FGFranck Gonzalez

Franck Gonzalez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Franck Gonzalez has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Florian Gosselin

    CEA, LIST, Interactive Robotics Laboratory, F-91190 Gif-sur-Yvette, FRANCE

    4 shared publications
  • Wael Bachta

    Sorbonne Universitès, UPMC Univ Paris 06, CNRS UMR 7222, INSERM U 1150, Institut des Systèmes Intelligents et de Robotique, Equipe Agathe, Paris, France

    3 shared publications
  • Anthony Chabrier

    CEA, LIST, Interactive Robotics Laboratory, F-91190 Gif-sur-Yvette, France, Sorbonne Universités, UPMC Univ, Paris 06, CNRS, UMR 7222, INSERM, UI 1150, Institut des Systèmes Intelligents et de Robotique, F-75005, Paris, France

    2 shared publications
  • Etienne Burdet

    Imperial College of Science, Technology and Medicine

    2 shared publications
  • Wael Bachta

    CEA, LIST, Interactive Robotics Laboratory, F-91190 Gif-sur-Yvette, FRANCE

    2 shared publications
  • Alessandro Donadio

    Department of Engineering, Universita Campus Bio-Medico di Roma, Roma, ITALY

    1 shared publication

Latest Publications

  • Contributions au développement d'une interface haptique à contacts intermittents

    by Franck Gonzalez

    Les interfaces haptiques permettent à un opérateur d'interagir avec un environnement virtuel ou distant via le sens du toucher.La majorité des interfaces de l'état de l'art restent au contact de l’utilisateur pendant toute la durée de la manipulation. La liaison permanente entre le robot et l’opérateur nuit à la qualité de l’interaction, notamment en réduisant la transparence en espace libre. Ce problème est d’autant plus prégnant dans le cadre des interfaces haptiques dextres.Cette thèse a pour objectif d'étudier la possibilité d'augmenter la transparence et le réalisme de l'interaction à travers le développement d’interfaces à contacts intermittents. Il s’agit de déconnecter le robot de l'utilisateur lorsqu’aucun contact avec l’environnement n’est nécessaire. Un état de l’art des performances de la manipulation humaine, des interfaces haptiques dextres ainsi que des travaux relatifs au contact intermittent, est d’abord présenté. Un effecteur plan pour le contact intermittent est ensuite conçu. Il est installé à l’extrémité distale d'une interface haptique et plusieurs solutions sont envisagées pour sa loi de commande. Les performances de dix utilisateurs sont comparées dans le cadre d'une tâche de détection de contact en utilisant d'une part l'effecteur adapté au contact intermittent, d'autre part une interface haptique classique. L'élaboration d'une interface permettant une interaction plus naturelle avec l'environnement est ensuite initiée par l'élaboration d'une méthodologie de choix des zones de contact de la main à prendre en compte dans la conception d'une interface haptique. Des perspectives sont finalement données quant à l'extension de ces résultats à une interface haptique dextre à contacts intermittents.

  • Open Access

    Differential game theory for versatile physical human–robot interaction

    by Y. Li, G. Carboni, F. Gonzalez, D. Campolo, E. Burdet


  • Open Access

    A novel sensor design for accurate measurement of facial somatosensation in pre-term infants

    by Alessandro Donadio, Kimberley Whitehead, Franck Gonzalez, Elisabeth Wilhelm, Domenico Formica, Judith Meek, Lorenzo Fabrizi, Etienne Burdet

    Facial somatosensory feedback is critical for breastfeeding in the first days of life. However, its development has never been investigated in humans. Here we develop a new interface to measure facial somatosensation in newborn infants. The novel system allows to measure neuronal responses to touching the face of the subject by synchronously recording scalp electroencephalography (EEG) and the force applied by the experimenter. This is based on a dedicated force transducer that can be worn on the finger underneath a clinical nitrile glove and linked to a commercial EEG acquisition system. The calibrated device measures the pressure applied by the investigator when tapping the skin concurrently with the resulting brain response. With this system, we were able to demonstrate that taps of 192 mN (mean) reliably elicited facial somatosensory responses in 7 pre-term infants. These responses had a time course similar to those following limbs stimulation, but more lateral topographical distribution consistent with body representations in primary somatosensory areas. The method introduced can therefore be used to reliably measure facial somatosensory responses in vulnerable infants.


  • Design and experimental evaluation of an infrared instrumentation for haptic interfaces

    by Anthony Chabrier, Franck Gonzalez, Florian Gosselin, Wael Bachta

    This paper presents the design and experimental evaluation of the end-effector of a dexterous encounter type haptic interface aimed at allowing natural interactions with digital mockups in Virtual Reality. This end-effector has two purposes: first, it should be able to precisely measure the 6D position and orientation of a fingertip remotely without equipping the user with any marker on the skin or nail. Second, it should serve as contact surface when force feedback is required. Therefore, we make use of 9 proximity sensors, 8 of which are placed around the finger in two planes, the last one being in front of it. Our results show that, after calibration, this configuration effectively allows measuring the configuration of a mock-up representative of the finger with a good precision for various positions and orientations.


  • Analysis of the directions in which forces are applied on the hand during manual manipulation and exploration

    by Anthony Chabrier, Franck Gonzalez, Florian Gosselin, Wael Bachta

    Haptic interfaces aim at realistically simulating physical interactions within a Virtual Environment (VE) through the sense of touch. Therefore, they should display both a negligible impedance in free space and high forces and stiffness in contact. These constraints are however difficult to meet simultaneously. While compromises can usually be found when interacting through a handle grasped in hand, this is much more difficult when considering dexterous interactions with manual interfaces or exoskeletons due to the high number of degrees of freedom and limited space available. To ease their design, the authors previously made an analysis of the hand contact areas of interest for the simulation of the majority of interactions in a VE. It was shown that tracking and providing force feedback only on the five fingertips and the side of the index allows interacting naturally within a VE more than 50% of the time. This paper goes a step further and analyses in which directions these forces are applied on each hand area. A new result is that forces are required on the 6 areas of interest only normal to the skin, while tangential forces can be limited to 4 and even 1 area(s) depending on the direction.


  • Smooth transition-based control of encounter-type haptic devices

    by Franck Gonzalez, Wael Bachta, Florian Gosselin

    Encounter-type devices have been introduced to solve one of the main drawbacks of common haptic interfaces i.e. their limited transparency in free space and their restricted ability to render realistic transitions between free space and contact. Advantageously, encounter-type interfaces collide with fingers and display interaction forces only if a contact occurs in the virtual environment. In free space, their end-effectors are mechanically detached from the operator and closely track his fingers, allowing for a perfect transparency. This paper introduces a control scheme that handles the transition between tracking and force display modes in a smooth way. Experimental results using a custom encounter-type interface are also given. The obtained results show the efficiency of the proposed control law when compared to the conventional switch-based control usually found in the literature.


  • Open Access

    A 2-D Infrared Instrumentation for Close-Range Finger Position Sensing

    by Franck Gonzalez, Florian Gosselin, Wael Bachta

    Haptic interfaces are proposed for enhancing human-computer interfaces through the rendering of interaction forces. Among them, encounter-type haptic displays feature an original way to provide the user with an improved transparency: their end effectors remotely track the fingers of the operator and encounter them only when force rendering is required. These interfaces call for the development of specific position tracking systems. In this paper, a 2-D hollow instrumentation for remote and marker-free close-range finger tracking is proposed. It encloses 16 infrared proximity sensors. Its design specifications are based on a literature review of finger motion and a simulation of the tracking dynamics. Some calibration methods, organized as a function of their complexity level, are also described. The instrumentation performances are experimentally evaluated to assess its adequacy with the targeted application. This design accounts for the demonstration that infrared proximity sensing is a viable solution for close-range sensing of targets as changing as human body parts.


  • A framework for the classification of dexterous haptic interfaces based on the identification of the most frequently used hand contact areas

    by Franck Gonzalez, Florian Gosselin, Wael Bachta

    Haptic interfaces are purposed for the simulation of physical interactions with a virtual environment in a realistic way. Their design is often based on a compromise between the interaction capabilities and mechanical design complexity. This paper is aimed at providing a methodology that helps tuning this trade-off. A survey of both manipulation and exploration taxonomies allows the identification of elementary hand contact areas with their associated frequency of use. The relative importance of these areas is illustrated by the building of an interaction map for the hand. Some combinations of these elementary areas, with their frequency of use, are then organised into a graphical tree as a function of their complexity. This tree allows to review some existing devices and to propose some guidelines for improved designs.