Lei Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lei Liu has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
Yang-Guo Li
The Univ. of Alabama at Birmingham (United States)
7 shared publicationsClifton M. Schor
School of Optometry, University of California, Berkeley, Berkeley, California 94720
5 shared publicationsXin-Cheng Yao
The Univ. of Alabama at Birmingham (United States)
5 shared publications- Qiu-Xiang Zhang
Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294
4 shared publications Christopher W. Tyler
Smith-Kettlewell Eye Research Institute (USA)
3 shared publicationsCong Yu
School of Psychological and Cognitive Sciences IDG/McGovern Institute for Brain Research, and Peking‐Tsinghua Center for Life Sciences Peking University Beijing China
3 shared publications
Latest Publications
- 24 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Quantitative Comparison of Flux Regulation Capability of Integrated-Induction-Based Hybrid Excitation Machines with Spoke-Type and Consequent-Pole PM Rotors
In recent years, hybrid excitation machine (HEM) drawn much attention due to their preferred flux regulation than permanent magnet (PM) machine. The integrated-induction-based HEM (II-HEM) achieves both the brushless excitation and flexible flux regulation while the high space utilization is obtained. This paper aims to quantitative comparison of flux regulation capability between the novel II-HEM adopting consequent-pole PM rotor and the conventional counterparts adopting spoke-type PM rotor. The flux regulation principle of the two II-HEMs are revealed based on equivalent magnetic circuit model, and validated by finite-element (FE) method. Then, the regulation coefficient kf is defined for evaluating the flux regulation capability, in which the actual saturation effect is considered. It is demonstrated that the novel II-HEM with consequent-pole PM rotor obtains better flux regulation capability than the conventional one.
- 24 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Quantitative Comparison of Flux Regulation Capability of Integrated-Induction-Based Hybrid Excitation Machines with Spoke-Type and Consequent-Pole PM Rotors
In recent years, hybrid excitation machine (HEM) drawn much attention due to their preferred flux regulation than permanent magnet (PM) machine. The integrated-induction-based HEM (II-HEM) achieves both the brushless excitation and flexible flux regulation while the high space utilization is obtained. This paper aims to quantitative comparison of flux regulation capability between the novel II-HEM adopting consequent-pole PM rotor and the conventional counterparts adopting spoke-type PM rotor. The flux regulation principle of the two II-HEMs are revealed based on equivalent magnetic circuit model, and validated by finite-element (FE) method. Then, the regulation coefficient kf is defined for evaluating the flux regulation capability, in which the actual saturation effect is considered. It is demonstrated that the novel II-HEM with consequent-pole PM rotor obtains better flux regulation capability than the conventional one.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Day-Ahead Economic Optimal Operation Plan Based Real-Time Dispatch for Power Grid with High Proportion of New Energies
To improve the operational economy, grids with distributed wind power, photovoltaic, and gas turbine are often operated according to the day-ahead economic optimal plan. However, due to the limitation of load and generation power forecasting technology, the real-time load and generation power in the grid often have a large deviation from the day-ahead forecasting results. To ensure the power balance in the grid, real-time operation requires correcting the day-ahead plan, which also affects the economics of the grid. In this paper, a real-time dispatch strategy is proposed, which is based on the day-ahead economic optimal operation plan. With two-stage real-time correction and rolling dispatch technology, the economy of the day-ahead operation plan is guaranteed to the greatest extent with the requirement of power balance. Finally, the case results verify the effectiveness of the proposed real-time dispatch strategy.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Day-Ahead Economic Optimal Operation Plan Based Real-Time Dispatch for Power Grid with High Proportion of New Energies
To improve the operational economy, grids with distributed wind power, photovoltaic, and gas turbine are often operated according to the day-ahead economic optimal plan. However, due to the limitation of load and generation power forecasting technology, the real-time load and generation power in the grid often have a large deviation from the day-ahead forecasting results. To ensure the power balance in the grid, real-time operation requires correcting the day-ahead plan, which also affects the economics of the grid. In this paper, a real-time dispatch strategy is proposed, which is based on the day-ahead economic optimal operation plan. With two-stage real-time correction and rolling dispatch technology, the economy of the day-ahead operation plan is guaranteed to the greatest extent with the requirement of power balance. Finally, the case results verify the effectiveness of the proposed real-time dispatch strategy.
- 1 September 2020
- Published by Elsevier in Vision Research
- Vol. 174, 69-76
A new perceptual training strategy to improve vision impaired by central vision loss
- 1 September 2020
- Published by Elsevier in Vision Research
- Vol. 174, 69-76
A new perceptual training strategy to improve vision impaired by central vision loss
- 6 March 2020
- Published by Optica Publishing Group in OSA Continuum
- Vol. 3 (3) , 620-628
Holographic waveguide based optometer for the quantitative monitoring of ocular refractive error
Oculomotor disorders are known to have profound impacts on a patients’ quality of life. However, current clinical practice lacks the capability to provide simultaneous assessment of three tightly coupled oculomotor control components, i.e. eye movement, lens accommodation, and pupil response. In this study, a holographic waveguide (HW) based benchtop optometer was constructed and evaluated with a model eye. Experimental result and quantitative analysis indicate that a HW can convey high quality retinal images to a camera at an illumination level safe for human subjects and support high accuracy measurements of ocular refractive error over a wide range. Further development of a HW-based system promises a wearable, see-through device for comprehensive assessment of oculomotor control components while the subject is engaged in normal daily activities and thus enable advanced research and clinical management of oculomotor disorders.
- 6 March 2020
- Published by Optica Publishing Group in OSA Continuum
- Vol. 3 (3) , 620-628
Holographic waveguide based optometer for the quantitative monitoring of ocular refractive error
Oculomotor disorders are known to have profound impacts on a patients’ quality of life. However, current clinical practice lacks the capability to provide simultaneous assessment of three tightly coupled oculomotor control components, i.e. eye movement, lens accommodation, and pupil response. In this study, a holographic waveguide (HW) based benchtop optometer was constructed and evaluated with a model eye. Experimental result and quantitative analysis indicate that a HW can convey high quality retinal images to a camera at an illumination level safe for human subjects and support high accuracy measurements of ocular refractive error over a wide range. Further development of a HW-based system promises a wearable, see-through device for comprehensive assessment of oculomotor control components while the subject is engaged in normal daily activities and thus enable advanced research and clinical management of oculomotor disorders.
- 1 March 2020
- Published by IOP Publishing in Physiological Measurement
- Vol. 41 (3) , 035005
Correlating the passive response of eye and brain to head impact using MEMS IMUs on 3D-printed human head phantom
Objective: The eye may act as a surrogate for the brain in response to head acceleration during an impact. This paper reports the latest demonstration of the correlation between the passive human eye accelerations and the brain accelerations under head impacts using a model eye/brain/skull phantom. Approach: Experiments investigating rotational and linear accelerations were performed on a 3D-printed human head phantom, along with rotational experiments on a human volunteer. Data acquired during the passive eye response (PER) periods were processed and analysed using statistical methods including one-way normal analysis of variance, linear regression fit, and Pearson R correlation. Main results: The results have shown that, at least on the 3D-printed human head phantom, strong correlations can be found between the eye and the brain during the PER, which indicates a potential use of microelectromechanical systems inertial measurement units in real-time on-field monitoring and diagnosis of concussions or traumatic brain injuries. Significance: These discoveries pave the way for potential non-invasive wearable devices based on this technology to be applied in real-time on-field concussion monitoring, which is expected to provide vulnerable parties with instant alert thus timely treatment.
- 1 March 2020
- Published by IOP Publishing in Physiological Measurement
- Vol. 41 (3) , 035005
Correlating the passive response of eye and brain to head impact using MEMS IMUs on 3D-printed human head phantom
Objective: The eye may act as a surrogate for the brain in response to head acceleration during an impact. This paper reports the latest demonstration of the correlation between the passive human eye accelerations and the brain accelerations under head impacts using a model eye/brain/skull phantom. Approach: Experiments investigating rotational and linear accelerations were performed on a 3D-printed human head phantom, along with rotational experiments on a human volunteer. Data acquired during the passive eye response (PER) periods were processed and analysed using statistical methods including one-way normal analysis of variance, linear regression fit, and Pearson R correlation. Main results: The results have shown that, at least on the 3D-printed human head phantom, strong correlations can be found between the eye and the brain during the PER, which indicates a potential use of microelectromechanical systems inertial measurement units in real-time on-field monitoring and diagnosis of concussions or traumatic brain injuries. Significance: These discoveries pave the way for potential non-invasive wearable devices based on this technology to be applied in real-time on-field concussion monitoring, which is expected to provide vulnerable parties with instant alert thus timely treatment.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3995-4000
Thermoacoustic Generation System for the Maximum Acoustic Power Capturing Based on Controllable Electric Load
An acoustic impedance matching method based on controllable electric load was proposed. This method can make TAEGS (Thermoacoustic Generation System) acoustic impedance matching so that generator captures the maximum acoustic power by the optimum design spring mechanical impedance and load capacitance. Firstly, according to similarity theorem and TAEGS acoustic impedance current source mechanism with the maximum acoustic power capturing electric load, the acoustic power model was established by the phasor method like in the circuit, the relationship of the acoustic power function with parameters of system components is derived. Secondly, the double threshold optimization design from generator spring stiffness coefficient and load capacitance parameter for the maximum acoustic power capturing was given, which regarded generator safe operation as the constraint conditions. Finally, numerical calculation and experimental verified the feasibility and validity of this method.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3995-4000
Thermoacoustic Generation System for the Maximum Acoustic Power Capturing Based on Controllable Electric Load
An acoustic impedance matching method based on controllable electric load was proposed. This method can make TAEGS (Thermoacoustic Generation System) acoustic impedance matching so that generator captures the maximum acoustic power by the optimum design spring mechanical impedance and load capacitance. Firstly, according to similarity theorem and TAEGS acoustic impedance current source mechanism with the maximum acoustic power capturing electric load, the acoustic power model was established by the phasor method like in the circuit, the relationship of the acoustic power function with parameters of system components is derived. Secondly, the double threshold optimization design from generator spring stiffness coefficient and load capacitance parameter for the maximum acoustic power capturing was given, which regarded generator safe operation as the constraint conditions. Finally, numerical calculation and experimental verified the feasibility and validity of this method.
- 24 May 2019
- Published by Elsevier
- p. 145-162
Modeling and robust control of spacecraft with flexible attachment
- 24 May 2019
- Published by Elsevier
- p. 145-162
Modeling and robust control of spacecraft with flexible attachment
- 15 May 2019
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 66 (12) , 1311-1317
A holographic waveguide based eye tracking device
We demonstrated the feasibility of using a holographic waveguide imager for eye tracking. A holographic waveguide placed in front of the eye was used to capture images of the anterior segment of the eye and to guide the images to a camera distant from the eye. The pupil centre (PC) and corneal reflection (CR) of the eye was used to compute eye position. A custom-built model eye was used to validate the prototype eye tracker. A linear relationship between the angular eye position and the PC/CR vector was found over 60 horizontal degrees and 40 vertical degrees. The tracking accuracy and precision were 0.72 degree and 0.50 degree over these tracking ranges. These results confirmed that holographic waveguide could be a viable platform for developing compact, wearable, see-through eye trackers that can continuously monitor eye movements during real life tasks and thus can facilitate diagnosis of oculomotor disorders.
- 15 May 2019
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 66 (12) , 1311-1317
A holographic waveguide based eye tracking device
We demonstrated the feasibility of using a holographic waveguide imager for eye tracking. A holographic waveguide placed in front of the eye was used to capture images of the anterior segment of the eye and to guide the images to a camera distant from the eye. The pupil centre (PC) and corneal reflection (CR) of the eye was used to compute eye position. A custom-built model eye was used to validate the prototype eye tracker. A linear relationship between the angular eye position and the PC/CR vector was found over 60 horizontal degrees and 40 vertical degrees. The tracking accuracy and precision were 0.72 degree and 0.50 degree over these tracking ranges. These results confirmed that holographic waveguide could be a viable platform for developing compact, wearable, see-through eye trackers that can continuously monitor eye movements during real life tasks and thus can facilitate diagnosis of oculomotor disorders.
- 29 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (1) , 182-191
Sensing Passive Eye Response to Impact Induced Head Acceleration Using MEMS IMUs
The eye may act as a surrogate for the brain in response to head acceleration during an impact. Passive eye movements in a dynamic system are sensed by microelectromechanical systems (MEMS) inertial measurement units (IMU) in this paper. The technique is validated using a three-dimensional printed scaled human skull model and on human volunteers by performing drop-and-impact experiments with ribbon-style flexible printed circuit board IMUs inserted in the eyes and reference IMUs on the heads. Data are captured by a microcontroller unit and processed using data fusion. Displacements are thus estimated and match the measured parameters. Relative accelerations and displacements of the eye to the head are computed indicating the influence of the concussion causing impacts.
- 29 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (1) , 182-191
Sensing Passive Eye Response to Impact Induced Head Acceleration Using MEMS IMUs
The eye may act as a surrogate for the brain in response to head acceleration during an impact. Passive eye movements in a dynamic system are sensed by microelectromechanical systems (MEMS) inertial measurement units (IMU) in this paper. The technique is validated using a three-dimensional printed scaled human skull model and on human volunteers by performing drop-and-impact experiments with ribbon-style flexible printed circuit board IMUs inserted in the eyes and reference IMUs on the heads. Data are captured by a microcontroller unit and processed using data fusion. Displacements are thus estimated and match the measured parameters. Relative accelerations and displacements of the eye to the head are computed indicating the influence of the concussion causing impacts.
- 1 June 2017
- Published by Wiley in Optometry and Vision Science
- Vol. 94 (6) , 714-724
Developing a Logarithmic Chinese Reading Acuity Chart
Purpose: An individual’s reading ability cannot be reliably predicted from his/her letter acuity, contrast sensitivity, and visual field extent. We developed a set of Chinese reading acuity charts (C‐READ) to assess the reading ability of Chinese readers, based on the collective wisdom of previously published reading acuity charts, especially the MNRead and the Radner Reading Charts. Methods: The C‐READ consists of three charts. Each consists sixteen 12‐character simplified Chinese sentences crafted from first‐ to third‐grade textbooks. One hundred eighteen native Chinese‐speaking college students (aged 22.1 ± 2.1 years) with normal or corrected to normal near vision (−0.26 ± 0.05 logMAR) were included in the study to develop the C‐READ charts, to test the homogeneity of the three charts, and to validate the C‐READ against the text paragraphs from the International Reading Speed Texts (IReST) with corrected and uncorrected near vision. Results: The reading acuity, critical print size, and maximum reading speed for young normal native Chinese‐speaking readers were 0.16 ± 0.05 logMAR, 0.24 ± 0.06 logMAR, and 273.44 ± 34.37 characters per minute (mean ± SD), respectively. The reliability test revealed no significant differences among the three C‐READ charts and no significant test order effect in the three reading parameters. Regression analyses showed that the IReST reading speed could be reliably predicted by the C‐READ maximum reading speed under the corrected near‐vision condition (adjusted R 2 = 0.72) and by C‐READ maximum reading speed and critical print size under the uncorrected near‐vision condition (adjusted R 2 = 0.69). Conclusions: The three C‐READ charts are very comparable to each other, and there is no significant order effect. Reading test results can accurately predict continuous text reading performance quantified by the IReST reading speed over a wide range of refractive errors. The C‐READ is a reliable and valid clinical instrument for quantifying reading performance in simplified Chinese readers.
- 1 June 2017
- Published by Wiley in Optometry and Vision Science
- Vol. 94 (6) , 714-724
Developing a Logarithmic Chinese Reading Acuity Chart
Purpose: An individual’s reading ability cannot be reliably predicted from his/her letter acuity, contrast sensitivity, and visual field extent. We developed a set of Chinese reading acuity charts (C‐READ) to assess the reading ability of Chinese readers, based on the collective wisdom of previously published reading acuity charts, especially the MNRead and the Radner Reading Charts. Methods: The C‐READ consists of three charts. Each consists sixteen 12‐character simplified Chinese sentences crafted from first‐ to third‐grade textbooks. One hundred eighteen native Chinese‐speaking college students (aged 22.1 ± 2.1 years) with normal or corrected to normal near vision (−0.26 ± 0.05 logMAR) were included in the study to develop the C‐READ charts, to test the homogeneity of the three charts, and to validate the C‐READ against the text paragraphs from the International Reading Speed Texts (IReST) with corrected and uncorrected near vision. Results: The reading acuity, critical print size, and maximum reading speed for young normal native Chinese‐speaking readers were 0.16 ± 0.05 logMAR, 0.24 ± 0.06 logMAR, and 273.44 ± 34.37 characters per minute (mean ± SD), respectively. The reliability test revealed no significant differences among the three C‐READ charts and no significant test order effect in the three reading parameters. Regression analyses showed that the IReST reading speed could be reliably predicted by the C‐READ maximum reading speed under the corrected near‐vision condition (adjusted R 2 = 0.72) and by C‐READ maximum reading speed and critical print size under the uncorrected near‐vision condition (adjusted R 2 = 0.69). Conclusions: The three C‐READ charts are very comparable to each other, and there is no significant order effect. Reading test results can accurately predict continuous text reading performance quantified by the IReST reading speed over a wide range of refractive errors. The C‐READ is a reliable and valid clinical instrument for quantifying reading performance in simplified Chinese readers.