Michael S. Shuler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael S. Shuler has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Thomas E Whitesides
2 shared publicationsThomas J. Moore
2 shared publicationsWilliam M. Reisman
2 shared publications- Ashley Cole
GlaxoSmithKline USA Collegeville
1 shared publication Ashley L. Cole
1 shared publication- Dhairya Shukla
St. Luke’s University Health Network
1 shared publication
Latest Publications
- Open Access
- 1 March 2021
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 63, 102176
Retrospective analysis of trends in surgery volumes between 2016 and 2019 and impact of the insurance deductible: Cross-sectional study
Understanding trends in surgical volumes can help Ambulatory Surgery Centers (ASCs) prevent clinician burnout and provide adequate staffing while maintaining the quality of patient care throughout the year. Health insurance deductibles reset in January each year and may contribute to an annual rhythm where the levee of year-end deductibles is breached in the last few months of every year, resulting in a flood of cases and several accompanying challenges. This study aims to identify and analyze monthly and yearly surgical volume patterns in ASCs and explore a relationship with the deductible reset. De-identified, aggregate visit data for 2016–2019 were obtained retrospectively from 14 ambulatory surgery centers within the same benchmarking consortium in the Southeast. The ASCs subspecialty types consisted of orthopedics, urology, otolaryngology, and multispecialty. Kaiser Family Foundation survey data from 2016 to 2019 was used to inform deductible trends. Augmented Dickey-Fuller tests, linear regressions, and two-sample T-tests were conducted to explore and establish patterns in surgical volume between 2016 and 2019. Overall, average orthopedic surgical volume increased 38.04% from January to December in 2016–2019 with an average difference of 64 cases (95% CI: 47–80), while that of all ASCs combined increased 19.24% within the same timeframe with an average difference of 37 cases (95% CI: 21–52). Average health insurance deductibles rose 12% from $1476 to $1655 within the same timeframe. Regression analysis showed a stronger association between year and volume for orthopedic ASCs (R (Claxton et al., 2019) [2] = 0.796) than for all ASCs combined (R (Claxton et al., 2019) [2] = 0.645). Regression analysis also showed a stronger association between month and volume for orthopedic ASCs (R (Claxton et al., 2019) [2] = 0.488–0.805) than for all ASCs combined (R (Claxton et al., 2019) [2] = 0.115–0.493). This study is first to identify regular and predictable yearly and monthly increases in orthopedic ASCs surgical volume. The study also identifies yearly increases in surgical volume for all ASCs. The combination of increasing yearly demand for orthopedic surgery and growing association between month and volume leads to an unnecessary year-end rush. The study aims to inform future policy decisions as well as help ASCs better manage resources throughout the year.
- 1 March 2021
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 63, 102176
Open AccessRetrospective analysis of trends in surgery volumes between 2016 and 2019 and impact of the insurance deductible: Cross-sectional study
Understanding trends in surgical volumes can help Ambulatory Surgery Centers (ASCs) prevent clinician burnout and provide adequate staffing while maintaining the quality of patient care throughout the year. Health insurance deductibles reset in January each year and may contribute to an annual rhythm where the levee of year-end deductibles is breached in the last few months of every year, resulting in a flood of cases and several accompanying challenges. This study aims to identify and analyze monthly and yearly surgical volume patterns in ASCs and explore a relationship with the deductible reset. De-identified, aggregate visit data for 2016–2019 were obtained retrospectively from 14 ambulatory surgery centers within the same benchmarking consortium in the Southeast. The ASCs subspecialty types consisted of orthopedics, urology, otolaryngology, and multispecialty. Kaiser Family Foundation survey data from 2016 to 2019 was used to inform deductible trends. Augmented Dickey-Fuller tests, linear regressions, and two-sample T-tests were conducted to explore and establish patterns in surgical volume between 2016 and 2019. Overall, average orthopedic surgical volume increased 38.04% from January to December in 2016–2019 with an average difference of 64 cases (95% CI: 47–80), while that of all ASCs combined increased 19.24% within the same timeframe with an average difference of 37 cases (95% CI: 21–52). Average health insurance deductibles rose 12% from $1476 to $1655 within the same timeframe. Regression analysis showed a stronger association between year and volume for orthopedic ASCs (R (Claxton et al., 2019) [2] = 0.796) than for all ASCs combined (R (Claxton et al., 2019) [2] = 0.645). Regression analysis also showed a stronger association between month and volume for orthopedic ASCs (R (Claxton et al., 2019) [2] = 0.488–0.805) than for all ASCs combined (R (Claxton et al., 2019) [2] = 0.115–0.493). This study is first to identify regular and predictable yearly and monthly increases in orthopedic ASCs surgical volume. The study also identifies yearly increases in surgical volume for all ASCs. The combination of increasing yearly demand for orthopedic surgery and growing association between month and volume leads to an unnecessary year-end rush. The study aims to inform future policy decisions as well as help ASCs better manage resources throughout the year.
- Open Access
- 7 August 2020
- Published by Elsevier in Journal of Hand Surgery Global Online
- Vol. 2 (5) , 301-305
Effectiveness of Amniotic Fluid Injection in the Treatment of Trigger Finger: A Pilot Study
- 7 August 2020
- Published by Elsevier in Journal of Hand Surgery Global Online
- Vol. 2 (5) , 301-305
Open AccessEffectiveness of Amniotic Fluid Injection in the Treatment of Trigger Finger: A Pilot Study
- Open Access
- 8 January 2020
- Published by Elsevier in Journal of Hand Surgery Global Online
- Vol. 2 (1) , 25-30
Suture Button Suspensionplasty in the Treatment of Carpometacarpal Arthritis: A Retrospective Analysis of One Surgeon’s Experience Over 9 Years
- 8 January 2020
- Published by Elsevier in Journal of Hand Surgery Global Online
- Vol. 2 (1) , 25-30
Open AccessSuture Button Suspensionplasty in the Treatment of Carpometacarpal Arthritis: A Retrospective Analysis of One Surgeon’s Experience Over 9 Years
- 1 October 2011
- Published by Elsevier in Journal of Hand Therapy
- Vol. 24 (4) , 383-384
Compression Glove May Reduce Complications Secondary to Distal Radius Fracture
- 1 October 2011
- Published by Elsevier in Journal of Hand Therapy
- Vol. 24 (4) , 383-384
Compression Glove May Reduce Complications Secondary to Distal Radius Fracture
- 1 April 2010
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 92 (4) , 863-870
Correlation Between Muscle Oxygenation and Compartment Pressures in Acute Compartment Syndrome of the Leg
Ble of detecting perfusion deficits. Methods: Fourteen patients with unilateral lower extremity trauma were enrolled after the diagnosis of an acute compartment syndrome was made clinically and confirmed with intracompartmental pressure measurements. Lower extremity muscle compartments were evaluated with near-infrared spectroscopy, and near-infrared spectroscopy values of the uninjured, contralateral leg of each patient were used as internal reference values. The compartment perfusion gradient was calculated as the diastolic blood pressure minus the intracompartmental pressure. Results: Intracompartmental pressures ranged from 21 to 176 mm Hg (mean, 79 mm Hg) and exceeded 30 mm Hg in all compartments but two (both in the same patient). Thirty-eight compartments had a perfusion gradient of ≤10 mm Hg (indicating ischemia). Among ischemic compartments, near-infrared spectroscopy values in the anterior, lateral, deep posterior, and superficial posterior compartments of the injured limbs were decreased by an average 10.1%, 10.1%, 9.4%, and 16.3% in comparison with the corresponding compartments of the uninjured leg. Differences in near-infrared spectroscopy values (the near-infrared spectroscopy value for the injured leg minus the near-infrared spectroscopy value for the uninjured leg) were positively correlated with compartment perfusion gradient within each compartment (r = 0.82, 0.65, 0.67, and 0.62, for the anterior, lateral, deep posterior, and superficial posterior compartments, respectively; p < 0.05 for all). Conclusions: Normalized near-infrared spectroscopy values decrease significantly with decreasing lower limb perfusion pressures. Near-infrared spectroscopy may be capable of differentiating between injured patients with and without an acute compartment syndrome. Level of Evidence: Diagnostic Level IV. See Instructions to Authors for a complete description of levels of evidence....
- 1 April 2010
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 92 (4) , 863-870
Correlation Between Muscle Oxygenation and Compartment Pressures in Acute Compartment Syndrome of the Leg
Ble of detecting perfusion deficits. Methods: Fourteen patients with unilateral lower extremity trauma were enrolled after the diagnosis of an acute compartment syndrome was made clinically and confirmed with intracompartmental pressure measurements. Lower extremity muscle compartments were evaluated with near-infrared spectroscopy, and near-infrared spectroscopy values of the uninjured, contralateral leg of each patient were used as internal reference values. The compartment perfusion gradient was calculated as the diastolic blood pressure minus the intracompartmental pressure. Results: Intracompartmental pressures ranged from 21 to 176 mm Hg (mean, 79 mm Hg) and exceeded 30 mm Hg in all compartments but two (both in the same patient). Thirty-eight compartments had a perfusion gradient of ≤10 mm Hg (indicating ischemia). Among ischemic compartments, near-infrared spectroscopy values in the anterior, lateral, deep posterior, and superficial posterior compartments of the injured limbs were decreased by an average 10.1%, 10.1%, 9.4%, and 16.3% in comparison with the corresponding compartments of the uninjured leg. Differences in near-infrared spectroscopy values (the near-infrared spectroscopy value for the injured leg minus the near-infrared spectroscopy value for the uninjured leg) were positively correlated with compartment perfusion gradient within each compartment (r = 0.82, 0.65, 0.67, and 0.62, for the anterior, lateral, deep posterior, and superficial posterior compartments, respectively; p < 0.05 for all). Conclusions: Normalized near-infrared spectroscopy values decrease significantly with decreasing lower limb perfusion pressures. Near-infrared spectroscopy may be capable of differentiating between injured patients with and without an acute compartment syndrome. Level of Evidence: Diagnostic Level IV. See Instructions to Authors for a complete description of levels of evidence....
- 1 June 2009
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 91 (6) , 1360-1368
Near-Infrared Spectroscopy in Lower Extremity Trauma
Background: Near-infrared spectroscopy measures the percentage of hemoglobin oxygen saturation in the microcirculation of tissue up to 3 cm below the skin. The purpose of this study was to describe the measurable response of normal tissue oxygenation in the leg after acute trauma with use of this technique. Methods: Twenty-six patients with acute unilateral tibial fractures and twenty-five uninjured volunteer control subjects were enrolled. Near-infrared spectroscopy measurements were obtained for both legs in all four compartments: anterior, lateral, deep posterior, and superficial posterior. The twenty-six injured legs were compared with twenty-five uninjured legs (randomly selected) of the volunteer control group, with the contralateral limb in each patient serving as an internal control. Results: The mean tissue oxygenation for each compartment in the injured legs was 69% (anterior), 70% (lateral), 74% (deep posterior), and 70% (superficial posterior). In the control (uninjured) legs, the average tissue oxygenation percentage in each compartment was 54%, 55%, 60%, and 57%, respectively. Repeated-measures analysis revealed that near-infrared spectroscopy values averaged 15.4 percentage points (95% confidence interval, 12.2 to 18.6 percentage points) higher for injured legs than for uninjured legs, controlling for the value of the contralateral limb (p < 0.0001). Conclusions: Tibial fracture produces a predictable increase in tissue oxygenation as measured by near-infrared spectroscopy. The corresponding compartment of the contralateral leg can provide strong utility as an internal control value when evaluating the hyperemic response to injury. Level of Evidence: Prognostic Level I. See Instructions to Authors for a complete description of levels of evidence.
- 1 June 2009
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 91 (6) , 1360-1368
Near-Infrared Spectroscopy in Lower Extremity Trauma
Background: Near-infrared spectroscopy measures the percentage of hemoglobin oxygen saturation in the microcirculation of tissue up to 3 cm below the skin. The purpose of this study was to describe the measurable response of normal tissue oxygenation in the leg after acute trauma with use of this technique. Methods: Twenty-six patients with acute unilateral tibial fractures and twenty-five uninjured volunteer control subjects were enrolled. Near-infrared spectroscopy measurements were obtained for both legs in all four compartments: anterior, lateral, deep posterior, and superficial posterior. The twenty-six injured legs were compared with twenty-five uninjured legs (randomly selected) of the volunteer control group, with the contralateral limb in each patient serving as an internal control. Results: The mean tissue oxygenation for each compartment in the injured legs was 69% (anterior), 70% (lateral), 74% (deep posterior), and 70% (superficial posterior). In the control (uninjured) legs, the average tissue oxygenation percentage in each compartment was 54%, 55%, 60%, and 57%, respectively. Repeated-measures analysis revealed that near-infrared spectroscopy values averaged 15.4 percentage points (95% confidence interval, 12.2 to 18.6 percentage points) higher for injured legs than for uninjured legs, controlling for the value of the contralateral limb (p < 0.0001). Conclusions: Tibial fracture produces a predictable increase in tissue oxygenation as measured by near-infrared spectroscopy. The corresponding compartment of the contralateral leg can provide strong utility as an internal control value when evaluating the hyperemic response to injury. Level of Evidence: Prognostic Level I. See Instructions to Authors for a complete description of levels of evidence.