Samadhan B. Patil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Samadhan B. Patil has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Joao Pedro Conde
Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN), Lisbon, Portugal; Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
7 shared publications - Virginia Chu
Instituto de Engenharia de Sistemas e Computadores–Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol, 1000-029 Lisbon, Portugal
7 shared publications - Valipe Ramgopal Rao
Department of Electrical Engineering, IIT Bombay, Mumbai, India
4 shared publications Manuel Vögtli
UCL, London Ctr Nanotechnol, 17-19 Gordon St, London WC1H 0AH, England
3 shared publications- Rachel A. McKendry
London Centre for Nanotechnology and Division of Medicine, University College London, London, UK
3 shared publications Alka Kumbhar
2 shared publications
Latest Publications
- Open Access
- 1 December 2018
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 122, 88-94
An integrated portable system for single chip simultaneous measurement of multiple disease associated metabolites
- 1 December 2018
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 122, 88-94
Open AccessAn integrated portable system for single chip simultaneous measurement of multiple disease associated metabolites
- Open Access
- 23 March 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep43980
Correction: Corrigendum: Surface mediated cooperative interactions of drugs enhance mechanical forces for antibiotic action
Scientific Reports 7:Article number: 41206; published online: 03 February 2017; updated: 23 March 2017 This Article contains errors. An additional affiliation for Samadhan B. Patil was omitted. The correct affiliations for this Author are listed below: Departments of Medicine, UCL Institute for Liver and Digestive Health, Royal Free Hospital, London NW3 2QG, UK.
- 23 March 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep43980
Open AccessCorrection: Corrigendum: Surface mediated cooperative interactions of drugs enhance mechanical forces for antibiotic action
Scientific Reports 7:Article number: 41206; published online: 03 February 2017; updated: 23 March 2017 This Article contains errors. An additional affiliation for Samadhan B. Patil was omitted. The correct affiliations for this Author are listed below: Departments of Medicine, UCL Institute for Liver and Digestive Health, Royal Free Hospital, London NW3 2QG, UK.
- Open Access
- 3 February 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep41206
Surface mediated cooperative interactions of drugs enhance mechanical forces for antibiotic action
The alarming increase of pathogenic bacteria that are resistant to multiple antibiotics is now recognized as a major health issue fuelling demand for new drugs. Bacterial resistance is often caused by molecular changes at the bacterial surface, which alter the nature of specific drug-target interactions. Here, we identify a novel mechanism by which drug-target interactions in resistant bacteria can be enhanced. We examined the surface forces generated by four antibiotics; vancomycin, ristomycin, chloroeremomycin and oritavancin against drug-susceptible and drug-resistant targets on a cantilever and demonstrated significant differences in mechanical response when drug-resistant targets are challenged with different antibiotics although no significant differences were observed when using susceptible targets. Remarkably, the binding affinity for oritavancin against drug-resistant targets (70 nM) was found to be 11,000 times stronger than for vancomycin (800 μM), a powerful antibiotic used as the last resort treatment for streptococcal and staphylococcal bacteria including methicillin-resistant Staphylococcus aureus (MRSA). Using an exactly solvable model, which takes into account the solvent and membrane effects, we demonstrate that drug-target interactions are strengthened by pronounced polyvalent interactions catalyzed by the surface itself. These findings further enhance our understanding of antibiotic mode of action and will enable development of more effective therapies.
- 3 February 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep41206
Open AccessSurface mediated cooperative interactions of drugs enhance mechanical forces for antibiotic action
The alarming increase of pathogenic bacteria that are resistant to multiple antibiotics is now recognized as a major health issue fuelling demand for new drugs. Bacterial resistance is often caused by molecular changes at the bacterial surface, which alter the nature of specific drug-target interactions. Here, we identify a novel mechanism by which drug-target interactions in resistant bacteria can be enhanced. We examined the surface forces generated by four antibiotics; vancomycin, ristomycin, chloroeremomycin and oritavancin against drug-susceptible and drug-resistant targets on a cantilever and demonstrated significant differences in mechanical response when drug-resistant targets are challenged with different antibiotics although no significant differences were observed when using susceptible targets. Remarkably, the binding affinity for oritavancin against drug-resistant targets (70 nM) was found to be 11,000 times stronger than for vancomycin (800 μM), a powerful antibiotic used as the last resort treatment for streptococcal and staphylococcal bacteria including methicillin-resistant Staphylococcus aureus (MRSA). Using an exactly solvable model, which takes into account the solvent and membrane effects, we demonstrate that drug-target interactions are strengthened by pronounced polyvalent interactions catalyzed by the surface itself. These findings further enhance our understanding of antibiotic mode of action and will enable development of more effective therapies.
- 17 August 2015
- Published by Springer Nature in Nature Nanotechnology
- Vol. 10 (10) , 899-907
Decoupling competing surface binding kinetics and reconfiguration of receptor footprint for ultrasensitive stress assays
Cantilever arrays have been used to monitor biochemical interactions and their associated stress. However, it is often necessary to passivate the underside of the cantilever to prevent unwanted ligand adsorption, and this process requires tedious optimization. Here, we show a way to immobilize membrane receptors on nanomechanical cantilevers so that they can function without passivating the underlying surface. Using equilibrium theory, we quantitatively describe the mechanical responses of vancomycin, human immunodeficiency virus type 1 antigens and coagulation factor VIII captured on the cantilever in the presence of competing stresses from the top and bottom cantilever surfaces. We show that the area per receptor molecule on the cantilever surface influences ligand-receptor binding and plays an important role on stress. Our results offer a new way to sense biomolecules and will aid in the creation of ultrasensitive biosensors.
- 17 August 2015
- Published by Springer Nature in Nature Nanotechnology
- Vol. 10 (10) , 899-907
Decoupling competing surface binding kinetics and reconfiguration of receptor footprint for ultrasensitive stress assays
Cantilever arrays have been used to monitor biochemical interactions and their associated stress. However, it is often necessary to passivate the underside of the cantilever to prevent unwanted ligand adsorption, and this process requires tedious optimization. Here, we show a way to immobilize membrane receptors on nanomechanical cantilevers so that they can function without passivating the underlying surface. Using equilibrium theory, we quantitatively describe the mechanical responses of vancomycin, human immunodeficiency virus type 1 antigens and coagulation factor VIII captured on the cantilever in the presence of competing stresses from the top and bottom cantilever surfaces. We show that the area per receptor molecule on the cantilever surface influences ligand-receptor binding and plays an important role on stress. Our results offer a new way to sense biomolecules and will aid in the creation of ultrasensitive biosensors.
- 9 March 2015
- Published by IOP Publishing in Nanotechnology
- Vol. 26 (13) , 135701
Quantitative sub-surface and non-contact imaging using scanning microwave microscopy
The capability of scanning microwave microscopy for calibrated sub-surface and non-contact capacitance imaging of silicon (Si) samples is quantitatively studied at broadband frequencies ranging from 1 to 20 GHz. Calibrated capacitance images of flat Si test samples with varying dopant density (10 15 –10 19 atoms cm −3 ) and covered with dielectric thin films of SiO 2 (100–400 nm thickness) are measured to demonstrate the sensitivity of scanning microwave microscopy (SMM) for sub-surface imaging. Using standard SMM imaging conditions the dopant areas could still be sensed under a 400 nm thick oxide layer. Non-contact SMM imaging in lift-mode and constant height mode is quantitatively demonstrated on a 50 nm thick SiO 2 test pad. The differences between non-contact and contact mode capacitances are studied with respect to the main parameters influencing the imaging contrast, namely the probe tip diameter and the tip–sample distance. Finite element modelling was used to further analyse the influence of the tip radius and the tip–sample distance on the SMM sensitivity. The understanding of how the two key parameters determine the SMM sensitivity and quantitative capacitances represents an important step towards its routine application for non-contact and sub-surface imaging.
- 9 March 2015
- Published by IOP Publishing in Nanotechnology
- Vol. 26 (13) , 135701
Quantitative sub-surface and non-contact imaging using scanning microwave microscopy
The capability of scanning microwave microscopy for calibrated sub-surface and non-contact capacitance imaging of silicon (Si) samples is quantitatively studied at broadband frequencies ranging from 1 to 20 GHz. Calibrated capacitance images of flat Si test samples with varying dopant density (10 15 –10 19 atoms cm −3 ) and covered with dielectric thin films of SiO 2 (100–400 nm thickness) are measured to demonstrate the sensitivity of scanning microwave microscopy (SMM) for sub-surface imaging. Using standard SMM imaging conditions the dopant areas could still be sensed under a 400 nm thick oxide layer. Non-contact SMM imaging in lift-mode and constant height mode is quantitatively demonstrated on a 50 nm thick SiO 2 test pad. The differences between non-contact and contact mode capacitances are studied with respect to the main parameters influencing the imaging contrast, namely the probe tip diameter and the tip–sample distance. Finite element modelling was used to further analyse the influence of the tip radius and the tip–sample distance on the SMM sensitivity. The understanding of how the two key parameters determine the SMM sensitivity and quantitative capacitances represents an important step towards its routine application for non-contact and sub-surface imaging.
- 21 February 2012
- Published by IOP Publishing in Applied Physics Express
- Vol. 5 (3)
Strong Temperature Dependence of Extraordinary Magnetoresistance Correlated to Mobility in a Two-Contact Device
A two-contact extraordinary magnetoresistance (EMR) device has been fabricated and characterized at various temperatures under magnetic fields applied in different directions. Large performance variations across the temperature range have been found, which are due to the strong dependence of the EMR effect on the mobility. The device shows the highest sensitivity of 562ω/T at 75 K with the field applied perpendicularly. Due to the overlap between the semiconductor and the metal shunt, the device is also sensitive to planar fields but with a lower sensitivity of about 20 to 25% of the one to perpendicular fields. © 2012 The Japan Society of Applied Physics
- 21 February 2012
- Published by IOP Publishing in Applied Physics Express
- Vol. 5 (3)
Strong Temperature Dependence of Extraordinary Magnetoresistance Correlated to Mobility in a Two-Contact Device
A two-contact extraordinary magnetoresistance (EMR) device has been fabricated and characterized at various temperatures under magnetic fields applied in different directions. Large performance variations across the temperature range have been found, which are due to the strong dependence of the EMR effect on the mobility. The device shows the highest sensitivity of 562ω/T at 75 K with the field applied perpendicularly. Due to the overlap between the semiconductor and the metal shunt, the device is also sensitive to planar fields but with a lower sensitivity of about 20 to 25% of the one to perpendicular fields. © 2012 The Japan Society of Applied Physics
- Open Access
- 30 September 2009
- Published by Elsevier in Procedia Chemistry
- Vol. 1 (1) , 1063-1066
Mass Sensing using an Amorphous Silicon MEMS resonator
- 30 September 2009
- Published by Elsevier in Procedia Chemistry
- Vol. 1 (1) , 1063-1066
Open AccessMass Sensing using an Amorphous Silicon MEMS resonator
- 13 July 2009
- Published by AIP Publishing in Applied Physics Letters
- Vol. 95 (2) , 023502
On-chip magnetoresistive detection of resonance in microcantilevers
Magnetoresistive spin-valve sensors were used to provide on-chip detection of the mechanical resonance of a thin silicon microelectromechanical systems cantilever. The spin-valve sensor was placed underneath the free end of the cantilever. A CoCrPt thin-film permanent magnet was placed on top of the amorphous silicon/Al cantilever. The cantilever was electrostatically actuated and its deflection creates a change in the magnetic field that can be sensed by the spin-valve sensor. The resonance frequency of the structure in the megahertz range is detected by the measurement of the spin-valve sensor output. Minimum deflection detection limit is determined to be .- 13 July 2009
- Published by AIP Publishing in Applied Physics Letters
- Vol. 95 (2) , 023502
On-chip magnetoresistive detection of resonance in microcantilevers
Magnetoresistive spin-valve sensors were used to provide on-chip detection of the mechanical resonance of a thin silicon microelectromechanical systems cantilever. The spin-valve sensor was placed underneath the free end of the cantilever. A CoCrPt thin-film permanent magnet was placed on top of the amorphous silicon/Al cantilever. The cantilever was electrostatically actuated and its deflection creates a change in the magnetic field that can be sensed by the spin-valve sensor. The resonance frequency of the structure in the megahertz range is detected by the measurement of the spin-valve sensor output. Minimum deflection detection limit is determined to be .- 20 January 2009
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 19 (2)
Comparison of the mechanical and resonance properties of thin film silicon MEMS fabricated at 110 and 250 °C
- 20 January 2009
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 19 (2)
Comparison of the mechanical and resonance properties of thin film silicon MEMS fabricated at 110 and 250 °C