Hajime Yoshida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hajime Yoshida has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Kenta Arai
AIST, National Metrology Institute of Japan , Tsukuba, Japan, Central 3, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan
11 shared publicationsHitoshi Akimichi
8 shared publicationsMasahiro Hirata
7 shared publications- Tokihiko Kobata
National Institute of Advanced Industrial Science and Technology
5 shared publications - Kenta Arai
Division of Material and Manufacturing Science, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan
4 shared publications - Takeo Ebina
AIST Tohoku
3 shared publications
Latest Publications
- 1 December 2025
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 43 (6)
Precise evaluation of thermal transpiration effect for calibration of capacitance diaphragm gauge
The pressure ratio due to thermal transpiration was measured by using two high-accuracy capacitance diaphragm gauges (CDGs) with sapphire diaphragms using a method independent of the temperature dependence of the CDGs. Two-step compensation for the thermal transpiration effect was performed because two pipes connected in series with different inner diameters (4.4 and 10.16 mm) were used to link the CDG to the vacuum chamber. The measurements agreed with calculations by the Takaishi–Sensui equation [Trans. Farad. Soc. 59, 2503 (1963)] using the constants A*, B*, and C* proposed by Setina [Metrologia 36, 623–626 (1999)] within 0.22% in the range of 23–100 °C and from 1.4 to 15 Pa. It was also experimentally confirmed that this compensation method for thermal transpiration is suitable for routine calibration of CDGs.
- 1 December 2025
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 43 (6)
Precise evaluation of thermal transpiration effect for calibration of capacitance diaphragm gauge
The pressure ratio due to thermal transpiration was measured by using two high-accuracy capacitance diaphragm gauges (CDGs) with sapphire diaphragms using a method independent of the temperature dependence of the CDGs. Two-step compensation for the thermal transpiration effect was performed because two pipes connected in series with different inner diameters (4.4 and 10.16 mm) were used to link the CDG to the vacuum chamber. The measurements agreed with calculations by the Takaishi–Sensui equation [Trans. Farad. Soc. 59, 2503 (1963)] using the constants A*, B*, and C* proposed by Setina [Metrologia 36, 623–626 (1999)] within 0.22% in the range of 23–100 °C and from 1.4 to 15 Pa. It was also experimentally confirmed that this compensation method for thermal transpiration is suitable for routine calibration of CDGs.
- 16 June 2025
- Published by Elsevier in Measurement
- Vol. 256
Comparison of water vapor transmission rates using different measurement methods
- 16 June 2025
- Published by Elsevier in Measurement
- Vol. 256
Comparison of water vapor transmission rates using different measurement methods
- 12 June 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (4)
Upgrading of the modified Knudsen equation and its verification for calculating the gas flow rate through cylindrical tubes
The modified Knudsen equation was developed to calculate the gas flow rate through a cylindrical tube with arbitrary length-to-diameter ratio in any flow regime including molecular flow, viscous laminar flow, turbulent flow, critical flow, subcritical flow, and their intermediates in our laboratory. Here, it is upgraded for better agreement with literature data, and the upgraded version is compared with 83 literature sources including 31 gas flow equations to verify its reliability. For Kn > 10−5, the modified Knudsen equation mostly agrees with the literature data to within 20%, except for orifice flows with pd/pu ≈ 1.
- 12 June 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (4)
Upgrading of the modified Knudsen equation and its verification for calculating the gas flow rate through cylindrical tubes
The modified Knudsen equation was developed to calculate the gas flow rate through a cylindrical tube with arbitrary length-to-diameter ratio in any flow regime including molecular flow, viscous laminar flow, turbulent flow, critical flow, subcritical flow, and their intermediates in our laboratory. Here, it is upgraded for better agreement with literature data, and the upgraded version is compared with 83 literature sources including 31 gas flow equations to verify its reliability. For Kn > 10−5, the modified Knudsen equation mostly agrees with the literature data to within 20%, except for orifice flows with pd/pu ≈ 1.
- Open Access
- 10 August 2022
- Published by Surface Science Society Japan in Vacuum and Surface Science
- Vol. 65 (8) , 367-371
Amendment to JIS Z 8126-1 Vacuum Technology –Vocabulary– Part 1 : General Terms
JIS Z 8126-1 Vacuum technology –Vocabulary– Part 1 : General terms, which corresponds to ISO 3529-1 Vacuum technology –Vocabulary– Part 1 : General terms, was amended for the first time in 22 years in 2021 to harmonize with the amendment of ISO 3529-1 in 2019. The committee for the amendment of JIS Z 8126-1, which was mainly composed of members of joint committee for standardization of JVSS and JVIA, worked to prepare the amended draft. Several important amended points such as the definition of “standard reference condition”, “low pressure”, “high pressure” and so on are introduced.
- 10 August 2022
- Published by Surface Science Society Japan in Vacuum and Surface Science
- Vol. 65 (8) , 367-371
Open AccessAmendment to JIS Z 8126-1 Vacuum Technology –Vocabulary– Part 1 : General Terms
JIS Z 8126-1 Vacuum technology –Vocabulary– Part 1 : General terms, which corresponds to ISO 3529-1 Vacuum technology –Vocabulary– Part 1 : General terms, was amended for the first time in 22 years in 2021 to harmonize with the amendment of ISO 3529-1 in 2019. The committee for the amendment of JIS Z 8126-1, which was mainly composed of members of joint committee for standardization of JVSS and JVIA, worked to prepare the amended draft. Several important amended points such as the definition of “standard reference condition”, “low pressure”, “high pressure” and so on are introduced.
- Open Access
- 3 June 2021
- Published by Wiley in Packaging Technology and Science
- Vol. 34 (9) , 557-566
Comparison of measured leak rates and calculation values for sealing packages
- 3 June 2021
- Published by Wiley in Packaging Technology and Science
- Vol. 34 (9) , 557-566
Open AccessComparison of measured leak rates and calculation values for sealing packages
- 28 March 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 36 (3)
Quantitative measurements of various gases in high and ultrahigh vacuum
Two calibration methods for ionization gauges, a measurement method for the effective pumping speed of turbomolecular pumps, and a method for introducing low gas flow rates into vacuum chambers were examined. Twenty-four gases were used, including inert gases, hydrocarbons, oxygen, carbon oxide, chlorofluorocarbons, and liquid vapors. Direct comparison with a reference spinning rotor gauge and incorporation of the standard conductance element into the conductance modulation methods were tested as calibration methods in the range from 10−6 to 10−3 Pa. The effective pumping speed of a turbomolecular pump with a nominal pumping speed of 0.37 m3/s for N2 was measured using the modified conductance modulation method. A standard conductance element, which is a porous plug fabricated from sintered stainless steel, was tested in the range of 10−8 to 10−4 Pa m3/s to quantitatively introduce gas into a vacuum chamber. The obtained results were compared with previously reported values.
- 28 March 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 36 (3)
Quantitative measurements of various gases in high and ultrahigh vacuum
Two calibration methods for ionization gauges, a measurement method for the effective pumping speed of turbomolecular pumps, and a method for introducing low gas flow rates into vacuum chambers were examined. Twenty-four gases were used, including inert gases, hydrocarbons, oxygen, carbon oxide, chlorofluorocarbons, and liquid vapors. Direct comparison with a reference spinning rotor gauge and incorporation of the standard conductance element into the conductance modulation methods were tested as calibration methods in the range from 10−6 to 10−3 Pa. The effective pumping speed of a turbomolecular pump with a nominal pumping speed of 0.37 m3/s for N2 was measured using the modified conductance modulation method. A standard conductance element, which is a porous plug fabricated from sintered stainless steel, was tested in the range of 10−8 to 10−4 Pa m3/s to quantitatively introduce gas into a vacuum chamber. The obtained results were compared with previously reported values.
- Open Access
- 1 May 2017
- Published by Japan Petroleum Institute in Journal of the Japan Petroleum Institute
- Vol. 60 (3) , 121-126
Development of Clay-based Film and Its Application to Gas Barrier Layers of Composite Tanks
- 1 May 2017
- Published by Japan Petroleum Institute in Journal of the Japan Petroleum Institute
- Vol. 60 (3) , 121-126
Open AccessDevelopment of Clay-based Film and Its Application to Gas Barrier Layers of Composite Tanks
- 1 April 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (4) , 043301
Development of water vapor transmission rate measuring device using a quadrupole mass spectrometer and standard gas barrier films down to the 10−6 g m−2 day−1 level
Water vapor transmission rate (WVTR) measuring devices with a quadrupole mass spectrometer (QMS) have an advantage in measuring low WVTRs because measurements are taken under an extremely low background of water vapor by realizing ultrahigh vacuum conditions. Here, the reliability of the QMS measurements was improved by including a porous plug with known molecular conductance in the device to generate a reference molar flux for in situ QMS calibration. Then, standard gas barrier (SGB) films made from a clay-polyimide nanocomposite film were also developed and used to validate the measurement. The measurement results for the SGB films were on the extrapolated calibration curve obtained with the porous plug down to WVTR at the 10−6 g m−2 day−1 level within the estimated measurement uncertainty.
- 1 April 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (4) , 043301
Development of water vapor transmission rate measuring device using a quadrupole mass spectrometer and standard gas barrier films down to the 10−6 g m−2 day−1 level
Water vapor transmission rate (WVTR) measuring devices with a quadrupole mass spectrometer (QMS) have an advantage in measuring low WVTRs because measurements are taken under an extremely low background of water vapor by realizing ultrahigh vacuum conditions. Here, the reliability of the QMS measurements was improved by including a porous plug with known molecular conductance in the device to generate a reference molar flux for in situ QMS calibration. Then, standard gas barrier (SGB) films made from a clay-polyimide nanocomposite film were also developed and used to validate the measurement. The measurement results for the SGB films were on the extrapolated calibration curve obtained with the porous plug down to WVTR at the 10−6 g m−2 day−1 level within the estimated measurement uncertainty.
- Open Access
- 17 October 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 35408
Accurate and stable equal-pressure measurements of water vapor transmission rate reaching the 10−6 g m−2 day−1 range
The water vapor transmission rate (WVTR) of a gas barrier coating is a critically important parameter for flexible organic device packaging, but its accurate measurement without mechanical stress to ultrathin films has been a significant challenge in instrumental analysis. At the current stage, no reliable results have been reported in the range of 10−6 g m−2 day−1 that is required for organic light emitting diodes (OLEDs). In this article, we describe a solution for this difficult, but important measurement, involving enhanced sensitivity by a cold trap, stabilized temperature system, pumped sealing and calibration by a standard conductance element.
- 17 October 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 35408
Open AccessAccurate and stable equal-pressure measurements of water vapor transmission rate reaching the 10−6 g m−2 day−1 range
The water vapor transmission rate (WVTR) of a gas barrier coating is a critically important parameter for flexible organic device packaging, but its accurate measurement without mechanical stress to ultrathin films has been a significant challenge in instrumental analysis. At the current stage, no reliable results have been reported in the range of 10−6 g m−2 day−1 that is required for organic light emitting diodes (OLEDs). In this article, we describe a solution for this difficult, but important measurement, involving enhanced sensitivity by a cold trap, stabilized temperature system, pumped sealing and calibration by a standard conductance element.