Yantao Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yantao Liu has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
- Long Wei
Chinese Academy of Sciences
10 shared publications - Yingjie Wang
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
7 shared publications Zhiming Zhang
7 shared publicationsDaowu Li
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences 1 , Beijing 100049, China
5 shared publicationsLei Shuai
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences 1 , Beijing 100049, China
5 shared publications- Shuangquan Liu
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
5 shared publications
Latest Publications
- 29 September 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1044
Coded aperture and Compton imaging capability of spherical detector system design based on GAGG scintillators: A Monte Carlo study
- 29 September 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1044
Coded aperture and Compton imaging capability of spherical detector system design based on GAGG scintillators: A Monte Carlo study
- Open Access
- 1 August 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (8) , 085317
High-sensitivity stereo coded aperture gamma camera for three-dimensional localization of radioactive hotspots
This work presents a novel stereo coded aperture gamma camera based on four detection modules placed within four quadrants. Each module includes 48 × 48 strips of Bi4Ge3O12 scintillators, 24 × 24 pieces of silicon photomultipliers (SiPMs), and a set of data acquisition circuits. All signals from the SiPMs are individually extracted and finally simplified into 144 outputs to calculate the positions and energies of gamma-rays. Two masks of modified uniformly redundant arrays are fixed in the front of the top-right and bottom-left modules and two anti-masks are fixed in the top-left and bottom-right modules to achieve simultaneous imaging without dual measure. Once the projections of radioactive sources are determined, their source-to-detector distances can be estimated by our new multocular ranging algorithm. A series of lab and field experiments, including flood histogram and energy spectrum testing, field-of-view and angular resolution testing, real-time imaging, long-distance imaging, and ranging ability testing, with different radioactive sources, such as 137Cs, 22Na, 241Am, 60Co, 133Ba, and 75Se, have been completed to evaluate the comprehensive ability of the stereo gamma camera. The results show that the stereo gamma camera has a strong ability for the three-dimensional localization of radioactive sources over long distances with a high image sensitivity. So far, the stereo gamma camera has been successfully used in practical nuclear security and safety tasks although the angular resolution and the ranging algorithm robustness should be more optimized in the future.
- 1 August 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (8) , 085317
Open AccessHigh-sensitivity stereo coded aperture gamma camera for three-dimensional localization of radioactive hotspots
This work presents a novel stereo coded aperture gamma camera based on four detection modules placed within four quadrants. Each module includes 48 × 48 strips of Bi4Ge3O12 scintillators, 24 × 24 pieces of silicon photomultipliers (SiPMs), and a set of data acquisition circuits. All signals from the SiPMs are individually extracted and finally simplified into 144 outputs to calculate the positions and energies of gamma-rays. Two masks of modified uniformly redundant arrays are fixed in the front of the top-right and bottom-left modules and two anti-masks are fixed in the top-left and bottom-right modules to achieve simultaneous imaging without dual measure. Once the projections of radioactive sources are determined, their source-to-detector distances can be estimated by our new multocular ranging algorithm. A series of lab and field experiments, including flood histogram and energy spectrum testing, field-of-view and angular resolution testing, real-time imaging, long-distance imaging, and ranging ability testing, with different radioactive sources, such as 137Cs, 22Na, 241Am, 60Co, 133Ba, and 75Se, have been completed to evaluate the comprehensive ability of the stereo gamma camera. The results show that the stereo gamma camera has a strong ability for the three-dimensional localization of radioactive sources over long distances with a high image sensitivity. So far, the stereo gamma camera has been successfully used in practical nuclear security and safety tasks although the angular resolution and the ranging algorithm robustness should be more optimized in the future.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (8) , 1931-1938
Far-Field 3-D Localization of Radioactive Hotspots via Four-Eyes Stereo Gamma Camera
In the fields of radiation environment monitoring and unknown radioactive materials search, locating the far-field gamma-ray sources with high accurate coordinates is an important and necessary capability for a gamma imager. However, traditional coded gamma-ray imaging systems only provide 2-D radiation images without distance information. In this work, a four-eyes stereo gamma camera is proposed, which consists of four independent coded aperture detectors with an adjacent spacing of 286 mm. Each detector is comprised of pixelated scintillators with a pixel array of 44 $\times44$ , forming a global detection area of 140 $\times140$ mm 2 . The ranging capability is related to the resolution and the adjacent spacing of the detectors. With the setup of the above device, the traditional binocular-based ranging method has a short measurement range and a large measurement deviation. Here, a min-area distance measurement algorithm based on a four-eyes stereo gamma camera is proposed, combined with “manual” fine sampling and Gaussian fitting method to successfully achieve the high-precision localization of the far-field source. The simulation results show that compared with the traditional binocular-based ranging method, the min-area method based on a four-eyes stereo camera lengthens the range from 20 m to more than 50 m and improves the ranging accuracy within 20 m by more than six times. The accuracy of 20 and 50 m is less than 1.4 m (7.13%) and 10.5 m (21%), respectively. The reliability of the simulation results has been verified by experiments. Furthermore, the ranging capability of this algorithm for multipoint sources in the far field has been verified.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (8) , 1931-1938
Far-Field 3-D Localization of Radioactive Hotspots via Four-Eyes Stereo Gamma Camera
In the fields of radiation environment monitoring and unknown radioactive materials search, locating the far-field gamma-ray sources with high accurate coordinates is an important and necessary capability for a gamma imager. However, traditional coded gamma-ray imaging systems only provide 2-D radiation images without distance information. In this work, a four-eyes stereo gamma camera is proposed, which consists of four independent coded aperture detectors with an adjacent spacing of 286 mm. Each detector is comprised of pixelated scintillators with a pixel array of 44 $\times44$ , forming a global detection area of 140 $\times140$ mm 2 . The ranging capability is related to the resolution and the adjacent spacing of the detectors. With the setup of the above device, the traditional binocular-based ranging method has a short measurement range and a large measurement deviation. Here, a min-area distance measurement algorithm based on a four-eyes stereo gamma camera is proposed, combined with “manual” fine sampling and Gaussian fitting method to successfully achieve the high-precision localization of the far-field source. The simulation results show that compared with the traditional binocular-based ranging method, the min-area method based on a four-eyes stereo camera lengthens the range from 20 m to more than 50 m and improves the ranging accuracy within 20 m by more than six times. The accuracy of 20 and 50 m is less than 1.4 m (7.13%) and 10.5 m (21%), respectively. The reliability of the simulation results has been verified by experiments. Furthermore, the ranging capability of this algorithm for multipoint sources in the far field has been verified.
- Open Access
- 1 June 2021
- Published by Elsevier in Integrative Medicine Research
- Vol. 10 (2) , 100665
The efficacy and safety of traditional Chinese medicines, modified Radix Fici Simplicissimae, combined with Western medicines amongst patients infected with the 2019 novel coronavirus (SARS-CoV-2) in tropical tourist area, China
- 1 June 2021
- Published by Elsevier in Integrative Medicine Research
- Vol. 10 (2) , 100665
Open AccessThe efficacy and safety of traditional Chinese medicines, modified Radix Fici Simplicissimae, combined with Western medicines amongst patients infected with the 2019 novel coronavirus (SARS-CoV-2) in tropical tourist area, China
- Open Access
- 1 May 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (5) , 053304
Novel compact high-speed passive gamma-ray assay equipment for uranium enrichment measurement of fuel rods
Uranium enrichment measurement is an essential quality inspection for fuel rods before delivery to users. Generally, compared with active neutron assay (ANA) equipment, passive gamma-ray assay (PGA) equipment is more economical and safer. However, the current PGA equipment based on photomultipliers is too slow (1 m/min) to meet the growing needs in China. Recently, we have developed a set of compact high-speed PGA equipment including four detection modules (128 units in total), a 128-channel data acquisition system (DAS), a power supply, special software, and an automatic loading and unloading mechanism. The detection unit is based on silicon photomultipliers in virtue of its compact size and good performance. The DAS processes signals of all units in parallel into a sequence of data packets carrying the energy information and the corresponding unit ID. The software integrates the data packets into a fluctuating count curve in a time-delay superposition method and identifies possible abnormal pellets. After calibrations, our equipment can locate abnormal pellets accurately at a speed of 6 m/min. In addition, it can directly measure the enrichment of fresh pellets not in secular equilibrium without waiting for two months. So far, the equipment has been successfully run for one year on the assembly line of China North Nuclear Fuel Co. and shows good potential to replace the traditional ANA equipment.
- 1 May 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (5) , 053304
Open AccessNovel compact high-speed passive gamma-ray assay equipment for uranium enrichment measurement of fuel rods
Uranium enrichment measurement is an essential quality inspection for fuel rods before delivery to users. Generally, compared with active neutron assay (ANA) equipment, passive gamma-ray assay (PGA) equipment is more economical and safer. However, the current PGA equipment based on photomultipliers is too slow (1 m/min) to meet the growing needs in China. Recently, we have developed a set of compact high-speed PGA equipment including four detection modules (128 units in total), a 128-channel data acquisition system (DAS), a power supply, special software, and an automatic loading and unloading mechanism. The detection unit is based on silicon photomultipliers in virtue of its compact size and good performance. The DAS processes signals of all units in parallel into a sequence of data packets carrying the energy information and the corresponding unit ID. The software integrates the data packets into a fluctuating count curve in a time-delay superposition method and identifies possible abnormal pellets. After calibrations, our equipment can locate abnormal pellets accurately at a speed of 6 m/min. In addition, it can directly measure the enrichment of fresh pellets not in secular equilibrium without waiting for two months. So far, the equipment has been successfully run for one year on the assembly line of China North Nuclear Fuel Co. and shows good potential to replace the traditional ANA equipment.
- 1 November 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 113308
An instrument for measuring scintillators efficiently based on silicon photomultipliers
An instrument used for measuring multiple scintillators’ light output and energy resolution was developed. The instrument consisted of a light sensor array which was composed of 64 discrete SiPMs (Silicon Photomultipliers), a corresponding individual channel readout electronics system, and a data processing algorithm. A Teflon grid and a large interval between adjacent SiPMs were employed to eliminate the optical cross talk among scintillators. The scintillators’ light output was obtained by comparing with a reference sample with known light output. Given the SiPM temperature dependency and the difference among each SiPM, a temperature offset correction algorithm and a non-uniformity correction algorithm were added to the instrument. A positioning algorithm, based on nine points, was designed to evaluate the performance of a scintillator array. Tests were performed to evaluate the instrument’s performance. The uniformity of 64 channels for light output measurement was better than 98%, the stability was better than 98% when temperature varied from 15 °C to 40 °C, and the nonlinearity under 511 keV was better than 2%. This instrument was capable of selecting scintillators and evaluating the packaging technology of scintillator arrays with high efficiency and accuracy.
- 1 November 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 113308
An instrument for measuring scintillators efficiently based on silicon photomultipliers
An instrument used for measuring multiple scintillators’ light output and energy resolution was developed. The instrument consisted of a light sensor array which was composed of 64 discrete SiPMs (Silicon Photomultipliers), a corresponding individual channel readout electronics system, and a data processing algorithm. A Teflon grid and a large interval between adjacent SiPMs were employed to eliminate the optical cross talk among scintillators. The scintillators’ light output was obtained by comparing with a reference sample with known light output. Given the SiPM temperature dependency and the difference among each SiPM, a temperature offset correction algorithm and a non-uniformity correction algorithm were added to the instrument. A positioning algorithm, based on nine points, was designed to evaluate the performance of a scintillator array. Tests were performed to evaluate the instrument’s performance. The uniformity of 64 channels for light output measurement was better than 98%, the stability was better than 98% when temperature varied from 15 °C to 40 °C, and the nonlinearity under 511 keV was better than 2%. This instrument was capable of selecting scintillators and evaluating the packaging technology of scintillator arrays with high efficiency and accuracy.