Sergio Lugo
Research Subjects
Sergio Lugo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
O. García-Valladares
2 shared publicationsR. Best
2 shared publicationsElisa Viñas
1 shared publicationF. Hernández
1 shared publicationJ. Hernández
1 shared publicationL.I. Morales
1 shared publication
Latest Publications
- 1 September 2019
- Published by Elsevier in Solar Energy
- Vol. 189, 45-56
Numerical simulation and experimental validation of an outdoor-swimming-pool solar heating system in warm climates
- 1 September 2019
- Published by Elsevier in Solar Energy
- Vol. 189, 45-56
Numerical simulation and experimental validation of an outdoor-swimming-pool solar heating system in warm climates
- 1 August 2019
- Published by Elsevier in Renewable Energy
- Vol. 139, 1120-1132
Numerical simulation and experimental validation of an evacuated solar collector heating system with gas boiler backup for industrial process heating in warm climates
- 1 August 2019
- Published by Elsevier in Renewable Energy
- Vol. 139, 1120-1132
Numerical simulation and experimental validation of an evacuated solar collector heating system with gas boiler backup for industrial process heating in warm climates
- 1 January 2018
- Published by Cal-Tek Srl
Modelling of a solar air conditioning pilot plant
"The present work repots the modelling of a solar air conditioning pilot plant to be installed in the Centro de Tecnología Avanzada (CIATEQ) in the city of Queretaro, México. The modelling was carried out by using the software Transient System Simulation Tool-16 (TRNSYS- 16). The pilot plant mainly consists of an absorption cooling system, a solar collector’s field, a hot water storage tank, a cooling tower and an air handler. The office of the CIATEQ were first modelling without an air conditioning unit and then with the proposed solar air conditioning pilot plant. The results showed that without air conditioning, temperatures higher than 28 ºC can be reached between the 12:00 and the 19:00 hours during spring and summer, while with the proposed pilot plant temperatures not higher than 25 ºC can be obtained during the whole year during the working hours."
- 1 January 2018
- Published by Cal-Tek Srl
Modelling of a solar air conditioning pilot plant
"The present work repots the modelling of a solar air conditioning pilot plant to be installed in the Centro de Tecnología Avanzada (CIATEQ) in the city of Queretaro, México. The modelling was carried out by using the software Transient System Simulation Tool-16 (TRNSYS- 16). The pilot plant mainly consists of an absorption cooling system, a solar collector’s field, a hot water storage tank, a cooling tower and an air handler. The office of the CIATEQ were first modelling without an air conditioning unit and then with the proposed solar air conditioning pilot plant. The results showed that without air conditioning, temperatures higher than 28 ºC can be reached between the 12:00 and the 19:00 hours during spring and summer, while with the proposed pilot plant temperatures not higher than 25 ºC can be obtained during the whole year during the working hours."
- 1 March 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 97, 28-38
Simulation of solar air conditioning systems in coastal zones of Mexico
- 1 March 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 97, 28-38
Simulation of solar air conditioning systems in coastal zones of Mexico
- 1 January 2016
- Published by International Solar Energy Society (ISES)
- p. 1-8
Numerical Simulation and Experimental Validation of a Solar Cooling System in Mexico
- 1 January 2016
- Published by International Solar Energy Society (ISES)
- p. 1-8
Numerical Simulation and Experimental Validation of a Solar Cooling System in Mexico