is becoming increasingly relevant to improve clinical outcomes. Although visual and manual techniques may appear effective, they may be associated with a risk of femoral component malrotation exceeding 3°, which to some extent limits their use in clinical practice. The use of costly imaging modalities, such as computed tomography or magnetic resonance imaging, is not a standard procedure for postoperative screening assessment of implant position.

  • Open Access

    The role of expandable cages for vertebral body replacement in surgical treatment of patients with thoracic and lumbar spine injuries: a systematic review

    by S. D. Shuvalov, A. E. Shulga, S. P. Bazhanov, V. V. Ostrovskij, V. S. Tolkachev

    Роль телозамещающих имплантатов расширяемого типа в хирургическом лечении пациентов с повреждениями грудных и поясничных позвонков: систематический обзор

  • Long-term results of surgical treatment in patients with uncomplicated trauma to the thoracic and lumbar spine segments (systematic review)

    by Vladimir S. Tolkachev, Alexey Е. Shulga, Sergey P. Bazhanov, Stanislav D. Shuvalov, Vladimir V. Ostrovskij

    Objective: to conduct a systematic analysis of long-term outcomes of surgical treatment in patients with uncomplicated thoracic and lumbar spine trauma. Review methodology. The studies to analyze were retrieved from PubMed, Scopus, and Web of Science using a combination of MeSH terms and keywords: "spinal fracture", "surgical treatment", "support spondylosis", "visual analog scale", "health-related quality of life", "Oswestry Disability Index". The search was limited to the full text original studies. The search retrieved 1,245 articles, leaving 6 articles published between 2018 and 2024 after checking the eligibility criteria for inclusion. We calculated the changes in visual analog scale (AVAS) and Oswestry Disability Index (AODI) scores, Cobb loss of primary correction (COBB0), and complication rates (percent). Conclusion. AVAS ranged from 1.88 to 7.8 scores, AODI ranged from 33.05 to 51.85 percent, ACOBB0 ranged from 0.9 to 4.7 degrees, and complication rates ranged from 5 to 70 percent. Thus, the anterior support spondylosis leads to clinically significant reduction of pain syndrome and restoration of functional activity in patients who suffered uncomplicated fractures of thoracic and lumbar vertebrae; however, it should be noted that the data are limited by small samples and heterogeneity of study protocols, which may require further randomized multicenter studies.

  • Open Access

    Specifics of rotational planning and intraoperative alignment of the femoral component in the knee implant with navigation devices (systematic review)

    by R. A. Zubavlenko, D. A. Markov, V. V. Ostrovskij

    Introduction The optimal rotational alignment of the femoral component in a knee implant with navigation devices is important for total knee arthroplasty. Measured resection and gap technique are available intraoperative methods to determine the rotation of femur with navigation devices, but each of these methods has its advantages and disadvantages. These aspects have contributed to the development and clinical validation of navigation tools for large joint arthroplasty.The objective of this study was to evaluate the efficacy of determining the rotational alignment of the femoral component in a knee implant with mechanical and robotic navigation devices as a basis for processing intraoperative decision making by surgeons.Material and methods The planning, execution and reporting of this systematic review were conducted in accordance with the established Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. Initially we identified 366 studies that corresponded to the main focus of this research, and 158 studies were selected for analysis after the duplicates had been excluded. Ultimately, only 11 studies fully met the selection criteria. The evaluation included the article data, the type of mechanical or robotic navigation device, the number of cases, the complication rate, and the specifics of the preoperative, intraoperative, and postoperative methods used for determining the rotation of the femoral component in a knee implant in the cohorts reviewed. A total of 1,198 total knee arthroplasties reported in those studies were analyzed.Results and discussion It should be noted that in most of the scientific papers on the postoperative complications of surgeries that involved various navigation devices, the information about them was incomplete or the patients with complications were excluded from the study. In general, the incidence of complications averaged 2 %.Conclusions When the navigation devices are used, the preoperative planning of the femoral component alignment frequently remains unperformed, and techniques and reference points used in surgeries are the same as in the traditional technique. The postoperative monitoring of rotational alignment of the knee implant is performed exclusively when complications are detected.


  • Deformational and strength properties of full-scale models of transpedicular fixation and supportive spinal fusion in thoracic and lumbar regions

    by Alexey E. Shulga, Yuliya Yu. Rozhkova, Vladimir Yu. Ulyanov, Stanislav D. Shuvalov, Vladimir S. Tolkachev, Sergey P. Bazhanov, Vladimir V. Ostrovskij

    Objective: the evaluation of stability for various options of thoracic and lumbar spine fixation in static load. Material and methods. We used the anatomical preparations of the thoracic and lumbar porcine spines to model comminuted vertebra fractures A4 (AOSpine, 2013) in the middle of the anatomical block. The models were later used to install 4 most common types of metal fixation, and to study their deformation-strength properties in controlled axial compression, including maximum load and stress. Results. The increasing differences in the median values of maximum loads (H)and stresses (MPa) were found at controlled axial compression in models of 4-screw(2980 H, 7.18 MPa) and 8-screw (4240 H, 9.78 MPa) transpedicular fixation, 4-screw (6460H, 15.27 MPa) and 8-screw (10120 H, 103.21 MPa) transpedicular fixation and supporting spinal fusion, leading to axial deformation and/or destruction of metal structures, as well as destruction of the vertebrae bone structures. Conclusion. The model of 8-screw transpedicular fixation and supporting spinal fusion has the greatest stability in controlled axial compression; all its nodes in the metal structure remain stable and the bone structures of the vertebrae are preserved.

  • The use of implants made from different materials in lumbar spinal fusion surgery (review)

    by Stanislav D. Shuvalov, Vladimir S. Tolkachev, Sergey P. Bazhanov, Alexey E. Shulga, Vladimir V. Ostrovskij, Vladimir Yu. Ulyanov

    Objective: perform a comparative analysis of the osteointegration of intervertebral implants made of polyetheretherketone (PEEK), titanium (Ti) alloy and porous Ti after posterior lumbar interbody fusion. Methodology for writing a review. The interbody fusion, lumbar spine, cage, orthopedic implants, osseointegration, porous titanium keywords search for 1953-2023 studies in English and Russian involved PubMed and eLibrary databases. Results. Titanium and titanium-coated PEEK implants for lumbar interbody fusion feature similar subsidence rates, but titanium implants have a higher fusion rate thanthose of PEEK implants. Conclusion. Ti-cages and Ti-coated PEEK implants used for interbody spinal fusion in the lumbar spine show similar subsidence rates but higher fusion rates compared to PEEK cages. Randomized controlled trials are needed to more accurately assess the impact of framework materials and potential factors that may influence surgical outcomes.


  • Open Access

    Analysis of knee arthroplasty revision causes

    by M. V. Girkalo, I. N. Shchanitsyn, V. V. Ostrovskij

    Introduction Existing discrepancies in knee arthroplasty registries regarding the definition of indications for revision TKA lead to confusion related to the identification of the leading pathology. Many works indicate not only one but several reasons for revision which makes comparison difficult. Therefore, the issue of categorizing indications for revision TKA is a weak point of the available registries and of any large retrospective series.Purpose To systematize the etiology of pathological conditions leading to revision knee arthroplasty.Materials and methods The study included 361 revision knee arthroplasties. A comparative analysis of the etiology of complications of primary arthroplasty was carried out with data from national arthroplasty registries and clinical studies.Results The main indications for revision knee arthroplasty were infection in 48.2 % of cases (174/361), aseptic implant instability (osteolysis) in 38.2 % (138/361), and instability of the ligamentous apparatus in 4.2 % (15/361). In 98 cases (27.1 %), only one type of complication was identified, and in 263 (85.2 %) more than one. Infection prevailed among early complications (126/234, 54 %) and aseptic loosening (osteolysis) (69/127, 54 %) predominated among late complications.Discussion In our opinion, the indications for revision arthroplasty can be divided into three main etiological groups: periprosthetic infection (group I); conditions associated with a response to polyethylene wear products (osteolysis) (group 2); and biomechanical disorders, which include spatial malposition, incorrect implant sizes and all types of instability (group 3).Conclusion Our systematization of revision arthroplasty causes can help in further research and will be useful in creating a national registry of arthroplasties in Russia.