FQFlavio Quizhpi

Flavio Quizhpi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Flavio Quizhpi has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Proposals for the creation of energy communities: Regulatory support

    by Hector Montaño, José David Muñoz, Flavio Quizhpi

    This work aims to propose a regulatory framework for the creation of energy communities in Ecuador by referencing successful international experiences and adapting them to the national context. Through a detailed analysis of the current legal framework regarding distributed generation and renewable energy, the study identifies existing opportunities and limitations for implementing such communities. The research applied a qualitative and documentary methodology, including a comprehensive literature review and expert interviews with academics, officials from public and private energy generation and transmission companies. Additionally, successful energy community models from countries such as Spain, Germany, and the USA were examined. The major findings include the lack of specific regulations in Ecuador, which hinders the development of decentralized energy systems. Based on this, a normative proposal was developed to promote the use of renewable energy and citizen participation in energy production and management. This study contributes to Ecuador’s energy transition by encouraging decentralization and sustainability, and it offers concrete strategies for the technical, economic, and social feasibility of energy communities. The findings aim to support policy-making and investment in renewable energy and distributed generation projects.

  • Grid Connected Inverter with Active Power Filter Capabilities for Two-phase Systems

    by Julio Viola, Marco Fajardo, Jose Manuel Aller, Jose Restrepo, Flavio Quizhpi

    The integrated operation of a grid connected inverter acting at the same time as shunt active power filter is presented. The paper shows that the same hardware can be used for active power injection from PV arrays to the mains, reactive power compensation with current harmonic mitigation, and active power balancing in two-phase residential systems. A three-leg two-level voltage source inverter is used for this aim and current loops based on DC link voltage control are developed.


  • Application of Disruptive Tests for the Determination of BIL through Spinterometric Spheres in the High Voltage Laboratory of the Salesian Polytechnic University

    by D. Criollo-Tacuri, S. Tapia-Cardenas, F. Quizhpi-Palomeque

    BIL is the basic level of insulation for lightning impulse test or NBI that determines the dielectric strength of a device which is expressed as a function of the peak value of a standard pulse. The research carried out contributes with values in disruptive tests in medium voltage devices through spinterometric spheres constructed, in their electronic stage, by the authors. which allow lightning-type discharge. This document presents the tests carried out at different voltage levels and determines the percentage of failure probability of the device. In this proposed approach, each of the devices will have its atmospheric correction factor for the positive and negative impulse tests, obtaining the parameters and adequate voltage levels for the applied tests. In this way the functioning of the proposed electronic circuit for the spheres was validated, the respective analysis of the tests was carried out according to the IEEE Std 4 applied for this type of tests.


  • Classification of partial discharge in pin type insulators using fingerprints and neural networks

    by M. Quizhpi-Cuesta, F. Gomez-Juca, W. Orozco-Tupacyupanqui, F. Quizhpi-Palomeque

    The classification of partial discharge (PD) or partial breakdown (PB) is an important issue that helps to identify the cause of this electrical phenomenon in pin type insulators. In this work, a PD classification method based on neural networks (NN) is proposed. This sorting technique consists of three parts. First, the detection and measurement of partial discharge are achieved by using a digital finite impulse response (FIR) filter, whose main objective is to obtain electrical charges with significant characteristics of the PB. The second part of the process deals with the classification of partial discharge. A statistical analysis is implemented to obtain PD patterns or fingerprints which are classified by a neural network. Finally, the third part of the proposed method focuses on interpreting the information obtained from the NN and determining the PD current in the pin isolator. The results show that this proposed technique of analysis and detection of partial discharge in pin type isolators is successful in optimizing the time of analysis and classification of PB.


  • Measurement of internal partial discharges in dielectric oils by applying the electrical method

    by Jaime A. Torres-Arias, Cristhian M. Quezada-Viñanzaca, Diego P. Chacón-Troya, Flavio Quizhpi-Palomeque

    This document details of the conventional electric method for measuring partial discharges (DP) based on the norm IEC 60156, various test were performed on dielectric oils which had different qualities, the test results were processed through MATLAB's signal processing filters in conjunction with fast Fourier transform (FFT) in order to determine the type of partial discharge based on the quality of the dielectric oil and it's contamination level.


  • Calculation of the earth resistance of the union of two and three rods by modified Schwarz equations and field tests

    by S. Freddy M. Sinchi, P. Flavio A. Quizhpi, C. Hernán P. Guillén

    This report discloses the modification of the Schwarz equations presented in the IEEE 80-2013 standard, in order to calculate the ground resistance of two and three rods connected in line, and three rods connected in triangle. The implementation of these designs is carried out in several soils with different resistivity values, to proceed to measure the resistance of grounding and to check with the theoretical calculation.


  • Simulation of harmonics produced by electroliners in the electrical network of Cuenca City

    by Cristian Enriquez, Diego Chacon-Troya, Hector Romero, Flavio Quizhpi

    This article presents the simulation and harmonic analysis of a charging station model developed in “Modeling and protection of electric vehicle charging station”, which was adapted with the electrical parameters of the distribution system of Cuenca city, with The purpose of quantifying the amount of harmonics that this type of stations can produce in the network. The simulation resulted, that the fifth harmonic located at 300 Hz is the most critical in both the voltage and the current. The harmonics produced in the voltage are 15, 74% that are above the limits established in the IEEE 519-2014 standard and the Ecuadorian regulation No. CONELEC-004/01, the harmonics produced in the current are of the order of 1.54% that is within the parameters of the IEEE 519-2014 standard. The results of this research can be used to mitigate the impact and can be used by designers and builders of charging stations and for energy distribution companies.


  • Implicit PV cell parameters estimation used in approximated closed-form model for inverter power control

    by Jose Aller, Julio Viola, Flavio Quizhpi, Jose Restrepo, Antonio Ginart, Andres Salazar

    This paper evaluates the use of a Photo Voltaic (PV) parameter estimation method based on implicit optimization algorithms and its use in power controller strategies by explicit model representation obtained with First and Second Order Approximation Models (FOAM, SOAM). An explicit function linking voltage, current and power of PV) cells is presented using the parameters obtained during the implicit estimation. The proposed method gives direct analytical solutions, resulting from a truncated Taylor series for the single diode PV-model. The analytical equations are easier to put into practical use and give solutions with an equivalent precision similar to the numerical method (Newton-Raphson Method) for the PV's cell voltage produced under particular conditions of temperature and solar radiance. The main benefit of this set of equations, useful also for optimal voltage estimation, is that offer an accurate and simple determination of the voltage profile using the manufacturer's data-sheet and PV plant's location for an specific design. The verification of the proposed method uses information from the manufacturer's datasheets of 12 different PV cells. The comparison of the results, for the analytical expressions versus the Newton-Raphson solution, validates the proposed method.


  • Back-to-Back Active Power Filter for Current Balancing in Two-Phase Systems

    by Julio Viola, Marco Fajardo, Jose Manuel Aller, Flavio Quizhpi, Jose Restrepo, Antonio Ginart

    The use of a second phase in household electric wiring is a requirement for feeding heavy loads in those countries using 100 ~ 127 Vrms as the standard voltage. One problem of this wiring is the unbalance between phase currents since single-and two-phase loads coexist. A back-to-back topology is proposed for an active power filter to add it the ability of active power compensation. The presented topology uses the same number of hardware components of others proposed topologies that just are able of reactive power compensation. The system is tested implementing a predictive direct current control when is connected to two different two-phase systems: those obtained by taking two phases of a three-phase system (120° between phases) and for two phases obtained from a split-phase transformer secondary (180° between phases).