JMJiang Ming

Jiang Ming

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiang Ming has a total of 139 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ce 3+ ‐Mediated Self‐Calibrating NIR‐II Nanothermometer Enables Reliable Real‐Time In Vivo Temperature Monitoring

    by Mingzhu Yang, Zi‐Han Chen, Hongyue Liu, Jing Xu, Jiang Ming, Zhenfeng Yu, Xusheng Wang, Baofeng Yun, Xiaohan Wang, Zhihua Wang, et al.

    Precise temperature monitoring in living systems provides valuable insights into physiological processes, thereby motivating the development of luminescent nanothermometers for noninvasive thermometry. However, wavelength‐dependent tissue absorption and scattering inevitably distort luminescence signals, resulting in inaccurate temperature measurements. Here, we report a self‐calibrating luminescent nanothermometer (NaYF 4 : Tm@NaYF 4 : Er@NaYF 4 @NaYbF 4 : Er/Tm/Ce@NaYF 4 ) that utilizes the Er 3+ and Tm 3+ emissions at 1532 and 1626 nm in the low‐scattering long‐wavelength near‐infrared region (NIR‐II‐L, 1500–1900 nm) to achieve reliable in vivo thermometry. By identifying Ce 3+ as a critical mediator that suppresses temperature‐sensitive phonon‐assisted energy transfer (PAT) between Tm 3+ and Er 3+ , we inversely engineered the Ce 3+ ‐doped Tm 3+ /Er 3+ outer module to generate a thermally inert reference ratio for calibrating the PAT‐enhanced thermometric ratio of the inner Tm 3+ /Er 3+ module. The resulting self‐calibrating signal minimized depth‐induced distortion with only 2.9% fluctuation through 10 mm of tissue, enabling reliable dynamic thermometry at a high temporal resolution of 20 fps. In vivo studies further demonstrated that the nanothermometer enabled accurate intestinal thermometry and intratumoral temperature monitoring during photothermal therapy. This work provides new insights into self‐calibrating luminescent nanoprobes for accurate real‐time sensing in living systems.


  • Ce 3+ ‐Mediated Self‐Calibrating NIR‐II Nanothermometer Enables Reliable Real‐Time In Vivo Temperature Monitoring

    by Mingzhu Yang, Zi‐Han Chen, Hongyue Liu, Jing Xu, Jiang Ming, Zhenfeng Yu, Xusheng Wang, Baofeng Yun, Xiaohan Wang, Zhihua Wang, et al.

    Precise temperature monitoring in living systems provides valuable insights into physiological processes, thereby motivating the development of luminescent nanothermometers for noninvasive thermometry. However, wavelength‐dependent tissue absorption and scattering inevitably distort luminescence signals, resulting in inaccurate temperature measurements. Here, we report a self‐calibrating luminescent nanothermometer (NaYF 4 : Tm@NaYF 4 : Er@NaYF 4 @NaYbF 4 : Er/Tm/Ce@NaYF 4 ) that utilizes the Er 3+ and Tm 3+ emissions at 1532 and 1626 nm in the low‐scattering long‐wavelength near‐infrared region (NIR‐II‐L, 1500–1900 nm) to achieve reliable in vivo thermometry. By identifying Ce 3+ as a critical mediator that suppresses temperature‐sensitive phonon‐assisted energy transfer (PAT) between Tm 3+ and Er 3+ , we inversely engineered the Ce 3+ ‐doped Tm 3+ /Er 3+ outer module to generate a thermally inert reference ratio for calibrating the PAT‐enhanced thermometric ratio of the inner Tm 3+ /Er 3+ module. The resulting self‐calibrating signal minimized depth‐induced distortion with only 2.9% fluctuation through 10 mm of tissue, enabling reliable dynamic thermometry at a high temporal resolution of 20 fps. In vivo studies further demonstrated that the nanothermometer enabled accurate intestinal thermometry and intratumoral temperature monitoring during photothermal therapy. This work provides new insights into self‐calibrating luminescent nanoprobes for accurate real‐time sensing in living systems.


  • Interfacial Cascade Energy Transfer Enhances Lanthanide Luminescence for NIR-II Ratiometric Deep-Tissue Localization

    by Ting Han, Zi-Han Chen, Hongyue Liu, Jiang Ming, Xiaohan Wang, Zhihua Wang, Wenlin Li, Caiyun Fang, Yong Fan, Fan Zhang

    Near-infrared (NIR, 750–2500 nm) imaging is crucial for disease diagnosis, yet conventional wide-field bioimaging yields only two-dimensional (2D) information without depth. Here, we report a ratiometric fluorescence strategy for tissue depth determination using α-NaTmF4@NaErF4@NaYF4 nanoprobes. Under 808 nm excitation, interfacial cascade energy transfer between Tm3+ and Er3+ ions enhances NIR-II emissions at 1532 and 1626 nm by 3.3- and 6.7-fold, respectively, compared with that of a codoped counterpart. Leveraging distinct water absorption at these wavelengths, the logarithm of the attenuated intensity ratio (ITm/IEr) varies linearly with tissue depth (0–4 mm). With this NIR ratiometric wide-field depth-mapping method, quantitative depth information about in vivo vasculature was assigned to each image pixel and rendered into 2.5D visualization by stacking 2D planes over a 40 mm × 40 mm × 4 mm volume. Dynamic tracking of nanoprobe redistribution from vessels along the projection direction was also demonstrated. This work establishes a universal depth-analysis tool and significantly advances medical optical imaging.

  • A New Class of Bond-Length-Engineered Transition-Metal-Doped Nanocrystals with Tunable NIR-II Absorption and Emission

    by Zhixiu Guo, Yaning Shi, Jiang Ming, Zheng Xie, Zi-Han Chen, Hongyue Liu, Mingzhu Yang, Liuyi Yang, Wenlin Li, Yong Fan, et al.

    Developing luminescent probes with tunable absorption and emission in the second near-infrared (NIR-II) or shortwave infrared (SWIR) region (1000–2500 nm) is essential for advanced photonic technologies, as this region offers dramatically reduced photon scattering in complex media and intrinsic compatibility with optical communication bands. Here, we report a new class of NIR-II nanoprobes based on transition-metal Ni2+-doped fluoride nanocrystals, in which Ni2+ ions serve simultaneously as both sensitizer and activator. Theoretical analysis and experimental validation reveal that varying the matrix from NaMgF3 to MgF2, KMgF3, and NaMnF3 systematically modulates the local Ni–F bond length and the coordination environment of Ni2+. This bond-length engineering enables broadband and finely tunable NIR-II absorption (1318–1414 nm) and emission (1620–1780 nm) from d–d electronic transitions, with the optimized NaMgF3:9.6%Ni@NaMgF3 nanocrystals achieving a quantum yield of 20.7% under 1320 nm excitation. Using these distinctive excitation–emission fingerprints, we demonstrate low-crosstalk in vivo multiplexed imaging with high signal-to-noise ratios. This work establishes transition-metal-doped nanocrystals as a broadly tunable platform and expands the scope of inorganic luminescent materials for next-generation photonic applications.

  • Top Cited Papers

    Label-free tissue NIR-II autofluorescence imaging for visualization of human liver malignancy

    by Haisheng He, Wenwei Zhu, Han Miao, Shangfeng Wang, Zunguo Du, Hongxin Zhang, Jiang Ming, Ben Shi, Hao Wang, Jianping Qi, et al.

    Successful surgical resection of solid tumours requires highly reliable real-time intraoperative tools to accurately delineate tumour boundaries, which remains challenging in routine clinical standards. Here, we identify endogenous substances with intense autofluorescence in the second near-infrared window (NIR-II, 1,000–1,700 nm) that are abundant in human liver tissues but negligible in cancerous tissues. Inspired by this discovery, we develop a label-free and wide-field imaging approach, named tissue autofluorescence NIR-II imaging (TANI) for visualizing human liver malignancies. TANI demonstrates exceptional contrast (7.69 ± 0.52), sensitivity (97.8%) and specificity (98.4%) in delineating various liver malignancies, including hepatocellular carcinoma, intrahepatic cholangiocarcinoma and liver metastasis from cirrhotic or non-cirrhotic livers, outperforming routine fluorescence-guided surgery and conventional autofluorescence imaging in the visible (400–650 nm) or first near-infrared (700–900 nm) window. The excellent performance of TANI remains unaffected by cancer grade/stage, benign lesions or blood/bile contamination. These findings represent a promising advance in intraoperative decision-making and suggest a strong correlation between near-infrared autofluorescence and diseases. We believe that clarifying the molecular insights underlying these autofluorescent substances may provide new diagnostic directions.


  • Interface Energy Tuning in Lanthanide Upconversion Nanoparticles through a Multilayer Growth Strategy

    by Jiang Ming, Xusheng Wang, Hongxin Zhang, Fan Zhang

    ConspectusLanthanide-doped upconversion nanoparticles (UCNPs) have emerged as a revolutionary class of optical probes, converting low-energy near-infrared (NIR) photons into higher-energy visible or NIR emissions. This unique anti-Stokes process offers substantial advantages for biomedical applications including minimal autofluorescence interference and deep tissue penetration. Despite these promising features, the bioapplication of UCNPs was restricted by a critical bottleneck: low luminescence efficiency driven by severe surface-related quenching effects, such as the vibration of hydrogen-oxygen bonds. The advent of core-shell architectures has largely addressed this efficiency issue by passivating surface defects and shielding the core from environmental quenching. Nevertheless, conventional shell-growth strategies often lack the requisite atomic-level precision to strictly confine the doped ions, limiting their ability to construct well-defined interfacial structures. To fully realize the potential of UCNPs in advanced scenarios, such as multiplexed imaging, neuromodulation, and deep tissue sensing, we must move beyond simple surface passivation to address a more profound challenge: the directional control of interface energy transfer in a single nanoparticle. This necessitates precise control over doping ion interactions to effectively modulate spectral crosstalk, cross-relaxation, and inner-filter effects. To meet these demands, our group developed a one pot successive layer-by-layer (SLBL) strategy that enables the fabrication of multilayer nanostructures with atomic-level precision. This method provides an unprecedented tool for spatially segregating different lanthanide dopants, thereby transforming each interface into a programmable energy landscape.In this Account, we summarize our contributions to the field of multilayer UCNPs, centered on the concept of "interface energy tuning". First, we introduce the principles and practical implementation of our versatile SLBL, leveraging precise reaction kinetics to manipulate the epitaxial growth of the shell layer. Next, we demonstrate how this approach enables the creation of a single nanoparticle capable of orthogonal trichromatic upconversion luminescence, facilitating groundbreaking applications in multiplexed optogenetic neuromodulation and NIR light vision to humans. We then shift our focus to the NIR window, especially the second near-infrared imaging window (NIR-II, 1000-2000 nm), detailing the unique design of novel Er3+-, Tm3+-, and Ho3+-sensitized UCNP systems endowed with NIR-II excitation, which is intrinsically unlocked by precise multilayer engineering. Finally, we highlight the in vivo applications of these advanced NIR-II probes, including real-time ratiometric biosensing, high-throughput multiplexed imaging, and dynamic visualization in animals. We believe that this Account will not only showcase the power of interface energy tuning but also provide a rational design framework for the next generation of programmable photonic nanodevices for cutting-edge biomedical research.


  • Near-infrared orthogonal excitation lanthanide theranostic nanoplatform for NIR-II-L imaging-guided photodynamic therapy via synergistical pyroptosis and apoptosis pathway

    by Jialing Zhou, Jiang Ming, Zhenfeng Yu, Zhihua Wang, Wenlin Li, Ahmed Mohamed El-Toni, Aliyah Almomen, Aibin Liang, Yong Fan, Fan Zhang


  • Open Access

    Water-insensitive down-shifting nanoparticles for sensitive biosensing

    by Jiang Ming, Sikun Hu, Fan Zhang

    Conventional optical probes suffer from signal degradation in aqueous media, hindering sensitive biodetection. To overcome this, newly developed water-insensitive down-shifting nanoparticles (WINPs) possess superior photophysical properties in the NIR-I window, including high quantum yield and negligible thermal effects, permitting stable, high-contrast signal generation under low excitation power. This advantage facilitated a low-power lateral flow assay capable of highly sensitive avian influenza virus (AIV) detection in the opaque biological matrices (such as avian swabs), mitigating interference issues relying on visible-range signals.


  • Synthesis of transition metal-sensitized lanthanide near-infrared luminescent nanoparticles

    by Jiang Ming, Zheng Xie, Jiaxin Wu, Fan Zhang

    The versatility of lanthanide-doped near-infrared (NIR, 700–1,700 nm) luminescent nanoparticles makes them valuable tools in various scientific and technological fields, from bioimaging to information security. However, the luminescence intensity of typical lanthanide-doped nanoparticles is significantly influenced by the efficiency of the sensitizer. The introduction of transition metal ions (such as Cr3+, Mn2+ and Ni2+) can greatly enrich the library of lanthanide NIR luminescence nanoparticles. We have reported a new crystalline nanoparticle, Na3CrF6, for high-brightness NIR emission from lanthanide activators (such as Er3+, Tm3+, Yb3+ or Nd3+). As an emerging luminescent material, a straightforward and scalable synthesis approach for these nanostructures holds promise for their broader application. Here we have refined and standardized the steps for transition metal-sensitized lanthanide luminescent nanoparticles, thereby establishing a library of advanced luminescent materials for researchers engaged in luminescent materials. The Protocol enables the precise preparation of chromium-, manganese- and nickel-trifluoroacetate, the synthesis of three types of transition metal-sensitized lanthanide nanoparticle and the fabrication of chromium-sensitized lanthanide homogeneous and heterogeneous nanostructure. Moreover, we provide verification protocols for each step’s output and guidelines for adjusting synthesis conditions. To aid in the reproducible synthesis of these nanoparticles, we also include a troubleshooting guide of the various stages. The estimated duration for synthesizing transition metal trifluoroacetate, transition metal-sensitized lanthanide nanoparticles and core–shell transition metal-sensitized lanthanide nanoparticles are ~70, 30 and 30 h, respectively. These procedures can be carried out by users with expertise in chemistry or materials science.