TRTiziana Rubeca

Tiziana Rubeca

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tiziana Rubeca has a total of 155 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 14 November 2017
      • Vol. 41, 1-31

    Guidance for faecal occult blood testing: quantitative immunochemical method (FIT-HB) in colorectal cancer screening programmes.

    by Tiziana Rubeca, Stefano Rapi, Silvia Deandrea, Morena Malaspina, Basilio Ubaldo Passamonti, Elena Grassi, Anna Maria Cioccarelli, Enrico Marchetti, Michela Boni, Filippo Cellai, et al.

    In Italy, colorectal cancer screening is included as part of the Italian National Health Service - SSN (Servizio Sanitario Nazionale) Essential Levels of Care - LEA (Livelli Essenziali Assistenziali) and the European Guidelines, which specify quantitative FIT-Hb testing as the best strategy for organised screening programmes. To ensure consistent operating standards in Member States, European regulations require the implementation of certification and accreditation requirements for diagnostic and care-related processes. The requirement, based on ISO 17021 accreditation standards, includes ISO 9001 certification for systems and ISO 15189:2012 accreditation for laboratories. various phases of the analytical process (pre-test, test, post-test) were evaluated in detail and provided operational guidelines for adjusting analytical and managerial procedures using: (a) feedback from members of GISCoR screening labs; (b) performance data obtained via a systematic review of the literature and the Osservatorio Nazionale Screening (ONS) Survey; (c) recommendations for laboratory practice issued by the World Endoscopy Organization "FIT for Screening" Working Group; (d) selected guidelines from the National Guidelines Clearinghouse database; and (e) Canadian, Australian and European screening programme websites. With respect to ISO 15189:2012 standards for accreditation of medical laboratories, GISCoR's guidance has been re-evaluated and revised by auditors from the Italian certification body (ACCREDIA) to assess its compliance and completeness with the aim of finalising operating procedures. the implementation and maintenance of operational standards required by complex systems (e.g. screening programmes) involving constant interaction between facilities and the supporting organisational structure are not easy to achieve. The guide aims to provide laboratories with the necessary guidance for proper process management.


  • Effects of Fecal Sampling on Preanalytical and Analytical Phases in Quantitative Fecal Immunochemical Tests for Hemoglobin

    by Stefano Rapi, Margherita Berardi, Filippo Cellai, Samuele Ciattini, Laura Chelazzi, Agostino Ognibene, Tiziana Rubeca

    Background: Information on preanalytical variability is mandatory to bring laboratories up to ISO 15189 requirements. Fecal sampling is greatly affected by lack of harmonization in laboratory medicine. The aims of this study were to obtain information on the devices used for fecal sampling and to explore the effect of different amounts of feces on the results from the fecal immunochemical test for hemoglobin (FIT-Hb). Methods: Four commercial sample collection devices for quantitative FIT-Hb measurements were investigated. The volume of interest (VOI) of the probes was measured from diameter and geometry. Quantitative measurements of the mass of feces were carried out by gravimetry. The effects of an increased amount of feces on the analytical environment were investigated measuring the Hb values with a single analytical method. Results: VOI was 8.22, 7.1 and 9.44 mm3 for probes that collected a target of 10 mg of feces, and 3.08 mm3 for one probe that targeted 2 mg of feces. The ratio between recovered and target amounts of devices ranged from 56% to 121%. Different changes in the measured Hb values were observed, in adding increasing amounts of feces in commercial buffers. Conclusions: The amounts of collected materials are related to the design of probes. Three out 4 manufacturers declare the same target amount using different sampling volumes and obtaining different amounts of collected materials. The introduction of a standard probes to reduce preanalytical variability could be an useful step for fecal test harmonization and to fulfill the ISO 15189 requirements.


  • Impact of a new sampling buffer on faecal haemoglobin stability in a colorectal cancer screening programme by the faecal immunochemical test

    by Grazia Grazzini, Leonardo Ventura, Tiziana Rubeca, Stefano Rapi, Filippo Cellai, Pietro P. Di Dia, Beatrice Mallardi, Paola Mantellini, Marco Zappa, Guido Castiglione

    Haemoglobin (Hb) stability in faecal samples is an important issue in colorectal cancer screening by the faecal immunochemical test (FIT) for Hb. This study evaluated the performance of the FIT-Hb (OC-Sensor Eiken) used in the Florence screening programme by comparing two different formulations of the buffer, both in an analytical and in a clinical setting. In the laboratory simulation, six faecal pools (three in each buffer type) were stored at different temperatures and analysed eight times in 10 replicates over 21 days. In the clinical setting, 7695 screenees returned two samples, using both the old and the new specimen collection device (SCD). In the laboratory simulation, 5 days from sample preparation with the buffer of the old SCD, the Hb concentration decreased by 40% at room temperature (25°C, range 22–28°C) and up to 60% at outside temperature (29°C, range 16–39°C), whereas with the new one, Hb concentration decreased by 10%. In the clinical setting, a higher mean Hb concentration with the new SCD compared with the old one was found (6.3 vs. 5.0 µg Hb/g faeces, respectively, P<0.001); no statistically significant difference was found in the probability of having a positive result in the two SCDs. Better Hb stability was observed with the new buffer under laboratory conditions, but no difference was found in the clinical performance. In our study, only marginal advantages arise from the new buffer. Improvements in sample stability represent a significant target in the screening setting.


  • A comparative effectiveness trial of two faecal immunochemical tests for haemoglobin (FIT). Assessment of test performance and adherence in a single round of a population-based screening programme for colorectal cancer

    by Basilio Passamonti, Morena Malaspina, Callum G Fraser, Beatrice Tintori, Angela Carlani, Valentina D'Angelo, Paola Galeazzi, Eugenio Di Dato, Loretta Mariotti, Simonetta Bulletti, et al.

    Aim To compare acceptability and diagnostic accuracy of a recently available faecal immunochemical test (FIT) system (HM-JACKarc) with the FIT routinely used in an established screening programme (OC-Sensor). Design Randomised controlled trial (ISRCTN20086618) within a population-based colorectal cancer (CRC) screening programme. Subjects eligible for invitation in the Umbria Region (Italy) programme were randomised (ratio 1:1) to be screened using one of the FIT systems. Results Screening uptake among the 48 888 invitees was the same for both systems among subjects invited in the first round and higher with OC-Sensor than with HM-JACKarc (relative risk (RR): 1.03; 95% CI 1.02 to 1.04) among those invited in subsequent rounds. Positivity rate (PR) was similar with OC-Sensor (6.5%) as with HM-JACKarc (6.2%) among subjects performing their first FIT screening and higher with OC-Sensor (5.6%, RR: 1.25, 95% CI 1.12 to 1.40) than with HM-JACKarc (4.4%) among those screened in previous rounds. Positive predictive value (PPV) (OC-Sensor: 25.9%, HM-JACKarc: 25.6%) and detection rate (DR) (OC-Sensor: 1.40%; HM-JACKarc: 1.42%) for advanced neoplasia (AN: CRC + advanced adenoma) were similar among subjects performing their first FIT screening. The differences in the AN PPV (OC-Sensor: 20.3%, HM-JACKarc: 22.6%) and DR (OC-Sensor: 0.96%, HM-JACKarc: 0.83%) among those screened in previous rounds were not statistically significant. The number needed to scope to detect one AN was 3.9 (95% CI 5.8 to 2.9) and 3.9 (95% CI 5.5 to 2.9) at first and 4.9 (95% CI 5.8 to 4.2) and 4.4 (95% CI 5.3 to 3.7) at subsequent screening, with OC-Sensor and HM-JACKarc, respectively. Conclusions Our results suggest that acceptability and diagnostic performance of HM-JACKarc and of OC-Sensor systems are similar in a screening setting. Trial registration number ISRCTN20086618; Results.


  • Impact of Preanalytical Factors on Fecal Immunochemical Tests: Need for New Strategies in Comparison of Methods

    by Tiziana Rubeca, Filippo Cellai, Massimo Confortini, Callum G. Fraser, Stefano Rapi

    Background: Harmonization of fecal immunochemical tests for hemoglobin (FIT-Hb) is crucial to compare clinical outcomes in screening programs. The lack of reference materials and standard procedures does not allow the use of usual protocols to compare methods. We propose 2 protocols, based on artificial biological samples (ABS), to discriminate preanalytical and analytical variation and investigate clinical performances. The protocols were used to compare 2 FIT systems available on European markets: the OC-Sensor Diana (Eiken, Tokyo, Japan) and HM-JACKarc (Kyowa-Medex, Tokyo, Japan). Methods: ABS were obtained adding Hb to Hb-free feces. In the first procedure, 35 ABS were collected for each collection device and analyzed on both systems. In the second, 188 ABS (106 positive and 82 negative) were ­collected and tested on the specific systems. Passing-Bablock (PB), Pearson's correlation coefficients (R) and Bland-Altman difference analysis were used to compare data. Results: PB, R and mean standard errors for Bland-Altman analysis (Diana vs. Arc) results were 0.93x-0.56: R = 0.97 and 19%; and 1.09x + 5.60: R = 0.96 and −18%; for Diana and Arc devices, respectively. No correlations and no difference in positive/negative assessment were observed with the second protocol. Conclusions: A good correlation was observed in comparing data generated using collection devices on the 2 systems. Manufacturers have developed different sample collection procedures for feces: therefore, data from different systems cannot easily be compared. Adoption of protocols to discriminate preanalytical and analytical variation would be a significant contribution to harmonization of FIT, facilitating data comparison and information acquisition for sample collection strategy and effect of buffers on systems.


  • How to improve the performances of Fecal Immunological Tests (FIT): Need for standardization of the sampling and pre-analytical phases and revision of the procedures for comparison of methods

    by Stefano Rapi, Tiziana Rubeca, Callum G. Fraser

    Lack of reference materials and standard procedures, on faecal tests leads to major problems in harmonisation of methods and do not allow the comparison of outcome data. In particular the absence of standardisation of pre-analytical characteristic was noted for faecal test methods for haemoglobin since different manufacturers have developed different sampling procedures and report units. Moreover the physical characteristics of the faecal specimen and the designs of specimen collection devices do not allow analysis of samples on different systems in consequence, faecal tests cannot be compared using standard evaluation protocols. To improve the harmonization of results generated using different analytical systems and the overall performances of test on faecal materials we propose the introduction of standard procedures for sampling and pre-analytical phase and the adoption of specific procedures based on the use of artificial biological samples for comparison of methods. Harmonization of sampling devices with the use of a standard design for pickers and a standard ratio between analyte and buffer for different manufacturers represent a mandatory step in the roadmap for harmonization of clinical laboratory measurement on faecal materials and can allow a significant standardisation of results generated by different devices. The creation of specific protocols for the evaluation and comparison of analytical methods for analyse of faeces could lead to a significant improvement in the performance of methods and systems.


  • The impact of immunochemical faecal occult blood testing on colorectal cancer incidence

    by Leonardo Ventura, Paola Mantellini, Grazia Grazzini, Guido Castiglione, Carlotta Buzzoni, Tiziana Rubeca, Claudio Sacchettini, Eugenio Paci, Marco Zappa


  • Faecal haemoglobin concentrations vary with sex and age, but data are not transferable across geography for colorectal cancer screening

    by Callum G. Fraser, Tiziana Rubeca, Stefano Rapi, Li-Sheng Chen, Hsiu-Hsiu Chen

    Faecal immunochemical tests (FIT) are becoming widely used in colorectal cancer (CRC) screening. Availability of data on faecal haemoglobin concentrations (f-Hb) in three countries prompted an observational study on sex and age and the transferability of data across geography. Single estimates of f-Hb in large groups were made in Scotland, Taiwan and Italy using quantitative automated immunoturbidimetry on the Eiken OC-Sensor. Distributions were examined for men and women overall and in four different age groups. The distributions of f-Hb were not Gaussian and had kurtosis and positive skewness. The distributions were different in the three countries: f-Hb varies with sex and age in all countries, being higher in men and the elderly, but the degree of variation is inconsistent across countries, f-Hb being higher in Scotland than in Taiwan than in Italy, possibly due to different lifestyles. At any cut-off concentration, more men are declared positive than women and more older people are declared positive than younger individuals. Our analysis supports the view that setting and using a single f-Hb cut-off in any CRC screening programme is far from ideal. We suggest that individualisation is the optimum approach with f-Hb, alone or with other important factors such as sex and age, used to determine important personal issues such as need for colonoscopy, screening interval between tests and risk of future CRC. Whether there is merit in monitoring f-Hb in individuals over time remains an interesting research question for the future.


  • Overall evaluation of an immunological latex agglutination system for fecal occult blood testing in the colorectal cancer screening program of Florence

    by Tiziana Rubeca, Benedetta Peruzzi, Massimo Confortini, Stefano Rapi

    Several immunological fecal occult blood tests (FOBT) are currently available for colorectal cancer (CRC) screening. We compared the HM Jack (Jack) (Kiowa, Japan), with the OC-Hemodia (OC) (Eiken, Japan) in use in the Florence screening program. Aims of the study were: (i) to investigate the diagnostic performance and the best cutoff value for Jack; (ii) to evaluate the handiness of sampling tubes; (iii) to compare costs. A total of 5,044 subjects were screened with both tests. Sampling tube investigation was performed running each sample on both instruments. A number of 352 subjects positive for at least one test (175 OC, 310 Jack) were selected for further investigations, while 46 subjects refused further assessments. Analysis of costs related to the assessment phase was performed on the basis of Tuscany region's fares. Amongst the 306 subjects investigated, 9 CRC and 67 advanced adenomas (AdA) were detected. Detection rates (DR) were 1.4‰ for CRC and 9.6‰ for AdA. After Jack cutoff optimization, DR for CRC+AdA resulted in 11.1‰ for OC and 13.3‰ for Jack (p=0.041). Sensitivity of the methods was 73.7 for OC and 88.2 for Jack; specificity was 97.6 for OC and 96.0 for Jack, resulting in an increase of the required assessments from 3.5% to 5.1%. No differences were observed between sampling methods. Despite the lower specificity of Jack, its greater sensitivity makes the method attractive for screening programs. An increase of the costs of 30% for every subject investigated for pathological lesion (CRC+AdA) may be thus foreseen.