AWArtur Weiser

Artur Weiser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Artur Weiser has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automatic Calibration of a Device for Blood Pressure Waveform Measurement

    by Rafał Siemasz, Krzysztof Tomczuk, Ziemowit Malecha, Piotr Andrzej Felisiak, Artur Weiser

    This article presents a prototype of a new, non-invasive, cuffless, self-calibrating blood pressure measuring device equipped with a pneumatic pressure sensor. The developed sensor has a double function: it measures the waveform of blood pressure and calibrates the device. The device was used to conduct proof-of-concept measurements on 10 volunteers. The main novelty of the device is the pneumatic pressure sensor, which works on the principle of a pneumatic nozzle flapper amplifier with negative feedback. The developed device does not require a cuff and can be used on arteries where cuff placement would be impossible (e.g., on the carotid artery). The obtained results showed that the systolic and diastolic pressure measurement errors of the proposed device did not exceed ±6.6% and ±8.1%, respectively.


  • Open Access

    Endoscopic third ventriculostomy before surgery of third ventricle and posterior fossa tumours decreases the risk of secondary hydrocephalus and early postoperative complications

    by Pawel Tabakow, Artur Weiser, Malgorzata Burzynska, Przemyslaw Blauciak

    Endoscopic third ventriculostomy (ETV) is an effective treatment for obstructive hydrocephalus (HCP) at the level of third or fourth ventricle. To date, there is no consensus regarding its role as intervention preceding the operation of tumour removal. The aim of this prospective open-label controlled study is to assess if ETV prevents secondary HCP after tumour removal and if ETV influences the early results of tumour surgery. The study was performed on 68 patients operated for tumours of the third ventricle and posterior fossa. In 30 patients, ETV was performed several days before tumour removal, while in 38 patients, the tumour was removed during a one-stage procedure without ETV. Patients who did not receive ETV before the tumour removal procedure had a higher probability of developing postoperative HCP (n = 12, p = 0.03). They also demonstrated a substantially higher rate of early postoperative complications (n = 20, p = 0.002) and a lower Karnofsky score (p = 0.004) than patients in whom ETV was performed before tumour removal. The performance of external ventricular drainage in the non-ETV group did not prevent secondary HCP (p = 0.68). Postoperative cerebellar swelling (p = 0.01), haematoma (p = 0.04), cerebrospinal fluid leak (p = 0.04) and neuroinfection (p = 0.04) were the main risk factors of persistent HCP. Performance of ETV before tumour removal is not only beneficial for control of acute HCP but also prevents the occurrence of secondary postoperative HCP and may also minimize early postoperative complications.


  • Open Access

    Deep brain stimulation in obsessive-compulsive disorder – case report of two patients

    by Jan Beszłej, Damian Siwicki, Karolina Fila-Witecka, Tomasz Wieczorek, Patryk Piotrowski, Artur Weiser, Paweł Tabakow, Joanna Rymaszewska

    Zaburzenie obsesyjno-kompulsyjne (Obsessive-Compulsive Disorder - OCD) występuje u około 2-3% populacji. W związku przewlekłym przebiegiem i dużym procentem oporności na standardowe leczenie poszukuje się alternatywnego postępowania klinicznego bazującego na osiągnięciach neuroscience. Głęboka stymulacja mózgu (DBS - Deep Brain Stimulation) jest nowoczesną i dynamicznie rozwijającą się metodą, stwarzającą szanse na pomoc pacjentom opornym na dotychczasowe leczenie oparte na farmakoterapii i psychoterapii. W niniejszym opracowaniu przedstawiamy dwa przypadki pacjentów z rozpoznaniem opornego na leczenie OCD, u których zastosowano terapię DBS z jednoczesną farmakoterapią i psychoterapią kognitywno- poznawczą (CBT). U obojga pacjentów przeprowadzono zabieg neurochirurgiczny z implantacją elektrod do przedniej odnogi torebki wewnętrznej (ALIC) oraz jądra półleżącego (NAc). Przed i po rozpoczęciu stymulacji prowadzono regularną ewaluację kliniczną w oparciu o badanie psychiatryczne oraz pomiary psychometryczne (Y-BOCS, HAMA, HDRS, GAF, SOFAS). W trakcie okresu obserwacji wykonano ponadto zaślepioną próbę wyłączenia stymulacji. W okresie 6 miesięcznej obserwacji uzyskano znaczną redukcję w zakresie objawów obsesyjno-kompulsyjnych, depresyjnych, lękowych oraz poprawiło się funkcjonowanie pacjentów. Tolerancja terapii DBS była bardzo dobra i nie stwierdzono istotnych objawów niepożądanych. Uzyskane wyniki dają podstawy do wdrażania tej metody u innych, opornych na dotychczasowe leczenie pacjentów z OCD.


  • Open Access

    Deep brain stimulation: new possibilities for the treatment of mental disorders

    by Jan Beszłej, Tomasz Wieczorek, Agnieszka Kobyłko, Patryk Piotrowski, Damian Siwicki, Artur Weiser, Karolina Fila-Witecka, Joanna Rymaszewska, Paweł Tabakow

    Głęboka stymulacja mózgu (ang. Deep Brain Stimulation, DBS) to metoda leczenia, która jest obecnie obiektem coraz większej uwagi ze strony psychiatrów. Udowodniono, że jest skuteczna i bezpieczna w leczeniu zaburzeń neurologicznych, przede wszystkim choroby Parkinsona (PD), dystonii i drżenia samoistnego. DBS bardzo często pozwala na skuteczne leczenie w przypadkach opornych na wszystkie inne metody terapii. Obecnie oporne na leczenie zaburzenie obsesyjno-kompulsyjne (OCD) pozostaje głównym potwierdzonym zasadami EBM wskazaniem psychiatrycznym dla DBS. Wiele badań koncentruje się na ocenie skuteczności i bezpieczeństwa tej metody w innych zaburzeniach psychicznych, w tym w zaburzeniach depresyjnych, chorobie Alzheimera, jadłowstręcie psychicznym, zespole Tourette'a, uzależnieniu od substancji psychoaktywnych lub zachowaniach agresywnych.W ostatnich latach opisywano również pojedyncze przypadki skutecznego leczenia zaburzenia dwubiegunowego, schizofrenii i zespołu stresu pourazowego. W niniejszym opracowaniu przedstawiono aktualny stan wiedzy na temat przydatności DBS w psychiatrii w oparciu o dostępne przeglądy systematyczne, badania kliniczne i studia przypadków jak również o dane neurofizjologiczne i neuroobrazowe.


  • Open Access

    Navigated neuroendoscopy combined with intraoperative magnetic resonance cysternography for treatment of arachnoid cysts

    by Pawel Tabakow, Artur Weiser, Krzysztof Chmielak, Przemyslaw Blauciak, Joanna Bladowska, Marcin Czyz

    Endoscopic cystocysternostomy or cystoventriculostomy is the treatment of choice in patients with symptomatic intracranial arachnoid cysts. There are no objective diagnostic tests for reliable intraoperative evaluation of the effectiveness of performed stomies. The aim of this prospective open-label study is to demonstrate for the first time the usefulness of intraoperative cysternography performed with the low-field 0.15-T magnetic resonance imager Polestar N20 during endoscopic cysternostomies. The study was performed in patients operated for middle fossa arachnoid cysts (n = 10), suprasellar cysts (n = 4), paraventricular or intraventricular cysts (n = 6), and a pineal cyst (n = 1). The operations were performed with use of a navigated neuroendoscope. Intraoperative magnetic resonance (iMR) cysternography was performed before and after the cystostomy. In each case, iMR cysternography was safe and could show clearly the cyst morphology and the effectiveness of performed endoscopic cystostomies. In six cases, iMR cysternography had a significant influence of the surgical decision (p = 0.027). The rate of inconsistency between the intraoperative observations and iMR imaging–based findings was 29%. A good contrast flow through the fenestrated cyst walls correlated with a good long-term clinical outcome (ρ = 0.54, p < 0.05) and good long-term radiological outcome (ρ = 0.72, p < 0.05). Intraoperative low-field MR cysternography is a safe and reliable method for assessment of the efficacy of performed endoscopic cystostomies and has significant influence on the surgical decision. It may be reliably used for prediction of the long-term clinical and radiological outcome.


  • Usefulness of Intraoperative Magnetic Resonance Ventriculography During Endoscopic Third Ventriculostomy

    by Pawel Tabakow, Marcin Czyz, Pawel Szewczyk, Artur Weiser, Wlodzimierz Jarmundowicz

    Endoscopic third ventriculostomy (ETV) is the preferred method for the treatment of noncommunicating hydrocephalus. The different success rates of ETV indicate the difficulties in predicting the success of this procedure. To show the usefulness of intraoperative ventriculography performed by the low-field 0.15-T magnetic resonance imager Polestar N20 during ETV. The study was conducted in 11 patients with noncommunicating hydrocephalus caused by tumors or cysts of the third ventricle (n = 5), nontumoral stenosis of the sylvian aqueduct (n = 3), and fourth ventricle outlet obstruction (n = 3). Intraoperative magnetic resonance (iMR) ventriculography was performed before and after the ETV. In each case, iMR-ventriculography was a safe procedure and determined the exact site of obstruction of cerebrospinal fluid flow. In all cases, iMR-ventriculography performed after ETV showed with the greatest accuracy the patency of the performed fenestrations, demonstrating in 9 patients good flow of the contrast from the third ventricle to the basal cisterns, restricted flow in 1 patient, and no flow in 1 patient. The results of ventriculography were consistent with the postoperative neurological status of operated-on patients. In 3 patients, the opinion of the surgeons about the patency of endoscopic fenestration, based on intraoperative observation of the third ventricle floor, was inconsistent with the results from iMR-ventriculography. Low-field iMR-ventriculography is a safe procedure that can be successfully applied during ETV to determine the site of obstruction in hydrocephalus and the patency of performed ventricle fenestration.


  • Development of a tonometric sensor for measurement and recording of arterial pressure waveform

    by K. Tomczuk, M. Werszko, J. Z. Sasiadek, J. Kosek, W. Berny, A. Weiser, J. Feder-Kubis

    There are many techniques and devices for measurement and recording of arterial blood pressure. Some of them allow (enable) additionally to observe the shape of a wave of arterial pressure, which can be regarded as one of the most important diagnostic parameters of human cardiovascular system. This paper presents a novel design and prototype of a new, non-invasive blood waveform measuring device. It expounds theoretical and experimental (including latest preliminary clinical) results obtained during several years of extensive investigations into blood pressure waveform measuring and monitoring problem. According to investigations performed in the laboratory and preliminary clinical evaluation, the sensor has linear steady-state characteristics and satisfactory dynamic properties. It is an efficient and accurate tool for blood pressure waveform monitoring and assessing the cardiovascular condition of the patients. The novelty of this solution is that the device is equipped with a pneumatic pressure sensor based on the pneumatic nozzle flapper amplifier principle with negative feedback. Due to such a technical solution, the device does not require any cuff, which remains an essential component of the majority of contemporary non-invasive blood pressure measurement devices; therefore, it can be used on the artery where the application of a cuff would be impossible (e.g., carotid artery). This advantage makes possible to obtain an accurate shape of blood pressure waveform with high fidelity, comparable to a direct measurement method. Moreover, during the measurement the device converts directly “pressure into pressure.” Such a principle of operation makes possible to eliminate additional calibration (at the current stage of research we have eliminated the necessity of calibration in laboratory conditions).


  • Open Access

    The safety and effectiveness of low field intraoperative MRI guidance in frameless stereotactic biopsies of brain tumours—design and interim analysis of a prospective randomized trial

    by M. Czyż, P. Tabakow, A. Weiser, B. E. Lechowicz-Głogowska, L. W. Zub, W. Jarmundowicz

    The aim of the study was to assess the safety and effectiveness of stereotactic brain tumour biopsy (STx biopsy) guided by low-field intraoperative magnetic resonance imaging (iMRI) in comparison with its frameless classic analogue based on a prospective randomized trial. A pilot group of 42 brain tumour patients was prospectively randomized into a low-field iMRI group and a control group that underwent a frameless STx biopsy. The primary endpoints of the analysis were postoperative complication rate and diagnostic yield, and the secondary endpoints were length of hospital stay and duration of operation. The iMRI group (21 patients) and the control group (21 patients) did not differ significantly according to demographic and epidemiological data. No major postoperative complications were noted in either group. In addition, no significant differences in the diagnostic yield (p = 1.00) and length of hospital stay (p = 0.16) were observed. The mean total OR time was 111 ± 24 min in iMRI and 78 ± 29 min in the control group (p = 0.0001). Usage of iMRI may prolong the time of the procedure but seems to be comparable in safety and effectiveness to the standard frameless STx biopsy.


    • 12 December 2012
      • Vol. 21  (1) , 55-61

    Assessment of cerebral blood flow during infusion test in the diagnosis of normal pressure hydrocephalus.

    by Tomasz A Szczepański, Artur Weiser, Wojciech L Zub, Włodzimierz Jarmundowicz, Marta Koźba-Gosztyła, Bogdan Czapiga

    Many studies indicate that the increase in intracranial pressure (ICP) leads to cerebral blood flow velocity (CBFV) changes. This relationship was accurately determined in patients with traumatic brain injury, The aim of this study was to determine how the changes in intracranial pressure induced during an infusion test influence cerebral blood flow. 40 patients with enlarged ventricular systems (Evan's ratio > 30%) who underwent a diagnostic lumbar infusion test (LIT) were included. Tests were performed at the Department of Neurosurgery, Wroclaw Medical University. CBFV in the middle cerebral artery was measured using transcranial Doppler (TCD) simultaneously during the standard lumbar infusion test. TCD measurements were continued with simultaneous recording of CSF pressure with a frequency of 100Hz. A total number of 5800 measurements (10-second periods) performed during the three phases of the infusion test (stable, infusion and decrease) was obtained. In the stable phase of LIT, a weak positive correlation between ICP and mean CBFV (R = 0.193, p < 0.01) was observed. There was no statistically significant correlation between ICP and the pulsatility index (PI, Gosling Index). During the increased-ICP phase of LIT (infusion, decrease), we observed significant changes in CBFV expressed by a decrease of diastolic velocity and an increase of systolic velocity. A simultaneous increase of pulsation correlated with an increase in ICP (R = 0.371, p < 0.01). There were no significant changes in mean CBFV. In patients with ventriculomegaly, the mean cerebral blood flow is maintained despite a significant increase in ICP, within the limits of the infusion test. It is noted the relative increase of the pulsatility indices of CBF may indicate preserved cerebrovascular reactivity.