Kranthi Kumar Kolli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kranthi Kumar Kolli has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Rupak Kumar Banerjee
Department of Biomedical Engineering, University of Cincinnati, Veterans Affairs Medical Center, Cincinnati, OH, USA
23 shared publications Srikara V. Peelukhana
Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH 45221, USA; Veteran Affairs Medical Center, Cincinnati, OH, USA
14 shared publicationsImran Arif
13 shared publicationsMohamed Effat
Division of Cardiovascular Diseases, University of Cincinnati, Cincinnati, OH 45221, USA; Veteran Affairs Medical Center, Cincinnati, OH, USA
12 shared publicationsPaul Succop
Department of Environmental Health, University of Cincinnati, Cincinnati, OH 45221, USA
10 shared publicationsLloyd H. Back
California Institute of Technology
8 shared publications
Latest Publications
- Open Access
- 5 December 2022
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 2 (2)
Association Between Intracoronary Imaging During PCI and Clinical Outcomes in a Real-World US Medicare Population
- 5 December 2022
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 2 (2)
Open AccessAssociation Between Intracoronary Imaging During PCI and Clinical Outcomes in a Real-World US Medicare Population
- Open Access
- 11 November 2022
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 4 (1) , 43-52
Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity
Remote monitoring (RM) is the standard of care for follow up of patients with cardiac implantable electronic devices. The aim of this study was to compare smartphone-based RM (SM-RM) using patient applications (myMerlinPulseTM app) with traditional bedside monitor RM (BM-RM). The retrospective study included de-identified U.S. patients who received either SM-RM or BM-RM capable implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators (Abbott, USA). Patients in SM-RM and BM-RM groups were propensity-score matched on age and gender, device type, implant year and month. Compliance with RM was quantified as the proportion of patients enrolling in the RM system (Merlin.netTM) and transmitting data at least once. Connectivity was measured by the median number of days between consecutive transmissions per patient. Of the initial 9,714 patients with SM-RM and 26,679 patients with BM-RM, 9,397 patients from each group were matched. RM compliance was higher in SM-RM; significantly more patients with SM-RM were enrolled in RM compared to BM-RM (94.4% vs. 85.0%, p < 0.001), similar number of patients in the SM-RM group paired their device (95.1% vs. 95.0%, p = 0.77), but more SM-RM patients transmitted at least once (98.1% vs. 94.3%, p < 0.001). Connectivity was significantly higher in the SM-RM, with patients transmitting data every 1.2 [1.1, 1.7] vs. every 1.7 [1.5, 2.0] days with BM-RM (p < 0.001) and remained better over time. Significantly more SM-RM patients utilized patient-initiated transmissions compared to BM-RM (55.6% vs. 28.1%, p < 0.001). In this large real-world study, patients with SM-RM demonstrated improved compliance and connectivity compared to BM-RM.
- 11 November 2022
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 4 (1) , 43-52
Open AccessSmartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity
Remote monitoring (RM) is the standard of care for follow up of patients with cardiac implantable electronic devices. The aim of this study was to compare smartphone-based RM (SM-RM) using patient applications (myMerlinPulseTM app) with traditional bedside monitor RM (BM-RM). The retrospective study included de-identified U.S. patients who received either SM-RM or BM-RM capable implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators (Abbott, USA). Patients in SM-RM and BM-RM groups were propensity-score matched on age and gender, device type, implant year and month. Compliance with RM was quantified as the proportion of patients enrolling in the RM system (Merlin.netTM) and transmitting data at least once. Connectivity was measured by the median number of days between consecutive transmissions per patient. Of the initial 9,714 patients with SM-RM and 26,679 patients with BM-RM, 9,397 patients from each group were matched. RM compliance was higher in SM-RM; significantly more patients with SM-RM were enrolled in RM compared to BM-RM (94.4% vs. 85.0%, p < 0.001), similar number of patients in the SM-RM group paired their device (95.1% vs. 95.0%, p = 0.77), but more SM-RM patients transmitted at least once (98.1% vs. 94.3%, p < 0.001). Connectivity was significantly higher in the SM-RM, with patients transmitting data every 1.2 [1.1, 1.7] vs. every 1.7 [1.5, 2.0] days with BM-RM (p < 0.001) and remained better over time. Significantly more SM-RM patients utilized patient-initiated transmissions compared to BM-RM (55.6% vs. 28.1%, p < 0.001). In this large real-world study, patients with SM-RM demonstrated improved compliance and connectivity compared to BM-RM.
- 1 April 2018
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 19 (3) , 348-354
Evaluation of lesion flow coefficient for the detection of coronary artery disease in patient groups from two academic medical centers
- 1 April 2018
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 19 (3) , 348-354
Evaluation of lesion flow coefficient for the detection of coronary artery disease in patient groups from two academic medical centers
- Open Access
- 1 December 2016
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 5 (12)
Relationship Between Endothelial Wall Shear Stress and High‐Risk Atherosclerotic Plaque Characteristics for Identification of Coronary Lesions That Cause Ischemia: A Direct Comparison With Fractional Flow Reserve
Background: Wall shear stress ( WSS ) is an established predictor of coronary atherosclerosis progression. Prior studies have reported that high WSS has been associated with high‐risk atherosclerotic plaque characteristics ( APC s). WSS and APC s are quantifiable by coronary computed tomography angiography, but the relationship of coronary lesion ischemia—evaluated by fractional flow reserve—to WSS and APC s has not been examined. Methods and Results: WSS measures were obtained from 100 evaluable patients who underwent coronary computed tomography angiography and invasive coronary angiography with fractional flow reserve. Patients were categorized according to tertiles of mean WSS values defined as low, intermediate, and high. Coronary ischemia was defined as fractional flow reserve ≤0.80. Stenosis severity was determined by minimal luminal diameter. APC s were defined as positive remodeling, low attenuation plaque, and spotty calcification. The likelihood of having positive remodeling and low‐attenuation plaque was greater in the high WSS group compared with the low WSS group after adjusting for minimal luminal diameter (odds ratio for positive remodeling: 2.54, 95% CI 1.12–5.77; odds ratio for low‐attenuation plaque: 2.68, 95% CI 1.02–7.06; both P P =0.30 for difference). Conclusions: High WSS is associated with APC s independent of stenosis severity. WSS provided no added value beyond stenosis severity and APC s for detecting lesions with significant ischemia.
- 1 December 2016
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 5 (12)
Open AccessRelationship Between Endothelial Wall Shear Stress and High‐Risk Atherosclerotic Plaque Characteristics for Identification of Coronary Lesions That Cause Ischemia: A Direct Comparison With Fractional Flow Reserve
Background: Wall shear stress ( WSS ) is an established predictor of coronary atherosclerosis progression. Prior studies have reported that high WSS has been associated with high‐risk atherosclerotic plaque characteristics ( APC s). WSS and APC s are quantifiable by coronary computed tomography angiography, but the relationship of coronary lesion ischemia—evaluated by fractional flow reserve—to WSS and APC s has not been examined. Methods and Results: WSS measures were obtained from 100 evaluable patients who underwent coronary computed tomography angiography and invasive coronary angiography with fractional flow reserve. Patients were categorized according to tertiles of mean WSS values defined as low, intermediate, and high. Coronary ischemia was defined as fractional flow reserve ≤0.80. Stenosis severity was determined by minimal luminal diameter. APC s were defined as positive remodeling, low attenuation plaque, and spotty calcification. The likelihood of having positive remodeling and low‐attenuation plaque was greater in the high WSS group compared with the low WSS group after adjusting for minimal luminal diameter (odds ratio for positive remodeling: 2.54, 95% CI 1.12–5.77; odds ratio for low‐attenuation plaque: 2.68, 95% CI 1.02–7.06; both P P =0.30 for difference). Conclusions: High WSS is associated with APC s independent of stenosis severity. WSS provided no added value beyond stenosis severity and APC s for detecting lesions with significant ischemia.
- 1 October 2015
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 87 (2) , 273-282
Diagnostic cutoff for pressure drop coefficient in relation to fractional flow reserve and coronary flow reserve: A Patient‐Level Analysis
Functional assessment of intermediate coronary stenosis during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR), coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR), and hyperemic microvascular resistance (HMR). CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a nondimensional index derived from fundamental fluid dynamic principles, based on a combination of intracoronary pressure, and flow measurements may improve the functional assessment of coronary lesion severity. Patient-level data pertaining to 350 intracoronary pressure and flow measurements across coronary stenoses was assessed to evaluate CFR, FFR, HSR, HMR, and CDP. CDP was calculated as (ΔP)/(0.5 × ρ × APV2). The density of blood (ρ) was assumed to be 1.05 g/cm3. The correlation of current diagnostic parameters (CFR, FFR, HSR, and HMR) with CDP was evaluated. The receiver operating characteristic (ROC) curve was used to identify the optimal cut-off point of CDP, corresponding to the clinically used cut-off values (FFR = 0.80 and CFR = 2.0). CDP correlated significantly with FFR (r = 0.81, P < 0.05) and had significant diagnostic efficiency (ROC-area under curve of 86%), specificity (72%) and sensitivity (85%) at FFR < 0.8. The corresponding cut-off value for CDP to detect FFR < 0.8 was at CDP>25.4. CDP also correlated significantly (r = 0.98, P < 0.05) with epicardial-specific parameter, HSR. CDP, a functional parameter based on both intracoronary pressure and flow measurements, has close agreement (area under ROC curve = 86%) with FFR, the frequently used method of evaluating stenosis severity.
- 1 October 2015
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 87 (2) , 273-282
Diagnostic cutoff for pressure drop coefficient in relation to fractional flow reserve and coronary flow reserve: A Patient‐Level Analysis
Functional assessment of intermediate coronary stenosis during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR), coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR), and hyperemic microvascular resistance (HMR). CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a nondimensional index derived from fundamental fluid dynamic principles, based on a combination of intracoronary pressure, and flow measurements may improve the functional assessment of coronary lesion severity. Patient-level data pertaining to 350 intracoronary pressure and flow measurements across coronary stenoses was assessed to evaluate CFR, FFR, HSR, HMR, and CDP. CDP was calculated as (ΔP)/(0.5 × ρ × APV2). The density of blood (ρ) was assumed to be 1.05 g/cm3. The correlation of current diagnostic parameters (CFR, FFR, HSR, and HMR) with CDP was evaluated. The receiver operating characteristic (ROC) curve was used to identify the optimal cut-off point of CDP, corresponding to the clinically used cut-off values (FFR = 0.80 and CFR = 2.0). CDP correlated significantly with FFR (r = 0.81, P < 0.05) and had significant diagnostic efficiency (ROC-area under curve of 86%), specificity (72%) and sensitivity (85%) at FFR < 0.8. The corresponding cut-off value for CDP to detect FFR < 0.8 was at CDP>25.4. CDP also correlated significantly (r = 0.98, P < 0.05) with epicardial-specific parameter, HSR. CDP, a functional parameter based on both intracoronary pressure and flow measurements, has close agreement (area under ROC curve = 86%) with FFR, the frequently used method of evaluating stenosis severity.
- 1 October 2015
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 36 (10) , 986-998
Benefit of ECG-gated rest and stress N-13 cardiac PET imaging for quantification of LVEF in ischemic patients
Background ECG-gated rest–stress cardiac PET can lead to simultaneous quantification of both left ventricular ejection fraction and flow impairment. In this study, our aim was to assess the benefit of rest and stress PET ejection fraction (EF) (EFp) in relation to single-photon emission computed tomography (SPECT) EF (EFs) and echocardiography EF (EFe). To this effect, the EFp was compared with EFs and EFe. Further, the relation between rest and stress EFp was also assessed. Methods ECG-gated N-13 ammonia rest and stress PET imaging was performed in 26 patients. EFp values were obtained using gated reconstruction of the data in Flowquant. In 13 patients, EFs and EFe values were obtained through chart review. Correlation, analysis of variance, and Bland–Altman analyses were performed. P values less than 0.05 were used for statistical significance. Results The rest and stress EFp values correlated significantly (r=0.80 and 0.71, respectively; Ps values. There was moderate correlation with statistical significance (Pp and EFe values (r=0.58 and 0.50, respectively). The mean rest and stress EFp values were not significantly different from mean EFs values. Also, the rest EFp and stress EFp values correlated well (r=0.81, Pp, and EFs, and EFe values. Conclusion Rest and stress EFp values obtained through an ECG-gated PET scan can be used for clinical diagnosis in place of conventional methods like SPECT and echocardiography.
- 1 October 2015
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 36 (10) , 986-998
Benefit of ECG-gated rest and stress N-13 cardiac PET imaging for quantification of LVEF in ischemic patients
Background ECG-gated rest–stress cardiac PET can lead to simultaneous quantification of both left ventricular ejection fraction and flow impairment. In this study, our aim was to assess the benefit of rest and stress PET ejection fraction (EF) (EFp) in relation to single-photon emission computed tomography (SPECT) EF (EFs) and echocardiography EF (EFe). To this effect, the EFp was compared with EFs and EFe. Further, the relation between rest and stress EFp was also assessed. Methods ECG-gated N-13 ammonia rest and stress PET imaging was performed in 26 patients. EFp values were obtained using gated reconstruction of the data in Flowquant. In 13 patients, EFs and EFe values were obtained through chart review. Correlation, analysis of variance, and Bland–Altman analyses were performed. P values less than 0.05 were used for statistical significance. Results The rest and stress EFp values correlated significantly (r=0.80 and 0.71, respectively; Ps values. There was moderate correlation with statistical significance (Pp and EFe values (r=0.58 and 0.50, respectively). The mean rest and stress EFp values were not significantly different from mean EFs values. Also, the rest EFp and stress EFp values correlated well (r=0.81, Pp, and EFs, and EFe values. Conclusion Rest and stress EFp values obtained through an ECG-gated PET scan can be used for clinical diagnosis in place of conventional methods like SPECT and echocardiography.
- 1 January 2015
- Vol. 27 (1) , 54-64
Lesion flow coefficient: a combined anatomical and functional parameter for detection of coronary artery disease--a clinical study.
Invasive diagnosis of coronary artery disease utilizes either anatomical or functional measurements. In this study, we tested a futuristic parameter, lesion flow coefficient (LFC, defined as the ratio of percent coronary area stenosis (%AS) to the square root of the ratio of the pressure drop across the stenosis to the dynamic pressure in the throat region), that combines both the anatomical (%AS) and functional measurements (pressure and flow) for application in a clinical setting. In 51 vessels, simultaneous pressure and flow readings were obtained using a 0.014" Combowire (Volcano Corporation). Anatomical details were assessed using quantitative coronary angiography (QCA). Fractional flow reserve (FFR), coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR), and hyperemic microvascular index (HMR) were obtained at baseline and adenosine-induced hyperemia. QCA data were corrected for the presence of guidewire and then the LFC values were calculated. LFC was correlated with FFR, CFR, HSR, and HMR, individually and in combination with %AS, under both baseline and hyperemic conditions. Further, in 5 vessels, LFC group mean values were compared between pre-PCI and post-PCI groups. P<.05 was considered statistically significant. LFC measured at hyperemia correlated significantly when the pressure-based FFR, flow-based CFR, and anatomically measured %AS were combined (r = 0.64; P<.05). Similarly, LFC correlated significantly when HSR, HMR, and %AS were combined (r = 0.72; P<.05). LFC was able to significantly distinguish between pre-PCI and post-PCI groups (0.42 ± 0.05 and 0.05 ± 0.004, respectively; P<.05). Similar results were obtained for the LFC at baseline conditions. LFC, a futuristic parameter that combines both the anatomical and functional endpoints, has potential for application in a clinical setting for stenosis evaluation, under both hyperemic and baseline conditions.
- 1 January 2015
- Vol. 27 (1) , 54-64
Lesion flow coefficient: a combined anatomical and functional parameter for detection of coronary artery disease--a clinical study.
Invasive diagnosis of coronary artery disease utilizes either anatomical or functional measurements. In this study, we tested a futuristic parameter, lesion flow coefficient (LFC, defined as the ratio of percent coronary area stenosis (%AS) to the square root of the ratio of the pressure drop across the stenosis to the dynamic pressure in the throat region), that combines both the anatomical (%AS) and functional measurements (pressure and flow) for application in a clinical setting. In 51 vessels, simultaneous pressure and flow readings were obtained using a 0.014" Combowire (Volcano Corporation). Anatomical details were assessed using quantitative coronary angiography (QCA). Fractional flow reserve (FFR), coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR), and hyperemic microvascular index (HMR) were obtained at baseline and adenosine-induced hyperemia. QCA data were corrected for the presence of guidewire and then the LFC values were calculated. LFC was correlated with FFR, CFR, HSR, and HMR, individually and in combination with %AS, under both baseline and hyperemic conditions. Further, in 5 vessels, LFC group mean values were compared between pre-PCI and post-PCI groups. P<.05 was considered statistically significant. LFC measured at hyperemia correlated significantly when the pressure-based FFR, flow-based CFR, and anatomically measured %AS were combined (r = 0.64; P<.05). Similarly, LFC correlated significantly when HSR, HMR, and %AS were combined (r = 0.72; P<.05). LFC was able to significantly distinguish between pre-PCI and post-PCI groups (0.42 ± 0.05 and 0.05 ± 0.004, respectively; P<.05). Similar results were obtained for the LFC at baseline conditions. LFC, a futuristic parameter that combines both the anatomical and functional endpoints, has potential for application in a clinical setting for stenosis evaluation, under both hyperemic and baseline conditions.
- 21 June 2014
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 28 (8) , 746-760
Benefit of cardiac N-13 PET CFR for combined anatomical and functional diagnosis of ischemic coronary artery disease: a pilot study
Cardiac positron emission tomography (PET) can lead to flow impairment quantification using PET coronary flow reserve (CFRp: ratio of stress flow to rest flow) and is superior to the current standard, single-photon emission computed tomography. In this study, our first aim was to assess the benefit of CFRp in place of invasive CFR (CFRi) by comparing the correlations of each of the indices with combined pressure and flow index CDP, and combined functional (pressure-flow) and anatomical (%area stenosis, %AS) index, LFC. The second aim was to test the correlation between CFRp and CFRi. N-13 ammonia PET scans were performed and CFRp was obtained using a 1-compartment 2K-dynamic volume (DV)-constant kinetic model in Flowquant. During catheterization, simultaneous pressure and flow readings were obtained in 10 vessels (three vessels in one patient, one vessel each in 7 patients) using a dual sensor tipped Combowire, and CFRi, CDP, LFC, and FFR were computed. %AS was obtained using quantitative coronary angiography. CDP was correlated with invasive pressure index (FFR) and CFRp and with FFR and CFRi. LFC was correlated with the %AS, FFR, and CFRp/CFRi, individually and in combination. Correlation analysis was done in SAS; p < 0.05 was used for statistical significance. The correlations between CDP vs FFR and CFRp (r = 0.62, p = 0.19) in combination, as well as CDP vs FFR and CFRi in combination (r = 0.58, p = 0.24) remained similar. The correlation between LFC vs FFR, CFRp and %AS in combination improved (r = 0.82) with a near-significant p = 0.06, in comparison to the correlation between LFC vs FFR, CFRi and %AS in combination (r = 0.75, p = 0.15). CFRp correlated strongly and significantly (r = 0.82, p = 0.003) with CFRi, and the values were within 11 %. The novelty of the PET procedure in this study is that the noninvasive CFRp can be used instead of invasive CFRi for the functional diagnosis of CAD. Therefore, a PET scan can reduce procedure time and cost while simplifying the diagnostic protocol for assessing coronary artery disease, thus benefitting both the patients and clinicians.
- 21 June 2014
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 28 (8) , 746-760
Benefit of cardiac N-13 PET CFR for combined anatomical and functional diagnosis of ischemic coronary artery disease: a pilot study
Cardiac positron emission tomography (PET) can lead to flow impairment quantification using PET coronary flow reserve (CFRp: ratio of stress flow to rest flow) and is superior to the current standard, single-photon emission computed tomography. In this study, our first aim was to assess the benefit of CFRp in place of invasive CFR (CFRi) by comparing the correlations of each of the indices with combined pressure and flow index CDP, and combined functional (pressure-flow) and anatomical (%area stenosis, %AS) index, LFC. The second aim was to test the correlation between CFRp and CFRi. N-13 ammonia PET scans were performed and CFRp was obtained using a 1-compartment 2K-dynamic volume (DV)-constant kinetic model in Flowquant. During catheterization, simultaneous pressure and flow readings were obtained in 10 vessels (three vessels in one patient, one vessel each in 7 patients) using a dual sensor tipped Combowire, and CFRi, CDP, LFC, and FFR were computed. %AS was obtained using quantitative coronary angiography. CDP was correlated with invasive pressure index (FFR) and CFRp and with FFR and CFRi. LFC was correlated with the %AS, FFR, and CFRp/CFRi, individually and in combination. Correlation analysis was done in SAS; p < 0.05 was used for statistical significance. The correlations between CDP vs FFR and CFRp (r = 0.62, p = 0.19) in combination, as well as CDP vs FFR and CFRi in combination (r = 0.58, p = 0.24) remained similar. The correlation between LFC vs FFR, CFRp and %AS in combination improved (r = 0.82) with a near-significant p = 0.06, in comparison to the correlation between LFC vs FFR, CFRi and %AS in combination (r = 0.75, p = 0.15). CFRp correlated strongly and significantly (r = 0.82, p = 0.003) with CFRi, and the values were within 11 %. The novelty of the PET procedure in this study is that the noninvasive CFRp can be used instead of invasive CFRi for the functional diagnosis of CAD. Therefore, a PET scan can reduce procedure time and cost while simplifying the diagnostic protocol for assessing coronary artery disease, thus benefitting both the patients and clinicians.
- 8 May 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (8) , 1681-1690
Hyperemia-Free Delineation of Epicardial and Microvascular Impairments Using a Basal Index
The assessment of functional coronary lesion severity using intracoronary hemodynamic parameters like the pressure-derived fractional flow reserve and the flow-derived coronary flow reserve are known to rely critically on the establishment of maximal hyperemia. We evaluated a hyperemia-free index, basal pressure drop coefficient (bCDP), that combines pressure and velocity for simultaneous assessment of the status of both epicardial and microvascular circulations. In 23 pigs, simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual-sensor tipped guidewire in the settings of both normal and abnormal microcirculation with the presence of epicardial lesions of area stenosis (AS) < 50% and AS > 50%. The bCDP, a parameter based on fundamental fluid dynamics principles, was calculated as the transtenotic pressure-drop divided by the dynamic pressure in the distal vessel, measured under baseline (without hyperemia) conditions. The group mean values of bCDP for normal (84 ± 18) and abnormal (124.5 ± 15.6) microcirculation were significantly different. Similarly, the mean values of bCDP from AS < 50% (72.5 ± 16.1) and AS > 50% (136 ± 17.2) were also significantly different (p < 0.05). The bCDP could significantly distinguish between lesions of AS < 50% to AS > 50% under normal microcirculation (52.1 vs. 85.8; p < 0.05) and abnormal microcirculation (84.9 vs. 172; p < 0.05). Further, the bCDP correlated linearly and significantly with the hyperemic parameters FFR (r = 0.42, p < 0.05) and CDP (r = 0.50, p < 0.05). The bCDP is a promising clinical diagnostic parameter that can independently assess the severity of epicardial stenosis and microvascular impairment. We believe that it has an immediate appeal for detection of coronary artery disease if validated clinically.
- 8 May 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (8) , 1681-1690
Hyperemia-Free Delineation of Epicardial and Microvascular Impairments Using a Basal Index
The assessment of functional coronary lesion severity using intracoronary hemodynamic parameters like the pressure-derived fractional flow reserve and the flow-derived coronary flow reserve are known to rely critically on the establishment of maximal hyperemia. We evaluated a hyperemia-free index, basal pressure drop coefficient (bCDP), that combines pressure and velocity for simultaneous assessment of the status of both epicardial and microvascular circulations. In 23 pigs, simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual-sensor tipped guidewire in the settings of both normal and abnormal microcirculation with the presence of epicardial lesions of area stenosis (AS) < 50% and AS > 50%. The bCDP, a parameter based on fundamental fluid dynamics principles, was calculated as the transtenotic pressure-drop divided by the dynamic pressure in the distal vessel, measured under baseline (without hyperemia) conditions. The group mean values of bCDP for normal (84 ± 18) and abnormal (124.5 ± 15.6) microcirculation were significantly different. Similarly, the mean values of bCDP from AS < 50% (72.5 ± 16.1) and AS > 50% (136 ± 17.2) were also significantly different (p < 0.05). The bCDP could significantly distinguish between lesions of AS < 50% to AS > 50% under normal microcirculation (52.1 vs. 85.8; p < 0.05) and abnormal microcirculation (84.9 vs. 172; p < 0.05). Further, the bCDP correlated linearly and significantly with the hyperemic parameters FFR (r = 0.42, p < 0.05) and CDP (r = 0.50, p < 0.05). The bCDP is a promising clinical diagnostic parameter that can independently assess the severity of epicardial stenosis and microvascular impairment. We believe that it has an immediate appeal for detection of coronary artery disease if validated clinically.
- 1 May 2014
- Vol. 26 (5) , 188-195
Diagnostic Performance of Pressure Drop Coefficient in Relation to Fractional Flow Reserve and Coronary Flow Reserve
Objectives and Background. Functional assessment of coronary lesion severity during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR; pressure derived) and coronary flow reserve (CFR; flow derived). However, the complex hemodynamics of stenosis might not be sufficiently explained by either pressure or flow alone, particularly in the case of intermediate stenosis. CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a non-dimensional index derived from fundamental fluid dynamic principles based on a combination of intracoronary pressure and flow, may improve the functional assessment of coronary lesion severity. Methods. We performed a meta-analysis of seven studies, retrieved from MEDLINE and PubMed, comparing the results of FFR and CFR of the same lesions. Two studies reported functional measurements (pressure and flow) obtained in individual patients. Five studies reported two-dimensional plots of FFR vs CFR. The FFR and CFR data were digitized and corresponding funetional measurements were extracted using the reported mean values of hemodynamic data from each of the five studies. The receiver operating characteristic (ROC) curve was used to identify the optimal cut-off point of CDP, which corresponds to the clinically used cut-off values (FFR = 0.80, FFR = 0.75, and CFR = 2.0). Results. CDP correlated significantly with FFR (r = 0.78; P<.001) and had significant diagnostic efficiency (area under the ROC curve = 89%), specificity (83% and 85%), and sensitivity (81% and 76%) at FFR 27.9, respectively. Conclusions. CDP, a functional parameter based on both intracoronary pressure and flow measurements, has close agreement (area under the ROC curve = 89%) with FFR, the most frequently used method for evaluation of coronary stenosis severity.
- 1 May 2014
- Vol. 26 (5) , 188-195
Diagnostic Performance of Pressure Drop Coefficient in Relation to Fractional Flow Reserve and Coronary Flow Reserve
Objectives and Background. Functional assessment of coronary lesion severity during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR; pressure derived) and coronary flow reserve (CFR; flow derived). However, the complex hemodynamics of stenosis might not be sufficiently explained by either pressure or flow alone, particularly in the case of intermediate stenosis. CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a non-dimensional index derived from fundamental fluid dynamic principles based on a combination of intracoronary pressure and flow, may improve the functional assessment of coronary lesion severity. Methods. We performed a meta-analysis of seven studies, retrieved from MEDLINE and PubMed, comparing the results of FFR and CFR of the same lesions. Two studies reported functional measurements (pressure and flow) obtained in individual patients. Five studies reported two-dimensional plots of FFR vs CFR. The FFR and CFR data were digitized and corresponding funetional measurements were extracted using the reported mean values of hemodynamic data from each of the five studies. The receiver operating characteristic (ROC) curve was used to identify the optimal cut-off point of CDP, which corresponds to the clinically used cut-off values (FFR = 0.80, FFR = 0.75, and CFR = 2.0). Results. CDP correlated significantly with FFR (r = 0.78; P<.001) and had significant diagnostic efficiency (area under the ROC curve = 89%), specificity (83% and 85%), and sensitivity (81% and 76%) at FFR 27.9, respectively. Conclusions. CDP, a functional parameter based on both intracoronary pressure and flow measurements, has close agreement (area under the ROC curve = 89%) with FFR, the most frequently used method for evaluation of coronary stenosis severity.